etherstack XBR5100 Fully Integrated P25 Base-Station User Manual
- June 13, 2024
- etherstack
Table of Contents
etherstack XBR5100 Fully Integrated P25 Base-Station
Copyright
Etherstack Pty Ltd
ARBN 156 640 532
64 Rose Street Chippendale NSW 2008 Australia
Ph: +61 (0)2 8399 7500
Fax: +61 (0)2 8399 7507
info-au@etherstack.com
www.etherstack.com
Etherstack reserves the right to alter, without notice and at any time, the equipment and specifications described in this document. All performance figures quoted are typical and are subject to normal manufacturing and service tolerances.
The purchaser is advised that some statements made in this document may be inaccurate due to typographical or other errors or subsequent modifications of the product. While every care has been taken in the creation of this document, no warranty of accuracy or reliability is given, in any advice or information contained in this document. Etherstack Pty Ltd or any director, officer, agent, or employee of Etherstack Pty Ltd cannot be held liable for any loss or damage whatsoever arising in any way or any representation, act, or omission whether express or implied (including responsibility to any person by reason of negligence).
Copyright © Etherstack Pty Ltd 2023
This work is copyrighted. Other than as permitted by Law, no part of it may be
reproduced, stored in a retrieval system, or transmitted in any form or by any
process without prior written permission.
FCC
FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Interference Warning
Note: This equipment generates, uses, and can radiate radio frequency
energy. If not installed and used in accordance with this instruction manual,
may cause harmful interference to radio communication. Harmful interference is
any emission, radiation, or induction that endangers the functioning of a
radio navigation service or of other safety services or seriously degrades,
obstructs, or repeatedly interrupts a radio communications service operating
in accordance with CFR Title 47 Part 15.
HUMAN EXPOSURE TO RADIOFREQUENCY RADIATION (FCC)
USA Customers – Warning to comply with the maximum permissible exposure (MPE)
limits referenced in 47 CFR 1.1310, the following minimum safe operating
distances must be observed:
MODEL | FREQ. RANGE OPERATION | SAFE OPERATING DISTANCES |
---|---|---|
XBR5100T5V | 769-775 MHz |
851-869 MHz
| 2.6 m*
Date| Version| Chapter Changes| Pages Changed
---|---|---|---
Oct. 2023| 1.00| All – Initial Release| All
Warranty & Safety
Safety Summary
Only the XBR5100 self-contained power supply, if installed, contains dangerous
mains voltages within. Normal operation and use of the XBR5100 do not expose
the operator or service technician to high-voltage parts. The power supply is
isolated from and maybe removed safely from the main chassis. For servicing,
please return to your nearest distributor. No fuses or user-serviceable parts
are within the power supply module.
The following general safety precautions as would normally apply, should be
observed during all phases of operation, service, and repair of this
equipment.
AROUND THE EQUIPMENT
To minimize any possible shock hazard from an external power supply or
lightning strike, the chassis or equipment cabinet must be connected to an
electrical ground. This is normally achieved by the Earth grounding wire
within the 3-wire mains cable. Provide adequate ventilation around the rear of
the equipment.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the equipment in the presence of flammable gases or fumes.
Operation of any electrical equipment in such an environment constitutes a
definite safety hazard.
DO NOT ATTEMPT INTERNAL SERVICE WHILE TRANSMITTING
Thermal or RF burns may result from touching certain components within the
power amplifier module while transmitting or operating the transmitter.
DO NOT SUBSTITUTE PARTS OR MODIFY THE EQUIPMENT
Because of the danger of introducing additional hazards, do not install
substitute or lower voltage parts to the equipment. Return to your authorized
distributor.
Any modifications you make to this equipment that are not authorized by
Etherstack may invalidate your compliance authority’s approval to operate the
equipment.
EXERCISE CAUTION AND CORRECT DISPOSAL OF RF POWER DEVICES
Most RF power transistors and some RF power hybrids contain Beryllium Oxide.
Although they are normally safe, if physically damaged toxic dust may be
released. Consult your local authority for the correct disposal thereof. Such
devices are not normally used in the XBR5100.
Warranty Conditions & Precautions
The following conditions are not covered by the warranty of the XBR5100.
Please ensure that the XBR5100 is not subject to;
- Overvoltage or Reverse Power Supply Voltage.
- Operation in locations subject to abnormal environmental conditions such as extreme temperatures or ingress of moisture or excessively dusty environments.
- Operation of the XBR5100 Transmitter output into an open or short circuit or an incorrectly terminated load. Although a level of VSWR protection is included, greater protection is provided by the addition of a TX RF isolator.
Product Description
Overview
The XBR5100 series employs state-of-the-art design and construction methods to
deliver a range of high-performance, very reliable radio base stations and
repeaters. They are ideally suited for use in narrowband voice and data
communications radio systems. Fractional synthesizers’ and the two-point
modulation method give the added advantage of linear frequency and phase
response from DC to 3 kHz for accurate reproduction of voice and low-frequency
digital signaling systems.
The Receiver and Exciter circuits are contained in a single special aluminum housing together with the associated audio processing and digital control on a single circuit board. The Power Amplifier is also contained in its own extruded aluminum housing and can be easily removed from the main chassis. The XBR5100 also incorporates ‘Plug and Play’ technology and performs automatic self-calibration. A complete module changeover is field-replaceable in a very short time.
The XBR5100 employs some unique features in its design and much thought and consultation has been used to provide a product that offers an extreme degree of flexibility for the installer and service person. For example, all options may be easily field retrofitted at a later date. In addition, servicing is simplified with PCBs having all components on one side of the PCB. This permits the Technician to diagnose problems while either still connected in the chassis or powered simply and independently on the test bench. The flexibility of the XBR5100 series allows it to be configured for a wide range of applications without removing any covers.
The XBR5100 incorporates special technical features, of which the key ones are listed below:
- Extremely low conducted emissions
- Extremely low transmitter spurious
- Fast transmitter on time
- Transmitter frequency response down to DC
- Low group delay distortion
- Full subband RF switching bandwidth
- No re-tune design for receiver and transmitter
- Fully software programmable
- Built-in diagnostics
- Programmable channel spacing
- Flash upgradeable
Physical Attributes
- The XBR5100 is a compact lightweight standard 19″ rack mounting transceiver. It is designed to mount horizontally in a 19″ standard rack frame and occupies 2RU (89mm). The depth of the unit is 330mm and the weight is less than 6kg.
- The unit consists of four main sub-assemblies, the main RF assembly, a Power Amplifier Module, a Logic controller, and rear interface PCBs. These modules are housed in a sturdy steel case.
- The XBR5100 features a high degree of RFI and EMI screening throughout the design and construction. The receiver and exciter RF circuits are contained in a solid aluminum enclosure. The PA module is contained in a special compact and efficient extrusion for minimum harmonic radiation. This design results in low conducted and radiated emissions and minimal susceptibility to RFI and EMI.
- The user interface is via the rear panel sockets which include a DC power-in and USB for software programming and upgrading.
Front Panel
The XBR5100 front panel provides the user with real-time status of the
XBR5100.
Front Panel LEDs
The table below explains the functions of the front panel LEDs. Each LED
indicates the status of the XBR5100 in real-time.
LED | COLOR | FUNCTION |
---|---|---|
POWER | GREEN | Indicates the power supply voltage is within limits. No display |
indicates the voltage is not normal.
ONLINE| AMBER| Online mode is active.
HA| BLUE| High Availability mode is active.
SYSTEM| YELLOW| The system connection is active.
RX| AQUA| A wanted signal is being received by the receiver.
Digital Mode: Inbound Slot 2 is receiving
TX| RED| The transmitter is transmitting RF power.
SIMULCAST| GREEN| The transmitter is operating in simulcast mode.
ALARM| RED| A prearranged alarm condition exists.
F1| YELLOW| Reserved
F2| YELLOW| Reserved
Rear Panel
The XBR5100 rear panel provides the user with all functional connections as
well as the passive heatsink and active cooling fan.
Connector Type | Function | Description |
---|---|---|
GX25 Style Power Connector | DC Power input | 13.8V and 28V DC power input. |
N TYPE | N type RX input | The input to the receiver for full duplex operation. |
N TYPE | TX output | The RF power output from the transmitter for full duplex |
operation.
BNC| Frequency reference| 10 MHz frequency reference input.
BNC| Timing reference| 1 PPS input.
RJ45| Ethernet| Gives the base station an identity as a network element, and
provides the physical connections for the Ethernet
RJ45| Ethernet| HA mode link connection.
DB25| External I/O| Baseband and I/O.
USB| USB TYPE B| Serial Data interface.
RJ45| Spare|
XB5100 Internal Modules
The XBR5100 consists of a full duplex RF module with its own shielded metal
housing and a Main Controller board integrated on a single PCB. Using advanced
yet simplified circuit designs, the size and complexity is reduced. This
affords a number of advantages including;
- Cost reduction
- A reduced number of components improves reliability and MTBF
- Consistent and improved manufacture
- Elimination of connectors and cabling
- Reduction of human error
- Faster maintenance or swap-out
Exciter Module
- The Exciter module generates the low-level, on-frequency, RF transmitter signal which is later amplified to the nominal output power level by the Power Amplifier module. The exciter consists of a Voltage Controlled Oscillator (VCO) and associated main RF board, which, in conjunction with the reference oscillator and the PLL circuitry, forms a two-point modulation programmable frequency synthesizer. Frequency programming data is received from the microcontroller via a 3-wire serial data bus.
- The exciter circuitry features a modulation bandwidth from DC and a wide RF switching bandwidth which covers the entire sub-band. The average maximum RF output power is > +24.7 dBm / 300 mW. Normally no adjustments are required, however, should the carrier frequency need re-alignment for future maintenance, the TCXO reference oscillator frequency can be adjusted manually or electronically via software settings.
- The fractional N synthesizer provides ultra-low spirit while still maintaining fast lock times. The frequency step size is auto-determined at 5.0 kHz or 6.25 kHz.
Receiver Module
The receiver section accepts the low-level RF input signal and amplifies,
filters, and conditions the signal prior to detecting the wanted audio
component. The Receiver features the same advanced synthesizer and wide
bandwidth as the exciter. The front-end bandpass filter uses very high
tolerance components to minimize production spread variations has a wide
bandwidth and eliminates the need for future alignments. The bandwidth is
equal to the band allocation (refer to Section 9.6 for details of the band
allocations). The VCO has low-phase noise and covers the full sub-band.
The receiver has high sensitivity while maintaining excellent Intermodulation
immunity and adjacent channel rejection. A dual first IF filter provides
excellent rejection to common known spurious responses. High blocking of over
100 dB typically ensures that strong interfering signals do not desensitize
the receiver when receiving weak signals.
Micro-Controller Module
- The Micro Controller section is physically located towards the center of the main board and controls all signal connections (apart from the RF connections). It controls the operation of the RF sections and acts as the interface between the user controls, indicators, and the RF sub-sections. Together with the VF DSP chip, processed transmitted, and received audio is passed to and from the Exciter and Receiver sections as well as providing all other audio signaling functions of the transceiver.
- On onboard EEPROM stores all the user channel-related data such as transmit and receive frequencies. A serial port at the Microphone accessory socket of the XBR5100 provides access to the Controller card software configurations for the purpose of the user to create and change this channel-related information.
- Digital pots under the control of the processor ensure that the user sets up levels for TX deviation and that power levels are correctly set for each channel.
Power Amplifier Module
- The PA receives the low-level modulated RF signal from the Exciter RF output and amplifies and filters it to the final output power level. Forward and reflected power voltages are fed to the microcontroller.
- The PA is very compact and efficient for high reliability and low cost. The heatsink has a minimal temperature rise even under continuous operation, ensuring the best MTBF is obtainable for a practical design. A low-loss 13-element elliptical low pass filter ensures that harmonics remain below –90 dBc. The new PA module uses the latest LDMOS technology and using only two active RF transistors improves efficiency and increases the operating bandwidth. At the same time, this reduces the number of components used and further improves the long-term reliability.
Interface Module
- The interface module is responsible for the conversion and routing of I/O between the rear external connectors, the microcontroller module, and the front LED board.
- An FTDI module converts between the external USB and the internal serial communications interface from the Micro-Controller Module.
- PTT, alarm I/O, baseband, and RSSI signals are routed between the external I/O interface and the microcontroller module.
- LED control I/O signals are routed from the microcontroller module to the front LED board, with custom logic applied to select control signals to support dual control from the external I/O interface.
Installation & Operation
Installation
The XBR5100 Radio is securely packed for transport within a pasteboard
container. Before unpacking the XBR5100 radio, please inspect the packaging
for signs of damage and report any damage to your XBR5100 distributor.
Upon unpacking the XBR5100 radio, please ensure that all items shipped were
received, and report any missing items to your XBR5100 distributor.
Check the fan is free or does not look blocked as the operation of the radio
will be affected if any packaging or shipping damage causes the fan to stop
working.
If you intend to install the radio in an equipment rack consult the supplier’s
instructions for your system. If the radio is to be used in a stand-alone
configuration, ensure that it is in a secure, dry location with sufficient air
space around it to allow for adequate ventilation. It is recommended that the
chassis is earthed to the equipment rack.
See the product specification sheet for band-specific power requirements.
Screw Head Types
Modern screws employ a wide variety of drive designs, each requiring a
different kind of tool to drive in or extract them. Etherstack has chosen the
Pozidriv® screw head and screwdriver as its preferred screw type on all of its
products sizes 1 & 2. This is because the Pozidriv system is the choice for
high-volume assembly operations. It provides a self-centering system and
excellent driving control with less operator fatigue.
It is similar to the Phillips crosshead. The differences lie in the way that
the heads are machined. The Phillips’s head has 4 simple slots cut out of it,
whereas, in the case of the Pozidriv, each slot is the result of two machining
processes at right angles. The result of this is that the arms of the cross
are parallel-sided in the case of Pozidriv and tapered in the case of
Phillips. The Pozidriv has four additional points of contact and does not have
the rounded corners that the Phillips screwdriver has.
Phillips screwdrivers will usually work in Pozidriv screws, but Phillips screwdrivers are likely to slip or tear out the screw head when used in Pozidriv screws. It is important that you use the correct type and size screwdriver to avoid damaging the screw head.
Operation
Setting up the XBR5100 to operate in the wanted settings is straightforward
and involves one main step:
- Using a PC or handheld serial computer running standard communications terminal software, connect the PC USB port to the radio USB type B socket at the rear panel of the XBR5100. Set the appropriate parameters as required.
Note: All XBR5100s’ are set up with a standard default configuration. Test frequencies are stored within the XBR5100 as supplied by the factory; however, these are not normally accessible, and each station is supplied with no test channel.
Setting to Work
The following sections describe the steps necessary to set the XBR5100 to
operate as required.
MicroController Jumper
There are two jumpers located on the main microcontroller – J1 & CNVSS. CNVSS
is used for selecting the microcontroller operation mode. The user will not
normally have to change the position of this jumper as it is only used in the
initial factory setup. J1 is for RF power control type selection. This should
always be set to D.
Select Operating Mode
The XBR5100 can operate in a number of different modes. The primary
alternatives are a full duplex repeater, which is the default mode, and
simplex. Using the built-in radio configuration menu system, the operating
mode is programmed for each channel. When a channel is selected in operation,
the XBR5100 adopts the mode programmed for that channel.
Select Operating Channel
The XBR5100 has a channel capacity of 128. The RF frequency settings for each
channel are programmed using the radio configuration menu system channel edit
screen. The operating channel is set via a Software channel command to the
radio to select the channel. i.e CH001
Configure Alarms
The XBR5100 has an LED to display the status of alarms. The alarm trigger
conditions can be set using the built-in radio configuration menu system
software. The LED can be set to trigger on low forward power, high reflected
power, power supply voltage out of range, VCO unlocked, and high PA
temperature. The status of the alarm conditions can be expanded in the online
diagnostics mode.
Three alarm output signals are supported on the external I/O interface. Each
alarm source may be individually enabled on each of the three-alarm output
signals.
Please refer to the radio configuration menu system for additional setup
information.
Adjustments
The XBR5100 has adjustable parameters which are under the control of the Micro
Controller. These comprise of TX power, TX VCO deviation, TX reference
oscillator deviation, and TX reference oscillator frequency. All of these are
adjusted with the aid of the built-in radio Alignment menu system. The XBR5100
comes pre-aligned from the factory, so in most cases, no alignment will be
necessary.
Alignment & Testing
The XBR5100 test and alignment section assumes that the radio is a working module. Due to ongoing development, the instructions may vary please refer to the Etherstack website for updates.
Transceiver Setup, Calibration, and Alignment
This section explains how to set up, calibrate, and align the complete XBR5100
Base Station. A number of procedures are required to fully initialize the
XBR5100. The following test equipment will be needed:
- A PC with a terminal emulator to run the built-in radio configuration menu system software
- RF Test Set (HP 8920) or equivalent
- CRO (Cathode Ray Oscilloscope)
- RF Power Meter (Watts)
- RF Signal Generator
- Multimeter
- +13.8V and +28V DC power supplies (+28V is only required for the 700/800 MHz band variant)
The order of some, but not all, of the procedures is important to ensure the correct setup of the radio. The order of the procedures as described is recommended and those that are critical are mentioned. If the radio has been previously set up and the user intends to recalibrate and align the radio then steps 7.1.1, 7.1.2, and 7.1.3 can be ignored as the model number, serial number, configuration, and channel information will have already been loaded. Using a PC or handheld serial computer running standard communications terminal software, connect the device USB port to the Rear USB ‘B’ type socket at the rear panel of the XBR5100.
Setting the Model Number and Serial Number
The user cannot alter the serial and model number, as this is a factory set.
Setting the Configuration Information
Firstly, the basic configuration information for the radio needs to be set up,
this is done at the factory. Using an in-built menu system, changes to the
configuration information need to be filled out on the Configuration Screen.
Once the configuration information has been set all of the programmable
parameters within the XBR5100 Base Station are initialized.
Adding and Setting Channel Alignments
- The XBR5100 channel frequencies, subtones, and other parameters are set up in the channel edit screen of the radio Channel Edit Menu system and then downloaded to the XBR5100.
- The channel may be edited via the Channel Edit Screen of the built menu system software. The current operational channel can be selected by using the software channel select command.
- The XBR5100 comes from the factory pre-aligned, so in most cases, adjustment will not be required. The XBR5100 employs Frequency Alignment Compensation, which is setup during factory alignment. This reduces the need for individual channel alignment for Tx Power and modulation depth. If, however, adjustments are required on a particular channel this can be done via the built-in alignment menu.
Power Calibration
DO NOT USE THIS PROCEDURE TO SET THE TX OUTPUT POWER. REFER TO
TX POWER ADJUSTMENT TO DO THIS.
Power calibration affects the forward and reflected power meters on the
Diagnostics Screen. This procedure requires a power meter and the relevant
leads to connect the transmitter output to the meter. Power calibration is
done using software commands. To complete the power calibration, send the
command CALP
These readings are subsequently used for the real-time update and display of
the VSWR. The live VSWR values are used in the PA protection routines in the
firmware.
RSSI Calibration
The RSSI calibration is used to calibrate the RSSI meter on the in-built menu
system via the Diagnostics Screen. The procedure requires an RF signal
generator and the relevant leads to connect the signal generator to the RF
input of the XBR5100 Base Station. RSSI calibration is done via software
command. To complete the RSSI calibration send the command CALR
Temperature Calibration
The temperature calibration is used to calibrate the temperature meter on the
in-built menu system via the Diagnostics Screen and the temperature-controlled
switch/alarm points. The procedure requires a dummy cable for SKB on the
microcontroller having a 2060-ohm resistor between pins 4 and 6 of this
connector of the XBR5100 Base Station. Temperature calibration is done via the
software command. To complete the temperature calibration, send the command
CALT
TX Power Adjustment
The XBR5100 employs SMART PA® technology. This provides a hassle-free power
setting. This means that the user can type in a direct Power level in the
channel edit menu. E.g., 50W.
If however the required power level is not achieved a manual alignment can be
done on a per-channel basis via the alignment menu.
Peak Deviation and Modulation Balance Alignme nt
This procedure is used to set the peak deviation and modulation balance for
each channel. This is done on a per-channel basis. The alignment is done using
the Alignment Screen in the built menu system. To carry out this procedure the
demodulated output of the transmitter output needs to be connected to a CRO or
some other piece of equipment giving a visual display of the demodulated
output. IF Bandwidth of the RF test set should be set at 20kHz or greater
(230kHz on the HP 8920) and de-emphasize should be off. The audio filters
should be set at <20Hz HPF and 15kHz LPF.
The peak deviation is aligned on a wide band. The following table specifies
the peak deviation to align to.
Bandwidth | Peak Deviation (Hz) |
---|---|
Narrow (12.5kHz spacing) | 2250 |
The test tones used in this routine are generated internally and are a 1 kHz square wave for the transmitter deviation and a 400 Hz square wave for the modulation balance.
Procedure
- Using the in-built menu system, select — ALIGNMENT MENU –
- Select Tx Deviation and Modulation Balance – current channel (O)
- The radio will now transmitter.
- Follow the built-in menu system instructions.
- The transmitter will be modulated with test frequencies (1kHz, & 400Hz tone generators under microcontroller control)
- Adjust the VCO Deviation digital potentiometer using a built-in menu system until the correct deviation is obtained. (See Peak Deviation Settings).
- Adjust the Reference Deviation digital potentiometer until the top of the waveform is flat. If the waveform top droops increase the level (see Figure 7-1) and if it peaks reduce the level (see Figure 7-2).
- Repeat steps 5 through to 9 until the correct peak deviation and modulation balance are obtained.
Examples of incorrect, observed waveforms are as follows:
Choose ‘OK’ to accept the changes made. This then saves the changes that you
have made to the radio.
After balancing and setting the correct peak deviation is necessary to align
the reference oscillator and re-check the deviation alignment, as the
reference oscillator alignment affects the deviation. This may require running
through the deviation alignment again after the oscillator alignment
procedure.
TX Centre Frequency Alignment
The reference oscillator alignment is used to set the correct center frequency
for each channel. This is done on a per-channel basis. Oscillator alignment is
done using a digital potentiometer adjustment through the Built-in menu
system. To carry out this procedure the transmitter output needs to be
connected to a RF test set displaying the frequency error. This procedure
should be done after the deviation alignment procedure has been done.
Transmitter modulation we be disabled.
Select Tx Reference Oscillator and Output Power and follow the in-built menu instructions. Alter the Reference Oscillator Frequency potentiometer until the channel is “on frequency”. Choose ‘enter’ to accept the changes made. This then saves the changes that you have made to the radio.
Nominal Deviation
The required nominal deviation is dependent on whether the radio is programmed
for either narrow or wide. The following table lists the required level for
each case:
Bandwidth | FM Nominal Deviation (kHz) |
---|---|
Narrow (12.5kHz spacing) | 1.5 |
Powering
The XBR5100 is powered with 13.8V and 28V connected at the rear of the appliance. The 28V supply is only required for the 700 / 800 MHz band variant.
DC Input Pinouts
PINS | Description |
---|---|
1 | + 28V DC |
(700 / 800 MHz variant only)
2| GND
3| + 13V8 DC
Specifications
Minimum performance to exceed the following*:
- AS4295
- ETS 300 086, ETS 300 113, ETS 300 489
- FCC Part 90
- TIA/EIA-603
- CE Marking
- IC (ISED)
Conforms but may not be approved.
Consult Etherstack regarding current type approvals and for the latest and
current XBR5100 Specification Datasheet.
Operating Frequency Bands
The XBR5100 is available in a number of models which cover the range of
operating frequency bands. Refer to Section 9.6 for details of the band
breakdown.
General
Parameter | Specification |
---|---|
XBR5100 Rack Size: | 2RU Case |
XBR5100 Overall Physical Size | 89mm high, 325mm deep, 483mm wide |
- Requires extra depth (40mm) for Fan operation.
Weight| 8 kg
Supply Voltage:| 13.8V ± 20%
28V ± 20% (700 / 800 MHz Band)
Operating Temperature:| -30 to +60ºC.
Standard LED indicators:| POWER, ONLINE, HA, SYSTEM, RX, TX, SIMULCAST and
ALARM.
See 5.2.2
Frequency Range:| Model dependent.
Synthesis Method:| Nonmixing PLL Fractional N synthesizer.
Modulation:| Direct FM, two-point method
| ±2.5 kHz narrow band, ±5 kHz wide band
Channel Spacing:| 12.5 kHz, software selectable.
Synthesiser Step Size:| 5 kHz or 6.25 kHz.
Channels:| 128 Software selectable.
Transmit
See the product specification sheet.
Receive
See the product specification sheet.
Ancillaries
Parameter | Specification |
---|---|
TX Timer: | Programmable, on/off selectable. |
Channel Select: | Software Select |
Repeater Tail Timer: | Programmable. |
XBR5100 Model Number Configuration Guide
The XBR5100 build can be specified by the model number. The diagram below
shows how the model number is derived from the wanted options. Consult
Etherstack for availability details on specific configurations and options.
Due to ongoing development please refer to Etherstack for the latest revision of the specifications.
- Doc Ref: ES2304-UM01_v100a
- Date: 20 October 2023
Copyright © Etherstack Pty Ltd 2023
This is the confidential proprietary property of Etherstack Pty Ltd. This
document is protected by copyright. No part of it may be reproduced or copied
without the prior written permission of Etherstack Pty Ltd. Etherstack Pty Ltd
products are supplied under license and may be used only in accordance with
the terms of the contractual agreement between Etherstack Pty Ltd and the
license holder. All products, brand names, and trademarks referred to in this
publication are the property of Etherstack Pty Ltd or third-party owners.
Unauthorized use may constitute an infringement. Etherstack Pty Ltd reserves
the right to change information contained in this publication without notice.
All efforts have been made to ensure accuracy however Etherstack Pty Ltd does
not assume responsibility for errors or for any consequences arising from
errors in this publication.
Etherstack Proprietary Information © Etherstack Pty Ltd. 2023
Etherstack Pty Ltd 64 Rose Street Chippendale NSW 2008
AUSTRALIA
- Email :info-au@etherstack.com
- P: +61 2 8399 7500
- F: +61 2 8399 7507
- Document Version: 1.00
- Document ID: ES2304-UM01
- Author : Etherstack
- Created: 21 October, 2023
- Last Updated: 21 October, 2023
- Last Updated By: Etherstack
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>