CONDENSING GAS FURNACE
OWNER’S MANUAL
NOTE: Read the entire instruction manual before starting the installation.
Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.
NOTE: To the Installer: This manual must be left with the equipment user.
USER: Please read all instructions in the manual and retain all manuals for
future reference
A11264
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in
the program.
For verification of certification for individual products, go to
www.ahridirectory.org.
A200104
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in personal injury,
death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
– If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury and/or death.
Carbon Monoxide (CO) is a colorless, odorless, and tasteless poisonous gas
that can be fatal when inhaled. Follow all installation, maintenance, and
service instructions. See additional information below regarding the
installation of a CO Alarm.
Most states in the USA and jurisdictions in Canada have laws that require the use of Carbon Monoxide (CO) alarms with fuel burning products. Examples of fuel burning products are furnaces, boilers, space heaters, generators, water heaters, stoves/ranges, clothes dryers, fireplaces, incinerators, automobiles, and other internal combustion engines. Even if there are no laws in your jurisdiction requiring a CO Alarm, it’s highly recommended that whenever any fuel burning product is used in or around the home or business that the dwelling be equipped with a CO Alarm(s). The Consumer Product Safety Commission recommends the use of CO Alarm(s). The CO Alarm(s) must be installed, operated, and maintained according to the CO Alarm manufacturer’s instructions. For more information about Carbon Monoxide, local laws, or to purchase a CO Alarm online, please visit the following website. https://www.kidde.com
WARNING
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury, death, or
property damage.
Do not use this furnace if any part has been under water. A flood-damaged
furnace is extremely dangerous. Attempts to use the furnace can result in fire
or explosion. A qualified service agency should be contacted to inspect the
furnace and to replace all gas controls, control system parts, and electrical
parts that have been wet, or the entire furnace if deemed necessary.
WELCOME TO TODAY’S GENERATION OF COMFORT
Congratulations! In light of rising energy costs, a 90+% AFUE Condensing Gas
Furnace from Bryant Heating & Cooling Systems is among the soundest
investments today’s homeowner can make.
Your new furnace is truly a triumph of technology in home heating. A
revolutionary design employs two heat exchangers to “squeeze” out the maximum
amount of heat from the fuel consumed. In fact, your new furnace is so
efficient, over 90%¹ of the heat generated during combustion is captured and
delivered inside your home.
This furnace is among the safest, most dependable, energy-efficient furnaces
you can buy today. We are proud of the technological advances incorporated
into the design of this furnace. With only minimal care, your new furnace will
deliver many years of money-saving home comfort and enjoyment. Spend just a
few minutes with this manual to learn the operation of your new furnace and
the small amount of maintenance it takes to help keep it operating at peak
efficiency year after year.
- The output capacity and any representations of efficiency for this furnace are based on standard U.S. Department of Energy test procedures.
WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in dangerous operation,
serious injury, death, or property damage.
Improper servicing could result in dangerous operation, serious injury, death
or property damage.
– Before servicing, disconnect all electrical power to furnace.
– When servicing controls, label all wires prior to disconnecting.
Reconnect wires correctly.
– Verify proper operation after servicing.
FURNACE COMPONENTS
(Furnace shown in upflow position; may be used in downflow or horizontal orientation or applications.)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
Fig. 1 – Furnace Components
A170154
-
GAS VALVE
-
MANUAL RESET ROLLOUT SWITCH
-
FLAME SENSOR
-
GAS BURNER
-
HOT SURFACE IGNITER
-
MANUAL RESET ROLLOUT SWITCH
-
MAIN LIMIT SWITCH
(BEHIND GAS VALVE) -
INDUCER MOTOR ASSEMBLY
-
MEDIA CABINET
-
BLOWER AND MOTOR
-
CAPACITOR/ POWER CHOKE (IF USED)
-
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR) -
FURNACE CONTROL BOARD
-
BLOWER DOOR SAFETY SWITCH
-
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)
-
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
SAFETY CONSIDERATIONS
Installing and servicing of heating equipment can be hazardous due to gas and
electrical components. Only trained and qualified personnel should install,
repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions such as cleaning
and replacing air filters. All other operations must be performed by trained
service personnel. Observe safety precautions in this manual, on tags, and on
labels attached to the furnace and other safety precautions that may apply.
Recognize safety information. This is the safety-alert symbol . When you see
this symbol on the furnace and in instructions or manuals, be alert to the
potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION, and NOTE. DANGER,
WARNING, and CAUTION are used with the safety-alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which may result in minor
personal injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
To minimize the possibility of serious personal injury, fire, damage to your
furnace, or improper operation, carefully follow these safety rules which
apply to both direct-vent and non-direct vent applications:
- Your new gas furnace may have been installed in one of two ways, as a direct-vent (2-pipe-Fig. 2) application or as a non-direct vent (1-pipe-Fig. 3) application.
- In a direct-vent (2-pipe) application, your furnace uses air from outside the home for combustion and vents flue gas to the outdoors. This type of application will have two pipes running from the furnace to the outdoors. In some cases, the inlet air pipe may be located in an area that has access to outdoor air, such as an attic. In all cases, the outlet vent pipe must be routed to the outdoors (see Fig. 2). In this application, the vent and air-intake pipes must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings on furnace or spaces around furnace.
- In a non-direct vent (1-pipe) application, your furnace uses air from adjacent to the furnace for combustion and vents flue gas to the outdoors. This type of application will have only one pipe running from the furnace to the outdoors (see Fig. 3). The other pipe will terminate in the same space as the furnace and is the source of combustion air for your furnace. Therefore, the furnace must not be enclosed in an airtight room or be sealed behind solid doors. It must have adequate airflow for efficient combustion and safe ventilation. Do not obstruct the combustion-air pipe in any way. The vent pipe must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings or space around furnace.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in personal injury, death, or property
damage.
Keep insulation clear of furnace and maintain clearances shown on unit
clearance label.
Do not keep combustible materials, gasoline, and other flammable liquids or
vapors around your furnace.
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow instructions could result in severe personal injury or death
due to carbon monoxide poisoning, if combustion products infiltrate into the
building.
Check that all openings in the outside wall around the vent (and air intake)
pipe(s) are sealed to prevent infiltration of combustion products into the
building.
Check that furnace vent (and air intake) terminal(s) are not obstructed in any
way during all seasons.
A11258
Fig. 2 – Exterior Vent Pipes
A11259
Fig. 3 – Interior Combustion – Air Pipe
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, or
property damage.
Do not keep combustible materials, gasoline, and other flammable liquids or
vapors around your furnace.
- Keep the area around your furnace clear and free of combustible materials, gasoline, and other flammable liquids and vapors.
A92182
Fig. 4 – NO combustible materials near furnace
- Do not cover the furnace, store trash or debris near it, or in any way block the flow of fresh air to the unit.
CAUTION
UNIT OPERATION HAZARD
Failure to follow this caution may result in intermittent unit operation.
For proper and safe operation the furnace needs air for combustion and
ventilation. Do not block or obstruct air openings on the furnace, air opening
to the area in which the furnace is installed, and the space around the
furnace
In addition to the safety rules above, make sure that the following In addition to the safety rules above, make sure that the following combustion- air requirements are met for non-direct vent applications:
- Combustion air must be clean and uncontaminated with chlorine or fluorine. These compounds are present in many products around the home, such as: water softener salts, laundry bleaches, detergents, adhesives, paints, varnishes, paint strippers, waxes, and plastics.
- Make sure the combustion air for your furnace does not contain any of these compounds. During remodeling be sure the combustion air is fresh and uncontaminated. If these compounds are burned in your furnace, the heat exchangers may deteriorate.
- A furnace installed in an attic or other insulated space must be kept free and clear of insulating material. Examine the furnace area when the furnace is installed or when insulation is added. Some insulation materials may be combustible.
- Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off electrical supply.
This furnace contains SAFETY DEVICES which must be MANUALLY RESET. If the furnace is left unattended for an extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See “Before You Request a Service Call” section in this manual.
BEFORE STARTING YOUR FURNACE
Examine the furnace installation to determine that:
- All flue gas carrying areas external to the furnace (i.e. chimney, vent connector) are clear and free of obstructions.
- The vent connector is in place, slopes upward and is physically sound without holes or gaps.
- The return-air duct connection(s) is physically sound, is sealed to the furnace casing, and terminates outside the space containing the furnace.
- The physical support of the furnace is sound without sagging cracks, gaps, etc. around the base.
- There are no obvious signs of deterioration of the furnace.
- The burner flames are in good adjustment (see Fig. 5) (by comparison with pictorial sketches or drawings of the main burner flame).
A11461
Fig. 5 – Burner Flame Adjustment
- Burner Flame
- Burner
- Manifold
STARTING YOUR FURNACE
WARNING
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Should the gas supply fail to shut off or if overheating occurs, turn off the
manual gas valve to the furnace BEFORE turning off the electrical supply and
install lockout tag.
Instead of a continuously burning pilot flame which wastes valuable energy, your furnace uses an automatic, hot surface ignition system to light the burners each time the thermostat signals the furnace to start.
Follow these important safeguards:
- Never attempt to manually light the burners with a match or other source of flame.
A92319
Fig. 6 – Do Not Light Burner with Match
-
Read and follow the operating instructions on inside of main furnace door, especially the item that reads as follows:
“Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on furnace label. If you don’t smell gas, go to the next step.” -
If a suspected malfunction occurs with your gas control system, such as the burners do not light when they should, refer to the shutdown procedures on inside of main furnace door, or in the “Shutting Down Your Furnace” section and call your dealer as soon as possible.
-
CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace filter is clean and in place. See “Performing Routine Maintenance” section in this manual. Do not run the furnace without a filter in place. Then proceed as follows:
STEPS FOR STARTING YOUR FURNACE
1. Set your room thermostat to the lowest temperature setting and set the “MODE” to “OFF” (see Fig. 7).
A09564
Fig. 7 – Lowest Temperature Setting
2. Close the external manual gas valve (see Fig. 8).
A06188
Fig. 8 – Close Valve
3. Turn OFF electrical supply to the furnace (see Fig. 9).
A92185
Fig. 9 – Turn Off Electrical Supply
4. Remove the main furnace door (see Fig. 10).
A11260
Fig. 10 – Remove Main Furnace Door (Upflow Configuration)
5. Turn the control switch on the gas control to the OFF position and wait five minutes (see Fig. 11). Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on furnace label. If you don’t smell gas, go to next step.
SINGLE-STAGE GAS CONTROL TWO-STAGE GAS CONTROL
MODULATING GAS CONTROL
A11292
Fig. 11 – Control Switch to OFF
- GAS CONTROL SWITCH SHOWN IN “OFF” POSITION
6. After waiting five minutes, turn control switch on the gas control to the ON position. Turn the control switch to ON (see Fig. 12).
SINGLE-STAGE GAS CONTROL TWO-STAGE GAS CONTROL
MODULATING GAS CONTROL
A11291
Fig. 12 – Control Switch to ON
- GAS CONTROL SWITCH SHOWN IN “ON” POSITION
7. Replace main furnace door (see Fig. 13).
A11261
Fig. 13 – Furnace Door Replaced (Upflow Configuration)
8. Turn ON the electrical supply to the furnace and wait one minute (see Fig. 14).
A92359
Fig. 14 – Turn on Electrical Supply
9. Open the external manual gas valve (see Fig. 15).
A06189
Fig. 15 – Open Valve
10. Set the room thermostat “MODE” to “HEAT” and adjust the set point to a
temperature slightly above the room temperature. This will automatically
signal the furnace to start.
11. When the furnace receives the start signal, the combustion air draft
inducer is started. When the pressure switch senses that there is sufficient
combustion air, the hot surface igniter is energized.
After the hot surface igniter is heated for about 20 seconds, the gas valve
permits gas to flow to the main burners. After ignition and a time delay of up
to 60 seconds, the furnace blower will start.
Variable-capacity furnaces start at low speed until the control makes the
necessary adjustments to operate the blower at either the low- or high-heat
speed.
NOTE: If the main burners fail to ignite after four attempts, the furnace control system will lock out. If lockout occurs, main burners fail to light, or blower does not come on, shut down the furnace and call your dealer for service.
12. Set your thermostat to the temperature that satisfies your comfort requirements.
SUGGESTION: Setting the thermostat back a few degrees—and compensating
for the difference with warmer clothing—can make a big difference in your fuel
consumption on extremely cold days. The few degrees at the top of your
thermostat “comfort level” are the most costly degrees to obtain.
When the room temperature drops below the temperature selected on the
thermostat, the furnace will switch on automatically. When the room
temperature reaches the setting selected on the thermostat, the furnace will
be automatically switched off.
Continuous Fan Operation – Some thermostats have a “FAN” switch with two
selections: AUTO and ON. When the thermostat is set on AUTO, the furnace
blower cycles on and off, controlled by the thermostat. In ON position, the
furnace blower runs continuously.
Continuous fan keeps the temperature level in your home more evenly balanced.
It also continuously filters the indoor air.
On all but the base series furnace, the blower speed can be increased or
decreased if desired due to change of seasons, large gatherings in your home,
etc. Simply change your FAN from ON to OFF for 1 to 3 seconds (or AUTO
depending on your thermostat), and then return to ON. The blower will switch
to the next higher speed. There are at least three speeds to choose from. If
the blower is running on its highest speed, a request to change will direct
the blower to return to its lowest speed.
SHUTTING DOWN YOUR FURNACE
Should you need to shut down your furnace for service or maintenance, you will need to turn the furnace off. The following procedures must be followed:
1. Set your room thermostat to the lowest temperature setting and set the “MODE” to “OFF” (see Fig. 16).
A09564
Fig. 16 – Lowest Temperature Setting
2. Close the external manual gas valve (see Fig. 17).
A06188
Fig. 17 – Close the External Manual Valve
3. Turn off electrical supply to the furnace (see Fig. 18).
A92185
Fig. 18 – Turn Off Electrical Supply
4. Remove main furnace door (see Fig. 10).
5. Turn control switch on the gas control to “OFF” position (see Fig. 11).
6. Replace main furnace door (see Fig. 13).
7. If the furnace is being shut down because of a malfunction, call your
dealer as soon as possible.
CAUTION
UNIT AND PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in unit component or property
damage.
Furnace is not to be installed, operated, and then turned off and left turned
off in an unoccupied structure during winter. See “Winterization” procedures
in this manual.
MINIMUM & MAXIMUM TEMPERATURE SETTING FOR YOUR FURNACE
This furnace is designed for minimum continuous return-air temperature of 60°F (16°C) or intermittent operation down to 55°F (13°C) such as when used with a night setback thermostat. Return-air temperature must not exceed 80°F (27°C). Failure to follow these return-air temperature limits may affect reliability of heat exchangers, motors, and controls.
PERFORMANCE ROUTINE MAINTNENANCE
NOTE: The qualified installer or agency must use only factory-authorized
replacement parts, kits, and accessories when modifying this product.
Installing and servicing of heating equipment can be hazardous due to gas and
electrical components.
Only trained and qualified personnel should install, repair, or service
heating equipment. Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters.
All other operations must be performed by trained service personnel. Observe
safety precautions in this manual, on tags, and on labels attached to the
furnace and other safety precautions that may apply.
With proper maintenance and care, your furnace will operate economically and
dependably. Instructions for basic maintenance are found on this and the
following pages. However, before beginning maintenance, follow these safety
precautions:
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace and install lockout tag
before removing the access doors to service or perform maintenance.
WARNING
CUT HAZARD
Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp edges, be extremely
careful when handling parts or reaching into the furnace.
Wear safety glasses, gloves, and appropriate protective clothing.
FILTERING OUT TROUBLE
NOTE: The manufacturer has specified filters which will enable your furnace to provide lasting comfort and efficiency throughout its life. Contact your dealer to help you choose filters for your furnace that both collect dirt before it enters your furnace, as well as provide a low resistance to circulating air. Avoid filters that report high cleaning efficiencies, but do not allow air to pass easily through them.
CAUTION
UNIT PERFORMANCE HAZARD
Failure to follow this caution may result in unit component damage.
Never operate your furnace without a filter in place. Doing so may damage the
furnace blower motor. An accumulation of dust and lint on internal parts of
your furnace can cause a loss of efficiency.
CAUTION
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Use care when cutting support rods in filters to protect against flying pieces
and sharp rod ends. Wear safety glasses, gloves, and appropriate protective
clothing.
A dirty filter will cause excessive stress on the furnace, heat exchanger, and
blower motor, and can cause it to overheat and automatically shut down. The
furnace filter should be checked every four weeks and be cleaned or replaced
if necessary.
If installed with factory-specified disposable media filter, check or replace
filter before each heating and cooling season. Replace disposable media filter
at least once a year.
If your furnace filter needs replacing, be sure to use the same size and type
of filter that was originally specified.
The air filter for the furnace may be located an external filter cabinet
attached to the side or bottom of the furnace casing. If the air filter has
been installed in another location, contact your dealer for instructions.
To inspect, clean and/or replace the air filter(s), follow these steps:
1. Turn off electrical supply to the furnace (see Fig. 19).
2. Remove air filter from the filter cabinet.
a. Remove filter cabinet door (see Fig. 20 and Fig. 21).
NOTE: It maybe necessary to remove one thumbscrew.
b. Slide air filter out of furnace. Keep dirty side up (if dirty) to avoid spilling dirt (see Fig. 22 and Fig. 23).
3. Inspect the filter. If torn replace it.
NOTE: If a washable filter was supplied with the furnace and has been replaced by:
- Disposable media filter-Do not clean. If dirty, replace only with media filter having the same part number and size. Install with airflow direction arrow pointing towards blower.
- Electronic Air Cleaner (EAC), refer to the EAC Owner’s Manual for maintenance information.
4. If washable filter, wash filter (if dirty) in a sink, bathtub, or outside
with a garden hose. Always use cold tap water. A mild liquid detergent may be
used if necessary. Spray water through filter in the opposite direction of
airflow. Allow filter to dry.
5. Reinstall clean air filter.
6. Turn on electrical supply to the furnace.
If your furnace air filter needs to be replaced, be sure to use a factory- authorized filter of the same size that was originally specified. Use the filter tables and compare your furnace size with the proper filter size.
A92185
Fig. 19 – Turn Off Electrical Supply
A00225
Fig. 20 – Removal of Filter Cabinet Door from Side Blower Cabinet
A00226
Fig. 21 – Removal of Filter Cabinet Door from Bottom Blower Cabinet
A00227
Fig. 22 – Removal of Filter from Side Blower Cabinet
A00228
Fig. 23 – Removal of Filter from Bottom Blower Cabinet
A00229
Fig. 24 – Replacement of Filter Cabinet Door to Side Blower Cabinet
A00230
Fig. 25 – Replacement of Filter Cabinet Door to Bottom Blower Cabinet
Table 1 – Air Filter Located in Filter Cabinet
FILTER CABINET HEIGHT – IN (MM)
| FILTER SIZE – IN (MM)| FILTER TYPE
---|---|---
16 (406)| (1) 16 x 25 x 3/4
(406 x 635 x 19)
or
(1) 16 x 25 x 4-5/16
(406 x 635 x 110)| Washable†
20 (508)| (1) 20 x 25 x 3/4
(508 x 635 x 19)
or
(1) 20 x 25 x 4-5/16
(508 x 635 x 110)| Washable†
24 (610)| (1) 24 x 25 x 3/4*
(610 x 635 x 19)
or
(1) 24 x 25 x 4-5/16
(610 x 635 x 110)| Washable†
*. Filters with a side return-air may have a different filter size. Measure the filter to obtain the correct size.
†. Recommended to maintain air filter face velocity. See Product Data for part
number.
COMBUSTION AIR AND VENT SYSTEM
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
If holes are found or if the vent pipe is obstructed or is not connected,
toxic fumes can escape into your home. DO NOT OPERATE YOUR FURNACE. Call your
dealer for service.
CAUTION
UNIT OPERATION HAZARD
Failure to follow this caution may result in intermittent unit operation.
For proper and safe operation the furnace needs air for combustion and
ventilation. Do not block or obstruct air openings on the furnace, air opening
to the area in which the furnace is installed, and the space around the
furnace.
Visually inspect the combustion area and vent system before each heating
season. Make sure that all PVC pipes leading into the combustion area and vent
are free from any cracks and sags. An accumulation of dirt, soot, or rust can
mean a loss of efficiency and improper performance. Buildups on the main
burners can cause faulty firing. This “delayed ignition” is characterized by
an alarmingly loud sound.
Check the combustion-air intake adjacent to the furnace or outside your home
for blockage. Also check the vent pipe on the outside of your home for
blockage.
NOTE: If your furnace makes a loud noise when the main burners are
ignited, shut down the furnace and call your servicing dealer.
Use your flashlight and follow these steps for inspecting the combustion area
and vent system of your furnace:
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
If dirt, rust, soot, or scale accumulations are found, call your dealer. Do
not operate your furnace.
1. Turn off electrical supply and gas supply to the furnace and remove the main furnace door (see Fig. 7, Fig. 8, Fig. 9, Fig. 10 and Fig. 11).
CAUTION
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace and install lockout tag
before removing the access doors to service or perform maintenance.
2. Inspect the gas burners, igniter area, and remainder of furnace for dirt, rust, soot or scale.
A11319
Fig. 26 – Gas Burner Assembly (Upflow)
-
HOT SURFACE IGNITOR
-
MANUAL RESET LIMIT SWITCH
-
MAIN LIMIT SWITCH
(BEHIND GAS VALVE) -
GAS VALVE
-
MANUAL RESET LIMIT SWITCH
-
FLAME SENSOR
-
GAS BURNER ASSEMBLY
A11320
Fig. 27 – Gas Burner Assembly (Downflow)
- GAS VALVE
- MANUAL RESET LIMIT SWITCH
- FLAME SENSOR
- GAS BURNER ASSEMBLY
- HOT SURFACE IGNITOR
- MANUAL RESET LIMIT SWITCH
- MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
3. Inspect the combustion-air and vent PVC pipes for sags, holes, cracks,
water leaks, blockage or disconnections. Horizontal portions of vent pipe must
slope downward toward the furnace.
4. If your furnace is free of the above conditions, turn on electrical and
gas supplies to the furnace.
5. Start your furnace and observe its operation. Watch the burner flames to
see if they are clear blue, almost transparent (see Fig. 28).
If you observe a suspected malfunction, or the burner flames are not clear
blue, call your dealer.
6. Replace main furnace door.
A11461
Fig. 28 – Burner Flame Adjustment
- Burner Flame
- Burner
- Manifold
WINTERIZATION
CAUTION
UNIT AND PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in unit component or property
damage.
If the furnace is installed in an unconditioned space where the ambient
temperatures may be 32° F (0° C) or lower, freeze protection measures must be
taken to prevent minor property or product damage.
Since the furnace uses a condensing heat exchanger, some water will accumulate in the unit as a result of the heat transfer process. Therefore, once it has been operated, it cannot be turned off and left off for an extended period of time when temperatures will reach 32°F (0°C) or lower unless winterized. Follow these procedures to winterize your furnace:
CAUTION
UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in damage to the furnace and other
property damage.
Do not use ethylene glycol (Automotive antifreeze coolant or equivalent).
Failure of plastic components may occur.
1. Obtain propylene glycol (RV/swimming pool antifreeze or equivalent).
2. Turn off gas and electrical supplies to your furnace.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace and install lockout tag
before removing the access doors to service or perform maintenance.
3. Remove furnace control compartment door.
4. Remove one of the unused rubber plugs in the port on the collector box
opposite the condensate trap. See Fig 30
5. Connect a field supplied 3/8-in. (9.5-mm) ID tube to the open port on the
collector box
6. Insert a field supplied funnel into the tube.
7. Pour 1 quart of anti-freeze solution into the funnel/tube. Antifreeze
should run through the inducer housing, overfill condensate trap and flow to
an open drain.
8. If a condensate pump is used, check with pump manufacturer to verify pump
is safe for use with antifreeze used. Allow pump to start and pump anti-freeze
to open drain.
9. Remove funnel and tube from collector box.
10. Replace plug in collector box.
11. Remove the other plug and repeat steps 4-10.
12. Replace main door.
13. When furnace is re-started, flush condensate pump with clear water to
check for proper operation before re-starting furnace.
14. Propylene glycol need not be removed before re-starting furnace.
A11392
Fig. 29 – Winterizing Furnace
A CHECK-UP CHECKLIST
Your furnace represents an important investment in your family’s comfort and your home’s value. To keep it performing properly and to prevent future problems, have a trained service specialist give your furnace a professional check-up annually. The following checklist can be used as a guideline to proper service:
- Inspect all flue gas passages, burners, heat exchangers, coupling box(es), and inducer assembly.
- Inspect all combustion-air and vent piping inside structure and pipe terminations outside the structure.
- Check gas pipes leading to and inside of your furnace for leaks.
- Inspect and clean the blower motor and wheel.
NOTE: The inducer and blower motors are pre-lubricated and require no additional lubrication. These motors can be identified by the absence of oil ports on each end of the motor.
- Inspect and change or clean air filter(s) if necessary.
- Inspect all supply- and return-air ducts for obstructions, air leaks, and insulation. Remedy any problem when necessary.
- Inspect the return-air duct connection(s) at the furnace to ensure it is physically sound, sealed to the furnace casing, and terminates outside the space containing the furnace.
- Inspect electrical wiring, connections, and components for loose connections.
- Perform an operational checkout to determine whether your furnace is working properly and if it requires adjustments.
- Inspect all condensate drain tubes and condensate trap assembly for leaks. The condensate removal system should be cleaned annually by a qualified service agency. Refer to the Service and Maintenance Instructions Guide for further information.
- Examine the physical support of the furnace. Support should be sound with no cracks, sagging, gaps, etc. around the base.
- Check furnace for any obvious signs of deterioration.
- Ask your servicing dealer for further details about an economical service contract that covers seasonal inspections.
A11318
Fig. 30 – Information Booklet Location
BEFORE YOU REQUEST A “SERVICE CALL”
If your furnace is not operating or not performing properly, you may save the expense of a service call by checking a few things yourself before calling for service.
NOTE: Record the LED status code BEFORE removing the blower access door or turning off 115-v power to the furnace. See the information booklet inside the main furnace door for a service code legend (see Fig. 30).
For insufficient airflow:
- Check for dirty air filter(s).
- Check for blocked return-air or supply-air grilles. Be sure they are open and unobstructed.
If problem still exists, call your dealer for service.
If furnace fails to operate:
Follow this checklist step by step, advancing to the next stop only if furnace fails to start.
- Check thermostat for proper temperature. Is thermostat set above room temperature?
- Is thermostat set to HEAT mode?
- Check fuses and circuit breakers. Is the electrical power supply switch on?
- Is the manual shut-off valve in the gas supply pipe leading to the furnace open?
NOTE: Turn off electrical supply before continuing with checklist.
- Is control switch on gas valve in ON position? (Follow start-up procedures if you must reset switch to ON position.)
- Check manual reset rollout switch located on the burner box. See Furnace Components in Fig. 1. If furnace has experienced high temperature conditions, this switch will shut off the furnace. Reset it by pushing the button on the switch. If it trips again, shut down the furnace and call for service. See “Shutting Down Your Furnace” section in this manual.
- Check for obstructions around the vent termination.
If your furnace still fails to operate, call your service representative.
For your convenience, record the furnace product and serial numbers on back
page. Should you ever require service, you will have ready access to the
information needed by your service representative.
This furnace has a light emitting diode (LED) status code display to aid the
installer, service technician, or homeowner while installing or servicing the
unit. The LED code can be seen through the view port in the blower access
panel.
NOTE TO EQUIPMENT OWNER:
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information will be helpful should your system require maintenance or service.
FURNACE
Model # _____
Serial # __
AIR CONDITIONER OR HEAT PUMP
Model #
Serial #
INDOOR COIL (Furnace Coil or Fan Coil)
Model #
Serial #
INSTALLATION INFORMATION:
Date Installed ____
DEALERSHIP CONTACT INFORMATION:
Company Name___
Address__
Phone Number __
Technician Name
NOTE TO INSTALLER:
This manual must be left with the equipment owner.
A200102
MAINTENANCE CHECKLIST
In addition to the type of routine maintenance you might be willing to
perform; your furnace should be inspected regularly by a properly trained
service technician.
You should work with your dealer or service technician to assure your
inspection includes the following at a minimum.
This list may not include all maintenance items, and inspection interval times
may vary depending on operational conditions of the furnace.
DESCRIPTION
| INSPECTION INTERVAL
---|---
Monthly| Semi-Annually|
Annually
Furnace specific, external items:| | |
| | |
Clean or replace air filters.
|
X
| |
Inspect cabinet for signs of damage.
|
X
| |
Inspect electrical disconnect for proper function. Repair or replace as necessary.
| |
X
|
Inspect external wiring for damage.
| |
X
|
Inspect gas supply line and manual shut-off for leaks.
| | |
X
Furnace specific, internal items:| | |
| | |
Inspect and clean blower assembly (includes blower housing, blower wheel and motor).
| |
X
|
Inspect gas valve and check for proper manifold gas pressure Adjust as needed.
| | |
X
Inspect ignition system and safety controls. Clean and adjust as needed.
| | |
X
Inspect control box, associated controls, wiring and connections.
| | |
X
Check combustion blower housing for lint and debris and clean as necessary.
| | |
X
Inspect burner assembly – clean as needed.
| | |
X
Inspect RPJ? heat exchanger – clean as needed.
| | |
X
Inspect flue system—check for proper attachment to the furnace, any dislocated sections, and for signs of corrosion. Replace if necessary.
| | |
X
System:| | |
| | |
Inspect airflow system (ductwork)—check for leaks and repair as needed.
| |
X
|
Inspect evaporator coil, drain pan and condensate drain lines as applicable. Clean as needed.
| |
X
|
Ask your servicing dealer for further details about an economical service contract that covers seasonal inspections.
©2020 Carrier Edition Date: 04/20 Catalog No:OM9GFRB-02
A Carrier Company Replaces:OM9GFRB-01
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Documents / Resources
|
bryant 986TC Condensing Gas
Furnace
[pdf] Owner's Manual
986TC Condensing Gas Furnace, 986TC, Condensing Gas Furnace, Gas Furnace,
Furnace
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>