ecler eGPA Series Multichannel Amplifiers User Manual

June 13, 2024
ecler

ecler-logo

ecler eGPA Series Multichannel Amplifiers

ecler-eGPA-Series-Multichannel-Amplifiers-PRODUCT

Product Information

The GPA Series is a range of low-impedance amplifiers manufactured by NEEC AUDIO BARCELONA, S.L. These amplifiers are designed to provide high-quality audio amplification for multichannel applications.

The GPA Series includes the following models:

  • eGPA2-150
  • eGPA2-300
  • eGPA4-150
  • eGPA4-300
  • eGPA8-150
  • eGPA8-300

These amplifiers are built with Class I construction and require a main socket outlet with a protective earthing connection. They are equipped with various safety features to protect against electric shock and fire hazards.
Please note that failure to comply with the warnings and instructions provided in this manual may result in damage to people, animals, or objects, for which NEEC AUDIO BARCELONA, S.L. accepts no liability.

Product Usage Instructions

Before connecting the eGPA amplifier, it is crucial to read and understand this user manual to ensure its proper usage and maximize performance.

Follow the instructions below for optimal operation:

  1. Ensure the amplifier is placed in a well-ventilated area and not exposed to water or moisture.
  2. Clean the amplifier only with a dry cloth.
  3. Do not block any ventilation openings and install the amplifier according to the manufacturer’s instructions.
  4. Avoid installing the amplifier near heat sources such as radiators, heat registers, stoves, or other heat-producing apparatus.
  5. Use the provided power cord and protect it from being walked on or pinched, especially at the plugs, convenience receptacles, and where it exits from the amplifier.
  6. Only use attachments or accessories specified by the manufacturer.
  7. Unplug the amplifier during lightning storms or when it will be unused for long periods of time.
  8. Refer all servicing to qualified personnel. Servicing is required when the amplifier has been damaged, liquid has been spilled on it, objects have fallen into it, it has been exposed to rain or moisture, it does not operate normally, or it has been dropped.
  • For maintenance and repairs, it is recommended to contact NEEC AUDIO BARCELONA, S.L.’s authorized Technical Services.

  • The amplifier is covered by warranty, and the details can be found on the warranty card included with the product or on the manufacturer’s website at www.ecler.com.

  • Remember to dispose of this product properly by taking it to the nearest electrical and electronic waste treatment center. Do not discard it as unsorted urban waste.

IMPORTANT REMARK

  • CAUTION RISK oF ELECTRIC SHOCK DO NOT OPEN
  • WARNING: SHOCK HAZARD – DO NOT OPEN
  • The lightning flash with the arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • WARNING (If applicable): The terminals marked with the symbol “ ” may be of sufficient magnitude to constitute a risk of electric shock.
  • The external wiring connected to the terminals requires installation by an instructed person or the use of ready-made leads or cords.
  • WARNING: To prevent fire or shock hazards, do not expose this equipment to rain or moisture.
  • WARNING: An apparatus with Class I construction shall be connected to a main socket outlet with a protective earthing connection.

IMPORTANT SAFETY INSTRUCTIONS

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with a dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.
  11. Only use attachments/accessories specified by the manufacturer.
  12. Unplug the apparatus during lightening sorts or when unused for long periods of time.
  13. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as a power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  14. Disconnecting from mains: Switching off the POWER switch all the functions and light indicators of the amplifier will be stopped, but fully disconnecting the device from mains is done by unplugging the power cord from the mains input socket. For this reason, it always shall remain readily operable.
  15. Equipment is connected to a socket outlet with an earthing connection by means of a power cord.
  16. The marking information is located at the bottom of the apparatus.
  17. The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING: This product must not be discarded, under any circumstance, as unsorted urban waste. Take to the nearest electrical and electronic waste treatment center.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be caused to people, animals, or objects due to failure to comply with the warnings above.

IMPORTANT NOTE

  • Thank you for choosing our Ecler eGPA multichannel amplifier!
  • It is VERY IMPORTANT to carefully read this manual and to fully understand its contents before any connection in order to maximize your use and get the best performance from this equipment.
  • To ensure optimal operation of this device, we strongly recommend that its maintenance be carried out by our authorized Technical Services.
  • All ECLER products are covered by warranty, please refer to www.ecler.com or the warranty card included with this product for the period of validity and conditions.

