The Positive Input Ventilation for Flats & Apartments is designed to introduce
fresh, filtered air throughout the living space, transforming a stagnant and
stale atmosphere into a fresh, healthy, and condensation-free environment. It
offers various
features and benefits including reducing or eliminating surface condensation,
quiet operation, eliminating mold, stopping streaming windows, removing musty
odors, improving air quality, benefiting asthma sufferers, low running costs,
exceptionally lightweight design (just 5Kg), integral intelligent comfort
heater (as standard), ultra-low watt DC motor technology, app-enabled version]
available to connect to the myenvirovent App, extremely low profile] (just
16cm), and a 10-year guarantee.
Instructions
About ATMOS®
The ATMOS® WALL Unit is an energy efficient condensation-control unit for
flats and apartments.
It introduces fresh, filtered air throughout the living space to transform a
stagnant and stale atmosphere into a fresh, healthy and condensation free
environment.
Features & Benefits
- Reduces/eliminates surface condensation Quiet operation
- Eliminates mould
- Stops streaming windows
- Removes musty odours
- Improves air quality
- Benefits asthma sufferers
- Low running costs
- Exceptionally lightweight, just 5Kg
- Integral intelligent comfort heater (as standard)
- Ultra Low Watt DC motor technology
- ATMOS® Remote Control Boost version available
- App-enabled version available to connect to the myenvirovent App
- Compatible with the AirSens® range of Indoor Air Quality Sensors
- Extremely low profile, just 16cm
- 10 year guarantee
Energy Saving Benefits
Minimum Energy Consumption ATMOS® WALL is designed with the latest low watt motor technology to ensure minimum energy consumption and long term trouble- free life.
Reduce Heat Loss
To reduce humidity and condensation during the heating season, signifi cant energy loss occurs by opening windows. ATMOS® WALL provides fresh, filtered air into the home, displacing humid air reducing the need to open windows and mitigating heat loss.
The ATMOS® 10-Year Warranty
All products in the ATMOS® range come with our extended 10-year warranty. Any repairs needed within 10 years will be completed free of charge. All we ask is that you change the fi lter for ATMOS® Wall every 12 months. This period may be shorter depending on the environmental conditions. The ATMOS® wall unit needs to be serviced after 5 years.
User Friendly
The ATMOS® WALL unit is available with the myenvirovent App (ATF-A), designed to offer total control of the unit from anywhere in the home at the touch of a button.\
- Filter indicator
- Adjustable boost functionality
- Hours run meter
- Adjustablairfl ow
- Adjustable heater
- Control summer mode
- Enable or disable the heater
ATMOS® Remote Control
The ATMOS® units can be controlled with a remote control boost switch to increase the airflow ow when required (Order code -W).
AirSens®
For those who like to keep an eye on air quality levels, Arisen® provides an
east-read color-coded display, showing the current air quality at any time:
Red – Poor air quality
Amber – Medium air quality
Green – Good air quality
Available in three models, AirSens® can detect and control levels of
- Carbon Dioxide (CO2)
- Volatile Organic Compounds (VOCs)
- Relative Humidity
ATMOS® WALL can be linked directly to the AirSens® sensor. This means it reacts automatically to changes in air quality, instantly supplying more fresh air into the property to maintain a healthy environment when needed.
Install Friendly
ATMOS® WALL has been designed for utmost ease of installation in mind. With an extremely low profile of 16cm and weighing just 5kg, it can be wall or ceiling mounted with just four fixing points.
Product Code
- ATMOS® WALL Standard ATF
- ATMOS® WALL App-Enabled ATF-A
- ATMOS® WALL Remote Controlled Boost Switch ATF-W
Filter Options
ISO ePM10 50%
FILTERWALL-MEDIUM (Default)
ISO ePM2.5 50%
FILTERWALL-FINE
ISO ePM2.5 50% including carbon FILTERWALL-FINE+C
Health Benefits
With improved building features in our homes, such as cavity wall insulation,
double glazing and draught proof ng, ‘natural ventilation’ is prohibited.
Stale air is trapped causing streaming windows, which ultimately leads to
musty smells, dampness and mold growth. These mold spores are known allergens
and become airborne at the slightest disturbance. The microscopic spores are
then inhaled and can trigger respiratory problems such as asthma, dust
allergies and hay fever.
The ATMOS® WALL Unit draws fresh air into the dwelling from outside and fi liters it before being delivered into the property. Moisture laden air is diluted, displaced and replaced with clean, tempered and filtered air. This eliminates or reduces surface condensation, which causes mold growth, providing a signify cant improvement in the health of asthma sufferers and general indoor air quality.
Pre-Heater and Hours Run Meter
The integral pre-heater is designed to temper the incoming air during periods of low external temperatures. A sensor monitors incoming air and pulses the heater to ensure temperatures are held to pre-set minimums. Two independent safety cut-out devices shut down the heater in the event of fan failure. The heater facility is controlled independently from the fan by a conveniently positioned enable/disable switch (optional extra – code SWHHEATER). For monitoring of operational life and verification of usage, an integral Hours Run Meter is fitted.
Annual Running Costs
Please scan our QR code to see the annual running costs of this product.
Or visit
envirovent.com/annual-runningcos ts
Technical Specifications
Applications – The ATMOS® WALL mounted unit is manufactured in the UK and is designed for installation into flats and apartments to meet the Building Regulations Approved Document F. ATMOS units supply filtered air from outside into a central location within the property at a continuous rate. Air is supplied via a grille that is designed to maximize the efficiency of airflow. The unit provides ventilation in order to improve indoor air quality and resolve condensation related problems such as damp and mold.
Motor – Designed to operate continuously at a pre-set rate, incorporating DC
motor technology with sealed for life ball bearings.
Filter – The unit has an ePM10 50% synthetic fi bre based fi lter, tested in
accordance with the ISO 16890 standard.
Servicing / Maintenance
Filter change is required every 12 months, This period may be shorter
depending on the environmental conditions. The ATMOS® wall unit needs to be
serviced after 5 years, various service options. Any old components may be
returned for recycling.
Standard Functions
Integral ‘Intelligent Low Temperature’ comfort heater. Designed to temper the
air during periods of low external temperatures.
Controls
At installation, the unit will be set by the installer using the integrated
control panel to run at one of the 4 fixed speeds (1,2,3,4) depending on the
size and occupancy of the property, a variable speed option is also available.
The unit will run continuously all year round on this setting. An integral
hours run meter is fitted on all units for monitoring of operational life and
verification of usage.
Optional controls
Model ATF-W – These units are supplied with a wireless remote control. The user can view the current status of the unit, increase or decrease the airflow as required and enable/disable the auto comfort heater.
Model ATF-A
These units are app-enabled. Once the user activates the boost switch in the
myenvirovent app, the airflow is boosted for 20 minutes (default time period)
before returning to the commissioned setting. Other functions within the
myenvirovent app include: Airflow setting, Filter change indicator, Hours run
meter, Auto comfort heater enable/disable.
0-10V variable control input for use with the AIRSENS® is available on both W and A versions.
Warranty
Covered by a 10 year warranty, subject to the completion of specified
maintenance.
UK Building Regulations
Conforms to the requirements of the UK Building Regulations and the Technical
Standards for Ventilation.
Conforms to requirements of the EC and UK directives.
Accreditations – CE and UKCA Marked.
Performance Curve
Performance curve results are based on the unit running below 19°C and exclude ancillaries.