R B Elettronica 3.86.015 Voltage Stabilizer for Flaps Instruction Manual

June 13, 2024
R B Elettronica

VOLTAGE STABILIZER FOR FLAPS
ITEM CODE 3.86.015

3.86.015 Voltage Stabilizer for Flaps

R B Elettronica 3.86.015 Voltage Stabilizer for FlapsCH1 POSITIVE UNDER KEY ENGINE 1
CH2 POSITIVE UNDER KEY ENGINE 2
RIT AUTOMATIC FLAPS RETURN (ONLY FOR ELECTRONIC POWER UNIT)
+ POSITIVE INPUT 12/ 24V
GND NEGATIVE INPUT

DEVICE CONNECTION TO SENSORS THROUGH POWER SUPPLY

R B Elettronica 3.86.015 Voltage Stabilizer for Flaps -
parts CALIBRATION OPERATION
WARNING!
Don’’t perform any calibration before the connection of all available devices.

  1. Completely fall left flap’s blade and check that left bar led is turned off, if it needs, proceed to adjust, act on trimmer of “ minimum left flap”
  2. Completely raise left flap’s blade and check taht left bar is turned on, if it needs, proceed to adjust, act on trimmer of * maximum left flap”
  3. To calibrate right flap perform the same procedure of left one

R B Elettronica 3.86.015 Voltage Stabilizer for Flaps -
parts1 CALIBRATION SETTING
This operation must be arranged during the installation to set the system with value of zero and end of scale of sensors. follow the procedure:

  • Activate the flaps to have them all on the bottom side (both). Push for 5 seconds the key IS located on the back side of device ( this operation is confirmed when 2 led on the middle will turn on).
  • Activate the flaps to have them all on the upper side (both). Push for 5 seconds the key FS located on the back side of device ( this operation is confirmed when 2 led on the middle will turn on)

R B Elettronica 3.86.015 Voltage Stabilizer for Flaps -
parts2 CALIBRATION SETTING
This operation must be arranged during the installation to set the system with value of zero and end of scale of sensors. follow the procedure:

  • Activate the flaps to have them all on the bottom side (both). Push for 5 seconds the key IS located on the back side of device ( this operation is confirmed when 2 led on the middle will turn on).
  • Activate the flaps to have them all on the upper side (both). Push for 5 seconds the key FS located on the back side of device ( this operation is confirmed when 2 led on the middle will turn on)