INTRODUCTION

  • The eGPA amplifier series offers the renowned professional reliability of Ecler amplifiers at an affordable price. It consists of 4 models: with a power of 2 x 150W RMS @ 4 (eGPA2-150), 4 x 150W RMS @ 4 (eGPA4-150), 8 x 150W RMS @ 4 (eGPA8-150) and a last one with a power of 2 x 310W RMS @ 4 (eGPA2-300). All models use very high-performance technology, auto standby, and convection cooling, with a height of 1 rack unit.
  • Equipped with balanced inputs on Euroblock connectors. Outputs also feature Euroblock connectors. It has an electronic limitation system to avoid signal saturation and thermal protection, as well as a protection system against overload.

MAIN FEATURES

  • Easily accessible input attenuation controls on the front panel.
  • Switchable auto standby circuit (energy saving mode when there is no input signal)
  • Signal presence (SP), clipping (CLIP), protection against overload (PROT), and thermal protection (TH) indicators.
  • Built-in, always active antislip circuit
  • Operating mode selector: STEREO, MONO – BRIDGE
  • Balanced inputs on Euroblock connectors
  • Outputs on Euroblock connectors
  • Accepts 8 or 4Ω loads (1 or 2 speakers (8Ω) in parallel)

INSTALLATION

  • Non-compliance with the instructions may cause malfunction and may even damage the unit:
  1. Avoid turning on the device without speakers connected to its outputs and without having previously adjusted the volume/gain controls at a minimum level.
  2. Always use shielded cables to make connections between devices.
  3. In an amplifier, avoid placing the speaker output cables close to other signal cables (micro, line…). This may cause the system to oscillate, damaging the amplifier and speakers.

Placement, mounting, cooling

  • All eGPA amplifier models are presented in standard 19” rack format and are 1 unit high.
  • It is important that the amplifier, as a heat source, is not placed next to other equipment nor exposed to high temperatures.
  • CAUTION: The built-in convection cooling requires at least one free rack unit (empty space) both above and below each amplifier to ensure a correct airflow.
  • It is also advisable not to rack the power amplifiers under other devices, but on top of these, that is to say as high as possible toward the top of the rack cabinet.

Mains connection

  • The eGPA amplifiers are powered by 100 to 250VAC, 50/60Hz.
  • The main cables must not be near the shielded cables carrying the audio signal, as this could cause humming.
  • In order to protect the power amplifier from eventual power consumption overloads, it is protected by a set of fuses. Should a fuse blow, it must be replaced immediately by one with identical rating. Should it blow again please contact our Technical Service
  • Department. NEVER REPLACE THE FUSE WITH ANOTHER ONE WITH A HIGHER VALUE.
  • CAUTION: Fuse substitutions have to be performed by a qualified technician.

Input signal connections

  • The signal input connectors are of EUROBLOCK (12, 13) and are electronically balanced.

The pin assignment is as follows:

  • Hot or direct signal > +
  • Cold or phase inverted signal > –
  • Ground > Ground
  • For unbalanced connections, ground the negative terminal on the Euroblock.
  • In balanced mode, the input impedance is greater than 20k (10k unbalanced), allowing you to connect a large number of stages in parallel without compromising the sound quality.

Power saving mode

  • The AUTO STBY (10) switch allows to activate of the automatic switching circuit calling the power saving mode (low power consumption) when it detects no audio signal from the unit’s inputs for more than 90 seconds and automatically recovers normal operation when that signal reappears

Limiter circuit

  • This is an extra protection always enabled in the eGPA series amplifiers. This circuit dynamically limits the input signal to avoid clipping loud signals at the amplifier output; it automatically reduces the input level not to exceed approximately 5% distortion.
  • The great utility of this circuit in any type of installation should be noted; the advantage of this system over traditional compressors is that dynamics are practically not altered, due to its time constant.

Output connections

  • The output section on the rear panel features Euroblock connectors.
  • In STEREO mode, each channel takes the signal from its corresponding input (OUTPUT CH1 from INPUT CH1, OUTPUT CH2 from INPUT CH2, etc.). In MONO/BRIDGE mode, the signal is taken from the odd input only.
  • To operate the amplifier in bridged mode, the “ST/MONO” (14) switch shall be on MONO/BRIDGE.
  • The input signal connection is performed using the odd channel connector and the speaker signal comes out of the BRIDGE labeled terminals on the Euroblock output connector.
  • Optionally you can connect the other two output terminals to each other, in order to improve the distortion value. They have to be connected with a short cable.
  • The connection cable that joins the amplifier outputs and the loudspeakers must be of good quality, sufficient section, and as short as possible. This is most important when the distances to cover are long.

