The EZC Classic Adjust Door Frame is a versatile door frame system designed for easy installation. It is suitable for use with Herline/Liftoff Hinges and RY60 Concealed Hinges. The frame is made of high-quality materials and is adjustable to accommodate various door sizes. The frame is compatible with both timber and steel studs.

Product Usage Instructions

  1. Step 1: Ensure that the stud opening is square and level.
  2. Step 2: Fasten the hinge side of the frame first, making sure the jamb is level and tight against the stud opening. Screw at 200mm centers up the stile, screwing back through the plasterboard into the stud work. Double-screw all ends as per Detail D and beside the hinge position, both above and below the hinge as per Detail E.
  3. Step 2A: Install the head section by inserting it into the jamb. Make sure the head joiner is flush with the jamb so that it is not visible. Remove the remaining head joiner out of the strike jamb into the end of the head to receive the strike jamb.
  4. Step 3: Fit the final vertical section (strike jamb) into the head section joining clip. Ensure that the spacing between the two vertical sections is evenly spaced at the required distance.
  5. Step 4: Ensure that the perforated side strips sit flat against the plasterboard. Tape and plaster/joint all corners as Detail F. Finish the jamb with approved plaster/jointing compound. Hang the door in position, leaving about 3mm clearance from the top and the hinged side using the EzyJamb Standard or concealed Hinges. Surface mount the striker plate into position to align with the latch plate punching.
  6. Completed Installation: The jamb should be flush finished and can be painted along with the whole wall area to fully conceal any fixing, achieving simple clean lines around the door face.

For further information or assistance in the installation of EzyJamb products, please visit www.ezconcept.com.au/installation.

Installation Instructions

Step 1

Ensure that the stud opening is square and level and measures: Stud opening sizes for Herline /Liftoff Hinges

  • Width Single Door Door Width +15mm Clearance
  • Width Double Door Door Width +18mm Clearance
  • Height Door Height +33mm (+8mm at header, +25mm at floor level)*

Stud opening sizes for RY60 Concealed Hinges

  • Width Single Door Door Width +40mm Clearance
  • Width Double Door Door Width +63mm Clearance
  • Height Door Height +33mm (+8mm at header, +25mm at floor level)*
  • depending on floor clearance. Check with the Project Manager on site to confirm floor coverings.
  • It is strongly recommended that a timber stud or a 0.75 BMT metal stud is used on both sides of the opening.

Demission

Step 2

  • Fasten the hinge side first, making sure the jamb is level and as tight against the stud opening as possible.
  • Then screw at 200mm centers up stile, screwing back through plasterboard into stud work See Detail ‘B’ and ‘C’.
  • Double screw all ends as per Detail D. and beside the hinge position both above and below the hinge as per Detail E.

Step 2A Head Installation

  • Head joiners as inserted in the jamb.
  • Locate the head into the joiner and flush with the jamb so the head joiner is not seen.
  • Remove the remaining head joiner out of the strike jamb into the end of the head (as shown) to receive the strike jamb.

Step 3

  • Fit the final vertical section (strike jamb) into the head section joining clip. Ensure that the spacing between the two vertical sections are spaced evenly at the required distance.
  • ie: 820mm door, opening is 825mm
  • 720mm door, opening is 725mm

Step 4

  • Ensure the perforated side strips sit flat against the plasterboard to enable the jamb sections to be easily set into the wall surface. All the corners must be taped and plastered/jointed in as Detail F. Finish the jamb with approved plaster/jointing compound.
  • Hang the door in position leaving about 3mm clearance from the top and the hinged side using the EzyJamb Standard or concealed Hinges. Surface mount the striker plate into position to align with the latch plate punching.

Completed Installation

  • The completed jamb is flush finished and can be painted in with the whole wall area to fully conceal any fixing, achieving simple clean lines around the door face.
  • For further information or assistance in installation of EzyJamb products, please visit: www.ezconcept.com.au/installation .
  • Information contained within this document supersedes all previous versions and is subject to change without notice.
  • www.ezconcept.com.au
  • For Sales and Technical Enquiries, please visit EZ Concept Australia 1300 329 526  sales@ezconcept.com.au
  • Contact the team for pricing & samples
  • hello@mbsarchitectural.com.au
  • 03 9580 7800
  • Every material. One source.
  • Reach out to our team for support, samples and advice. 03 9580 7800
  • hello@mbsarchitectural.com.au
  • VIC 7 Haymer Court, Braeside 3195
  • QLD 13 Pease Court, Bethania 4205
  • @MBSarchitectural

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals