environment ES200C Home Ventilation System

Product Information

The Ceiling Mounted Version is a Home Ventilation System designed for residential use. It operates as a Whole House Heat Recovery System, providing continuous ventilation to maintain ideal indoor air quality. The system helps prevent the build-up of moisture, remove steam/condensation and odors during bathing and cooking, and prevent the formation of black mold on walls and behind cupboards. Poor ventilation can cause dampness in cupboards, wardrobes, clothes, and furnishings, which this system aims to address. It operates 24 hours a day at a low rate known as “trickle” to ensure proper ventilation. The system can also be boosted to a higher rate for 20 minutes by pressing the button on the unit. The boost LED will light up to indicate the unit is in boost mode.   For users with the App control version, there is a separate App instruction booklet available that allows for more control over the unit using a smart device. The unit is powered by two AAA  batteries, and the battery replacement process involves unclipping the switch front cover to access the battery located at the back of the cover. Annual running costs information can be obtained by scanning the provided QR code or visiting envirovent.com /annual-running-costs. The unit also features a filter maintenance indicator, which will flash when the filter needs to be checked. Pressing the button for 12 seconds will reset the filter once filter maintenance is complete. A flashing LED indicates a unit fault. For installation problems or further assistance, customers can contact EnviroVent at 01423 810 810.

Product Usage Instructions

  1. To control the system:
    • Press the button once to check the current status of the unit.
    • Press the button again to activate boost mode for 20 minutes. The boost LED will light up during this period.
  2. If the battery needs replacement:
    • Unclip the switch front cover.
    • Locate the battery on the back of the cover.
    • Replace the old batteries with two AAA batteries.
  3. For App control versions:
    • Refer to the separate App instruction booklet for detailed instructions on controlling the unit using a smart device.
  4. For filter maintenance:
    • If the filter maintenance indicator is flashing, it’s time to check the filter.
    • Complete the filter maintenance process.
    • To reset the filter, press the button for 12 seconds.
  5. Maintenance schedule:
    • Perform yearly maintenance checks to ensure optimal operation of the heat recovery system.
    • These checks can be carried out by the user or a maintenance company.
  6. Service:
    • The unit should be serviced every 2 years by EnviroVent, a maintenance company, or a competent person.
    • This service includes filter replacements, air flow checks, and condense drain checks.
    • Worn-out components can be exchanged and recycled at the Harrogate factory.
  7. Safety precautions:
    • Do not remove the covers from the unit.
    • Qualified personnel should conduct any repair work to avoid hazards.
    • If the supply cord is damaged, it must be replaced by the manufacturer, service agent, or a similarly qualified person.
    • In case of emergency shutdown, isolate the unit from the mains by turning it off at the isolating switch.

Whole House Heat Recovery System

What is it and why is it there?
The energiSava® 200 is a centralised heat recovery fan unit that continuously removes stale, moist air from your bathroom, kitchen, WC and replaces it with clean fresh tempered air through circular valves mounted in your ceiling and in your living room areas.

How will it help?
It will prevent the build up of moisture in the house, remove steam/condensation and odours during bathing and cooking, prevent black mould forming on the walls, behind cupboards etc. It will also help stop the dampness that you can get in your cupboards and wardrobes, on your clothes and furnishings, caused by poor ventilation. It provides continuous, all year round ideal indoor air quality.

How do I control it?
The system operates continuously 24 hours a day at a low rate known as ‘trickle’, to ensure your home is ventilated at the appropriate level. You can send the system into a higher rate called ‘boost’ in a number of ways.

Remote Control Versions

Press the button once to see the current status of your unit and again to boost the unit. The boost LED will light and the unit will go to boost for 20 minutes. When the battery requires changing, unclip the switch front cover. The battery is located on the back of the cover. Battery type – AAA x 2.

App Control Versions
For App control versions see the separate App instruction booklet. App controlled units allow a large degree of control over the unit via a smart device.
For SSID and password information, see the back page of the installation guide, or underside of unit.

Summer bypass
The summer bypass helps reduce the air temperature coming into the dwelling during the summer months. It is an automatic function and operates by diverting air around the heat recovery cell when the supply air temperature to the property is above 25°C.

Annual Running Costs

envirovent-ES200C-Home-Ventilation -System-fig-1

envirovent-ES200C-Home-Ventilation -System-fig-2

Note: All flash indicates a unit fault

Warranty

The EnviroVent energiSava® 200 is covered by a full 2-year warranty. You will find the terms of the warranty in the installation guide.

  • DO NOT switch off the unit – The unit is set to run continuously 24 hours a day, 7 days a week.
  • DO NOT adjust the ceiling valves – The valves are set to allow a certain amount of air through and should not be adjusted.

Maintenance

Recommended maintenance schedule: The following checks are recommended to ensure that this heat recovery system operates at its optimum level. Yearly maintenance and checks – To be carried out by the user or maintenance company.

  • Check there is sufficient airflow coming through the diffusers.
  • Change filters x 2 (see illustration below)
  • Call EnviroVent on 01423 810 810 -Filter part code is FILTER-ES250

envirovent-ES200C-Home-Ventilation -System-fig-3 Service

The unit should be serviced every 2 years by EnviroVent, a maintenance company or other competent person. This would include filter replacements, air flow and a condense drain check. Any worn out components can then be exchanged. These would then be brought back to the Harrogate factory to be recycled.

Safety

You do not need to remove the covers from the unit, any repair work should be carried out by a qualified person to avoid hazard. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified person.

  • Emergency shutdown details – Unit to be isolated from the mains by turning it off at the isolating switch.

We want to hear from you

Your feedback is important to us as we strive to improve our products, services, and overall customer experience. Please email us to help us serve you better: feedback@envirovent.com

E &OE | MKT ENV316 – V5 – 24.10.22
Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.

EnviroVent Ltd Harrogate West Business Park Unit 1 Bardner Bank Killinghall Harrogate HG3 2SP

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

envirovent User Manuals

Related Manuals