OPERATION AND USAGE

Startup

  • The red “PROT” LEDs (7) light up when you turn on the power switch (11). A second after all voltages have been stabilized and the amplifier is operating, “PROT” indicators turn off.
  • In a complete audio installation, it is important to power the equipment according to the following sequence: sound sources (microphones, music players, etc.), mixers, equalizers, active filters, and power amplifiers. To power off, follow the reverse sequence.

Input attenuators

  • This consists of rotary potentiometers, situated on the front panel (5, 6).
  • These attenuators allow connecting the amplifier to different types of mixers and processors, independent level control, and connection of speakers that can’t handle the wattage supplied by the output stage at full power, without risking damage if the volume of the preamplifier-mixer is set to high.

Indicators

  • eGPA amplifiers include a simple yet effective indication system.
  • PROT/STBY indicators (7) show the absence of a loudspeaker output signal. These indicators may light up for the following reasons:
  • During start-up, until the STANDBY time has passed. This time period is needed for the internal operating voltages to settle.
  • A short circuit is detected at the loudspeaker terminals (PROTECT function).
  • When the module enters AUTO-STANDBY mode. In this case, the indicator will illuminate in orange instead of red.
  • If these indicators remain lit in red, there’s a malfunction that should be investigated to find the cause of this lighting.
  • CLIP (2, 4) indicators light up when the signal level feeding the loudspeakers is just below the actual clipping. This CLIP system takes into account possible variations in the supply voltage, always giving a real indication.
  • CLIP indicators light up to the beat of low frequencies when working at high power levels; it’s normal as low frequencies are those with higher energy content. You must take care that these indicators do not remain continuously lit.
  • SP Signal Presence indicators (1, 3) indicate the presence of a valid signal at the amplifier inputs.
  • The TH (THERMAL) (8) indicator lights when the unit has entered the protection mode due to excessive temperature; normal operation is recovered when the amplifier’s internal temperature comes back down to regular operating levels.

CLEANING

  • The front panel should not be cleaned with dissolvent or abrasive substances because silk printing could be damaged.
  • To clean it, use a soft cloth slightly wet with water and neutral liquid soap; dry it with a clean cloth.
  • Be careful that water never gets into the amplifier through the holes of the front panel.

FUNCTION DIAGRAM

ecler-eGPA-Series-Multichannel-Amplifiers-FIG-2

FUNCTION LIST

  1. SP, signal presence indicator at the CH 1 input
  2. CLIP, clipping indicator for CH 1
  3. SP, signal presence indicator at the CH 2 input
  4. CLIP, clipping indicator for CH 2
  5. CH 1 input attenuator
  6. CH 2 input attenuator
  7. PROT/STBY, overload protection, and Standby status indicator
  8. TH, thermal protection indicator
  9. ON power indicator
  10. AUTO STANDBY switch
  11. Power switch
  12. CH 1, input 1 Euroblock connector
  13. CH 2, input 2 Euroblock connector
  14. STEREO, MONO/BRIDGE selector
  15. CH 1, output 1 Euroblock connector
  16. CH 2, output 2 Euroblock connector
  17. AC socket connector

NOTE: Listed functions are for two-channel models; for models with more than two channels, the number of these functions matches the number of amplifier channels.

TECHNICAL CHARACTERISTICS

  eGPA2-150 eGPA2-300
POWER 20-20kHz 1% THD  
1 Channel @ 4 W 148 WRMS 310 WRMS
1 Channel @ 8 W 74 WRMS 165 WRMS
All Channels @ 4 W 145 WRMS 600 WRMS
2 Bridged channels @ 8 W 290 WRMS 310 WRMS

