Acu-Trol AKC02 Chemical Controller For Bodies Of Water Installation Guide

October 31, 2023
Acu-Trol

Acu-Trol-logo

Acu-Trol AKC02 Chemical Controller For Bodies Of Water

Acu-Trol AKC02 Chemical Controller For Bodies Of Water-
product

Product Information

The AKC02 and AK-Auto C02 Injection Systems are designed for installation in pools and spas. These systems help regulate the pH levels of the water by injecting CO2 into the water. This helps maintain a safe and comfortable swimming environment.

Chapter 1
Chapter 1 of the user manual provides important information regarding safety precautions, warranty, AKCO2 overview, and introduction to the product.

Chapter 2
Chapter 2 of the user manual provides detailed instructions on how to prepare for installation, electrical installation requirements, mounting the AKCO2 system, and finishing and testing the installation.

INFORMATION

SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY.

INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information.

IMPORTANT NOTICE
Attention Installer: This Installation and Operation Guide (“Guide”) contains important information about the installation, operation and safe use of this product. This Guide should be given to the owner and/or operator of this product.

Before installing this product, read and follow all warning notices and instructions in this Guide. Failure to follow warnings and instructions can result in severe injury, death, or property damage.

Call (800) 831-7133 for additional free copies of these instructions. Please refer to www.pentairpool.com for more information related to this products.

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
BEFORE WORKING ON THIS PRODUCT
Always disconnect power to the unit at the circuit breaker before servicing.
Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock.

BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING.

AKCO2 HIGH, LOW and N R are Class 1 products for protection against electric shock and a Type 1 products with regards to disconnection of the control circuits. This product must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.2. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property.

Do not permit children to operate this equipment.
Risk of electrical shock. Connect this product to a ground-fault interrupter- circuit (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

Be sure to observe the following safety precautions:

  • Unit must be properly connected to earth ground.
  • Never apply power unless unit is properly mounted with no internal parts exposed.
  • Never service unit with power applied, always turn OFF main circuit breaker to unit and all equipment when servicing.
  • Touching the controller’s internal parts could result in injury and or damage to the controller. In case of a malfunction, only a qualified technician should repair the unit.
  • Risk of Electric Shock. Connect only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician if verification on the receptacle is not protected by GFCI.
  • Do not bury cord. Route cord to eliminate abuse from heater exhaust, lawn mowers, hedge trimmers, and other equipment.
  • Be careful not to damage any of the insulation on wires or the power cord. Should the cord be damaged, return it to your dealer for a replacement. Continued use could result in fire or electric shock.
  • To reduce the risk of electric shock, do not use an extension cord to connect unit to electric supply; provide a properly located GFCI.
  • Take necessary precautions while working with high pressure gas.

WARRANTY

cPentair Water Commercial Pool and Aquatics™ (”Pentair”) w arrants the AKCO2 to be free from defects in manufacturing and workmanship for a period of One (1) YEAR from the date of manufacture for the electronic module. All external parts have a warranty of one (1) year. Other equipment is covered by manufacturer’s own warranty. During the warranty period, any defective parts will be repaired or replaced when necessary b y Pentair.

This warranty does not cover: (a) the buyers’ labor or any servicing fees related to replacement of the Product; (b) damage resulting from the use of this Product in other t han its normal manner; (c) damage from misuse, accident or neglect; (d) damage from improper testing,

operation, or installation; (e) not operating the Product on a dedicated (separate) circuit or under conditions other than those recommended or at voltages or amperages other than the voltage or amperage indicated on the Product; and (f) acts of Mother Nature (i.e. lightning, electrical storms, floods, etc.). In addition, attempting to service or modify the Product will render this Warranty Void. Defective parts should be returned immediately to the local Pentair dealer, any parts returned to the factory require a return of material authorization code to subsequently generate an RMA (Return to Manufacturer form). A Pentair Technician will analyze the returned part and determine the cause of failure and process accordingly.

AKCO2 OVERVIEW

SUMMARY: The AKCO2 systems provide injection and absorption of CO2 gas into a circulating water system, via solenoid with rate control valve. CO2 is a natural, non-corrosive gas that can be used as a substitute for liquid acid in chemical treatment of aquatic systems. When dissolved in water it forms weak acid, H2CO3 (carbonic acid), which can be used to lower pH and raise total alkalinity.

AKCO2 features as follows:

SOLENOID AND RATE CONTROL VALVE: U.L. Listed solenoid, bronze body with ¼” connections are controlled via 120VAC coil relay housed in a vented anodized aluminum case. Rate control valve has full range adjustment and indicator. Capacity is 30 SCFH for AKCO2 LOW and 100 SCFH for AKCO2 HIGH.

REGULATOR: AKCO2 LOW uses a U.L. Listed 50 PSI fixed output regulator with a 0 – 4000PSI tank pressure gauge. AKCO2 HIGH uses a U.L. Listed 50 PSI fixed output heated regulator with a 0 – 4000PSI tank pressure gauge. AKCO2 NR has NO REGULATOR.

CO2 INJECTOR ASSEMBLY: has a built-in check valve with ½ NPT threaded high-density porous polyethylene diffuser.

PLUMBING: All fittings are 3/8 Polypropylene Tube fittings, and the tubing is Low Density Polyethylene with a 120 PSI at 73 degrees F rating.

AKCO2 LOW

AK-AUTO

INTRODUCTION

The AKCO2 INSTALLATION AND OPERATION MANUAL explains the procedures for proper installation and operation of the AKCO2 series CO2 injection systems.
The INSTALLATION portion, introduces the parts of the AKCO2 and the process to follow when installing the electrical connections for the AKCO2.

The OPERATION portion, describes how to use the AKCO2.

If you have any questions regarding this product, please feel free to call your local dealer or Pentair Water Commercial Pool and Aquatics™ (“Pentair”) directly.

  • Receipt Inspection: Upon receiving an AKCO2 system, check the carton carefully. Report any damaged items directly to the shipping company. Go through the shipping list and verify that all items are present. Please contact your local dealer if any inventoried items are missing or have been damaged. Use care when unpacking equipment to avoid damage or loss of small parts.

Input Power: 120VAC.
Select INPUT devices: The AKCO2 systems are designed to be used with Pentair controllers.

PLUMBING/ELECTRICAL INSTALLATION

Each electrical installation for the AKCO2 can be different. This manual gives the basic principles to be applied for any specific installation as follows

  • Identify the new and existing equipment to be connected.
  • Determine the controller supplying on power.
  • Determine the placement of the controller and mount. (See mounting below)
  • Determine the AKCO2’s mounting location, and mount.
  • Locate CO2 cylinder within six feet of controller.
  • Use plumbing tape on all plumbing fittings and diffuser installation.
  • Install the diffuser in the return line by drilling and tapping a ½ “ NPT hole in the bottom of the line. CAUTION! The diffuser needs to be installed downstream of any equipment since the CO2 produces a pH of around 5.5. Thread the diffuser up into the ½” NPT hole.
  • Use only 3/8” O.D. Polyethylene pipe from the AKCO2 to the diffuser.
  • Connect the pressure regulator to the cylinder. The regulator has a fixed 50PSI output.
  • Use only 3/8” O.D. Polyethylene pipe from the AKCO2 to the regulator.
  • Connect the control from a normally open relay set for 120VAC operation using 18GA pigtail. Or hardwire with Relay NO line voltage must be connected to the AKCO2 “BLACK” wire, relay NO neutral must be connected to the AKCO2 “WHITE” wire, and Relay GND (Ground) must be connected to the AKCO2 “GREEN” wire.
  • On AKCO2 HIGH connect the regulator heater to 120VAC power.
  • Connect the supply voltage.
  • Test the operation of the AKCO2.

WARNING! Be sure to have a licensed electrician perform all electrical wiring. This is important, as they will be familiar with the electrical codes in the local area.

ELECTRICAL AND CO2 SPECIFICATIONS

The following electrical specifications in the table below must not be exceeded.

ITEM

| DESCRIPTION|

LIMIT

---|---|---
Control| Power control form controller| 120VAC
AKCO2 HIGH| To Regulator Heater| 120VAC
CO2 Pressure| Before regulator (Bottle Pressure)| 3000 PSI max
CO2 Pressure| After regulator| 50 PSI max
CO2 Flow| AKCO2 LOW and NR flow| 0 – 30 SCFH
CO2 Flow| AKCO2 HIGH flow| 0 – 100 SCFH

MOUNTING THE AKCO2

Select a location for mounting th e AKCO2 , meeting the following recommendations:

  • At least ten (10) feet from open water.
  • Supply power must be routed to the AKCO2 in accordance with the applicable codes in the area; the supplied cord is not code in some areas.
  • Mount with four bolts.
  • The environment should be free of chemical fumes and excessive heat. The maximum room temperature is 110 ºF.
  • Mount as far as possible from sources of electrical interference.
  • Since the AKCO2 produces a very low pH the Discharge should be plumbed after all other equipment just before the return to the pool. The Suction should be plumbed after the main filter.

FINISHING AND TESTING

Once the AKCO2 system has been installed the following steps are required for final system finishing and testing.

  1. Perform STARTUP procedure.
  2. Test system for leaks.
  3. Record the feed rate calculated in the STARTUP nearby unit for future use.
  4. Test and operate.

CHAPTER 3 OPERATION

CONTROLS

Pressure: The AKCO2 has a fixed 50 PSI output regulator. If you use an adjustable regulator or facility supplied CO2, set the output pressure no greater than 50 PSI.

FLOW: The AKCO2 CO2 flow should be adjusted to as low as possible while still maintaining the desired pH control. A perfectly adjusted and balanced system will have CO2 feed times of less than 1 minute for systems consisting of 2000 gallons or less and feed times of 1 to 5 minutes for systems greater than 2000 gallons.

AKCO2 STARTUP

To startup an AKCO 2 follow to steps below.

  1. Start with the AKCO2 control relay in the OFF position, the CO2 cylinder valve closed, and the CO2 flow valve closed.
  2. Open the CO2 cylinder valve and test the CO2 lines for leaks with a soap solution.
  3. Manually turn on the control relay and slowly open the CO2 flow valve until the flow gage reads 5 SCFH for systems consisting of 2000 gallons or less and 20-25 SCFH for systems greater than 2000 gallons.
  4. Turn off the control relay. The CO2 flow should stop.
  5. Hand check the system water pH. Record value.
  6. Turn on the control relay. Note the time. For a LARGE body of water, greater than 2000 gallons, wait 5 minutes and then turn off the AKCO2 control relay. For a SMALL body of water, less than 2000 gallons, wait 1 minute and then turn off the AKCO2 control relay..
  7. Hand check the system pH. Record the value. See the work sheet below and calculate the feed rate.
  8. If the feed rate is too high redo steps 5 – 7 with the flow valve throttled to a lower flow. If the feed rate is too low redo step 5 – 7 with the flow valve throttled to a higher flow.
  9. Once feed rate is adjusted set the feed and mixing times in the relay program and place the relay in automatic. Startup is complete.

AKCO2 STARTUP WORK SHEET

  • STEP 5 Hand Check pH before CO2 flow valve opened _____ pH1
  • STEP 6 CO2 flow ___ CFPH
  • STEP 6 Time Start____ Time Stop ____ Total Time ____ Minutes
  • STEP 7 Hand Check pH after time test __ pH2
  • PH Change = pH1 – pH2 = ___ pH
  • Feed Rate = pH Change / Total Time ___ pH / minute

TROUBLE SHOOTING

PH IS NOT DECREASING

  1. Check that there is power to the unit and that the CO2 flow gage shows flow when unit is on.
  2.  If there is no CO2 flow check to see if the CO2 cylinder is empty and needs replacement.
  3.  If there is a great system load the current feed rate may not be able to keep up. The CO2 flow may need to be increased.

PH IS NOT CONTROLLING WELL

  1. Feed rate or controller programming is not balanced to water system needs. Perform the STARTUP again or adjust the controller relay feed and mixing times based on the feed rate calculated.

IMPORTANT : IF THERE REMAINS ANY PROBLEMS AFTER READING THE GUIDES & TROUBLESHOOTING PROCEDURES PLEASE CALL YOUR DEALER DIRECTLY. BEFORE CALLING PLEASE BE READY WITH THE FOLLOWING I

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals