Product Information: This product is a wall-mounted split system
air conditioner. It comes in various models: IFG09-AACT,
IFG12-AACT, IFG18-AACT, IFG24-AACT, IFX09-SCCT, IFX12-SCCT,
IFX18-SCCT, IFX24-SCCT. The air conditioner uses a flammable
refrigerant R32. Product Usage Instructions: 1. Temperature Range:
The air conditioner may stop running and experience anomalies if
the temperature is outside the range provided in the following
table for cooling and heating. Refer to the user manual for the
specific temperature range. 2. High Temperature: If the temperature
is too high, the air conditioner may activate the automatic
protection device and shut down. 3. Low Temperature: If the
temperature is too low, the heat exchanger of the air conditioner
may freeze, leading to water dripping or other malfunctions. 4.
Long-Term Cooling or Dehumidification: When using the air
conditioner for long-term cooling or dehumidification with a
relative humidity of above 80% (doors and windows are open), water
condensation or dripping near the air outlet may occur. 5. Climate
Class: The air conditioner belongs to Climate Class T1 according to
ISO 5151. 6. Notes for Heating: – The fan of the indoor unit will
not start running immediately after heating is started to avoid
blowing out cool air. – In cold and wet weather conditions, the
outdoor unit may develop frost over the heat exchanger, which
increases the heating capacity. The air conditioner will start the
defrost function automatically. – During defrost, the air
conditioner will stop heating for about 5-12 minutes. Vapor may
come out from the outdoor unit during defrost, which is not a
malfunction. – Heating will resume after defrost is complete. 7.
Notes for Turning Off: When turning off the air conditioner, the
main controller will automatically decide whether to stop
immediately or continue running for a few seconds with lower
frequency and lower air speed. Please refer to the user manual for
further instructions on installation, maintenance, troubleshooting,
and servicing.
IFG09-AACT IFG12-AACT IFG18-AACT IFG24-AACT IFX09-SCCT IFX12-SCCT IFX18-SCCT IFX24-SCCT
IFG09-AACT IFG12-AACT IFG18-AACT IFG24-AACT IFX09-SCCT IFX12-SCCT IFX18-SCCT IFX24-SCCT
9 0
For model
IFG09-AACT IFG12-AACT IFG18-AACT IFG24-AACT IFX09-SCCT IFX12-SCCT IFX18-SCCT
IFX24-SCCT
Notices for us
J—- The conditions of unit can’ t normally run
- Within the temperature range provided in following table, the air conditioner may
stop running and other anomalies may arise.
Co o l i n g Heating
Outdoor Indoor
Outdoor Indoor
49° C < 16° C < -15° C > 30° C
- When the temperature is too high, the air conditioner may activate the automatic
protection device, so that the air conditioner could be shut down. - When the temperature is too low, the heat exchanger of the air conditioner may freeze,
leading to water dripping or other malfunction. - In long-term cooling or dehumidification with a relative humidity of above 80% (doors
and windows are open), there may be water condenses or dripping near the air outlet. - Climate class is T1, and it refers to ISO 5151.
(
…
Notes for heating
- The fan of the indoor unit will not start running immediately after the heating is started to avoid blowing out cool air.
- When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will increased the heating capacity. Then the air conditioner will start defrost function.
- During defrost, the air conditioner will stop heating for about 5-12 minutes. Vapor may come out from the outdoor unit during defrost. This is not a malfunction,
but a result of fast defrost. Heating will resume after defrost is complete.
r
Notes for turning off
- When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.
-7 –
Navodila za uporabo
Zidna split sistem klimatska naprava Za model
IFG09-AACT IFG12-AACT IFG18-AACT IFG24-AACT IFX09-SCCT IFX12-SCCT IFX18-SCCT
IFX24-SCCT
Prosimo, da pred uporabo aparat pozorno preberete ta navodila! Shranite
navodila za poznejso uporabo.
VSEBINA
Uporaba in vzdrzevanje
Opozorilo
1
Varnostne informacije
2
Opombe za uporabo
7
Nazivi delov naprave
9
Ciscenje in vzdrzevanje
10
Odpravljanje tezav
12
Namestitev in servisiranje
Opombe glede namestitve
14
Namestitev notranje enote
18
Namestitev zunanje enote
21
Preverjanje in preizkus po namestitvi
24
Vzdrzevanje……………
25
Opomba: Vse slike v prirocniku so samo shematske, gre za standarno konfiguracijo.
Opozorilo
Opozorilo: Ta klimatska naprava uporablja vnetljivo hladilno sredstvo R 32.
Opombe: V kolikor se s klimatsko napravo s hladilnim sredstvom R32 neustrezno
rokuje, lahko pride do resnega ogrozenja ljudi in okolice. Prostor za
vgradnjo, uporabo, popravilo in skladiscenje te klimatske naprave mora biti
vecji od 5m! Klimtsko napravo se sme polniti z najvec 1,7kg hladilnega
sredstva. Prepovedano je uporabljati hitre metode odtajanja ali ciscenja
zamrznjenih delov, rezen ce to priporoca proizvajalec. Ne vrtajte luknje in
ne zgite klimatske naprave, pred uporabo pa preverite ali je crpalka za
hladilno sredstvo poskodovana.
- Klimatsko napravo je potrebno postaviti v prostor brez trajnega vira ognja, kot je kamin, plinski aparati, elektricni grelci in podobno. Upostevajte, da hladilno sredstvo nima vonja. Klimatsko napravo je potrebno postaviti na mesto, kjer bo kar najmanjsa moznost slucajnih mehanskih poskodb. Vzdrzevanje in popravilo klimatske naprave, ki uporablja hladilno sredstvo R32 se morajo opravljati sele kadar se opravijo vsi varnostni pregledi, da bi se zmanjsalo tveganje nesrece. Klimatska naprava mora biti namescena z nastavljenim ustavnim ventilom. * Pozorno preberite navodila pred vgradnjo, uporabo ali vzdrzevanjem.
Simbol
Opomba
Pojasnilo
OPOZORILO
Simbol opozarja, da aparat uporablja vnetljivo hladilno
sredstvo. Ce sredstvo uhaja in pride v stik z zunanjim virom ognja, obstaja
nevarnost pozara.
POZOR
Simbol opozarja, da je potrebno pozorno prebrati navodila za uporabo.
POZOR POZOR
Simbol opozarja, da mora servisno osebje rokovati z opremo upostevajoc
navodila.
Simbol opozarja, da so dostopne informacije kot so navodila za uporabo ali
namestitev.
– 1 –
Varnostne informacije
Nepravilna namestitev ali uporaba zaradi neupostevanja danih navodil lahko povzroci telesne poskodbe ali materialno skodo.
Stopnja nevarnosti se deli na naslednje kategorije:
OPOZORILO
Ta simbol opozarja na nevarnost smrtnih oz. hudih telesnih poskodb
POZOR Ta simbol opozarja na nevarnost telesnih poskodb ali materialne skode.
OPOZORILO Aparat lahko uporabljajo otroci starejsi od 8 let in osebe z
zmanjsanimi telesnimi, zaznavnimi in umskimi sposobnostmi oz. s pomanjkanjem
izkusenj in znanja, vendar le v kolikor so pod nadzorom in so jim podana
navodila za varno uporabo naprave ter razumejo nevarnosti, do katerih lahko
pride. Otroci se ne smejo igrati z napravo. Otroci ne smejo cistiti oz.
vzdrzevati naprave brez nadzora.
(Samo za klimatske naprave z oznako CE)
Ta naprava ni namenjena uporabi od strani oseb (vkljucno z otroci) z
zmanjsanimi telesnimi, zaznavnimi ali umskimi sposobnostmi, ali s
pomanjkljivim znanjem oz. izkusnjami, razen ce so pod nadzorom in so jim
podana navodila od strani osebe, ki je odgovorna za njihovo varnost. Otroke je
potrebno nadzirati, da se ne bi igrali z napravo.
(Razen za klimatske naprave z oznako CE)
-2-
Varnostne informacije
Klimatska naprava mora biti ozemljena. Nepopolna ozemljitev lahko povzroci elektricni udar.
Ce naprave dlje casa ne nameravate
uporabljati, zaradi
varnosti izvlecite
vtikac (ali izklopite varovalko).
Pazite da se notranja enota ali daljinski upravljalnik ne zmocijo oz. da niso predolgo izpostavljeni vlagi.
Ozemljitvenega vodnika naprave ne namescajte na cev za plin, strelovod ali ozemljitev telefona.
V kolikor je napajalni Med obratovanjem
kabel poskodovan, ga naprave ne vlecite
mora zamenjati proizvajalec ali
vtikaca z mokrimi rokami.
pooblasceni serviser
oz. ustrezno
usposobljeno osebje.
V nasprotnem lahko pride do kratkega stika.
Ne prikljucujte naprave na podaljsek, na kateri so prikljuceni drugi aparati.
To lahko privede do elektricnega udara.
Pred ciscenjem in
Pri odklopu iz
vzdrzevanjem naprave, vticnice, ne vlecite
vedno najprej ugasnite kabla.
napravo in jo odklopite
z el. napajanja.
V nasprotnem lahko pride do elektricnega udara in celo pozara ter eksplozije.
Cevi prikljucene na aparat nimajo vira priziganja.
V nasprotnem lahko pride do elektricnega udara.
Skoda, ki nastane pri vlecenju kabla, lahko povzroci elektricni udar.
-3-
Varnostne informacije
Naprave ne
Ne uporabljajte
Nikoli ne poskusajte
namescajte v blizino tekocine ali
sami popravljati
vnetljivega plina ali korozivnega sredstva klimatske naprave.
tekocine. Razdalja za ciscenje klimatske mora biti najmanj 1 m. naprave in je ne
posipajte z vodo ali
drugo tekocino.
To lahko privede do pozara in celo eksplozije.
Klimatske naprave ne uporabljajte ob nevihtah.
Nestrokovno popravilo lahko
povzroci pozar ali eksplozijo. Za
To lahko privede do elektricnega vse vrste popravil stopite v stik s
udara ali skode na napravi.
pooblascenim serviserjem.
Ne vtikajte rok ali
Prosimo preverite ali
kakrsnihkoli
so nosilci za zunanjo
predmetov v odvodne enoto dovolj cvrsto
in dovodne cevi.
namesceni.
Stikalo mora biti izklopljeno, da ne bi prislo do poskodb.
Ne postavljajte ovir v blizino odvodnih in dovodnih odprtin za zrak.
To lahko privede do telesnih poskodb ali poskodbe naprave.
Ne dovolite, da klimatska naprava piha v smeri grelnega telesa.
Vkolikor so poskodovani, lahko pride do padanja enota in hudih telesnih
poskodb.
Naprava mora biti namescena v skladu z veljavnimi zakonskimi predpisi za
prikljucitev vezja.
V nasprotnem bo zmogljivost hlajenja oz. gretja omejena, lahko pa pride tudi do prenehanja obratovanja aparata.
Varovalko morate nastaviti da preprecite morebitni V nasprotnem lahko pride do
elektricni udar.
nepopolnega izgorevanja, kar lahko povzroci zastrupitev.
-4-
Varnostne informacije
Ta izdelek vsebuje fluorirane pline, ki povzrocajo ucinek tople grede.
Uhajanje hladilnega sredstva prispeva k klimatskim spremembam. Hladilno
sredstvo z nizjo stopnjo potenciala vpliva na globalno segrevanje (GPW)
povzroca manjsi ucinek tople grede pri uhajanju v ozracje.
Ta aparat vsebuje hladilno sredstvo z GPW vrednostjo 675. To pomeni, da pri
izpuscanju 1 kg tega sredstva v ozracje pride do 675 krat vecjega vpliva na
globalno segrevanje, kot pri izpuscanju 1 kg CO2 za dobo 100 let. Nikoli ne
poskusajte sami posegati v tokokrog hladilnega sredstva ali razstavljati
napravo, vedno se obrnite na ustrezno usposobljeno osebje.
Poskrbite, da pod notranjo enoto ne postavljate: 1. Mikrovalovne pecice,
pecice in druge izvore toplote. 2. Racunalnike in druge naprave z velikim
elektrostaticnim
potencialom. 3. Vticnice, ki jih pogosto uporabljate. Povezovalne cevi med
notranjo in zunanjo enoto se ne premikajo, razen ce pride do poskodbe cevi.
Specifikacije varovalke so natisnjene na napisni plosci, kot npr. 3,15 A/250 V
AC itn.
WEEE Opozorilo
Pomen simbola precrtane kante za smeti. Ne odlagajte elektricnega aparata kot
navaden gospodinjski odpad, temvec ga odlagajte na za to namenjena zbiralna
mesta. Stopite v stik z lokalnimi oblastmi, da bi dobili informacije v zvezi z
razpolozljivimi moznostmi za odlaganje tovrstnega odpada. V kolikor elektricni
odpad prispe na deponijo ali smetisca, nevarne snovi lahko uhajajo do
podzemnih vod in tako prispejo v prehranjevalno verigo, kar ogroza zdravje
ljudi. Pri nakupu nove naprave oz. menjavi stare, je prodajalec v zakonski
obvezi, da prevzame stari aparat in poskrbi za ustrezno odlaganje, brezplacno.
-5-
Varnostne informacije
Ne drzite okna odprta dlje casa, kadar klimatska naprava obratuje.
POZOR
Ne stopajte na zunanjo enoto in nanjo ne postavljajte tezkih predmetov.
Ne uporabljajte klimatske naprave za drugotne namene kot so susenje perila, hlajenje hrane itd.
V nasprotnem bo prislo do slabsega To lahko privede do nesrece
ucinka hlajenja oz.gretja.
in telesnih poskodb oz. poskodbe naprave.
Ne izpostavljajte
Nastavite
telesa hladnemu
ustrezno
zraku dlje casa.
temperaturo.
Priporocamo, da razlika med zunanjo
in notranjo temperaturo ni prevelika.
To lahko povzroci zdravstvene tezave.
Ustrezne korekcije nastavitve temperature prispevajo k zmanjsanju nepotrebne
porabe elektricne energije.
V kolikor vasa klimatska naprava ni opremljena z napajalnim kablom in vtikacem, mora enopolno stikalo biti postavljeno v fiksno instalacijo, razdalja med kontakti pa ne sme biti manjsa od 3 mm.
V kolikor je klimatska naprava trajno povezana na elektricno napeljavo mora biti namesceno varnostno stikalo za diferencni tok za zascito proti eksploziji (RCD), rezidualni tok v napeljavi pa ne sme presegati 30 mA.
Napajalni tokokrog mora biti opremljen z zascito proti uhajanju elektricne energije in zracnim stikalom, cigar zmogljivost mora znasati vsaj 1,5 x najvecji tok.
Glede namestitve klimatske naprave, prosimo upostevajte spodnje odstavke v tem prirocniku.
Navodila za uporabo
Pogoji, pod katerimi ni predvidena uporaba
Pri vrednostih, navedenih v spodnji tabeli, lahko klimatska preneha delovati,
lahko pa se pojavijo tudi druge nepravilnosti.
Hlajenje
Zunanja Notarnja
49° C < 16° C
Gretje
Zunanja Notarnja
< -15° C > 30° C
- Ce je temperatura previsoka, se lahko sprozi varnostni sistem, ki bo klimatsko napravo ugasnil. Ce je temperatura prenizka, lahko izmenjevalnik toplote klimatske naprave zmrzne, kar lahko povzroci uhajanje tekocine in druge okvare. Pri dolgotrajnem hlajenju in susenju zraka, pri relativni vlaznosti vecji od 80% (vrata ali okna odprta), lahko pride do kondenzacije in kapljanja na izhodu za zrak.
- Klimatski razred je T1 in se nanasa na standard ISO 5151.
Opombe pri gretju
- Ventilator notarnje enote ne zacne delovati takoj po zacetku gretja, da ne bi prihal hladen zrak.
- Ko je zunaj mokro in mrzlo, se bo na zunanji enoti oz. na izmenjevalniku toplote tvorila zmrzal, ki vpliva na zmogljivost gretja. V tem primeru bo klimatska naprava sprozila odmrzovanje. Med odmrzovanjem bo klimatska naprava prenehala delovati od 5 do 12 minut. Iz zunanje enote lahko med odmrzovanjem zacne uhajati para. To je normalno, nastaja kot posledica hitrega odmrzovanja. * Napravo bo zacela greti, takoj ko konca z odmrzovanjem.
Opombe pri ugasanju
- Pri izklopu klimatske naprave, bo glavni krmilnik samodejno dolocil ali takoj
prenehati z delovanjem ali sele po nekaj desetinah sekund obratovanja pri nizji frekvenci in pretoku zraka.
-7-
Opombe za uporabo
Obratovanje v izjemnih okoliscinah
V kolikor je daljinski upravljalnik izgubljen ali poskodovan, uporabite gumb za prisilno obratovanje. V kolikor pritisnete ta gumb, kadar je naprava ugasnjena, bo klimatska naprava pricela obratovati v samodejnem nacinu obratovanja. *V kolikor pritisnete ta gumb, kadar naprava obratuje, se bo klimatska naprava ugasnila.
Gumb za prisilno obratovanje
Uravnavanje smeri pihanja
1. Uporabite gumbe za spremembo smeri pihanja na daljinskem upravljalniku. Za
podrobnosti poglejte navodila za uporabo daljinskega upravljalnika.
2. Pri modelih brez funkcije usmerjanja zraka levo-desno, je zakrilca
potrebno premakniti rocno.
Opomba: Zakrilca premikajte rocno samo, kadar naprava ne obratuje, da ne bi
prislo do telesnih
poskodb.
Nikoli ne vtikajte prstov v zracni dovod ali odvod, kadar klimatska naprava
obratuje.
Specificno opozorilo
1. Odprite sprednji pokrov notranje enote. 2. Konektorji (na sliki) se ne
smejo dotikati terminalske plosce, in so postavljeni kot je prikazano na
sliki.
Konektor
Kabel l Kabel 2 Terminalska plosca
– 8 –
Resetka dovoda zraka Sprednji pokrov
Filter zraka
Reza za zrak
Zakrilca za usmerjanje zraka
Nazivi delov naprave
Notarnja enota
Dovod zraka
Prisilno stikalo
Odvod zraka
Daljinski upravljalnik
Zunanja enota
Napajalni kabel
Zascitni obroc cevi
Resetka zracnega
odvoda
Povezovalna cev Drenazna cev
Odvod zraka
Opomba: Vse slike v teh navodilih so namenjene le za ponazoritev. Vasa
klimatska naprava je lahko drugacna od prikazane Vtic, Wifi funkcija, funkcija
negativnih ionov, vodoravno in navpicno usmerjanje zraka so opcijske, odvisne
od konkretnega modela.
-9-
Ciscenje in vzdrzevanje
Opozorilo
- Pred ciscenjem klimatske naprave, jo morate ugasniti in izklopiti iz elektricnega napajanja, ter pocakati najmanj 5 minut, v nasprotnem lahko pride do elektricnega udara. Ne mocite klimatske naprave, da ne bi prislo do elektricnega udara. Nikoli, pod nobenim pogojem, ne izpirajte klimatske naprave z vodo. Hlapljive tekocine kot so razredcilec ali bencin lahko poskodujejo ohisje klimatske naprave, zato za ciscenje prosimo uporabljajte samo vlazno mehko krpo in blago cistilno sredstvo ter posusite s suho krpo. * Redno cistite zracni filter, da ne bi prislo do zamasenja in posledicno slabse zmogljivosti naprave. Ce je v prostoru veliko praha, je potrebno filter cistiti bolj pogosto. Po odstranitvi filtra se ne dotikajte zakrilc notranje enote, prav tako pa ne ravnajte grobo s cevjo za hladilno sredstvo, da ne bi prislo do poskodb.
Ciscenje pokrova
Kadar se notranja enota umaze, jo nezno ocistite z izcejeno krpo, predhodno namoceno v vodi temperature najvec 40 stopinj Celzija, med ciscenjem pa ne odpirajte pokrova.
Ciscenje zracnega filtra
Odstranjevanje zracnega filtra
1. Z obema rokama odprite pokrov na kant v smeri puscice. 2. Odstranite zracni filter iz reze.
Cisenje zracnega filtra Uporabite sesalnik ali izperite filter z vodo, ce pa je filter zelo umazan (npr. zamascen), ga ocistite z mlacno vodo (pod 45 stopinj Celzija) in blagim detergentom, ter ga nato postavite na osenceno mesto, da se posusi.
-10-
Ciscenje in vzdrzevanje
Namestitev filtra 1. Ponovo namestite posusen filter v obratnem vrstnem redu
korakov, nato spustite pokrov, da zaskoci.
Pred uporabo preverite
1. Preverite ali so vsi zracni dovodi neovirani. 2. Preverite ali je odvod
drenazne cevi prost, in v primeru da je oviran takoj ocistite. 3. Preverite
ozemljitev. 4. Preverite ali so baterije namescene v daljinskem upravljalniku.
5. Preverite ali so nosilci zunanje enote poskodovani, v primeru da je tako,
se prosimo obrnite na nas najblizji servis.
Vzdrzevanje po uporabi
1. Izklopite napravo iz elektricnega napajanja, izklopite glavno stikalo in
odstranite baterije iz daljinskega upravljalnika. 2. Ocistite filter in ohisje
enote. 3. Odstranite umazanijo in trdne delce z zunanje enote. 4. Preverite
ali so nosilci zunanje enote poskodovani, v primeru da je tako, se prosimo
obrnite na nas najblizji servis.
-11 –
Odpravljanje tezav
Pozor
*Ne poskusajte sami popravljati klimatske naprave, saj lahko pride do elektricnega
udara, pozara ali eksplozije. Prosimo stopite v stik s pooblascenim
serviserjem in dovolite da ustrezno usposobljeno osebje opravi popravilo. Pred
kontaktiranjem
servisa preverite spodaj navedene simptome, da sebi prihranite cas in denar.
Tezava
Odpravljanje tezav
Klimatska
naprava se sploh ne prizge.
Ali je prislo do izpada el. napajanja? Se je vtic izkljucil iz vticnice? Je napetost previsoka ali prenizka ?(naj preverijo profesionalci) Ali funkcijo casovnika pravilno uporabljate? Ali se aktivira elektricna varovalka?
Klimatska naprava ne more zaceti takoj obratovati po izklopu.
Obratovanje klimatske naprave se prekine po kratkem obdobju obratovanja
Ce poskusite klimatsko napravo prizgati takoj po zaustavitvi, bo varnostni
sistem odlozil zacetek obratovanja 3-5 minut.
· Mozno je, da je dosezena nastavljena temperatura. To je normalna pojava.
· Mozno je, da je naprava v nacinu odtajanja. Samodejno bo ponovno zacela
obratovati po odtajanju.
·Mozno je, da je nastavljen casovnik za izklop. Preprosto ponovno zazenite
napravo.
Zrak piha iz klimatske naprave, vendar ucinkovitost gretja ali hlajenja ni
dobra.
Iz notranje enote prihaja cuden vonj.
· Zamasen oz. umazan filter, oviran dovod ali odvod zraka, zelo ozek kot
zakrilc, vse to lahko vpliva na ucinkovitost gretja ali hlajenja. Ocistite
filter, odstranite ovire in spremenite kot zakrilc. · Odprta okna oz. vrata
ter odvodni ventilatorji zraka lahko povzrocijo slabso ucinkovitost gretja oz.
hlajenja. Poskusite zapreti okna, vrata, ugasniti oz. zapreti odvodni
ventilator · Pomozna funkcija gretja ni aktivirana pri gretju, kar lahko
povzroci slabsi ucinek. Aktivirajte pomozno funkcijo gretja (samo modeli s
pomozno funkcijo gretja) · Nepravilno nastavljen nacin obratovanja,
temperatura in nastavitev pihanja. Ponovno izberite nacin delovanja in
nastavite ustrezno temperaturo ter moc pihanja.
· Klima ureaj sam po sebi nema neprijatan miris. Ukoliko se on pojavi, mogua
je akumulacija mirisa iz okruzenja.
Ocistite filter ili aktivirajte funkciju cisenja.
Odpravljanje tezav
Med delovanjem klimatske naprave je slisno klokotanje.
Pri zagonu ali ustavljanju delovanja lahko slisite zvok klikanja.
Notarnja enota proizvaja nenavaden hrup.
Kadar se klimatska naprava ustavi ali zazene, ali se kompresor med
obratovanjem naprave ustavi, vcasih lahko slisite sumenje ali klokotanje, kot
da tece voda. To je zvok pretoka sredstva za hlajenje, ne gre za okvaro.
To je zvok trenja, ki ga povzroca sirjenje plosce ali drugih delov zaradi
spremembe temperature. Ne gre za okvaro.
r
· Zvok ventilatorja ali tokokroga kompresorja pri izklopu ali vklopu. · Pri
zacetku ali ustavitvi odtajanja, se slisi hrup. -To je zaradi pretoka
hladilnega sredstva v obratno smer, ne gre za okvaro. · Prevec nabranega praha
na filtru notranje enote lahko povzroci
spremembe v hrupu. Redno cistite zracne filtre. · Hrup zaradi uporabe
najmocnejse nastavitve pihanja. Ne gre za okvaro, ce vam ne ugaja, zmanjsajte
moc pihanja z najvisje nastavitve.
Na povrsini notarnje enote so se pojavile kapljice vode.
· Kadar je vlaznost zraka visoka, se lahko pojavijo kapljice kondenza na
zracnih odvodih, pokrovu itd. To je normalna pojava.
· Daljse obratovanje v rezimu hlajenja v odprtih prostorih lahko povzroci
nabiranje kondenza.
Preozek kot odpiranja zakrilc prav tako lahko povzroci nabiranje kondenza.
Odprite zakrilca na sirsi kot.
Vcasih bo med hlajenjem iz klimatske naprave izhajala rahla meglica.
· Do tega lahko pride, ko sta notranja temperatura in vlaga visoki.
Vzrok je hitro hlajenje notranjega zraka. Po dolocenem casu bo meglica
izginila.
V naslednjih primerih takoj prekinite z uporabo in izkljucite napravo iz elektricne vticnice, ter se posvetujte z dobaviteljem:
Med delovanjem naprave se slisi mocan hrup ali je cutiti grozen vonj. Elektricni kabel ali vtic se nenavadno segrevata. Po napravi ali daljincu je nenamerno polita voda. Pogosto se aktivira zracna ali zascitna varovalka.
-13-
Opombe glede namestitve
Pomembne opombe Pred namestitvijo, prosimo stopite v stik z pooblascenim
serviserjem, namestitev mora izvesti pooblasceno osebje, saj v nasprotnem
primeru proizvajalec ne more jamciti za varno delovanje aparata. Namestitev
naprave mora izvesti ustrezno usposobljeno osebje, v
skladu z lokalnimi predpisi in tem prirocnikom. Nakon ugradnje mora se
ispitati curenje rashladnog sredstva. Ce napravo zelite namestiti na drugem
mestu, stopite v stik s
pooblascenim serviserjem.
Pregled pri odpiranju embalaze · Odprite embalazo in preverite klimatsko
napravo v dobro prezracenem prostoru (odprite vrata, okna) brez odprtega vira
ognja oz. isker.
· Pred odpiranjem embalaze zunanje enote, ustrezno usposobljeno osebje mora
preveriti uhajanje hladilnega sredstva. Ce pride do uhajanja, prekinite
namestitev naprave. · Protipozarna oprema in varnostni ukrepi glede staticne
elektrite morajo biti upostevani pred pregledom. Nato preglejte tokokrog
hladilnega sredstva, morebitne poskodbe.
Varnostna nacela pri namestitvi klimatske naprave
· Pred namestitvijo mora biti pripravljena protipozarna oprema. · Prostor mora biti dobro prezracen (odprite okna, vrata).
·prVoisritoordup, rktejegraseognnajah,aijsakhrela,dpilrnizogsarneedsctigvoarRet3e2,.se ne smejo nahajati v
1· 0P0o%trebbonmobjeazunpihosotebvlaactiil
ukrepe glede in rokavic.
staticne
elektrike,
npr.
uporaba
v·eNsacparasvpaozsatozpakzannaavmanejsetiutvhea.janja hladilnega sredstva mora obratovati
s·pCreemplrjianjtaemkeosntcitevni tpraricdiejodvopurhoasjtaonrujadholkaldeirlnneegaprsidreeddsotvvaaRrn3e2r,apvonzi.oCrneo uhajanje hladilnega sredstva vpliva na ucinkovitost klimatske naprave, takoj prekinite postopek. Najprej je potrebno vakuumski izprazniti
klimatsko napravo, katera mora biti poslana na ustrezno vzdrzevanje.
s·tEatleickntoricenleekntraikporasvee,nsetiskmaleaj,ovnticaeh,avjatitci npiocde,mvierestotomplontaeminesntaitvperanvoetrsanje enote.
t·aKkolimzaatsnkaamneasptirteavvakomtovrzadbrzitei vnaanmjee,sicneknjearnnei
mestu, ovir, ki
kjer bo dostopna bi lahko zmanjsale
pretok zraka pri dovodih in odvodih. Prav tako na tem mestu ne smejo
biti prisotna grelna telesa, vnetljive ali eksplozivne snovi.
-14-
Opombe glede namestitve
· Ce pri namescanju ali popravilu klimatske naprave napeljava hladilnega
sredstva ni dovolj dolga, mora biti celotna napeljava zamenjana z novo v
skladu z originalno specifikacijo. Podaljski niso dovoljeni. · Uporabljajte
novo cev za napeljavo hladilnega sredstva, razen ce ni opravljena razsiritev
koncev cevi.
Zahteve polozaja namestitve Izogibajte se mestom v blizini uhajanj vnetljivih
plinov ali eksplozivnih
snovi. Izogibajte se mestom, kjer so prisotna mocna elektromagnetna polja.
Izogibajte se mestom, kjer je prisoten mocan hrup in vibracije. Izogibajte se
mestom, kjer so prisotni mocni atmosferski vplivi (pesceni
vetrovi, direktna soncna svetloba, izvori visoke temperature). Izogibajte se
mestom, ki so zlahka dostopna otrokom. Razdalja med notranjo in zunanjo enoto
naj bo cim manjsa. Izberite prostor, kjer je enostavno opravljati vzdrzevanje,
in ki je dobro
prezracen. Zunanja enota ne sme biti namescena na stopnisce, izhod, prehod,
pozarne stopnice ali drugo javno povrsino. Zunanjo enoto namestite cim dlje od
oken sosedov in zelenih rastlin.
Pregled namestitvenega okolja · Preverite napisno tablico na zunanji enoti, da
bi preverili ali naprava
uporablja hladilno sredstvo R32. · Preverite velikost prostora. Prostor ne sme
biti manjsi od naznacenega
v specifikaciji (5 m2). Zunanja enota mora biti postavljena na mestu z dobro
ventilacijo. · Preverite okolico mesta namestitve: R32 ne sme biti namescen v
prilozenem rezerviranem prostoru stavbe. · Kadar uporabljate elektricni
vrtalnik za luknje v zidu, najprej preverite kje poteka elektricna, vodovodna
ali plinska napeljava.
Zahteve za montazno konstrukcijo · Nosilci za namestitev morajo izpolnjevati
dolocene drzavne ali industrijske standarde v smislu zdrzljivosti, tako se da
zavarjena mesta zascitena pred rjo. · Nosilec za montazo in njegova povrsina
morajo zdrzati 4-kratno tezo enote, tj. 200 kg.
-15-
Opombe glede namestitve
· Nosilci zunanje enote morajo biti pritrjeni z ekspanzijskimi vijaki. · Potrebno je zagotoviti varno namestitev, ne glede na tip stene na katero se namesca naprava, da bi se preprecila moznost padanja naprave in hudih telesnih poskodb.
Zahteve glede elektricne varnosti
n· aPpreavjaelnrietegadakanbalzaivmnaornaappreatvostat knoapursatrveezuastitrderzzaavnnaimpapjarnejdup,ipsoremm.er
o· bKvaedzanrajeupmraakbsaimzraalcnni etogkakslitmikaatlaskoezn. astpikraavlaezeanapkreaplrievceecvjia1n6jeAu,hjeanjaja elektricnega toka, z zascitnimi sistemi.
e· lOekbtsriecgnoobnraaptoavjaannjjea
je 90-110% nazivne napetosti. Vendar lahko povzroci elektricni udar ali pozar.
nestabilno
s· nNoavjmmiaznnjsaasado1v,5oljmen. a razdalja med klimatsko napravo in vnetljivimi
p· oPvreezdopvoavlneizmovkaanbjleomm
notranje in zunanje naprave z elektricnim morate izmeriti razdaljo in pripraviti ustrezno
dolzino
kabla.
· Vrste kablov: Napajalni kabel: H07RN-F ili H05RN-F;
Povezovalni kabel: H07RN-F or H05RN-F;
· Minimalna povrsina profila napajalnega kabla in povezovalnega kabla.
Severna Amerika Amperaza AWG naprave (A)
10
18
13
16
18
14
25
12
30
10
40
8
Druge regije Nazivna amperaza (A) Nazivni povrsina
profila (mm2)
3 i < 6
0.75
6 i <10
1
10 i <16
1.5
16 i <25
2.5
25 i <32
4
32 i <40
6
· Dolzina povezovalnega kabla med notranjo in zunanjo enoto, napajalnega kabla, varovalke, stikala, vse to je odvisno od najvecje amperaze naprave, ki je navedena na napisni tablici na boku enote. Preverite podatke z napisne tablice pri izboru kabla, varovalk ali stikal. · Opomba: Osnovna oznacba kabla se nanasa na podrobni diagram napeljave in se nahaja na napravi, ki ste jo kupili.
-16-
Opombe glede namestitve
Zahteve za dela na visini · Pri namestitvi naprave pri dveh metrih ali vec od
tal, se mora uporabljati varnostne pasove in vrvi primerne zdrzljivosti, da ne
pride do smrtne nezgode ali telesnih poskodb in materialne skode.
Zahteve za ozemljitev
· Kjer je klimatska naprava elektricna naprava razreda I, mora biti zanesljivo
ozemljena. · Ne pritrujte ozemljitveno zico na plinsko ali vodovodno cev,
strelovod, telefonsko linijo ali slabo ozemljen tokokrog. · Ozemljitvena zica
je posebej nacrtovana izkljucno za ta namen in se ne sme pritrjevati z
navadnim vijakom. · Preporuceni precnik meuveznog kabla je kao u uputstvu,
tipa prikljucka za ,,nulu”, koji ispunjava lokalne standarde (unutrasnji
precnik prikljucka za ,,nulu” treba da odgovara velicini zavrtnja jedinice, ne
vise od 4.2mm). Nakon ugradnje proverite da li su zavrtnji u dobrom polozaju i
da li postoji opasnost od labavljenja.
Drugo
· Nacin povezovanja klimatske naprave in napajalnega kabla in povezava med
vsakim elementom je podrobno opisana v diagramu napeljave. · Model in nazivne
vrednosti varovalke morajo ustrezati elektricni napeljavi in specifikacijam
klimatske naprave.
Notranja enota
Vsebina paketa
Zunanja enota
Naziv
Kolicina En.
Naziv
Kolicina En.
Notarnja enota
1
Set
Zunanja enota
Daljinski upravljalnik
1
Kos Povezovalna cev
Baterije (7#)
2
Kos
Plasticni ovoj
1
Set
2
Kos.
1
Navoj
Navodila
1
Set
Zasc. ovoj za cev
1
Kos.
Odvodna cev
1
Kos
Tesnilo
1
PAKET
OPOMBA: Spremljajoca oprema je.odvisna od razpolozljive embalaze, prosimo
za razumevanje, v kolikor pride do neskladja.
-17-
Namestitev notranje enote
Shema namestitve notranje enote
Oddaljenost od stropa
Oddaljenost od zida
20cm ob strani
15 cm ali vec
Oddaljenost od zida
20cm ob strani
230-260 cm
Oddaljenost od tal
Namestitev nosilca
1. Zid, na katerem se namesca notranja enota, mora cvrst ter stabilen, da ne
bi prihajalo do vibracij. 2. Uporabite krizni tip vijaka za pritrditev
okvirja, preverite navpicno in vodoravno poravnavo nosilca. 3. Okvir nosilca
po namestitvi povlecite z roko, da preverite ali je trdno namescen.
Odprtina za cev
1. Napravite luknjo z elektricnim svedrom, na
vnaprej dolocenem polozaju, odprtina mora biti
navzven nagnjena rahlo navzdol, nekje od 5
do 10 stopinj.
2. Da bi zascitili cev in kable pred poskodbami pri
namestitvi, in glodavcev, ki morda zivijo v
votlem zidu, se namesti zascitni obroc ter zatesni s
kitom.
Kit
Opomba: Navadno je luknja v zidu velikosti
60mm 80mm. Pri izbiri mesta za luknjo,
se izogibajte mestom, kjer tece elektricna
napeljava in zelo trdnim zidnim povrsinam.
-18-
Obroc za zascitu cevi
Namestitev notranje enote
Potek cevi
1. V odvisnosti od polozaja enote, so cevi lahko speljane levo ali desno ob
strani (slika 1) ali zadaj navpicno (slika 2) (odvisno od dolzine cevi
notranje enote).
V primeru napeljave ob strani odrezite visek izhodnega nastavka na drugi
strani.
Sl. 1
Povezovalna cev odvod in kabli
Outlet material preparation
Sl. 2
Povezovalna
cev odvod in kabli
Povezava odvodne cevi
1. Odstranite nastavke in povlecite cev notranje enote iz ohisja. 2.
Prikljucite povezovalno cev na notranjo enoto. Ciljajte sredino cevi, privijte
konusno matico s prsti, ter jo nato zategnite z navornim kljucem, v smeri
prikazani na shemi desno. Primeren navor je naveden v spodnji tabeli.
Opomba: Natancno preverite, ali so na spojkah poskodbe. Povezovalne cevi med
notranjo enoto in zunanjo enoto se ponovno ne uporabljajo, razen ce so
konci cevi razsirjeni.
Tabela navora pri privijanju
Premer cevi (mm)
6. 35 9/9. 52 12/12. 7
15. 88 19. 05
Navor (N · m) 6/
15–25 35–40 45–60 73–78 75–80
Cev notranje enote
Cev s konusno matico
Vijacni kljuc
Navorni kljuc
Ovoj cevi
1. Uporabite izolacijski ovoj za zascito napeljave Notranje cevi, nato pa
uporabite izolacijski material da zaprete izolacijo cevi, da ne bi prislo do
nabiranja vode na vodu. 2. Povezite izhod za vodo z odvodnimi cevmi in se
prepricajte da so povezovalna cev, kabli in odvodna cev ravni. 3. Uporabite
plasticne vezi za spajanje povezovalne, odvodne cevi in kablov. Cevi morajo
imeti nagib navzdol.
– 19-
Povezovalna odvodna cev ter kabli
Plasticni ovoj
Namestitev notranje enote
Pritrditev notranje enote
1. Obesite notranjo enoto na nosilni okvir in jo nato premaknite levo in
desno, da preverite ali so se kavlji dobro usedli v okvir. 2.Pritisnite na
spodnjo levo in zgornjo desno stran enote, dokler da so kavlji zaskocili v
okvir.
Diagram elektricne napeljave
Ce ima Vasa klimatska naprava elektricni kabel z vticem, je notranja napeljava
urejena v tovarni in aparata ni potrebno posebno povezovati. Ce napajalnega
kabla ni, se naprava mora povezati v skladu s spodnjo shemo.
Po namestitivi preverite ali so: 1. Vijaki v dobrem polozaju in ali obstaja
nevarnost odvijanja. 2. Ali je konektor plosce prikazovalnika postavljen v
pravi polozaj in ne dotikajte se plosce. 3. Ali je kontrolna skatlica dobro
zaprta.
Stalna hitrost
Variabilna hitrost
Konektor
Zunanja enota
Zunanja enota
Ce imate konektor, ga povezite direktno.
Zunanja enota
Zunanja enota
OPOMBA:
Prirocnik navadno vsebuje diagrame napeljave za razlicne vrste A/C napajanja.
Ne moremo izkljuciti moznosti, da manjkajo diagrami za posebne nacine
napeljave. Ti diagrami so samo za orientacijo. Ce ne ustrezajo vasem izdelku,
poglejte podroben diagram za povezovanje naprave, ki ste jo kupili.
– 20-
Namestitev zunanje enote
Shema za natevmest zunanje enote
Prostor do ovire
Pretok zraka
Prostor do ovire
Prostor do ovire
Pretok zraka
Vijaki za namestitev zunanje enote
Leve namestitvene nozice
Dimenzije zunanje enote W1(W2)HD) (mm)
665(710)x420x280
600(645)x485x260
660(710)x500x240
700(745)x500x255
730(780)x545x285
760(810)x545x285
Vhod zraka
Desne namestitvene nozice
790(840)x550x290 800(860)x545x315 800(850)x590(690)x310
825(880)x655x310
900(950)x700x350
900(950)x795x330
Izhod zraka
970(1044)x803x395
A (mm) 430 400 500 460 540 540 545 545 540 540 630 535 675
B (mm) 280 290 260 260
280 280 300 315 325 335 350 350 409
Namestitev cevi
Povezite zunanjo enoto s povezovalno cevjo:
Namestite navoj povezovalne cevi na navoj na zapornem
ventilu in jo privijte s prsti. Nato zategnite matico z
navornim kljucem. Ce podaljsate cevno napeljavo, morate dodati dodatno
Zaporni ventil
kolicino hladilnega sredstva, da ne bi prislo do zmanjsane
ucinkovitosti delovanja klimatske naprave.
Duolzina cevi Dodatna kolicina hladilnega sredstva
s=5M
Nije potrebna
Kolicina hladil. sredstva za
enoto 5-
15M
CCs=12000Btu
16g/m
s=1kg
CC3=18000Btu 24g/m =S2kg
Konusna matica
Opomba: 1. Tabela je izkljucno za orijentacijo. 2. Spojne cevi izmeu unutrasnje i spoljne jedinice se ne koriste ponovo, osim ako se ne uradi prosiravanje krajeva cevi. 3. Nakon ugradnje proverite da li je poklopac zaustavnog ventila dobro postavljen
-21-
Povezovalna cev Tekocinska cev Plinska cev
Kljuc
Pokrov zapornega ventila
Namestitev zunanje enote
Elektricna povezava
1. Odvijte vijake in odstranite pokrov elektricnega sklopa. 2. Povezite kable
na ustrezne terminale na terminalni plosci zunanje enote (glej diagram
elektricne napeljave), in ce so na prikljucku prisotni signali, samo napravite
spoj po dolzini. 3. Zemlja: Ostranite ozemljitveni vijak iz nosilca, postavite
zico Ozemljitev in jo privijte v ozemljitveno luknjo. 4. Kable dobro pritrdite
s pritrdilci. 5. Vrnite pokrov na svoje mesto in ga privijte z vijaki.
Pokrov elektronskih delov
Diagram elektricne povezave
Stalna hitrost
Variabilna hitrost
Napajanje
Notranja enota
Notranja enota
Napajanje
Napajanje
Notranja enota
Notranja enota
Konektor
Napajanje
OPOMBA:
Ce imate konektor, ga povezite direktno.
Prirocnik navadno vsebuje diagrame napeljave za razlicne vrste A/C napajanja.
Ne moremo izkljuciti moznosti, da manjkajo diagrami za posebne nacine napeljave.
Ti diagrami so samo za orientacijo. Ce ne ustrezajo vasem izdelku, poglejte podroben diagram zanjo.
-22-
Namestitev zunanje enote
Iztiskanje zraka iz sistema
Za hladilno sredstvo R32 se uporablja posebna vakumska crpalka.
Pred opravili na klimatski napravi, odstranite pokrov zapornega ventila (ventil za plin in tekocino) in se prepricajte, da ste ga zategnili (da bi se preprecilo uhajanje plina)
1. Da bi se preprecilo uhajanje oz curljanje, zategnite matice na vseh ceveh. 2. Povezite ventil, cev za polnjenje, glavni ventil in vakumsko crpalko. 3. Popolnoma odprite rocico in pustite crpalko da obratuje najmanj 15 minut, ter preverite ali se na multimetru prikazuje -0,1 Mpa (-76 cmHg) 4. Po uporabi vakuma, odprite ventil s heksagonalnim kljucem. 5. Preverite ali odprti in odprti spoji dobro tesnijo.
Merilec vakuuma -76cm Hg
Rocaj Hi
Polnilna cev
Merilec tlaka Ventil zbralnika Rocaj Lo
Polnilna cev
Vakuumska crpalka
Zaporni ventil (tekocina)
Zaporni ventil (plin
Zunanji odvod kondenzata (samo tip toplotna crpalka)
Kadar enota greje, voda ki se kondenzira in odtajajoca se voda lahko zanesljivo odteka skozi drenazno cev. Namestitev: Namestite nastavek za zunanji odvod v luknjo premera 25 na dnu zunanje enote, ter namestite cev na nastavek, tako da lahko voda odteka na primerno mesto.
Znanji odvod
-23-
Preverjanje in preizkus po namestitvi
Preveriti po namestitvi
Preverjanje elektricne varnosti 1.Ali je napajalna napetost ustrezna. 2.Ali ni
prislo do napak pri povezovanju napajalnih, ozemljitvenih in signalnih zic na
terminalih. 3.Ali je ozemljitveni vod dobro ozemljen. Preverjanje varne
namestitve 1.Ali je namestitev varna. 2.Ali odvod za vodo dobro deluje. 3.Ali
so elektricne in cevne napeljave dobro namescene. 4.Preverite, da v enoti niso
ostali zunanji delci ali orodje. Preverjanje uhajanja hladilnega sredstva V
odvisnosti od nacina namestitve, lahko uporabljate naslednje nacine
preverjanja puscanja, na delih kot so stirje prikljucki notranje in zunanje
enote in na zapornih ter trismernih ventilih. 1. Nacin z mehurcki: Nanesite
enakomeren sloj z vodo pomesanega mila na predel, ki ga zelite preveriti in
pozorno spremljajte ali se pojavljajo mehurcki. 2. Nacin z instrumenti: Sondo
za preverjanje puscanja v skladu z navodili za uporabo usmerite na del, ki ga
zelite preveriti.
Preizkusno obratovanje
Priprava za preizkusno obratovanje: Preverite, da so vse cevi in kabli
ustrezno povezani.
Preverite, ce so ventili na plinski in tekocinski strani popolnome odprti.
Povezite napajani kabel na samostojen elektricni vtic. Namestite baterije v
daljinec. Nacin preizkusanja 1. Vklopite napajanje in pritisnite na IN/OFF
gumb na daljincu, da zaznete klimatsko napravo. 2. Izberite Hlajenje, Gretje
(ni na voljo pri modelih ki imajo samo hlajenje), SWING in druge nacine
delovanja in preverite ali delujejo dobro.
-24-
Vzdrzevanje
Pozor: Glede popravil, vzdrzevanja ali odlaganja odsluzenega izdelka, se
obrnite na pooblasceni servis. Vzdrzevalni posegi od strani nestrokovne osebe
lahko povzrocijo nevarnost. Napolnite klimatsko napravo s hladilnim sredstvom
R32 in vzdrzujte napravo strogo v skladu s proizvajalcevimi navodili. Ti
poglavje se osredotoca na posebne vzdrzevalne zahteve za naprave, ki
uporabljajo hladilno sredstvo R32. Prosite serviserja, da prebere servisni
prirocnik izdelka za podrobnejse informacije.
Zahteve glede kvalifikacij servisnega osebja
1. Poleg obicajnih procedur v zvezi s popravilom hladilnih naprav je potrebno
dodatna usposobljenost glede rokovanja z napravmi, ki uporabljajo vnetljive
pline. V mnogih drzavah to vrsto usposabljanja opravljajo akreditirane drzavne
organizacije v skladu s standardi predpisanimi z zakonom. Usposobljenost se
dokazuje z ustreznim certifikatom oz. spricevalom.
2. Vzdrzevanje in popravilo klimatskih naprav se mora opravljati po postopku,
ki ga priporoca proizvajalec. Ce so za popravilo potrebni drugi strokovnjaki,
se mora postopek izvesti pod nadzorom oseb, ki imajo kvalifikacije za
popravilo klimatskih naprav, ki uporabljajo vnetljiva hladilna sredstva.
Preverjanje prostora
Pred kakrsnim koli posegom na napravi, ki uporablja hladilno sredstvo R32,
morajo biti opravljeni ustrezni varnostni ukrepi, da bi se zmanjsala nevarnost
nesrece. Preverite, ali je prostor dobro prezracen, prav tako preverite
ustrezno delovanje prozipozarne opreme in opreme proti staticni elektriki. Pri
posegu sledite naslednje varnostne ukrepe.
Operativni postopki
1. Delovno obmocje: Osebje, ki opravlja popravilo, kot tudi drugi, ki so
vkljuceni v delo, morajo vedeti s kaksnim delom imajo opravka. Delovno obmocje
je potrebno izolirati in preveriti pogoje, torej se prepricati, da v delovnem
obmocju ni vnetljivih snovi. 2. Preverjanje prisotnosti hladilnega sredstva:
Pred in med delom je potrebno z ustrezno merilno opremo spremljati delovno
obmocje, tako da serviser vedno ima pregled morebitne prisotnosti strupenih
ali vnetljivih snovi v zraku. Prepricajte se, da oprema za zaznavanje uhajanja
hladilnih sredstev lahko zaznava vsa hladilna sredstva v uporabi, da ni
iskrenja in da je vse dobro zaprto in zatesnjeno. 3. Gasilna oprema: V kolikor
se izvajajo kakrsnikoli vroci posegi na hladilni opremi in podobnem, je
obvezno imeti pri roki gasilni aparat. V blizini delovnega obmocja je potrebno
imeti suh prah ali aparat za gasenje pozara.
-25-
Vzdrzevanje
1.Brez virov ognja Nobena oseba, ki opravlja delo na hladilnem sistemu in
ceveh ne sme uporabljati vire ognja, isker in cesarkoli, kar bi lahko
povzrocilo pozar. Vsi viri ognja, vkljucno s cigaretnim dimom, morajo biti
dovolj oddaljeni od delovnega obmocja in shranjevalnega obmocja. Pred zacetkom
dela je potrebno preveriti prisotnost virov ognja. Znak ta prepoved kajenja
mora biti jasno izpostavljen. 2. Prezracevanje delovnega obmocja Poskrbite, da
je delovno podrocje odprto in dovolj prezraceno pred odpiranje hladilnega
sistema ali izvajanjem vrocih posegov. Prezracevanje prostora mora biti dobro
tekom celotnega trajanja del. 3. Preverjanje hladilne opreme Vkolikor se
menjajo elektricni deli, morajo ti deli biti ustreznega namena in
specifikacije. Potrebno je upostevati navodila proizvajalca in servisa. V
kolikor imate dvome, stopite v stik z proizvajalcem. Za namestitve delov, pri
katerih se uporabljajo vnetljive hladilne snovi je obvezno pregledati
naslednje: · Ali je kolicina polnjenja v skladu z velikostjo prostora v
katerem so deli namesceni. · Prezracevanje in vticnice delujejo pravilno in
neovirano. · V kolikor se uporablj indirektni hladilni tokokrog, je potrebno
preveriti ali je v
sekundarnem tokokrogu prisotno hladilno sredstvo. · Cev hladilnega sredstva
ali komponente se namescajo v polozaj, kjer je malo verjetno,
da bodo izpostavljene snovi, ki bi lahko privedla do korozije komponent, ki
vsebujejo hladilno sredstvo. 4. Preverjanje elektricnih naprav: Popravilo in
vzdrzevanje elektricnih komponent vkljucuje zacetne varnostne preglede in
postopke preverjanja komponent. Ce obstaja kakrsnakoli okvara, ki bi lahko
ogrozila varnost, se ne sme povezovati elektricno napajanje dokler se problem
ne resi na ustrezen nacin. Ce okvare ni moc odpraviti, vendar je nujno
nadaljevati z delom, se mora uporabiti primerna zacasna resitev. O okvari se
poroca lastniku opreme in vse zainteresirane strani se vkljucijo v
posvetovanje. Zacetni varnostni pregledi vkljucujejo: Praznitev
kondezatorja: to je potrebno opraviti pazljivo, da ne bi prislo do iskrenja
Pregled, da bi se zagotovilo, da med polnjenjem, popravilom ali ciscenjem ni
nobene nevarnosti izpostavljenosti elektricnih komponent ali el. napeljave. *
Oprema mora stalno biti pravilno ozemljena.
-26-
Vzdrzevanje
Preverjanje kabla
Preverite ali so na elektricnem kablu prisotne sledi obrabe, korozije,
prenapetosti, vibracij, preverite da v delovnim okolju niso prisotni ostri
robovi in druge nevarnosti. Med preverjanjem je treba upostevati staranje in
vpliv stalnih vibracij na kabel.
Preverjanje uhajanja hladilnega sredstva R32
Opomba: preverite uhajanje hladilnega sredstva v okolju, kjer ni potencialnih
virov vziga. Ni potrebna uporaba halogene sonde (ali kateregakoli drugega
detektorja, ki uporablja plamen). Nacini zaznavanja uhajanja: Za hladilno
sredstvo R32 obstajajo instrumenti za zaznavanje, vendar se zaznavanje ne sme
izvajati v okolju s hladilnim sredstvom. Pazite da oprema za zaznavanje ne
postane vir vziga in da se uporablja samo na izmerjeni kolicini hladilnega
sredstva. Detektor uhajanja mora biti nastavljen na minimalno koncentracijo
vnetljivega hladilnega sredstva (v odstotkih). Kalibrirajte in prilagodite
pravilno koncentracijo plina (ne vec od 25%) za uporabo s hladilnim sredstvom.
Ne uporabljajte kloridne raztopine, da ne bi prislo do reakcije klora in
hladilnega sredstva ter korozije bakrenih cevi. V kolikor sumite na uhajanje,
takoj odstranite vse vire ognja iz delovnega obmocja. Ce je mesto uhajanja
potrebno zavariti, je potrebno izolirati vsa hladilna sredstva z mesta
uhajanja (z zapornim ventilom). Pred in po varjenju, uporabljajte OFN za
ciscenje celega sistema.
Odstranjevanje in vakuumiranje
1. Bodite pozorni, da v blizini vakumske crpalke ni virov ognja in da je
prostor dobro prezracen.
2. Vzdrzevalni in drugi posegi na tokokrogu hladilnega sredstva se morajo
izvajati v skladu s splosnim postopkom, vendar glede na vnetljivost, so
naslednji koraki kljucni:
Odstranitev hladilnega sredstva. Ciscenje cevi z inertnimi plini. Evakuacija. Ponovno dekontaminiranje z inertnimi plini. *Rezanje ali varjenje cevi. 3. Hladilno sredstvo je potrebno spraviti v ustrezen skladiscni rezervoar. Tokokrog je potrebno ocistiti z dusikom brez kisika, ter ponoviti postopek nekajkrat. Postopek se ne sme izvajati z zrakom ali kisikom pod tlakom.
-27-
Vzdrzevanje
3. S postopkom ciscenja v sistem prihaja anaerobni dusik in dosega delovni
tlak pod vakumskim stanjem, nato pa se dusik brez kisika sprosca v atmosfero,
da bi se sistem na koncu vakumiral. Ponavljajte postopek dokler se hladilno
sredstvo popolnoma ne ocisti. Po zadnjem polnjenju z dusikom, se plin izpusca
v atmosfero in sele nato lahko pristopite varjenju cevi.
Proces polnjenja s hladilnim sredstvom
Ob splosnem postopku je nujno upostevati naslednje zahteve: Pazite da ne pride
do kontaminacije med razlicnimi hladilnimi sredstvi. Cev za polnjenje
hladilnega sredstva mora biti cim krajsa, da bi bilo cim manj ostankov
hladilnega sredstva. Rezervoarji za skladiscenje morajo stati navpicno. Pazite
da so ukrepi za ozemljitev ustrezni preden zacnete polniti hladilno sredstvo.
Po koncanem polnjenju (ali dokler se ni gotovo) oznacite sistem. Pazite da ne
prenapolnite hladilno sredstvo.
Odlaganje
Odlaganje in recikliranje
Pred tem postopkom mora tehnicno osebje poznati opremo in njene
karakteristike, z ustreznim usposabljanjem. Za recikliranje hladilnega
sredstva, pred samim postopkom
morajo biti analizirani vzorci hladilnega sredstva. Ustrezno se pripravite na
testiranje
vzorcev.
1. Preucite opremo in postopek. 2. Izkljucite el. napajanje 3. Pred postopkom
se prepricajte da: V kolikor je potrebno, z mehansko opremo olajsate delo
rezervoarja za hladilno sredstvo
Imate ustrezno zascitno opremo in jo pravilno uporabljate. *Se postopek izvaja pod nadzorom ustrezno kvalificiranega osebja.
- Da se postopek izvaja v skladu z nacionalnimi standardi.
4. Ce je le mozno, je treba sistem vakumirati. 5. Ce stanje vakuma ni mozno doseci, odtranite hladilno sredstvo v vsakem delu sistema z vecih tock. 6. Pred pricetkom, se prepricajte da je zmogljivost rezervoarja dovoljsnja. 7. Zazenite in upravljajte opremo za odstranjevanje hladilnega sredstva v skladu s
proizvajalcevimi navodili.
-28-
Vzdrzevanje
8. Ne polnite rezervoarja do polne zmogljivosti (prostornina vnesene tekocine
ne sme biti vecja od 80% skupne prostornine).
9. Tudi ce gre za kratko obdobje, ne smete iti cez najvecji tovoljeni tlak
rezervoarja. 10. Po koncu polnjenja rezervorja moraj vsi ventili biti zaprti.
11. Odstranjena hladilna sredstva se ne smejo vnasati v druge sisteme pred
preciscevanjem
in testiranjem. Opomba: Po odstranjevanju naprave in eliminaciji hladilnega
sredstva je potrebno opraviti identifikacijo, ki vsebuje datum in odobritev.
Pazite, da so v identifikaciji navedena vnetljiva sredstva naprave.
Odstranjevanje hladilnega sredstva: 1. Pri remontu ali odlaganju klimatske
naprave je potrebno opravite ciscenje hladilnega
sredstva, najbolje popolno ciscenje. 2. Potrebno je uporabljati posebe
rezervoar za skladiscenje hladilnega sredstva. Pazite da
zmogljivost rezervoarja ustreza kolicini hladilnega sredstva. Rezervoar mora
biti opremljen z ventilom za oddusek in globusnimi ventili, ki morajo biti v
dobrem stanju. V kolikor je mogoce moraj prazni rezervoarji izpraznjeni in se
shranjevati na sobni temperaturi pred uporabo. 3. Opremo za odstranjevanje je
potrebno ustrezno vzdrzevati v dobrem stanju in vedno imeti pri roku navodila.
Oprema mora biti primerna za odstranjevanje R32 hladilnega sredstva. Poleg
tega mora biti prisoten tudi ustrezen aparat za merjenje teze, ki se lahko
uporablja. Cev mora biti povezana z odklopnim spojem, ne sme biti uhajanja.
Pred uporabo opreme za recikliranje, preverite ali je v dobrem stanju.
Preverite ali so elektricne komponente zaprte, da ne bi prislo do uhajanja
hladilnega sredstva in pozara. Ce imate dvome, se obrnite na proizvajalca. 4.
Odstranjeno hladilno sredstvo se utovarja v posebne rezervoarje in posilja
proizvajalcu ob upostevanju ustreznih navodil glede prevoza. Ne tresite
hladilnega sredstva v nobeni posodi. 5. R32 se lahko prevaza odprto. V primeru
transporta, so obvezni ustrezni varnostni antistaticni ukrepi. Med prevozom,
vtovorom in iztovorom je potrebno prav tako upostevati varnostne ukrepe, da ne
bi prislo do poskodb naprave. 6. Kadar odstranjujete kompresor ali cistite
olje kompresorja, pazite da je kompreso napumpan do ustreznega tlaka, da bi
bili prepricani da ni ostankov R32 v lubrikantu. Vakumiranje je potrebno
opraviti preden vrnete kompresor dobavitelju. Upostevajte varnostne ukrepe pri
praznitvi olja iz sistema.
-29-
Korisnicke upute
Zidni split sustav klima ureaj Za model
IFG09-AACT IFG12-AACT IFG18-AACT IFG24-AACT IFX09-SCCT IFX12-SCCT IFX18-SCCT
IFX24-SCCT
Molimo da prije rukovanja ureajem pazljivo i detaljno procitate ove upute!
Sacuvajte ove upute za buduu uporabu.
SADRZAJ
Uporaba i odrzavanje
Upozorenje
1
Bezbjednosne informacije
2
Napomene za uporabu
7
Nazivi dijelova ureaja
9
Cisenje i odrzavanje
10
Rijesavanje problema
12
Postavljanje i servisiranje
Napomene za postavljanje
14
Postavljanje unutarnje jedinice
18
Postavljanje vanjske jedinice
21
Provjera nakon postavljanja i test funkcioniranja
24
Odrzavanje
25
Napomena: Sve slike u ovim uputama su samo sematski prikazi, stvarni izgled ureaja moze se razlikovati.
Upozorenje
Upozorenje: Ovaj klima ureaj koristi R 32 zapaljivo rashladno sredstvo.
Napomene: Ukoliko se klima ureaj sa R32 rashladnim sredstvom lose tretira,
moze izazvati ozbiljna osteenja po ljude i okolis.
- Prostor za ugradnju, uporabu, popravku i skladiranje ovog klima ureaja treba biti vei od 5m! Klima ureaj ne smijete puniti sa vise od 1,7kg rashladnog sredstva. Ne koristite ubrzane metode za odleivanje ili cisenje zaleenih dijelova, osim ukoliko tako ne preporuca proizvoac. Nemojte busiti ili paliti klima ureaj i provjerite da li je osteena pumpa za rashladno sredstvo. Klima ureaj treba da se nalazi u prostoriji bez trajnog izvora vatre, kao sto su otvoreni plamen, plinski ureaji, elektricna grijna tela i slicno. Imajte u vidu da je rashladno sredstvo bez okusa. Klima ureaj treba da se nalazi na mjestu gdje nisu mogua slucajna mehanicka osteenja. Odrzavanje i popravka klima ureaja koji koristi R32 rashladno sredstvo moraju se izvoditi tek nakon obavljenih sigurnosnih provjera radi smanjenja rizika od nesree. Klima ureaj mora biti instaliran sa poklopljenim zaustavnim ventilom. * Pazljivo procitajte upute prije ugradnje, uporabe i odrzavanja.
Simbol
Napomena
Objasnjenje
UPOZORENJE
Simbol pokazuje da ureaj koristi zapaljivo rashladno sredstvo. Ako sredstvo curi i izlozeno je eksternom izvoru paljenja, postoji rizik od pozara.
POZOR
Simbol pokazuje da treba pazljivo procitati upute za uporabu.
POZOR POZOR
Simbol pokazuje da servisno osoblje treba da upravlja opremom, pridrzavajui se
uputa.
Simbol pokazuje da su informacije poput uputa za uporabu ili instalaciju
dostupne.
– 1 –
Bezbjednosne informacije
Nepravilno postavljanje ili uporaba uslijed nepostovanja datih uputa moze da
izazove ozljede ili stetu osobama, imovini, itd.
Stepen ozbiljnosti klasificiran je na sljedei nacin:
UPOZORENJE
Ovaj simbol oznacava mogunost smrtnog ishoda ili ozbiljne ozljede.
POZOR
Ovaj simbol oznacava mogunost ozljede ili osteenja imovine.
UPOZORENJE
Ovim ureajem mogu upravljati djeca iznad 8 godina i osobe sa smanjenim
fizickim, senzornim ili mentalnim sposobnostima, ili sa nedostatkom iskustva i
znanja ukoliko su pod nadzorom ili su im date upute za rukovanje ureajem na
bezbjedan nacin i ukoliko razumiju opasnost do koje moze doi. Djeca se ne
smiju igrati sa ureajem. Cisenje i odrzavanje ureaja ne treba povjeriti djeci
bez nadzora. (Samo za klima ureaje sa oznakom CE)
Ovaj ureaj nije namijenjen za uporabu od strane osoba (ukljucujui djecu) sa
smanjenim fizickim, senzornim ili mentalnim sposobnostima, ili nedostatkom
iskustva i znanja, osim ukoliko su pod nadzorom ili su im date upute od osobe
odgovorne za njihovu bezbjednost. Djecu treba nadzirati kako biste se uvjerili
da se ne igraju s ureajem. (Osim kod klima ureaja sa oznakom CE)
-2-
Bezbjednosne informacije
Klima ureaj mora biti uzemljen. Nepotpuno uzemljenje ureaja moze dovesti do strujnog udara.
Izvucite utikac (ili
Vodite racuna da se
iskljucite osigurac) daljinski i unutarnja
ukoliko ureaj neete jedinica ne nakvase
koristiti duze vrijeme previse niti da budu
kako biste osigurali dugo vlazni.
bezbjednost.
Ne povezujte uzemljenje na uzemljenje plinovoda, vodovoda, gromobrana ili telefona.
Ukoliko je napojni Ne izvlacite utikac
kabel osteen, mora tjekom rada ureaja
biti zamijenjen od
mokrim rukama.
strane proizvoaca ili
ovlastenog servisera
ili kvalificiranog lica.
U suprotnom, moze doi do kratkog spoja.
Nemojte dijeliti uticnicu sa drugim elektricnim ureajima.
To moze prouzrokovati strujni udar.
Prije cisenja i odrzavanja ureaja uvijek iskljucite ureaj i napajanje.
Ne vucite kabel prilikom iskljucivanja iz uticnice.
U suprotnom, moze doi do strujnog udara, pa cak i pozara i eksplozije.
Cijevi prikljucene na ureaj nemaju izvor paljenja.
U suprotnom, moze doi do strujnog udara ili osteenja.
Steta nastala povlacenjem kabla moze prouzrokovati strujni udar.
-3-
Bezbjednosne informacije
Nemojte postavljati Nemojte koristiti
ureaj na mjestu blizu tekuine ili korozivno
zapaljivog plina ili sredstvo za cisenje
tekuina. Rastojanje klima ureaja niti
meu njima mora biti posipati vodom ili
vise od 1m.
drugom tekuinom.
Nemojte pokusavati da sami popravljate klima ureaj.
To moze dovesti do pozara, pa cak i eksplozije.
Ovo moze dovesti do strujnog udara ili osteenja ureaja.
Nepravilna popravka moze uzrokovati pozar ili eksploziju. Kontaktirajte ovlastenog servisera za sve vrste popravki.
Nemojte koristiti klima ureaj po olujnom vremenu.
Ne stavljajte ruke ili bilo koji drugi predmet u odvodna i dovodna crijeva.
Molimo provjerite da li je montirano postolje za vanjsku jedinicu dovoljno cvrsto ili ne.
Prekidac treba da bude iskljucen kako bi se sprijecila pojava osteenja.
Ovo moze dovesti do ozljede osobe ili osteenja ureaja.
Ukoliko je osteeno, moze dovesti do pada jedinice i uzrokovati ozljedu.
Nemojte stavljati pre- Nemojte dozvoliti da
preke u blizini dovoda klima ureaj duva u
i odvoda zraka.
pravcu grijnog tijela.
Ureaj mora biti instaliran u skladu sa zakonskim propisima za povezivanje strujnog kola.
U suprotnom, kapacitet hlaenja ili grijanja e oslabiti, cak moze dovesti i do prestanka rada ureaja.
U suprotnom, to moze dovesti do nepotpunog sagorijevanja, uzrokujui mogue trovanje.
Osigurac za potrosnju struje mora biti postavljen kako bi se sprijecio mogui strujni udar.
-4-
Bezbjednosne informacije
Ovaj proizvod sadrzi fluorovane plinove s efektom staklene baste.
Curenje rashladnog sredstva doprinosi klimatskim promjenama. Rashladno
sredstvo sa nizim stupnjem grijne snage (GWP) manje doprinosi globalnom
zagrijevanju nego sredstvo sa visim stepenom grijne snage, ukoliko se otpusti
u atmosferu. Ovaj ureaj sadrzi rashladno sredstvo sa snagom GPW [675]. To
znaci da ako 1 kg ovog rashladnog sredstva treba da se otpusti u atmosferu,
utjecaj na globalno zagrijevanje e biti [675] puta vei od oslobaanja 1 kg CO2
, za period od 100 godina. Nikada ne pokusavajte da sami dirate rashladno kolo
ili rastavljate ureaj i uvijek trazite pomo kvalificiranog servisera.
Vodite racuna da ispod unutarnje jedinice ne budu slj. predmeti: 1.
Mikrovalna, penica i drugi vrui predmeti. 2. Racunala i drugi visoko
elektrostaticki ureaji. 3. Uticnice koje cesto koristite. Spojne cijevi izmeu
unutarnje i vanjske jedinice se ne pomijeraju, osim ako ne puknu.
Specifikacije osiguraca su odstampane na ploci, kao 3.15A/250V AC, itd.
Upozorenje WEEE
Znacenje precrtanog kontejnera za smee: Ne odlazite elektricne ureaje kao
nesortirani otpad, koristite odvojene prostorije za sakupljanje. Kontaktirajte
Vasu lokalnu upravu kako biste dobili informacije u vezi sa raspolozivim
sustavima za sakupljanje otpada. Ukoliko se elektricni otpad odlozi na
deponiju ili smetlista, opasne materije mogu da procure u podzemne vode, uu u
lanac ishrane, skodei zdravlju i blagostanju. Prilikom zamjene starih ureaja
novim, prodavac je zakonski obavezan da preuzme stari ureaj i odlozi ga bez
novcane naknade.
-5-
Bezbjednosne informacije
Nemojte dugo drzati otvorene prozore i vrata dok je klima ureaj ukljucen.
OPREZ
Nemojte stajati na spoljnoj jedinici niti stavljati teske stvari na nju.
Nemojte koristiti klima ureaj za druge svrhe, kao sto je susenje rublja, cuvanje hrane itd.
U suprotnom kapacitet hlaenja ili grijanja e biti oslabljen.
Ovo moze prouzrokovati ozljedu osobe ili dovesti do osteenja ureaja.
Nemojte
izlagati Podesite
tijelo hladnom zraku odgovarajuu
na duzi period.
temperaturu.
Preporucuje se da razlika izmeu unutarnje i vanjske tem perature ne bude prevelika.
To e pogorsati fizicke uvjete i uzrokovati zdravstvene probleme.
Odgovarajue korekcije podesavanja temperature mogu sprijeciti rasipanje elektricne energije.
Ukoliko Vas klima ureaj nije opremljen kablom i utikacem, jednopolni prekidac mora biti postavljen u fiksnu instalaciju i razdaljina izmeu kontakata ne smije biti manja od 3.0 mm.
Ukoliko je Vas ureaj trajno povezan na zicnu konstrukciju, (RCD) ureaj za diferencijaciju struje koji ne prelazi 30 mA treba da se postavi.
Strujno napojno kolo treba da ima zastitnik za curenje i prekidac ciji kapacitet treba da bude 1.5 puta vei od maksimalne struje.
Sto se tice postavljanja klima ureaja, konsultujte odjeljke ispod u ovim uputama.
Napomene za uporabu
Uvjeti u kojima jedinica ne moze normalno da radi
U temperaturnom opsegu prikazanom u sljedeoj tabeli, klima ureaj moze prestati
s radom i mogu se pojaviti druge nepravilnosti.
Hlaenje
Vanjska Unutarnja
49° C < 16° C
Grijanje
Vanjska Unutarnja
< -15° C > 30° C
- Kada je temperatura previsoka, moze se aktivirati ureaj za automatsku zastitu, tako da e se klima ureaj ugasiti. Kada je temperatura preniska, ureaj za razmjenu topline klima ureaja se moze zamrznuti, sto moze dovesti do curenja vode ili drugih nepravilnosti u radu. U toku dugog hlaenja i isusivanja relativne vlaznosti preko 80% (vrata i prozori su otvoreni), moze se javiti kondenzacija vode ili doi do kapanja vode blizu odvoda zraka.
- Klimatski razred je T1 i odnosi se na standard ISO 5151.
Napomene za grijanje
- Ventilator unutarnje jedinice nee odmah poceti s radom nakon pocetka grijanja kako bi se izbjeglo izduvavanje hladnog zraka.
- Kada je napolju hladno i vlazno, kod vanjske jedinice moze doi do stvaranja mraza iznad ureaja za razmjenu topline sto e ugroziti kapacitet grijanja. Kada klima ureaj zapocne sa radom, doi e do otapanja.
- Tjekom otapanja, klima ureaj e prestati s grijanjem u periodu od oko 5-12 minuta. Tjekom otapanja mogue je isparavanje iz vanjske jedinice. Ovo nije nepravilnost,
ve rezultat brzog otapanja. Grijanje e se nastaviti kada je otapanje u potpunosti gotovo.
Napomene za iskljucivanje
- Kada je klima ureaj iskljucen, glavni kontroler e automatski odluciti da li da odmah stane s radom ili e raditi jos desetak sekundi sa smanjenom frekvencijom i brzinom izduvavanja zraka.
-7-
Napomene za uporabu
Rad u vanrednim slucajevima
- Ukoliko je daljinski upravljac izgubljen ili polomljen, koristite gumb za forsirani rad klima ureaja.
- Ukoliko ovaj gumb pritisnete kada je ureaj ugasen, klima ureaj e poceti s radom u automatskom nacinu rada.
- Ukoliko ovaj gumb pritisnete kada je ureaj ukljucen, klima ureaj e prestati sa radom.
Podesavanje smjera duvanja zraka
1. Koristite tipke krilca gore-dolje i lijevo-desno na daljinskom upravljacu kako biste podesili smjer duvanja zrakaa. Za detalje pogledajte upute o koristenju daljinskog upravljaca.
2. Za modele bez mogunosti duvanja krilaca lijevo-desno, rebra treba da se pomijeraju rucno.
Napomena: Pomjerajte krilca prije nego sto ureaj pocne s radom, jer moze doi do ozljede Vasih prstiju. Nikada nemojte stavljati ruke u dovod ili odvod zraka tjekom rada klima ureaja.
Gumb za forsirani rad
Poseban oprez
1. Otvorite prednji poklopac unutarnje jedinice. 2. Konektor ne dodiruje
prikljucnu plocu i
pozicioniran je kao na slici.
Konektor
Kabel l Kabel 2 Ploca sa prikljuccima
– 8 –
Resetka za dovod zraka Panel
Zracni filter
Ventilaciona resetka
Ventilacioni otvor
Nazivi dijelova klima ureaja
Unutarnja jedinica
Dovod zraka
Gumb za forsirani rad
Odvod zraka
Zastitni prsten za crijevo
Daljinski upravljac
Vanjska jedinica
Kabel za napajanje
Resetka za odvod zraka
Crijevo za povezivanje Crijevo za odvod
Odvod zraka
Napomena: Na svim slikama u ovim uputama dat je samo shematski prikaz. Stvarni
izgled ureaja moze se razlikovati. Utikac, Wi Fi funkcija, Funkcija negativnih
iona, Funkcije okomitog i horizontalnog pomijeranja su opcione, zavisno od
konkretne jedinice.
-9-
Cisenje i odrzavanje
Upozorenje
· Prije cisenja, klima ureaja mora biti ugasen i iskljucen iz zida vise od 5
minuta, u suprotnom postoji rizik od strujnog udara.
· Nemojte kvasiti klima ureaj, jer to moze prouzrokovati strujni udar.
Postarajte se da ni u kom slucaju ne ispirate klima ureaj vodom.
· Isparljive tekuine, kao sto su na primjer razrjeivac ili benzin, mogu
ostetiti kuiste klima ureaja, zato Vas molimo da kuiste cistite iskljucivo
mekom suhom krpom i vlaznom krpom natopljenom neutralnim deterdzentom.
· Tjekom uporabe, vodite racuna o redovitom cisenju filtera, kako biste
sprijecili gomilanje prasine koja moze smanjiti efekte rada ureaja. Ukoliko je
u okruzenju ureaja dosta prasine, to e poveati broj neophodnih cisenja ureaja.
Nakon uklanjanja filtera, ne dodirujte fini dio unutarnje jedinice prstom, jer
ga mozete izgrebati.
Cisenje panela
Kada je panel (poklopac) unutarnje jedinice zaprljan, ocistite ga njezno mekom
krpom koristei toplu vodu ispod 40°C i nemojte pomijerati panel tjekom
cisenja.
Cisenje zracnog filtera
Uklonite zracni filter
1. Koristite obje ruke da biste otvorili panel drzei u kutvima na oba kraja
panela u smjeru strelice.
2. Izvucite zracni filter iz ljezista i uklonite ga.
Cisenje zracnog filtera Upotrebite usisivac ili vodom isperite filter, a
ukoliko je filter jako zaprljan (na primjer masnoom), cistite ga toplom vodom
(ispod 45°C) sa rastvorenim blagim deterdzentom i ostavite filter da se u
hladu osusi napolju.
-10-
Cisenje i odrzavanje
Montirajte filter 1. Postavite osuseni filter u suprotnom smjeru od
uklanjanja, zatim poklopite i zakljucajte
plocu.
Proverite prije uporabe
1. Provjerite da li su otvori za dovod i odvod zraka odblokirani na
jedinicama. 2. Provjerite da li dolazi do blokiranja vode u odvodnom crijevu,
i odmah ocistite ukoliko ga ima. 3. Provjerite da li je dobro uzemljenje. 4.
Provjerite da li su baterije postavljene u daljinskom upravljacu, i da li
imaju dovoljno
snage. 5. Provjerite da nije doslo do osteenja drzaca za montiranje vanjske
jedinice i,
ukoliko jeste, molimo pozovite ovlasteni servis.
Odrzavanje nakon uporabe
1. Iskljucite naponski kabel iz klima ureaja, iskljucite prekidac i izvadite
baterije iz daljinskog upravljaca. 2. Ocistite filter i tijelo jedinica. 3.
Uklonite prasinu i prljavstinu iz vanjske jedinice. 4. Provjerite da nije
doslo do osteenja drzaca za montiranje vanjske jedinice I,
ukoliko jeste, molimo pozovite ovlasteni servis.
-11 –
Rjesavanje problema
Pozor
*Nemojte sami popravljati ureaj, jer lose odrzavanje moze dovesti do strujnog udara ili pozara. Molimo da kontaktirate ovlasteni servisni centar i prepustite profesionalnom serviseru da vodi brigu o odrzavanju Vaseg klima ureaja, a provjera sljedeih stavki prije nego sto pozovete odrzavanje moze ustedeti Vase vrijeme i novac.
Problem
Klima ureaj ne radi.
Unutarnja jedinica ne radi odmah nakon sto je klima ureaj restartiran.
Mogue rjesenje · Mozda je doslo do prekida struje. Sacekajte dok se napajanje
ne vrati. · Mozda se utikac izvukao iz uticnice.
Cvrsto stavite utikac u uticnicu. · Mozda je doslo do ispada osiguraca.
Zamijenite osigurac. · Jos nije doslo vrijeme podesenog tajmera.
Sacekajte ili ponistite podesavanje tajmera. · Ukoliko je klima ureaj ukljucen
odmah nakon sto je
iskljucen, u cilju zastite odlozie se pocetak rada za 3-5 minute.
Klima ureaj prestaje sa radom, a nakon nekog vremena opet pocinje.
Dolazi do duvanja, ali efekat hlaenja/grijanja nije dobar.
· Mozda je dostignuta podesena temperatura. To je normalna pojava.
· Mozda je u rezimu odmrzavanja. Nakon odmrzavanja pocee automatski sa radom.
· Podesen je tajmer iskljucivanja.
Ukljucite ureaj ponovo ukoliko zelite da nastavi sa radom.
· Preterana akumulacija prasine na filter blokira ulaz i izlaz zraka, kut na
resetkama za ispust zraka je previse mali, sto ima utjecaj na efekat grijanja
i hlaenja.
Ocistite filter, uklonite prepreke za ulaz i izlaz zraka i regulirajte kut na
resetkama za ispust zraka. · Slab efekat hlaenja i grijanja moze biti uslijed
otvaranja prozora i vrata i nezatvorenog izduvnog venilatora. Zatvorite vrata,
prozore, izduvni ventilator i slicno. · Funkcija pomonog grijanja nije
ukljucena. Ukljucite funkciju pomonog grijanja. (samo sa modelom sa funkcijom
pomonog grijanja) · Podesen je pogresan nacin rada i temperatura i brzina
duvanja nisu odgovarajui. Izaberite ponovo nacin rada i podesite odgovarajuu
temperaturu i brzinu duvanja.
Unutarnja
jedinica izduvava neprijatan miris.
· Klima ureaj sam po sebi nema neprijatan miris. Ukoliko se on pojavi, mogua
je akumulacija mirisa iz okolisa.
Ocistite filter ili aktivirajte funkciju cisenja.
Rjesavanje problema
Cuje se zvuk tekue vode tjekom rada klima ureaja. Lagani “klik” zvuk se cuje
prilikom paljenja ili gasenja ureaja.
Unutarnja jedinica proizvodi cudan zvuk.
Kapi vode na povrsini unutarnje jedinice.
· Kada se klima ureaj pokrene ili zaustavi, ili se kompresor pokrene ili
zaustavlja tjekom rada, ponekad se cuje zvuk sistanja vode.
Ovo je zvuk protoka rashladnog sredstva i nije okvara.
· Uslijed temperaturnih promjena, radna ploca i ostali dijelovi e dostii
odreenu temperaturu, uzrokujui zvuk trenja. Ovo je normalno, nije problem.
r
· Zvuk ventilatora ili kompresora pokazuje ukljucivanje ili iskljucivanje. ·
Kada odmrzavanje pocinje ili prestaje da radi, cuje se zvuk. Uzrok je protok
rashladnog sredstva u obrnutom pravcu. Ovo nisu kvarovi. · Prevelika
akumulacija prasine na zracnom filteru unutarnje jedinice moze dovesti do
fluktuacije zvuka.
Ocistite povremeno zracne filtere. · Prevelika buka kada je ukljucen nacin
“Intenzivno
izduvavanje”. Ovo je normalno, ukoliko vam je zvuk neprijatan iskljucite
funkciju “Intenzivnog izduvavanja”.
· Kada je velika vlaznost vazduha dolazi do akumuliranja kapljica vode oko
izlaza za zrak, na poklopcu i slicno.
Ovo je normalna pojava. · Produzeno hlaenje na otvorenom prostoru stvara kapi
vode. Zatvorite vrata i prozore. · Previse mali kut otvaranja lopatica takoe
moze rezultirati kapljicama vode na dovodu zraka.
poveajte kut na resetkama za ispust zraka.
Ponekad tjekom
hlaenja unutarnja jedinica izduvava maglu.
· To se desava ponekad kada su unutarnja temperatura i vlaznost zraka visoki.
Razlog je brzo hlaenje unutarnjeg zraka. Nakon sto klima ureaj radi neko
vrijeme, temperatura i vlaznost se smanjuju i magla nestaje.
Odmah zaustavite sve operacije i iskljucite dovod struje i pozovite ovlasteni
servisni centar u sljedeim situacijama.
Cuje se prodoran zvuk ili se emitira neprijatan miris tjekom rada ureaja.
Napojni kabel i utikac su izuzetno topli. Slucajno je ureaj ili daljinski
upravljac napunjen necistoom ili vodom. Prekidac za zrak ili zastitni prekidac
se cesto lomi.
-13-
Napomene za postavljanje
Vazne napomene Prije ugradnje, molimo kontaktirajte lokalni ovlasteni centar
za
odrzavanje. Ako jedinicu ne instalira ovlasteni centar za odrzavanje,
neispravnosti mozda nee biti resene. Ureaj mora da bude instaliran od strane
ovlastenog servisa, u skladu sa drzavnim propisima i ovim uputama. Nakon
ugradnje mora se ispitati curenje rashladnog sredstva. Ukoliko zelite da
promijenite mjesto ugradnje ureaja, pozovite ovlasteni servis.
Provjera raspakiranja
Otvorite kutiju i provjerite klima ureaj na mjestu sa dobrom ventilacijom
(otvorite vrata i prozor) i bez izvora paljenja. Napomena: Operateri moraju da
nose antistaticke ureaje.
Strucna lica moraju da provjere da li postoji curenje rashladnog sredstva
prije otvaranja kutije sa vanjskom jedinicom; obustavite montiranje ukoliko se
otkrije curenje.
Oprema za sprijecavanje pozara je pripremljena i preduzete su antistaticke
mjere predostroznosti prije provjere.Provjerite cijev za rashladno sredstvo
kako biste vidjeli da li ima osteenja.
Bezbjednosna pravila za ugradnju klima ureaja Ureaj za sprijecavanje pozara
mora biti pripremljen prije ugradnje Ugradnja se vrsi na prostoru sa
ventilacijom (otvorite vrata i prozore). Izvori paljenja, pusenje i
telefoniranje nisu dozvoljeni u podrucju
gdje se nalazi R32 rashladno sredstvo. Antistaticke mjere predostroznosti su
neophodne prilikom instalacije
klima ureaja, na primjer odjea i rukavice od cistog pamuka. Drzite detektor
curenja u radnom stanju tjekom instalacije. Ako tjekom instalacije doe do
curenja R32 rashladnog sredstva,
odmah utvrdite njegovu koncentraciju u zatvorenom okruzenju dok dostize
sigurnu razinu. Ako curenje rashladnog sredstva utjece na rad klima ureaja,
odmah prekinite rad ureaja. Klima ureaj mora prvo da se usisa, a zatim odmah
odnese u centar za odrzavanje. Drzite elektricne ureaje, prekidac za
napajanje, uticnice, izvore topline visoke temperature i statike udaljene od
donjih rubova unutrasnje jedinice. Klima ureaj e biti instaliran na
pristupacnom mjestu za ugradnju i odrzavanje, bez prepreka koje mogu blokirati
zracne ulaze i izlaze unutarnjih / vanjskih jedinica i bie udalje od izvora
topline, zapaljivih ili eksplozivnih materija.
-14-
Napomene za postavljanje
Kada instalirate ili popravljate klima ureaj i linija za povezivanje nije
dovoljno duga, cijela linija povezivanja zamijenjuje se linijom povezivanja
originalne specifikacije; produzenje nije dozvoljeno.
Koristite nove cijevi za povezivanje, osim ako je uraeno prosiravanje krajeva
cijevi.
Zahtjevi u pogledu mjesta ugradnje · Izbjegavajte mjesta sa zapaljivim ili
eksplozivnim curenjima plinova
ili gdje postoje veoma agresivni plinovi. · Izbjegavajte mjesta sa jakim
elektro-magnetnim poljima. · Izbjegavajte bucna mjesta. · Izbjegavajte teske
prirodne uvjete (na primjer jake grmljavine, jak vetar,
direktnu suncevu svijetlost ili visoke temperature). · Izbjegavajte mjesta
koja su u domasaju djece. · Skratite vezu izmeu unutarnje i vanjske jedinice.
· Izaberite gdje je lako izvesti servis i popravku i gdje je ventilacija
dobra. · Vanjska jedinica ne treba da bude instalirana na nacin koji bi mogao
dovesti do zauzimanja prolaza, stepenista, pozarnih stepenica, staze ili bilo
koje druge javne povrsine. · Vanjska jedinica bi trebalo da bude instalirana
sto dalje od susjedovih vrata i prozora i zelenih povrsina.
Provjera instalacionog okruzenja Provjerite naznacenu tablicu na vanjskoj
jedinici da biste utvrdili da li je rashladno sredstvo R32. Provjerite
velicinu prostorije. Prostor ne smije biti manji od naznacenog prostora (5m2)
u specifikaciji. Vanjska jedinica mora biti postavljena na mjestu sa dobrom
ventilacijom. Provjerite okolinu mjesta instalacije: R32 ne smije biti
instaliran u
prilozenom rezervisanom prostoru zgrade. Kada koristite elektricnu busilicu
kako biste napravili rupe u zidu, prvo
provjerite da li je na tom mjestu ugraen razvod za vodu, struju ili plin.
Zahtjevi za montaznu konstrukciju
· Stalak za montazu mora da ispuni odgovarajue nacionalne ili industrijske
standarde u pogledu jacine tako da varovi i spojevi budu zastieni od hre.
· Stalak za montazu i njegova nosiva povrsina mora biti u stanju da izdrze 4
puta vise od tezine jedinice, ili 200kg.
-15-
Napomene za postavljanje
· Kod montaze nosaca na vanjskoj jedinici e biti pricvrsen zavrtanj za
prosirenje.
· Uvjerite se da ste osigurali sigurnu instalaciju bez obzira na vrstu zida na
kojem je ureaj instaliran, da bi se sprijecilo potencijalno kapanje koje bi
moglo povrijediti ljude. Zahtjevi za zastitu od elektricne energije
· Provjerite da li snaga napona, namijenjeno strujno kolo za napajanje klima
ureaja i prijecnik kabla za napajanje ispunjavaju nacionalne zahtjeve.
· Kada je maksimalna struja klima ureaja >16A, mora se koristiti prekidac
zraka ili ureaj za zastitu od curenja.
· Normalni radni opseg je 90%-110% lokalnog napona. Nedovoljno napajanje moze
rezultirati kvarom, strujnim udarom ili pozarom. U slucaju nestabilnosti
napona, predlaze se poveanje regulatora napona.
· Minimalna udaljenost izmeu klima ureaja i zapaljivih materija je 1.5 m.
· Meuvezni kabel povezuje unutarnju i vanjsku jedinicu. Prije nego sto pocnete
povezivanje, prvo morate izabrati odgovarajuu velicinu kabla.
· Tipovi kablova: Kabel za napajanje: H07RN-F ili H05RN-F; Meuvezni kabel:
H07RN-F or H05RN-F;
· Minimalni poprecni presjek kabla za napajanje i meuveznog kabla.
Severna Amerika Amperaza AWG ureaja (A)
10
18
13
16
18
14
25
12
30
10
40
8
Drugi regioni Nazivna struja (A) Nazivni poprecni
presjek (mm2)
3 i < 6
0.75
6 i <10
1
10 i <16
1.5
16 i <25
2.5
25 i <32
4
32 i <40
6
· Velicina meuveznog kabla, kabla za napajanje, osiguraca i prekidaca je
odreena maksimalnom strujom ureaja. Maksimalna struja je naznacena na plocici
koja se nalazi na bocnoj strani poklopca jedinice. Pogledajte tablicu da biste
izabrali pravi kabel, osigurac ili prekidac.
· Napomena: Osnovna oznaka kabla odnosi se na detaljni dijagram ozicenja i
nalazi se na ureaju koji ste kupili.
-16-
Napomene pri instalaciji
Zahtjevi za rad na visini
· Prilikom postavljanja jedinica na 2m ili vise iznad razine baze, moraju se
nositi sigurnosni pojasevi kao i uzad dovoljno jaka da se bezbjedno pricvrsti
na vanjsku jedinicu, kako bi se sprijecilo padanje koje bi moglo izazvati
tjelesne ozljede ili smrt, kao i materijalnu stetu.
Zahtjevi za uzemljenje
· Klima ureaj spada u I vrstu elektricnih aparata i mora mu se obezbjediti
pouzdano uzemljenje. · Nemojte povezivati uzemljenu zicu na cijevi za plin,
vodovodne cijevi, gromobran, telefonske zice ili slabo uzemljena strujna kola.
· Zica za uzemljenje je specijalno dizajnirana i ne moze se koristiti u druge
svrhe, niti se moze ucvrstiti obicnim vijcima. · Preporuceni precnik meuveznog
kabla je kao u uputama, tipa prikljucka za ,,nulu”, koji ispunjava lokalne
standarde (unutarnji precnik prikljucka za ,,nulu” treba da odgovara velicini
zavrtnja jedinice, ne vise od 4.2mm). Nakon ugradnje provjerite da li su
zavrtnji u dobrom polozaju i da li postoji opasnost od labavljenja.
Ostalo
· Nacin povezivanja klima ureaja i naponskog kabla kao i nacin povezivanja
svakog nezavisnog elementa ima shematski prikaz dodat uz ureaj. · Model i
nazivne vrijednosti osiguraca moraju odgovarati elektricnoj instalaciji i
specifikacijama klima ureaja.
Sadrzaj pakiranja
Sadrzaj pakiranja unutarnje jedinice
Sadrzaj pakiranja vanjske jedinice
Naziv
Kolicina Jed.
Naziv
Kolicina Jed.
Unutarnja jedinica
1
Set
Vanjska jedinica
1
Set
Daljinski upravljac
1
Kom Crijevo za povezivanje 2
Kom.
Baterije (7#)
2
Kom
Plasticna traka
1
Rolna
Upute
1
Set Zast. prsten za crijevo 1
Kom.
Odvodno crijevo
1
Kom Ispuna
1
PAKET
NAPOMENA: Svi dodatni dijelovi su. dio otvorenog konkretnog pakiranja, te ukoliko ima
razlike s Vasim ureajem, molimo za razumijevanje.
-17-
Postavljanje unutarnje jedinice
Prikaz dimenzija za postavljanje unutarnje jedinice
Prostor do plafona
Prostor do zida
20cm sa strane
15 cm iznad
Prostor do zida
20cm sa strane
230-260 cm
Prostor do poda
Montazna ploca
1. Zid na kome ete postaviti unutarnju jedinicu mora biti cvrst, kako bi
sprijecio vibracije.
2. Koristite krizasti tip zavrtnja kako biste nosac pricvrstili horizontalno
za zid i montirali, pazei na bocnu horizontalu i uzduznu vertikalu.
3. Povucite nosac rukom posle postavljanja da se uvjerite da je cvrsto vezan
za zid.
Busenje rupa za cijevi
1. Napravite rupu uz pomo elektricne busilice ili burgijom na unaprijed odreene pozicije, sa spoljnim nagibom 5°-10°.
2. Da biste zastitili cijevi i kablove od osteenja koja prolaze kroz zid, kao i od eventualnih glodara koji se nastanjuju u zidne supljine, zastitni prsten se zalemi i zapecati kitom.
Napomena: Rupe su obicno debljine
Kit
60mm 80mm. Prilikom busenja rupe,
izbjegavajte tvrde zidove i one na kojima
su prethodno ve instalirane cijevi.
-18-
Prsten za zastitu crijeva
Postavljanje unutarnje jedinice
Putanja crijeva
1. U zavisnosti od polozaja jedinice, crijevo moze biti usmjereno bocno sa
lijeve ili desne strane (slika1), ili okomito otpozadi (slika 2) (u zavisnosti
od duzine cijevi unutarnje jedinice). U slucaju bocnog postavljanja, presjei
izlaz na suprotnoj strani.
Sl. 1
Crijevo za povezivanje odvod i kablovi
Outlet material preparation
Sl. 2
Crijevo za povezivanje odvod i kablovi
Povezivanje crijeva
1. Pomerite fiksni dio kako biste izvukli crijevo iz unutarnje jedinice.
Odvrnite rukom sestokutnu maticu lijevo do kraja.
2. Spojite crijevo za povezivanje sa unutarnjom jedinicom: Ciljajte u centar
crijeva, zavijte maticu prstima u desno, a zatim dotegnite kljucem, kao sto je
prikazano na slici. Obrtni momenat zatezanja je prikazan u tabeli.
Napomena: Provjerite pozorno prije instalacije da li na spojnicama postoje
osteenja. Spojne cijevi izmeu unutarnje i spoljne jedinice se ne koriste
ponovo, osim ako se ne uradi prosiravanje krajeva cijevi.
Tabela obrtnog momenta zatezanja
Velicina crijeva (mm)
6/6. 35 9/9. 52 12/12. 7
15. 88 19. 05
Sila zatezanja (N · m)
15–25 35–40
45–60 73–78 75–80
Crijevo unutarnje jedinice
Konusni prsten
Crev o za pov
Kljuc za matice
Obrtni kljuc
Obmotajte crijevo
1. Koristite izolir traku da spojite dijelove unutarnje jedinice i crijeva za
povezivanje, a zatim uz pomo izolacionog materijala obmotajte crijeva
i zatvorite dobro kako bi se sprijecilo stvaranje kondenzata vode na spoju. 2.
Povezite izlaz za vodu sa odvodnom cijevi, i cvrsto i pravo postavite spojena
crijeva i kablove. 3. Koristite plasticne pricvrsivace kako biste obmotali
crijevo za povezivanje, kablove i odvodno crijevo. Pustite da slobodno pada
nadole.
– 19-
Crijevo za povezivanje, odvod i kabel
Plasticni ucvrsivac
Postavljanje unutarnje jedinice
Fiksiranje unutarnje jedinice
1. Okacite unutarnju jedinicu na kacaljke, i pomjerajte ureaj lijevo desno da
se uvjerite da su kuke dobro i cvrsto postavljene.
2. Gurnite ka donjoj lijevoj i gornjoj desnoj strani jedinicu prema
kacaljkama, dok kuka koja je postavljana ne uradi “klik.
Dijagram povezivanja zica
· Ukoliko je uz klima ureaj obezbeen kabel, zicno povezivanje je fabricki
odraeno, tako da nema potrebe za povezivanjem.
· Ukoliko kabel nije obezbeen, potrebno je povezivanje prema shematskom
prikazu.
Nakon instaliranja provjerite da li su: 1.zavrtnji u dobrom polozaju i da li
postoji opasnost od opustanja. 2.konektor displejske ploce stavljen na pravo
mjesto i ne dodirujte plocu. 3.kontrolna kutija dobro zatvorena.
Konstantna brzina
Varijabilna brzina
Konektor
Vanjska jedinica
Vanjska jedinica
Ukoliko postoji konektor, povezite
direktno.
Vanjska jedinica
Vanjska jedinica
NAPOMENA: Ovaj prirucnik obicno ukljucuje nacin povezivanja kablova za
razlicite vrste
klima ureaja. Ne mozemo iskljuciti mogunost da su neki drugi tipovi ureaja
isto prikazani na shemi. Shematski prikaz je samo referenca. Ako je ureaj malo
drugaciji, pogledajte
detaljno shematski prikaz za povezivanje ureaja koji ste kupili.
– 20-
Postavljanje unutarnje jedinice
Prikaz dimenzija za postavljanje vanjske jedinice
Prostor do prepreke
Protok zraka
Prostor do prepreke
Prostor do prepreke
Protok zraka
Left installation feet
Dovod zraka
Right installation feet
Odvod zraka
Postavljanje vijaka vanjske jedinice
Velicina vanjske jedinice W1(W2)HD) (mm) 665(710)x420x280 600(645)x485x260
660(710)x500x240 700(745)x500x255 730(780)x545x285 760(810)x545x285
790(840)x550x290 800(860)x545x315
800(850)x590(690)x310 825(880)x655x310 900(950)x700x350 900(950)x795x330
970(1044)x803x395
A (mm) 430 400 500 460 540 540 545 545 540 540 630 535 675
B (mm) 280 290 260 260
280 280 300 315 325 335 350 350 409
Postavljanje crijeva za povezivanje
Povezite vanjsku jedinicu sa crijevom za povezivanje:
Usmjerite kontra-otvor crijeva za povezivanje na kraj
ventila, i zategnite konus maticu prstima.
Zatim zategnite konus navrtnja uz pomo kljuca. * Kada produzavate cijevi, mora se dodati
Zaustavni
jos ventil
rashladnog sredstva, tako da ne bude doveden u pitanje
rad i ucinak klima ureaja.
Konusni prsten
Duzina creva
s=5M
Kolicina rashl.sredstva koje se dodaje
Nije potrebno
Kolicina rashl. sredstva za jedinicu
5-15M CCs=12000Btu CC3=18000Btu
16g/m 24g/m
s=1kg =S2kg
Napomena: 1. Ova tabela je samo za referencu.
2. Spojne cijevi izmeu unutarnje i vanjske jedinice se ne koriste
ponovo, osim ako se ne uradi prosiravanje krajeva cijevi.
3. Nakon ugradnje provjerite da li je poklopac zaustavnog ventila dobro postavljen
-21-
Cijev za povezivanje Bocna cijev za tekuinu Bocna cijev za plin
Kljuc
Poklopac zaustavnog ventila
Postavljanje vanjske jedinice
Povezivanje zica
1. Olabavite zavrtnje i uklonite poklopce iz jedinice. 2. Povezite kablove sa
odgovarajuim terminalima vanjske jedinice (vidi dijagram povezivanja zica), a
ako postoje signali vezani za utikac, samo ih ujedinite. 3. Uzemljenje zica:
Uklonite vijak za uzemljenje iz elektricne konzole, pokrijte kraj zice za
uzemljenje na vijak i zavrnite ga u uzemljenu rupu. 4. Fiksirajte kabl sa
ucvrsivacem. 5. Vratite poklopac u prvobitni polozaj i pricvrstite ga
zavrtnjima.
E-parts cover
Dijagram povezivanja zica
Konstantna brzina
Varijabilna brzina
Napajanje
Unutrasnja jedinica
Unutrasnja jedinica
Napajanje
Napajanje
Unutrasnja jedinica
Konektor
Unutrasnja jedinica
Napajanje
NAPOMENA:
Ako postoji konektor, povezite direktno.
Ovaj prirucnik obicno ukljucuje nacin povezivanja kablova za razlicite vrste
klima ureaja. Ne mozemo iskljuciti mogunost da su neki drugi tipovi ureaja
isto prikazani na shemi.
Shematski prikaz je samo referenca. Ako je ureaj malo drugaciji, pogledajte
detaljno sematski prikaz za povezivanje ureaja koji ste kupili.
-22-
Postavljanje vanjske jedinice
Vakuumiranje
Za rashladno sredstvo R32 koristi se posebna pumpa za vakuum.
Prije svih radova na klima, skinite poklopac stop ventila (ventili za plin i tekuinu) i budite
sigurni da ste ga pritegli posle (da bi se sprijecilo potencijalno curenje zraka).
1. Da bi se sprijecilo curenje zraka i prosipanje zategnite matice kod svih
cijevi.
2. Povezite ventil, crijevo za punjenje, glavni ventil i vakuum pumpu.
3. Potpuno otvorite rucicu i ostavite pumpu da radi najmanje 15 minuta i
provjerite da li su ocitavanja multimetra -0.1MPa (-76cmHg).
4. Nakon nanosenja vakuuma, otvorite ventil heksagonalnim kljucem.
Vodomer -76cm Hg
Rucica gor.
Crijevo za punjenje
Manom etar Razvodni ventil Rucica do
Crijevo za punjenje
5. Provjerite da li su i otvoreni i zatvoreni
konektori bez curenja.
Vakuum-pumpa
Zaustavni ventil (za tekuine)
Zaustavni ventil
(za plin)
Vanjski odvod kondenzata (samo za toplotne pumpe)
Za vrijeme grijanja, kondenzirana i odleena voda bi trebalo da se odvede crijevom za odvod kondenzata. Postavljanje: Povezite vanjski konektor za odvod kondenzata (otvor 25) na osnovnoj ploci, i crijevo za odvod kondenzata, tako da otpadna voda stvorena u vanjskoj jedinici, moze da se sprovede vani.
-Montazni panel Spoljni odvod
-23-
Provjera nakon postavljanja i test funkcioniranja
Provjera nakon postavljanja
Provjera zastite od elektricne energije 1. Provjeriti da li napon odgovara. 2.
Provjeriti da li postoji bilo kakva neispravna veza ili lose prikljucenje
struje, signala i
uzemIjene zice. 3. Da li su uzemljene zice sigurno i pravilno uzemljene.
Provjera bezbjednosti instalacija 1. Da li je instalacija sigurna. 2. Da li
voda glatko otjece. 3. Da li su zice i kablovi pravilno postavljeni. 4.
Provjeriti da slucajno neki dio nije ostao unutar jedinice. 5. Provjerite da
li je cijevovod rashladnog sredstva dobro zastien. Testiranje curenja
rashladnog sredstva U zavisnosti od nacina instalacije, mogu se primijeniti
sljedei metodi za utvrivanje i provjeru u dijelovima kao sto su 4 konekcije
vanjske jedinice kao i jezgara odvodnih ventila i T-ventila: 1. Metod
mjehuria: Nanesite jednaki sloj spreja ili sapunice na sumnjivo mjesto gdje
bi moglo curiti i pazljivo posmatrajte hoe li doi do mjehuria. 2. Metod
Instrument: Provjeriti curenje dodirujui sondu detektora za curenje u
skladu sa uputama o sumnjivim tockama gdje moze doi do curenja. Napomena:
Prije provjere vodite racuna o dobroj ventilaciji.
Test funkcioniranja
Priprema za test funkcioniranja: Provjerite da li su sve cijevi i kablovi
dobro povezani.
Provjerite da li su ventili na plinskoj i tecnoj strani potpuno otvoreni.
Povezite napojni kabel sa uticnicom. Stavite baterije u daljinski upravljac.
Napomena: Prije testiranja vodite racuna o dobroj ventilaciji. Koraci testa
funkcioniranja 1. Ukljucite klima ureaj i pritisnite gumb ON/OFF na daljinskom
upravljacu da biste pokrenuli ureaj. 2. Izaberite Hlaenje, Grijanje (nije
dostupno kod modela koji su samo za hlaenje), SWING i druge nacine rada uz
pomo daljinskog upravljaca da provjerite da li ureaj radi ispravno.
-24-
Odrzavanje
Oprez: Kontaktirajte ovlastene servisne centre radi odrzavanja ovog ureaja.
Odrzavanje od strane nekvalificirane osobe moze prouzrokovati opasnost.
Napunite klima ureaj R32 rashladnim sredstvom i odrzavajte ureaj strogo u
skladu sa zahtjevima proizvoaca. Poglavlje se uglavnom fokusira na posebne
zahtjeve za odrzavanje ureaja sa R32 rashladnim sredstvom. Zamolite servisera
da procita ove tehnicke upute radi potpunog upoznavanja. .
Neophodne kvalifikacije osoblja za odzavanje klima ureaja
1. Pored uobicajene obuke za popravku i rad sa rashladnim ureajima, za rad na
ureajima sa zapaljivim rashladnim sredstvima neophodna je dodatna obuka. U
mnogim zemljama ovu obuku obavljaju akreditovane nacionalne organizacije i to
u skladu sa standardima kompetentnosti koji su propisani zakonom. Stecena
kompetentnost dokumentuje se certifikatom.
2. Odrzavanje i popravak klima ureaja mora se voditi prema postupku koji
preporucuje proizvoac. Ako su drugi strucnjaci potrebni za pomo pri odrzavanju
i popravci klima ureaja, postupak se mora sprovesti pod nadzorom osoba koje
imaju kvalifikaciju za popravku klima ureaja sa zapaljivim rashladnim
sredstvom.
Provjera mjesta
Prije bilo kakvog odrzavanja ureaja sa R 32 rashladnim sredstvom, moraju se
preuzeti odgovarajue bezbjednosne mjere kako bi se smanjio rizik od opasnosti.
Provjerite da li je mjesto dobro provetreno, kao i ispravnost antistaticke i
protivpozarne opreme. Tjekom odrzavanja sustava za hlaenje pratite sljedee
mjere predostroznosti.
Operativne procedure
1. Podrucje rada: Osoblje koje radi na odrzavanju, kao i ostali koji su
ukljuceni u rad, moraju biti upoznati sa prirodom posla koji obavljaju.
Podrucje radnog prostora treba odvojiti i provjeriti uvjete, odnosno uvjeriti
se da u radnom prostoru nema zapaljivog materijala.
2. Provjera prisustva rashladnog sredstva: Prije i tjekom rada potrebno je
odgovarajuim detektorom rashladnih sredstava prekontrolirati podrucje rada
kako bi tehnicar imao uvid u potencijalno prisustvo toksicnog ili zapaljivog
materijala u zraku. Vodite racuna da oprema za detektiranje curenja rashladnih
sredstava odgovara svim rashladnim sredstvima, odnosno da nema varnicenja, da
je sve dobro zapecaeno i zatvoreno.
3. Prisustvo aparata za gasenje pozara: Ukoliko se izvode bilo kakvi vrui
radovi na opremi za hlaenje ili slicnim dijelovima, neophodno je da vam pri
ruci bude aparat za gasenje pozara. U blizini podrucja rada treba imati suhi
prah ili aparat za gasenje pozara.
-25-
Odrzavanje
4.Bez izvora paljenja: Nijedno lice koje obavlja rad na rashladnom sustavu i
izlozeno je radu sa cijevima ne smije koristiti nikakve izvore paljenja na
nacin koji moze dovesti do eksplozije ili pozara. Svi izvori paljenja,
ukljucujui dim od cigareta moraju biti dovoljno udaljeni od mjesta
instalacije, popravke, pomijeranja ili odlaganja tjekom kojih rashladno
sredstvo moze dospeti u okolni prostor. Prije pocetka rada ispitajte da li
postoje zapaljive opasnosti ili rizik od paljenja. Znak “Zabranjeno pusenje”
treba da bude istaknut.
5. Ventilacija podrucja rada (otvorite vrata i prozore): Vodite racuna da je
podrucje rada otvoreno ili da je adekvatno provjetreno prije otvaranja
rashladnog sistema ili izvoenja vruih radova. Ventilacija podrucja mora da
traje tjekom izvoenja radova. Ventilacijom prostora bezbjedno se u atmosferu
izbacuje bilo koje potencijalno rashladno sredstvo.
6. Provjera rashladne opreme Ukoliko se mijenjaju elektricni dijelovi, oni
moraju biti odgovarajue svrhe i ispravne specifikacije. Moraju se pratiti
upute proizvoaca i servisa. Ukoliko imate bilo kakve nedoumice, konsultirajte
se sa tehnickim sektorom proizvoaca. Za instaliranja tjekom kojih se koriste
zapaljiva rashladna sredstva moraju se obaviti sljedee provjere: · Kolicina
punjenja je u skladu sa velicinom prostorije u kojoj su instalirani dijelovi
sa rashladnim sredstvom. · Ventilacija i uticnice rade adekvatno i neometano.
· Ukoliko se koristi indirektno rashladno kolo, treba provjeriti da li u
sekundarnom kolu ima rashladnog sredstva. · Cijev za hlaenje ili komponente
ugrauju se u polozaj u kome je malo verovatno da e biti izlozene bilo kojoj
supstanci koja moze da dovede do korozije komponenti koje sadrze rashladno
sredstvo, osim ako su komponente sastavljene od materijala koji su inherentno
otporni na koroziju ili su odgovarajue zastieni od korodiranja.
7. Provjera elektricnih ureaja: Popravka i odrzavanje elektricnih komponenti
obuhvata inicijalne bezbjednosne provjere i postupke provjere komponenti. Ako
postoji neka greska koja bi mogla ugroziti sigurnost, onda ne treba povezati
elektricno napajanje sve dok se problem ne rijesi na zadovoljavajui nacin. Ako
greska ne moze odmah da se ispravi, ali je neophodno nastaviti rad,
primjenjuje se adekvatno privremeno rjesenje. Kvar se prijavljuje vlasniku
opreme i sve strane se ukljucuju u savjetovanje. Pocetna kontrola bezbjednosti
treba obuhvatati: · Praznjenje kondenzatora: ovo se radi pazljivo kako bi se
izbjegla opasnost od varnicenja. · Provjera da tjekom punjenja, popravke ili
cisenja sustava ne postoji nikakva izlozenost elektricnim komponentama ili
ozicavanju. · Vodite racuna o stalnom pravilnom uzemljenju.
-26-
Odrzavanje
Provjera kabla
Provjerite kabel od habanja, korozije, prenapona, vibracije, kao i da li ima
ostrih rubova i drugih stetnih efekata u okruzenju. Tjekom provjere treba
uzeti u obzir utjecaj starenja i kontinuiran uticaj vibracije kompresora i
ventilatora na njega.
Provjera curenja rashladnog sredstva R32 Napomena: Provjerite curenje
rashladnog sredstva u okruzenju u kome nema potencijalnog izvora paljenja. Ne
treba koristiti nikakvu halogenu sondu (ili bilo koji drugi detektor koji
koristi otvoreni plamen). Nacini uocavanja curenja: Za sustave koji koriste
rashladno sredstvo R 32 postoji instrument za detekciju curenja, ali detekcija
curenja se ne smije izvoditi u okruzenju sa rashladnim sredstvom. Vodite
racuna da detektor curenja ne postane izvor paljenja i da se primjenjuje samo
na izmjerenoj kolicini rashladnog sredstva. Detektor curenja mora biiti
podesen na minimalnu koncentraciju zapaljivog rashladnog sredstva (u
procentima). Kalibrirajte i prilagodite pravilnu koncentraciju plina (ne vise
od 25%) sa koristenim rashladnim sredstvom. Tekuina koja se koristi u
detekciji curenja primjenjuje se na veinu rashladnih sredstava. Nemojte
koristiti kloridne rastvore kako biste sprijecili reakciju izmeu klora i
rashladnih sredstava i koroziju bakarne cijevi. Ukoliko sumnjate na curenje,
odmah otklonite svaki oblik vatre sa podrucja rada ili ugasite vatru. Ako
mjesto curenja treba da se zavari, treba izolirati sva rashladna sredstva sa
mjesta curenja (pomou prekidnog ventila). Prije i tjekom zavarivanja,
koristite OFN kako biste procistili cijeli sustav.
Uklanjanje i vakuumiranje
1. Vodite racuna da nema izvora paljenja blizu vakuum pumpe i da postoji
dobra ventilacija.
2. Odrzavanje i drugi radovi na rashladnom kolu treba da se izvode u skladu
sa opom procedurom, ali kada se zapaljivost uzme u obzir, sljedee operacije su
kljucne. Molimo vas da pratite sljedee postupke: · Uklanjanje rashladnog
sredstva. · Dekontaminiranje cijevi inertnim plinovima. · Evakuacija. ·
Ponovno dekontaminiranje cijevi inertnim plinovima. · Sjecenje ili zavarivanje
cijevi.
3. Rashladno sredstvo treba vratiti u odgovarajui skladisni rezervoar.
Produvati sustav azotom bez kisika. Ponovite proces nekoliko puta. Ovaj proces
se ne smije izvoditi uporabom kompresovanog zraka ili kisika.
-27-
Odrzavanje
3. Procesom produvavanja u sustav ulazi anaerobni nitrogen i dostize radni
pritisak pod vakuumskim stanjem, a zatim se azot bez kisika emitira u
atmosferu i na kraju vakuumira sustav. Ponavljajte proces dok se sasvim ne
ocisti rashladno sredstvo u sustavu. Nakon posljednjeg punjenja anaerobnim
nitrogenom, plin se ispusta u atmosferu i mozete zavariti sustav. Neophodno je
uraditi ovaj proces da bi se sustav zavario.
Proces punjenja rashladnog sredstva
Uz opi postupak, neophodno je ispuniti i sljedee zahtjeve: – Vodite racuna da
ne postoji kontaminacija izmeu razlicitih rashladnih sredstava kada koristite
ureaj za punjenje rashladnog sredstva. Cijev za punjenje rashladnog sredstva
treba da bude sto kraa, kako bi se smanjili ostaci rashladnog sredstva u njoj.
– Rezervoari za skladiranje treba da stoje okomito. – Vodite racuna da su
mjere uzemljenja ve poduzete prije nego sto se rashladni sustav napuni
rashladnim sredstvom. – Nakon zavrsetka punjenja (ili dok jos nije zavrseno)
markirajte sustav. – Vodite racuna da ne prepunite rashladno sredstvo.
Otpad i oporavak materijala
Otpad: Prije ovog postupka tehnicko osoblje se upoznaje sa opremom i njenim
karakteristikama i pruzena im je preporucena obuka. Za recikliranje rashladnog
sredstva, prije samog rada treba analizirati uzorke rashladnog sredstva.
Adekvatno se pripremite za testiranje uzorka. 1. Upoznajte se sa opremom i
postupkom. 2. Iskljucite elektricno napajanje. 3. Prije postupka vodite racuna
da: · Ukoliko je to neophodno, mehanickom opremom olaksajte rad rezervoara za
hlaenje. · Imate adekvatnu zastitnu opremu i koristite je ispravno. · Postupak
mora da se izvodi po nadzorom kvalificiranog osoblja. · Postupak mora biti u
skladu sa nacionalnim standardima. 4. Ako je mogue, rashladni sustav treba
vakuumirati. 5. Ako je stanje vakuuma nemogue postii, izvadite rashladno
sredstvo u svakom dijelu sustava sa vise mjesta. 6. Prije pocetka oporavka,
treba osigurati da je kapacitet rezervoara dovoljan. 7. Pokrenuti i upravljati
opremom za oporavak u skladu sa uputama proizvoaca.
-28-
Odrzavanje
8. Ne punite rezervoar do punog kapaciteta (zapremina unesene tekuine ne
smije da prelazi 80% ukupne zapremine rezervoara).
9. Cak i da je kratkog trajanja, ne smijete premasivati maksimum radnog
pritiska rezervoara. 10. Nakon zavrsetka punjenja rezervoara i kraja postupka
rada, vodite racuna da se
rezervoari i oprema brzo uklone i da svi ventili budu zatvoreni. 11.
Oporavljena rashladna sredstva ne smiju se ubacivati u druge sustave prije
precisavanja
i testiranja. Napomena: Nakon otpada ureaja i eliminacije rashladnog sredstva
treba uraditi identifikaciju koja sadrzi datum i odobrenje. Vodite racuna da
se u identifikaciji napominju zapaljiva rashladna sredstva ovog ureaja.
Oporavak: 1. Prilikom oporavka ili otpada ureaja treba uraditi cisenje
rashladnog sredstva. Najbolje je
potpuno ukloniti rashladno sredstvo. 2. Kada punite rezervoar za skladiranje
rashladnim sredstvom, moze se koristiti samo
specijalan rezervoar za hlaenje. Vodite racuna da kapacitet rezervoara
odgovara kolicini rashladnog sredstva. Svi rezervoari koji se koriste za
oporavak rashladnih sredstava moraju imati identifikaciju rashladnog sredstva
(Rezervoar za oporavak rashladnog sredstva). Rezervoari za skladiranje moraju
biti opremljeni ventilom za otpustanje pritiska i globusnim ventilima i moraju
biti u dobrom stanju. Ukoliko je to mogue, prazni rezervoari prije uporabe
treba da budu evakuisani i da se drze na sobnoj temperaturi prije uporabe. 3.
Opremu za oporavak treba drzati u dobrom radnom stanju i opremljenu uputstama
za uporabu. Oprema bi trebalo da bude pogodna za oporavak R32 rashladnih
sredstava. Pored toga, treba da postoji i kvalificirani ureaj za mjerenje
tezine koji se moze koristiti. Crijevo treba da bude povezano odvojivim
spojem, ne smije biti curenja i mora se nalaziti u dobom stanju. Prije uporabe
opreme za oporavak, provjerite da li je u dobrom stanju i da li je dobro
odrzavana. Provjerite da li su elektricne komponente zaptivene kako bi se
sprijecilo curenje rashladnog sredstva i pozara. Ako imate bilo kakvo pitanje,
molimo vas da se obratite proizvoacu. 4. Oporavljeno rashladno sredstvo se
utovara u specijalne rezervoare i vraa proizvoacu uz praenje uputa za
transport. Nemojte mukati rashladno sredstvo niti u opremi za oporavak niti u
rezervoaru za skladiranje. 5. R32 se ne moze transportirati otvoreno. U
slucaju transporta preuzmite neophodne anti elektrostaticke mjere. Tjekom
transporta, utovara i istovara moraju se postovati odgovarajue zastitne mjere
da bi se sprijecilo osteenje klima ureaja. 6. Kada uklanjate kompresor ili
cistite ulje kompresora, vodite racuna da je kompresor napumpan do odgovarajue
razine, kako biste bili sigurni da nema ostataka R32 rashladnog sredstva u
lubrikantnom ulju. Vakuumiranje treba uraditi prije nego sto vratite kompresor
dobavljacu. Pridrzavajte se bezbjednosnih mjera prilikom praznjenja ulja iz
sustava.
-29-
www.voxelectronic.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>