Frequency response (-1dB, –

3dB)

| 20Hz – 25kHz| 20Hz – 25kHz
Filter (High-Pass)  3rd  order

Butterworth

| 15Hz| 15Hz
THD+Noise @ 1kHz Full Pwr.| <0.05%| <0.05%
S+N/N 20Hz – 20kHz @ 1W/4 W| >85dB| >85dB
CMRR| >55dB| >55dB
Damping factor 1kHz @ 8 W| >150| >150
Channel crosstalk @ 1kHz| >55dB| >55dB
Input Sensitivity / Impedance| 0dBV/>20kW| 0dBV/>20kW
Anticlip @ 2dBV input| <1% THD| <1% THD
Mains Voltage| 100-240VAC|
Power consumption (pink noise,

1/8 power @ 4 W )

| 63W| 110W
Power consumption (pink noise,

1/3 power @ 4 W )

| 139W| 251W
Power consumption (Idle)| 19W| 26W
Power consumption (STBY)| 13W| 22W
Efficiency @ Pmax| 77%| 87%
Dimensions (WxHxD)

(Handle excluded)

| 440 x44 x 161mm

17.32 x 1.73 x 6.34 in.

| 440 x 44 x 221mm

17.32 x 1.73 x 8.70 in.

Weight| 2.65 kg / 5.84 lb| 3.4kg / 7.5 lb
Shipping Dimensions (WxHxD)| 320 x 70 x 590 mm

12.6 x 2.76 x 23.23 in.

| 380 x 70 x 590 mm

14.97 x 2.76 x 23.23 in.

Shipping Weight| 3.7 kg / 8.16 lb| 4.6 kg / 10.14 lb
 | eGPA4-150| eGPA8-150
---|---|---
POWER 20-20kHz 1% THD|  |
1 Channel @ 4 W| 148 WRMS| 148 WRMS
1 Channel @ 8 W| 74 WRMS| 74 WRMS
All Channels @ 4 W| 145 WRMS| 144 WRMS
2 Bridged channels @ 8 W| 290 WRMS| 290 WRMS
Frequency response (-1dB, –

3dB)

| 20Hz – 25kHz| 20Hz – 25kHz
Filter (High-Pass)  3rd  order

Butterworth

| 15Hz| 15Hz
THD+Noise @ 1kHz Full Pwr.| <0.05%| <0.05%
S+N/N 20Hz – 20kHz @ 1W/4 W| >85dB| >85dB
CMRR| >55dB| >55dB
Damping factor 1kHz @ 8 W| >150| >150
Channel crosstalk @ 1kHz| >55dB| >55dB
Input Sensitivity / Impedance| 0dBV/>20kW| 0dBV/>20kW
Anticlip @ 2dBV input| <1% THD| <1% THD
Mains Voltage| 100-240VAC|
Power consumption (pink noise,

1/8 power @ 4 W )

| 113W / 130VA| 226W / 260VA
Power consumption (pink noise,

1/3 power @ 4 W )

| 268W| 536W
Power consumption (Idle)| 29W| 58W
Power consumption (STBY)| 18W| 36W
Efficiency @ Pmax| 80%| 80%
Dimensions (WxHxD)

(Handle excluded)

| 440 x 44 x221 mm

17.32 x 1.73 x 8.70 in.

| 440 x 44 x 341mm

17.32 x 1.73 x 14.21 in.

Weight| 3.7kg / 8.16 lb| 6.5kg / 14.43 lb
Shipping Dimensions (WxHxD)| 320 x 70 x 590 mm

12.6 x 2.76 x 23.23 in

| 510 x 70 x 590 mm

20.1 x 2.76 x 23.23 in.

Shipping Weight| 4.9 kg / 10.8 lb| 7.9 kg / 17.42 lb

BLOCK DIAGRAM

ecler-eGPA-Series-Multichannel-Amplifiers-FIG-3 ecler-eGPA-Series-Multichannel-Amplifiers-FIG-4 ecler-eGPA-Series-Multichannel-Amplifiers-FIG-5 ecler-eGPA-Series-Multichannel-Amplifiers-FIG-6

  • All product characteristics are subject to variation due to production tolerances.
  • NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications.
  • For technical queries contact your supplier, or distributor or complete the contact form on our website, in Support / Technical requests.
  • Motors, 166‐168 08038 Barcelona ‐ Spain ‐ (+34) 932238403
  • information@ecler.com
  • www.ecler.com

Documents / Resources

| ecler eGPA Series Multichannel Amplifiers [pdf] User Manual
eGPA2-4-8-150, 2-300, eGPA Series, eGPA Series Multichannel Amplifiers, Multichannel Amplifiers, Amplifiers
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals