Room Air Conditioner
Service and Parts
Manual
ZStar ™
115Volts . ZQ10A10B
PREFACE
This SERVICE MANUAL provides various service information, the mechanical and
electrical parts etc.
This room air conditioner was manufactured and assembled under a strict
quality control system.
The refrigerant is charged at the factory. Be sure to read the safety
precautions prior to servicing the unit.
1.1 SAFETY PRECAUTIONS
-
When servicing the unit, set the ROTARY SWITCH or POWER SWITCH to OFF and unplug the power cord.
-
Observe the original lead dress.
If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. -
After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards.
1.2 INSULATION RESISTANCE TEST
- Unplug the power cord and connect a jumper between 2 pins (black and white).
- The grounding conductor (green or green & yellow) should be open.
- Measure the resistance value with an ohm meter between the jumped lead and each exposed metallic part on the equipment at all the positions (except OFF or O) of the ROTARY SWITCH.
- The value should be over 1MΩ .
MODELS /ITEMS| Z010A10B
---|---
POWER SUPPLY| 1o, 115V, 60Hz
COOLING CAPACITY (Bluff)| 10,000
INPUT (W)| 1,020
RUNNING CURRENT (A)| 9.2
E.E.R (Btu/W.h)| 9.2
OPERATING TEMPERATURE| INDOOR (C)| 26.7(DB) 19.4(WB)**
OUTDOOR (QC)| 35(DB) 23.9(WB)
REFRIGERANT (R-22) CHARGE| 439g (15.5 oz)
EVAPORATOR| 3 ROW 14 STACKS, S-FIN TYPE
CONDENSER| 2 ROW 16 STACKS, L-BENDED TYPE
FAN, INDOOR| TURBO FAN
FAN, OUTDOOR| PROPELLER TYPE FAN WITH SLINGER-RING
FAN SPEEDS, FAN/COOLING| 2/3
FAN MOTOR| 6 POLES
OPERATION CONTROL| ROTARY SWITCH
ROOM TEMP. CONTROL| THERMOSTAT
AIR DIRECTION CONTROL| VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
CONSTRUCTION| SLIDE IN-OUT CHASSIS
PROTECTOR| COMPRESSOR| OVERLOAD PROTECTOR
FAN MOTOR| INTERNAL THERMAL PROTECTOR
POWER CORD| 1.8m(7′) (3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN SYSTEM| DRAIN PIPE OR SPLASHED BY FAN SLINGER
NET WEIGHT (lbsikg)| 70/32
OUTSIDE DIMENSION WxHxD)| inch| 18Wx 137/ex 2011/4
mm| 470 x 353 x 525
- DB : dry bulb
** WB : wet bulb
1.4 FEATURES
- Designed for cooling only.
- Powerful and whisper cooling.
- Slide-in and slide-out chassis for the simple installation and service.
- Side air-intake, side cooled-air discharge.
- Built in adjustable THERMOSTAT.
- Washable one-touch filter.
- Compact size.
- Reliable and efficient rotary compressor equipped.
1.5 CONTROL LOCATIONS
1.5.1 CONTROL ONLY MODEL
-
VENTILATION
The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position.
The damper is opened and room air is exhausted. NOTE
Before using the ventilation feature, make a ventilation kit. First, pull down part to horizontal line with part . -
FOR NORMAL COOLING
1. Turn the Mode switch to the High, Med or Low Cool setting.
2. Set the Temperature control to the desired temperature point (the mid- point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate. -
FOR MAXIMUM COOLING
1. Turn the Mode switch to the High Cool setting.
2. Set the temperature control to the highest temperature point (all the way to the right). -
FOR QUIETER OPERATION
1. Turn the Mode switch to the Low Cool setting.
2. Set the Temperature control as needed. -
Energy Saver Switch
This rocker switch can be depressed to either YES or NO. In the YES position, you will get the most economical operation. Both the fan and the compressor will cycle on and off together, maintaining the selected temperature at a more constant level and reducing the humidity more efficiently. This control will only operate when the unit is in a cooling mode. In the NO position, the fan will run constantly as long as the unit is in the cooling mode.
DISASSEMBLY INSTRUCTIONS
— Before disassembling, turn the POWER SWITCH to OFF and disconnect the power
cord.
2.1 MECHANICAL PARTS
2.1.1 FRONT GRILLE
- Open the INLET GRILLE downward and remove the air filter.
- Remove the screw which fastens the FRONT GRILLE.
- Pull the FRONT GRILLE from the right side.
- Remove the FRONT GRILLE.
- Re-install the component by referring to the above removal procedure. (See figure 1)
2.1.2 CABINET
- After disassembling the FRONT GRILLE, remove two screws which fasten the CABINET at both sides.
- Remove two screws which fasten the CABINET at back.
- Pull the BASE PAN forward. (See figure 2)
2.1.3 CONTROL BOX
- Disconnect the unit from the power source.
- Remove the front grille. (Refer to section 2.1.1)
- Remove the cabinet. (Refer to section 2.1.2)
- Remove the screw which fastens the control box cover.
- Remove the housing which connects motor wire in the control box.
- Remove the 3 leads from the compressor. (Refer to section 2.3.1)
- Discharge the capacitor by placing a 20,000 ohmresistor across the capacitor terminals.
- Remove the 2 screws which fasten the control box.(See Figure 3)
- Pull the control box forward completely.
- Re-install the components by referring to the removal procedure, above. (See Figure 3) (Refer to the circuit diagram found on page 24 in this manual or on the control box.)
2.2 AIR HANDLING PARTS
2.2.1 AIR GUIDE AND BLOWER
- Remove the front grille. (Refer to section 2.1.1)
- Remove the cabinet. (Refer to section 2.1.2)
- Remove the control box. (Refer to section 2.1.3)
- Remove the 3 screws which fasten the brace.
- Remove the brace.
- Remove the 2 screws which fasten the evaporator.
- Move the evaporator forward and pulling it upward slightly. (See Figure 4)
- Move the evaporator to the left carefully.
- Pull out the hook of orifice by pushing the tabs and remove it. (See Figure 5)
- Remove the clamp with a hand plier which secures the blower.
- Remove the blower.
- Remove the 4 screws which fasten the air guide from the barrier.
- Move the air guide backward, pulling out from the base pan.
- Re-install the components by referring to the removal procedure, above.
2.2.2 FAN AND SHROUD
- Remove the cabinet. (Refer to section 2.1.2)
- Remove the brace (Refer to section 2.2.1)
- Remove the screw which fastens the cover cond.
- Remove the 5 screws which fasten the condenser.
- Move the condenser to the left carefully.
- Remove the clamp with a hand plier which secures the fan.
- Remove the fan and then pull out the shroud. (See Figure 6)
- Re-install the components by referring to the removal procedure.
2.3 ELECTRICAL PARTS
2.3.1 OVERLOAD PROTECTOR
- Remove the cabinet. (Refer to section 2.1.2)
- Remove the nut which fastens the terminal cover.
- Remove the terminal cover. (See Figure 7)
- Remove all the leads from the overload protector.
- Remove the overload protector.
- Re-install the component by referring to the removal procedure, above.
2.3.2 COMPRESSOR
-
Remove the cabinet. (Refer to section 2.1.2)
-
Discharge the refrigerant system using a Freon Recovery System.
If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon ™. Leave the valve in place after servicing the system. -
Remove the overload protector. (Refer to section 2.3.1)
-
After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.
-
Remove the 3 nuts and the 3 washers which fasten the compressor.
-
Remove the compressor. (See Figure 8)
-
Re-install the components by referring to the removal procedure, above.
2.3.3 CAPACITOR
- Remove the control box. (Refer to section 2.1.3)
- Remove the knobs and the screw which fasten control panel from control box.
- Remove the screw which is located in the front.
- Open the bottom side of control box.
- Remove the screw and the clamp which fasten the capacitor.
- Disconnect all the leads of capacitor terminals.
- Re-install the components by referring to the removal procedure, above. (See Figure 9)
2.3.4 POWER CORD
-
Remove the control box. (Refer to section 2.1.3)
-
Open the control box. (Refer to section 2.3.3)
-
Disconnect the grounding screw from the control box.
-
Disconnect the 2 receptacles.
-
Remove a screw which fastens the clip cord. (See Figure 10)
-
Remove the power cord.
-
Re-install the component by referring to the above removal procedure, above.
(Use only one ground-marked hole for ground connection.) -
If the supply cord of this appliance is damaged, it must be replaced by the special cord. (The special cord means the cord which has the same specification marked on the supply cord attached at the unit.)
2.3.5 THERMOSTAT
- Remove the control box. (Refer to section 2.1.3)
- Open the control box. (Refer to section 2.3.3)
- Remove the 2 screws which fasten the thermostat.
- Disconnect 2 leads of thermostat terminals.
- Remove the thermostat.
- Re-install the components by refereing to the above removal procedure. (See Figure 11)
2.3.6 ROTARY SWITCH
- Remove the control box. (Refer to section 2.1.3)
- Open the control box. (Refer to section 2.3.3)
- Remove the 2 screws which fasten the rotary switch.
- Disconnect all the leads of the rotary switch terminals.
- Remove the rotary switch.
- Re-install the components by referring to the above removal procedure. (See Figure 12)
2.3.7 MOTOR
- Remove the cabinet. (Refer to section 2.1.2)
- Remove the evaporator. (Refer to section 2.2.1)
- Remove the orifice. (Refer to section 2.2.1)
- Remove the blower. (Refer to section 2.2.1)
- Remove the fan. (Refer to section 2.2.2)
- Remove the control box cover and housing of the motor in the control box. (Refer to section 2.1.3)
- Remove the 2 screws which fasten the motor from the mount motor. (See Figure 13)
- Remove the motor.
- Re-install the components by referring to the removal procedure, above.(See Figure 13)
2.4 REFRIGERATING CYCLE
CAUTION
Discharge the refrigerant system using a Freon™ Recovery System.
If there is no valve to attach the recovery system, install one (such as a
WATCO A-1) before venting the Freon™ . Leave the valve in place after
servicing the system.
2.4.1 CONDENSER
- Remove the cabinet. (Refer to section 2.1.2)
- Remove the 3 screws which fasten the brace.(Refer to section 2.2.1)
- Remove the screw which fastens the cover cond.
- Remove the 5 screws which fasten the condenser and shroud.
- After discharging the refrigerant completely, unbrace the interconnecting tube at the condenser connections.
- Remove the condenser carefully.
- Re-install the components by referring to the removal procedure. (See Figure 14)
2.4.2 EVAPORATOR
-
Remove the cabinet. (Refer to section 2.1.2)
-
Remove the 2 screws which fasten the evaporator.
-
Move the evaporator sideways carefully.
(Refer to section 2.2.1) -
After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.
-
Remove the evaporator carefully.
-
Re-install the component by referring to notes. (See Figure 15)
2.4.3 CAPILLARY TUBE
- Remove the cabinet. (Refer to section 2.1.2)
- After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.(See caution above)
- Remove the capillary tube.
- Re-install the component by referring to notes.
NOTES
— Replacement of the refrigeration cycle.
-
When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon recovery System.
If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon™ . Leave the valve in place after servicing the system. -
After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes.
-
Solder service valves into the pinch-off tube ports, leaving the valves open.
-
Solder the pinch-off tubes with Service valves.
-
Evacuate as follows.
- Connect the vacuum pump, as illustrated figure 16A.
- Start the vacuum pump, slowly open manifold valves A and B with two full
turns counterclockwise and leave the valves open.
The vacuum pump is now pulling through valves A and B up to valve C by means of the manifold and entire system.
CAUTION
If high vacuum equipment is used, just crack valves A and B for a few minutes, then open slowly with the two full turns counterclockwise.
This will keep oil from foaming and being drawn into the vacuum pump. - Operate the vacuum pump for 20 to 30 minutes, until 600 microns of vaccum is obtained. Close valves A and B, and observe vacuum gauge for a few minutes. A rise in pressure would indicate a possible leak or moisture emaining in the system. With valves A and B closed, stop the vacuum pump.
- Remove the hose from the vacuum pump and place it on the charging cylinder.
See figure 16B.
Open valve C.
Discharge the line at the manifold connection. - The system is now ready for final charging.
- Recharge as follows :
- Refrigeration cycle systems are charged from the High-side. If the total charge cannot be put in the High-side, the balance will be put in the suction line through the access valve which you installed as the system was opened.
- Connect the charging cylinder as shown in figure 16B.
With valve C open, discharge the hose at the manifold connection. - Open valve A and allow the proper charge to enter the system. Valve B is still closed.
- If more charge is required, the high-side will not take it. Close valve A.
- With the unit running, open valve B and add the balance of the charge.
a. Do not add the liquid refrigerant to the Lowside.
b. Watch the Low-side gauge; allow pressure to rise to 30 lbs.
c. Turn off valve B and allow pressure to drop.
d. Repeat steps b. and c. until the balance of the charge is in the system. - When satisfied the unit is operating correctly, use the pinch-off tool with the unit still running and clamp on to the pinch-off tube. Using a tube cutter, cut the pinch-off tube about 2 inches from the pinch-off tool. Use sil-fos solder and solder pinch-off tube closed. Turn off the unit, allow it to set for a while, and then test the leakage of the pinch-off connection.
Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
INSTALLATION
3.1 INSTALLATION HARDWARE
3.2 SELECT THE BEST LOCATION
Step 1. To prevent vibration and noise, make sure the unit is installed
securely and firmly
Step 2. If possible, install the unit where sunlight does not shine directly
on the unit.
Step 3. The outside of the cabinet must extend outward for at least 11″ and
there should be no obstacles, such as a fence or wall, within 20″ from the
back of the cabinet because it will prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling efficiency of the
air conditioner.
Step 4. Install the unit with a little tilt outward not to leak the condensed
water into the room (about 10~15cm or 1/4 bubble with level).
CAUTION : All side louvers of the cabinet must remain exposed to the
outside of the structure.
3.3 WINDOW REQUIREMENTS
Step 1. These instructions are for a standard double hung window. You will
need to modify them for other types of windows.
Step 2. The air conditioner can be installed without the frame curtain if
needed to fit in a narrow window.
See the window opening dimensions to the right.
Step 3. All supporting parts must be secured to firm wood, masonry, or metal.
Step 4. The electric outlet must be within reach of the power cord.
3.4 STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the
outside and will keep it from draining properly.
To adjust for this, attach a piece of wood to the stool.
WOOD PIECES–
Width: Minimum 1 1/2″(38mm)
Length: Long enough to fit inside the window frame.
Thickness: To determine the thickness, place a piece of wood on the stool to
make it 1/2″ higher than the top of the storm window frame.
Attach securely with nails or screws provided.
3.5 PREPARING THE UNIT FOR INSTALLATION
✓ Remove the 2 shipping screws from the back of the case. ✓ Remove the 2
screws on each side of the case.
Keep these for later use. ✓ Slide the air conditioner from the case by
gripping the base pan handle and pulling forward while bracing the case.
3.6 BEFORE INSTALLATION…
✓ Cut the window sash seal to the proper length. Peel off the backing and
attach the seal to the underside of the window sash. ✓ Carefully insert the
plastic frame guides into the bottom of the case on each side.
When the frame guides are set, the arrows should be pointing toward the back
end of the unit. ✓ Insert the frames for the frame curtains into the top
mounting rail and the frame guides. Attach the frame curtains to the side of
the case using 4 type A screws
3.7 INSTALL THE CASE IN THE WINDOW
Step 1. Open the window and mark the centerline of the window stool (or
desired air conditioner location).
Step 2. Carefully place the case on the window stool and align the center mark
on the bottom front with the centerline of the stool
Step 3. Pull the window down behind the top mounting rail
NOTE: Do not shut the window so tightly that movement of the frame curtains is
restricted.
Step 4. Loosely assemble the sill supports.
Step 5. Select the position that will place the sill supports near the
outermost point on the sill.
Attach the sill supports to the case track hole in relation to the selected
position using 2 type A screws in each support. Step 6. Adjust the bolt and
the nut in each support so that the case is installed with a slight downward
tilt (about 1/2″).
Step 7. Secure the case to the window stool by using 3 type B screws.
Step 8. Pull the frame curtains to each window sash track. Attach them on each
side to the window sash and the window stool using 4 type C screws.
3.8 INSTALL THE WINDOW LOCKING BRACKET AND THE FOAM TOP WINDOW GASKET
Step 1. Attach the window locking bracket with type C screw.
Step 2. Cut the foam top window gasket to the window width.
Step 3. Stuff the foam between the glass and the window to prevent air and
insects from getting into the room. 3.9 INSTALL THE AIR CONDITIONER IN THE
CASE
Step 1. Slide the air conditioner into the case. Reinstall the2 screws removed
earlier on each side of the case.
Step 2. Before installing the front grille, pull out the vent control lever
located above the unit control knobs, as shown.
Step 3. Attach the front grille to the case by inserting the tabs on the
grille into the slots on the front of the case. Push the grille in until it
snaps into place.
When you detach the front grille from the case, push the grille to your right
side and pull it toward you.
Step 4. Lift the inlet grille and secure the front grille with a type A screw.
Lower the inlet grille into place.
3.10 TO REVERSE THE GRILLE OPENING
The Friedrich ZQ08A10A has a reversible grille. The grille is designed to open
from both the top and the bottom.
To reverse the grille opening, you must follow the following steps;
Step 1. Pull the entire grill of the front of the unit and locate the hinges
that hold the grille in place on the inside of the grille.
Step 2. Insert the tip of a flat screwdriver in between one of the Hinges and
the ball shaped bearing of the grille.
Step 3. Very carefully pull the bearing out of the socket of the Hinge and
repeat steps 1-3 for the remaining hinge and socket.
Step 4. Locate the top hinges on the grille.
Step 5. Turn the grille upside down and using flat screwdriver, create an
opening on the top hinge and insert the ball shaped bearing to snap the grille
in place. Repeat the same steps on the remaining hinge.
TROUBLESHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS
4.2 PIPING SYSTEM
Discharge the refrigerant system using a Freon Recovery System. If there is no
valve to attach the recovery system, install one (such as a WATCO A-1) before
venting the Freon TM.
Leave the valve in place after servicing the system. Do not vent Freon TM into
the atmosphere.| →: REFRIGERANT FLOW
---|---
The following is a brief description of the important components and their function in what is called the refrigeration system. Reference should made to figure 17 to follow the refrigerating cycle and the flow of the refrigerant in the cooling cycle.
ROOM AIR CONITIONER
CYCLE OF REFRIGERATION
4.3 TROUBLESHOOTING GUIDE
In general, possible trouble is classified in two kinds.
The one is called Starting Failure which is caused from an electrical defect.
The other is Ineffective Air Conditioning caused by a defect in the
refrigeration circuit and improper application.
Unit runs but poor cooling is ineffective.
ROOM AIR CONDITIONER VOLTAGE LIMITS
NAME PLATE RATING | MINIMUM | MAXIMUM |
---|---|---|
115V | 103.5V | 126.5V |
COMPLAINT | CAUSE | REMEDY |
--- | --- | --- |
Fan motor will not run. | No power | Check voltage at outlet. Correct if none. |
Power supply cord | Check voltage to rotary switch. If none, check power supply |
cord. Replace cord if circuit is open.
Rotary switch| Check switch continuity. Refer to wiring diagram for terminal
identification. Replace switch if none defective.
Wire disconnected or connection loose| Connect wire. Refer to wiring diagram
for terminal identification. Repair or replace loose terminal.
Capacitor (Discharge capacitor before testing.)| Test capacitor.
Replace if not within ±10% of manufacturer’s rating. Replace if shorted, open, or damaged.
Will not rotate| Fan blade hitting shroud or blower wheel hitting scroll. Realign assembly.
Units using slinger ring condenser fans must have 2/9 to 1/4 inch clearance to the base. If it is the base, shim up the bottom of the fan
motor with mounting screw(s).
Check fan motor bearings; if motor shaft will not rotate, replace the motor.
Fan motor runs intermittently.| Revolves on overload.| Check voltage. See limits on this page. If not within limits, call an electrician.
**** Test capacitor.
Check bearings. Does the fan blade rotate freely? If not, replace fan motor.
**** Pay attention to any change from high speed to low speed. If the speed does not change, replace the motor.
Fan motor noise.| Fan| If cracked, out of balance, or partially missing,
replace it.
---|---|---
Blower| If cracked, out of balance, or partially missing, replace it.
Loose set screw| Tighten it.
Worn bearings| If knocking sounds continue when running or loose, replace the
motor. If the motor hums or noise appears to be internal while running,
replace motor.
Compressor will not run, fan motor runs.| Voltage| Check voltage. See the
limits on the preceding page. If not within limits, call an electrician.
Wiring| Check the wire connections ; if loose, repair or replace the terminal.
If the wires are disconnected, refer to wiring diagram for identification, and
replace the wires. Check the wire connections ; if not according to the wiring
diagram, correct the connections.
Rotary| Check for continuity, refer to the wiring diagram for terminal
identification. Replace the switch if the circuit is open.
Thermostat| Check the position of knob. If not at the coldest setting, advance
the knob to this setting and restart the unit.
Check the continuity of the thermostat. Replace the thermostat if the circuit
is open.
Capacitor (Discharge capacitor before servicing.)| Check the capacitor.
Replace if not within ±10% of manufacturer’s rating, replace if shorted, open, or damaged.
Compressor| Check the compressor for open circuit or graond. If open or
grounded, replace the compressor.
Overload| Check the compressor overload if externally mounted.
Replace if open. (If the compressor temperature is high, remove the overload, cool and retest.)
Compressor cycles on overload.| Voltage| Check the voltage. See the limits on
the preceding page. If voltage is not within these limits, call an
electrician.
Overload| Check overload, if externally mounted.
Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.)
Compressor cycles on overload| Fan motor| If not running, determine the cause.
Replace if required.
---|---|---
Condenser air flow restriction| Remove the cabinet, inspect the interior
surface of the condenser. If restricted, clean carefully with a vacuum cleaner
(do not damage fins) or brush.
Clean the interior base before re-assembling.
Condenser fins (damaged)| If the condenser fins are closed over a large area on the coil surface, head pressures will increase, causing the compressor to cycle.
Straighten the fins or replace the coil.
Capacitor| Test the capacitor.
Wiring| Check the terminals. If loose, repair or replace.
Refrigeration system| Check the system for a restriction.
Insufficient cooling| Air filter| If restricted, clean or replace.
Exhaust damper door| Close if open.
Unit undersized| Determine if the unit is properly sized for the area to be
cooled.
Excessive noise| Blower or fan| Check the set screw, or clamp. If loose or
missing, correct. If the blower or fan is hitting scroll or barrier, rearrange
the air handling parts.
Copper tubing| Remove the cabinet and carefully rearrange the tubing not to
contact the cabinet, compressor, shroud and barrier.
SCHEMATIC DIAGRAM
- CIRCUIT DIAGRAM
- MODEL : ZQ10A10B
LOCATION NO.| **DESCRIPTION| PART NO.| Q’TY PER SET| **
REMARKS
---|---|---|---|---
ZQ10A10A
1| POWER CORD ASS’Y| 2H00677R| 1|
2| MOTOR ASS’Y| 4681A20027J| 1|
3| COMPRESSOR| 2520UKEC2CB| 1|
4| ROTARY SWITCH| 2H00598E| 1|
5| THERMOSTAT| 2H01109L| 1|
6| CAPACITOR, SH| 0CZZA20001N| 1|
7| CONNECTOR ASS’Y| 6631AR3843P| 1|
9| CONNECTOR ASS’Y| 6631AR2687R| 1|
10| OVERLOAD PROTECTOR| 6750U-L049A| 1|
EXPLODED VIEW
REPLACEMENT PARTS LIST
• MODEL: ZQ10A10B
LOCATION NO .| FRIEDRICH PART NO.| ****
DESCRIPTION
| PART NO.| Q’TY PER SET| ****
REMARK
---|---|---|---|---|---
ZQ10A10B
A| 673-060-02| FRONT GRILLE ASSY| 3531A20034C| 1| R
1| 673-044-02| FRONT GRILLE| 3530A10026A| 1| R
2| 673-061-01| INLET GRILLE| 3530A10028A| 1| R
3| 673-043-02| AIR FILTER ASSY| 5231A20004A| 1| R
4| 673-062-01| LOUVER, HORIZONTAL| 4758A20002A| 1| R
5| 673-062-50| VERTICAL LOUVER| 4758A30008A| 2| R
6| 673-037-03| CABINET ASSY| 3091A30005C| 1| R
B| | COMP & ACCESSORY ASSY| | |
7| | ANTI-VIBRATION BUSH| 4830AR4335A| 3| R
8| | COMPRESSOR| 2520UKLC2CA| 1| R
9| 673-018-00| BRACKET, WASHER| 4810AR4155B| 3| N
10| 673-017-00| HEXAGON NUTS| 1NHA0801206| 3| N
11| | GASKET| 4986U-L001G| 1| R
12| | OVERLOAD PROTECTOR| 6750U-L031A| 1| R
13| | TERMINAL COVER| 3550U-L006A| 1| R
14| 673-011-00| GASKET-NUT| 4H01058A| 1| R
15| 673-010-00| NUT, TERMINAL COVER| 4H00947A| 1| R
16| | BASE PAN WELD ASSY| 3041A30005P| 1| R
17| 673-068-00| BARRIER, SINGLE| 4790A10008A| 1| R
18| | SCROLL| 3072A20004A| 1| R
19| | AIR GUIDE| 5238A10006A| 1| R
20| 673-035-02| VENTILATION DAMPER| 4901A30001A| 1| R
21| | MOTOR MOUNT| 4960A20014A| 1| R
22| | MOTOR ASSY| 4681A20027J| 1| R
23| 673-069-01| SCREW| 4000W4A003A| 2| N
24| 673-069-00| SCREW, TAP| 4H00006D| 4| N
25| | COVER, COND.| 3550A30064A| 1| R
26| | SHROUD| 4998A10010A| 1| R
27| | FAN, TURBO| 5900A20016A| 1| R
28| | FAN| 5900A20015A| 1| R
29| 673-025-00| CLAMP SPRING| 3H02932B| 2| R
30| | ORIFICE| 4948A30007A| 1| R
31| 673-039-01| BRACE| 4800A30001A| 1| R
32| | EVAPORATOR ASSY| 5421A20061F| 1| R
33| | CONDENSER ASSY| 5403A20043B| 1| R
34| 673-071-00| RUBBER| 4H02023A| 1| R
C| | CONTROL BOX ASSY| 4995A20118N| 1| R
---|---|---|---|---|---
35| 673-054-01| CONTROL BOX, SINGLE| 4994A10006B| 1| R
36| 673-055-01| CONTROL PANEL ASSY| 3721A20037B| 1| R
37| 673-041-03| KNOB ASSY| 4941A30011A| 2| R
38| | CAPACITOR| 0CZZ20001V| 1| R
39| 673-006-00| CAPACITOR CLAMP| 4H00442N| 1| R
40| | POWER CORD ASSY| 2H00677R| 1| R
41| 673-004-02| THERMOSTAT| 2H01109L| 1| R
42| 673-005-01| ROTARY SWITCH| 2H00598E| 1| R
43| 673-057-01| ROCKER SWITCH| 2H01316C| 1| R
44| | CLIP CORD| 4H01762A| 1| R
45| 673-003-62| LEAD WIRE ASSY| 6631AR2687A| 1| R
46| | CONDUCT ASSY| 6631AR3843P| 1| R
47| | COVER, CONTROL BOX| 3550A30036B| 1| R
D| | PIPE| | |
48| | SUCTION TUBE ASSY| 5211A20130R| 1| R
49| | DISCHARGE TUBE| 5211AR2930Z| 1| R
50| | TUBE EVAPORATOR| 5210A21847A| 1| R
51| | TUBE EVAPORATOR| 5210A20847B| 1| R
52| | TUBE ASSY, CONNECTOR| 5211AR7059Y| 1| R
53| | CAPILLARY| 5211A20598B| 1| R
54| | DRIER ASSY| 5851A30001F| 1| R
E| 673-063-03| INSTALL PART ASSY| 3127AR3403M| 1| R
55| 673-040-02| UPPER GUIDE| 5210AR3196F| 1| R
56| 673-038-02| CURTAIN ASSY| 4959AR3402A| 1| R
57| 673-038-03| CURTAIN ASSY| 4959AR3402B| 1| R
58| 673-065-00| BRACKET, ANGLE| 4810AR3240A| 2| R
59| 673-067-00| NUT, HEXAGON| 1NHC1000006| 2| R
60| 673-066-00| BOLT| 1BHD1004006| 2| R
61| 673-064-00| FRAME GUIDE| 3210AR3337A| 2| R
62| 673-069-02| WASHER, PLAIN| 4H01029D| 1| R
63| 673-070-00| DRAIN, PIPE| 3H02773A| 1| R
Use Factory Certified Parts…
FRIEDRICH AIR CONDITIONING CO.
Visit our web site atwww.friedrich.com
Post Office Box 1540 • 4200 N. Pan Am Expressway
• San Antonio, Texas 78295-1540
•210-357-4400 • FAX
210-357-4480
P/NO.: 3828A20038V
ZQ10 (03/01)Printed in the U.S.A