CHAMPION POWER EQUIPMENT 500987-UK Wireless Remote Start Inverter Generator Instruction Manual

June 13, 2024
CHAMPION POWER EQUIPMENT

500987-UK Wireless Remote Start Inverter Generator

Product Information

Product Name: MODEL #500987-UK 3500W RATED WIRELESS REMOTE START
INVERTER GENERATOR

Manufacturer: Champion Power Equipment

Contact Information: +44(0)-1942-715-407 or
www.championpowerequipment.co.uk

Product Description: The MODEL #500987-UK 3500W RATED WIRELESS
REMOTE START INVERTER GENERATOR is a portable generator designed to
provide power in remote locations. It features wireless remote
start capabilities, making it easy to start and operate. The
generator has a power output of 3500W, making it suitable for
powering various appliances and equipment. It is equipped with an
Intelligauge with Power Meter for easy monitoring of power usage.
The generator is designed with safety in mind, with features such
as carbon monoxide safety precautions and safety symbols.

Product Usage Instructions

  1. Before operating the generator, read and understand the
    operator’s manual provided.

  2. Ensure the generator is placed outside to prevent carbon
    monoxide buildup. Keep it away from doors, windows, and
    garages.

  3. Familiarize yourself with the symptoms of carbon monoxide
    poisoning and stay alert by using carbon monoxide detectors.

  4. If you experience any symptoms of carbon monoxide poisoning,
    leave the area immediately.

  5. Point the fumes away from nearby people to minimize
    exposure.

  6. Ensure the generator is registered online at
    championpowerequipment.co.uk for warranty purposes.

  7. Follow the recommended maintenance schedule provided in the
    manual to keep the generator in optimal condition.

  8. If storing the generator for a short term (up to 30 days),
    follow the instructions provided for short term storage.

  9. If storing the generator for a long term (more than 1 year),
    follow the instructions provided for long term storage.

For detailed instructions on specific topics such as cleaning
the spark arrestor, adjusting the governor, and battery
maintenance, refer to the corresponding sections in the operator’s
manual.

OPERATOR’S MANUAL
MODEL #500987-UK 3500W RATED WIRELESS REMOTE
START INVERTER GENERATOR
REGISTER YOUR PRODUCT ONLINE at championpowerequipment.co.uk
Original Instructions
+44(0)-1942-715-407
or visit www.championpowerequipment.co.uk
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product. Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice. REV 20220914

CARBON MONOXIDE SAFETY: THE BIG PICTURE
As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.

ALWAYS READ MANUAL THE OPERATOR’S
MANUAL FIRST

KNOW THE SYMPTOMS

· Headache

· Dizziness

· Nausea

· Fatigue

· Shortness of breath

STAY ALERT WITH CARBON MONOXIDE DETECTORS

KEEP IT OUTSIDE AND AWAY FROM DOORS, WINDOWS, AND GARAGES

IF YOU FEEL SYMPTOMS, LEAVE RIGHT AWAY

POINT FUMES AWAY FROM NEARBY PEOPLE

www.TakeYourGeneratorOutside.com

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

TABLE OF CONTENTS

TABLE OF CONTENTS

Cleaning the Spark Arrestor ………………………………. 32

Introduction…………………………………………… 4

Generator Battery ………………………………………… 33 Remote Key Fob Battery …………………………. ………. 34

Safety Definitions …………………………………… 4

Adjusting the Governor……………………………………. 34

Important Safety Instructions ………………….. 5
Fuel Safety ……………………………………………….. 7

Maintenance Schedule……………………………………. 34
Storage ……………………………………………….. 35

Lithium-ion Battery Safety…………………………………. 8

Short Term Storage (up to 30 days) ………………. ………. 35

Safety and Dataplate Labels……………………………….. 9

Mid Term Storage (30 days ­ 1 year) …………….. ………. 35

Safety Symbols…………………………………………… 10

Long Term Storage (more than 1 year)……………. ………. 35

Operation Symbols ……………………………………….. 12

Removing from Storage…………………………………… 36

Quick Start Label Symbols………………………………… 13 Specifications ………………………………………. 37

Controls and Features …………………………… 14

Generator Specifications…………………………. ………. 37

Generator ………………………………………………… 14

Engine Specifications ……………………………. ………. 37

Control Panel …………………………………………….. 15

Oil Specifications………………………………… ………. 37

Intelligauge with Power Meter …………………………….. 16

Fuel Specifications ………………………………. ………. 37

Wireless Remote Control………………………………….. 17

Battery Specifications……………………………. ………. 37

Parts Included ……………………………………………. 18

Temperature Specifications………………………. ………. 37

Assembly …………………………………………….. 19
Unpacking ……………………………………………….. 19 Remove Shipping Support Hardware ………………………. 19 Connect the Battery………………………………………. 19 Add Engine Oil……………………………………………. 19 Add Fuel ………………………………………………… 21 Grounding ……………………………………………….. 22
Operation …………………………………………….. 22

Wiring Diagram………………………………….. ………. 38 Parts Diagram Figure A …………………………………… 39 Parts List ………………………………………………… 40 Parts Diagram Figure E …………………………………… 42 Parts List ………………………………………………… 43 Parts Diagram Figure F …………………………………… 44 Parts List ………………………………………………… 45 Parts Diagram Figure G …………………………………… 46 Parts List ……………………………………….. ………. 47

Generator Location……………………………………….. 22

Parts Diagram Figure H …………………………………… 48

Surge Protection …………………………………………. 23

Parts List ………………………………………………… 49

Wireless Set Button ………………………………………. 23

Engine Parts Diagram Figure B …………………… ………. 50

Starting the Engine……………………………………….. 24

Engine Parts List …………………………………………. 51

Manual Choke Start ………………………………………. 26

Engine Parts Diagram Figure C …………………… ………. 53

Connecting Electrical Loads ………………………………. 27

Engine Parts List …………………………………………. 54

Do Not Overload Generator ……………………………….. 27

Engine Parts Diagram Figure D…………………… ………. 55

Eco (Economy) Mode……………………………………… 28

Engine Parts List …………………………………………. 56

12V DC Automotive Style Outlet …………………………… 28 Parallel Operation ………………………………………… 29 Stopping the Engine………………………………………. 29

Troubleshooting……………………………………. 57 WARRANTY*…………………………………………. 59

Moving the Generator …………………………………….. 30

Warranty Qualifications …………………………………… 59

Operation at High Altitude ………………………………… 30

Repair/Replacement Warranty…………………………….. 59

Maintenance ………………………………………… 31
Cleaning the Generator …………………………………… 31
Changing the Engine Oil (10W-30 Recommended) ……. 31
Cleaning and Adjusting the Spark Plug…………………….. 32 Cleaning the Air Filter …………………………………….. 32
3

Do Not Return The Unit To The Place Of Purchase …………. 59 Warranty Exclusions ……………………………………… 59 Other Exclusions ………………………………… ………. 59 Limits of Implied Warranty and Consequential Damage…….. 59 Contact Information ………………………………………. 59

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

INTRODUCTION

INTRODUCTION
Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication, and we reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
CPE highly values how our products are designed, manufactured, operated, and serviced as well as providing safety to the operator and those around the generator. Therefore, it is IMPORTANT to review this product manual and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please always exercise common sense and always err on the side of caution when operating the product to ensure no accident, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the complete model and serial numbers of your product. Transcribe the information found on your product’s nameplate label to the table below

SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE indicates information considered important, but not hazard-related (e.g., messages relating to property damage).

CPE TECHNICAL SUPPORT TEAM +44(0)-1942-715-407 MODEL NUMBER 500987-UK SERIAL NUMBER

DATE OF PURCHASE

PURCHASE LOCATION

4

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT EXHAUST AWAY WINDOWS, DOORS AND VENTS. DO NOT operate the generator inside any sheds, vehicles , including garages, basements, crawlspaces and sheds vehicles, enclosure or compartment, including the generator compartment of a recreational vehicle. DO NOT allow exhaust fumes to enter a confined area through windows, doors, vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open. ONLY use OUTSIDE and far away from windows, doors, and vents.

DANGER
Operate equipment with guards in place. Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts. Tie up long hair and remove jewelry. DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or sockets. DO NOT use electrical cords that are worn, damaged or frayed. Use only Champion electrical cords for proper application. DO NOT operate generator in wet weather incl rain or snow. DO NOT allow children or unqualified persons to operate or service the generator. Use a ground fault circuit interrupter (GFCI) in damp areas and areas containing conductive material such as metal decking(MUST be installed separately). Connection to your home’s electrical system requires a listed 100A transfer switch installed by a licensed electrician and approved by the local authority having jurisdiction. The connection must isolate the generator from the utility power and must comply with all applicable laws and electrical codes.

Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up according to the manufacturer’s instructions.
WARNING
Although the generator contains a spark arrester, maintain a minimum distance of 5 ft. (1.5 m) from dry vegetation to prevent fires.
WARNING
Always maintain a minimum distance of 3ft (0.91m) around generator to allow for adequate cooling. Do Not cover, box in or enclose this generator otherwise it will overheat and risk fire.

WARNING
Do not use generator for medical and life support uses.
In case of emergency, call emergency services immediately. NEVER use this product to power life support devices or life support appliances. NEVER use this product to power medical devices or medical appliances. Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live. Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency.

5

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

WARNING
Spark from removed spark plug wire can result in fire or electrical shock.
When servicing the generator: Disconnect the spark plug wire and place it where it cannot contact the plug or any other metal object. DO NOT check for spark with the plug removed. Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible material can catch fire on contact.
DO NOT touch hot surfaces like engine or exhaust muffler. Avoid contact with hot exhaust gases. Allow equipment to cool 30mins before handling. Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate cooling. Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.

CAUTION
Improper treatment or use of the generator can damage it, shorten its life or void the warranty.
Use the generator only for intended uses. Operate only on flat level surfaces. DO NOT expose generator to excessive moisture, dust, or dirt. DO NOT allow any material to block the cooling slots. If connected devices overheat, turn them off and disconnect them from the generator. DO NOT use the generator if: ­ Electrical output is lost ­ Equipment sparks, smokes or emits flames ­ Equipment vibrates excessively
WARNING
This product contains a button battery within the remote key fob. If swallowed, it could cause severe injury or death in just 2 hours. Seek medical attention immediately.

WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine faster than you can let go. Broken bones, fractures, bruises or sprains could result. Unintentional startup can result in entanglement, traumatic amputation or laceration.
When starting engine, pull the recoil cord slowly until resistance is felt (compression point), release cord slowly back use one strong rapid pull to start to avoid any kickback, if the engine does not start repeat the process. Do Not rigorously or aggressively pull the recoil otherwise damage will occur to cord or mechanism resulting in voiding the part warranty.

CAUTION
Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it.
DO NOT overload the generator. DO NOT tamper with the governed speed. DO NOT modify the generator in any way. Do NOT modify or install any exhaust muffler extension or extraction

6

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Fuel Safety
DANGER
PETROL AND PETROL VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Petrol and petrol vapors: ­ Petrol is highly flammable and explosive. ­ Petrol can cause a fire or explosion if ignited. ­ Petrol is a liquid fuel but it’s vapors can ignite. ­ Petrol is a skin irritant and needs to be cleaned up immediately
if spilled on skin or clothes. ­ Petrol has a distinctive odor, this will help detect potential
leaks quickly. ­ Petrol expands or contracts with ambient temperatures. Never
fill the petrol tank to full capacity, as petrol needs room to expand when temperatures rise. ­ In the case of any petroleum petrol fire, flames should never be extinguished unless the fuel supply valve can be turned OFF. By not doing so, if a fire is extinguished and the supply of fuel is not turned OFF, an explosion hazard could be created.
When adding or removing petrol: DO NOT light or smoke cigarettes. Turn the generator off and let cool for at least 30 minutes before removing the petrol cap. Always loosen the cap slowly to relieve pressure in the tank. NEVER try to refuel indoors or inside any building.Only fill or drain petrol outdoors in a well-ventilated area. DO NOT pump petrol directly into the generator at the gas station. Always use an approved container to transfer the fuel to the generator. DO NOT overfill the fuel tank. Always keep petrol away from sparks, open flames, pilot lights, heat and other sources of ignition.
When starting the generator: DO NOT attempt to start a damaged generator. Always check that the fuel cap, air filter, spark plug, fuel lines and exhaust system are properly in place. Always allow spilled petrol to evaporate fully before attempting to start the engine. Always be certain that the generator is resting firmly on level ground.
When operating the generator:

DO NOT move or tip the generator during operation. When transporting or servicing the generator: Always check that the fuel valve is in the OFF position and the petrol tank is empty. For Propane compatible models, check that the Propane cylinder is disconnected and stored securely away from the generator. Disconnect the spark plug wire. When storing the generator: Store away from sparks, open flames, pilot lights, heat and other sources of ignition. Do not store generator, petrol or Propane cylinders near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
DANGER
NEVER place a petrol container, petrol tank, Propane cylinder or any combustible material in the path of the exhaust stream during operation of the engine.
WARNING
Never use a petrol container, fuel tank, or any other fuel item that is broken, cut, torn or damaged.

7

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Lithium-ion Battery Safety
Electrolyte inside the battery is harmful to skin and eyes. If the battery leaks and electrolyte gets in your eyes, do not rub them. Instead, rinse them with clean running water and immediately seek medical attention. If left untreated, electrolyte can cause permanent eye injury.
When using the generator:
­ Do not use the battery near sources of high heat or fire.
­ Do not reverse or short-circuit the positive (+) or negative (-) terminals.
­ Do not use the battery in parallel or in series.
­ Do not discharge battery in temperatures below 14°F (-10°C) or above 104°F (40°C).
When charging the battery:
­ Do not charge the battery with voltage over 15.0V and current over 1.6A.
­ Do not charge the battery below 32°F (0°C) or above 113°F (45°C).
­ Always remove from the battery cradle before charging separately.
­ After charging, leave the battery sitting for 0.5 to 1 hour before checking the voltage. If the voltage is less than 12.8V, additional charging is necessary.
­ If the battery becomes hot to the touch, stop charging. Allow battery to cool before resuming.
When storing the generator/battery:
­ Always check that the battery connectors between the inverter and the battery are unplugged and placed away from the battery terminals.
­ Always inspect the battery case for obvious signs of physical damage or warpage.
­ Do not store the battery near sources of high heat or fire.

­ Store the battery in a dry, well ventilated area between -4°F (-20°C) and 104°F (40°C).
­ Do not store the battery when discharged to 20% or less state of charge (SOC).
­ The battery should be charged for 10~30 mins every 180 days when in storage, to keep the battery in good condition.
In case of battery damage:
­ If damaged, battery may emit hazardous fumes. If fumes are present, move battery to a well-ventilated area.
­ Do not try to repair the battery.
­ Dispose of battery in a clear plastic bag and take to your local municipal household hazardous waste (HHW) recycling center. Do not place it the trash for any reason.

8

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Safety and Dataplate Labels
These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.

B A
C D
Top

A

LABEL

DANGER

GEFAHR

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon
monoxide. This is a poison you cannot see or smell.

Die Verwendung eines Stromerzeugers in geschlossenen Räumen kann Sie innerhalb weniger

Minuten töten. Die Stromerzeuger-

Abgase enthalten Kohlenmonoxid.

Dieses Gift kann man weder sehen

noch riechen. NIEMALS im Haus

NEVER use inside house, out building, sheds, garages, vehicles or confined spaces, EVEN IF if doors and windows are open and well ventilated.

ONLY use OUTSIDE and far away from windows, doors, and vents.

oder in der Garage verwenden AUCH NICHT bei geöffneten Türen und Fenstern. AUSSCHLIESSLICH im AUSSENBEREICH in gut belüfteten Zonen verwenden.

1075-BY-L-A
DANGER
Utiliser un générateur à l’intérieur PEUT VOUS TUER EN QUELQUES MINUTES. L’échappement du générateur contient du monoxyde de carbone. Il s’agit d’un poison que vous ne pouvez ni voir ni sentir. Ne l’utilisez JAMAIS dans la maison ou le garage MÊME SI les portes et les fenêtres sont ouvertes. Utilisez-le UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres, portes et trappes de ventilation.

B

UNLEADED FUEL ONLY. Minimum octane rating of 85. Maximum 10% ethanol.

NUR BLEIFREIES BENZIN. Mindest-

Oktanzahl 85. Maximal 10% Ethanol.

ESSENCE SANS PLOMB SEULEMENT.

Indice d’octane minimal de 85. Maximum 10 % d’éthanol.

1097-BY-L-A

CHAMPION POWER EQUIPMENT, INC. 12039 SMITH AVENUE

FREQUENCY (Hz)

50

NET WEIGHT

45.2kg

SANTA FE SPRINGS, CA 90670 USA / É.-U.

RPM

3600

QUALITY CLASS

A

MADE IN CHINA Low Power Generating Set

PHASE

1

MAX AMBIENT TEMP 104°F/40°C

C

MODEL

500987-UK

POWER FACTOR

1.0

INSULATION CLASS

F

SERIAL NO.

XXXXXXXXXXXX AC VOLTS

240V

RATED OUTPUT COP:3.5kW

MANUFACTURE DATE

XXXX

AC AMPS

14.6A MAX POWER

3.6kW S2 5min

IP Grade

IP23M

Performance Class

G1

1010-BY-L-A

WARNING

ADVERTENCIA

DO NOT TOUCH!

Operation of this equipment may create

NICHT ANFASSEN!

Der Betrieb dieser Geräte kann Funken erzeugen, die in

Exhaust gases, muffler sparks that can start fires around dry

Abgase, Schalldämpfer und der Umgebung von trockener Vegetation Brände

D

and engine components vegetation. A spark arrestor may be required. Motorkomponenten sind

auslösen können. Ein Funkenfänger kann erforderlich

are extremely HOT and The operator should contact local fire

extrem heiß und verursachen sein. Der Betreiber sollte sich an die örtlichen

cause burns.

agencies for laws and regulations relating to Verbrennungen.

Brandschutzbehörden wenden, um sich über die

fire prevention requirements. If installed,

Gesetze und Vorschriften in Bezug auf

clean every 100 hours or every season.

Brandschutzanforderungen zu informieren. Wenn

installiert, alle 100 Stunden oder zu jedes Jahr reinigen.

9

DESCRIPTION Safety Symbols/
CO Danger
Fuel
Dataplate
Hot Surface

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Safety Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.

SYMBOL

MEANING

Caution.

Read The Operator’s Instruction Manual Before Use. To reduce the risk of injury, user must read and understand operator’s manual before using this product.

Not For General Waste Disposal.

The generating set must not be connected to other power sources, such as the power company supply mains.
Electric Hazard. Failure to use in dry conditions and to observe safe practices can result in electric shock. Improper connections to a building can allow current to backfeed into utility lines, creating an electrocution hazard. A transfer switch must be used when connecting to a building.
Fire Hazard. Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. Keep generator at least 5 feet (1.5m) from all objects to prevent combustion.

Risk Of Being Burnt. To reduce the risk of injury or damage, avoid contact with any hot surface.

Carbon Monoxide(co) Danger.
Wet Conditions Alert. Do not expose to rain or use in damp locations except as follows: If you must operate in rain or damp locations, DO NOT operate without proper protection of the electrical components. Use of a safety canopy that is fire retardant and will provide proper air ventilation for the engines exhaust stream can be used. Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times. Heat from the muffler surface and exhaust stream can ignite combustible materials.

10

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

SYMBOL

MEANING

Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product.

This product uses lithium-ion (Li-ion) batteries. Local, state, or federal laws may prohibit disposal of batteries in ordinary trash. Consult your local waste authority for information regarding available recycling and/or disposal options.

Blindness or severe burns. Electrolyte solution can cause blindness or severe burns.

Shield eyes. Explosive gases can cause blindness or injury. If damaged, battery may emit hazardous fumes. If fumes present, move battery to a well- ventilated area.

Eye protection. Always wear eye protection with side shields marked to comply with ANSI Z87.1.

It is recommended ear protection is worn working at close quarters to the generator.

11

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Operation Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.

SYMBOL

Start

MEANING

SYMBOL

MEANING Ground Terminal

On

Parallel Connection(s)

Stop or Off
Choke
Run
12V Direct Current
Battery On
Battery Off Neutral Floating. Neutral circuit IS NOT electrically connected to the frame/ ground of the generator. Circuit Breaker Reset: Push

Economy Mode Button ECO
Overload Reset Button
Low Oil
Wireless Pair
Fuel Tank: Full
Fuel Tank: Empty
Power Output. Percentage of available power from generator being used.

12

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

IMPORTANT SAFETY INSTRUCTIONS

Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.

1

2

3

4

5

6

7

8

1

2

3

10W-30

1086-BY-L-A

Starting the Engine
DANGER
Move generator outside and far away from windows, doors and intake ventilation covers.
1. Check oil level. Recommended oil is 10W-30.(Not Included)
2. Check petrol level. When adding petrol, use a minimum octane rating of 85 and an ethanol content of 10% or less by volume. y
3. Turn battery switch to the “ON” position. 4. Turn the EZ Start dial to the “ON” position. 5. Press the choke button. Note: If battery is dead, charge
battery or remove the non recoil side maintenance cover and move choke lever to choke position to start. 6. Pull the recoil cord. 7. Press the choke button. 8. Plug in desired device.

Stopping the Engine 1. Turn off and unplug all connected electrical loads. 2. Turn the EZ Start dial to the “STOP” position. 3. Turn battery switch to the “OFF” position. Wireless and Electric Start See page 22 in “Operation” section.

13

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

CONTROLS AND FEATURES

CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.

Generator

2

3

1

9 8

4 5

7 6

10

11

1. Folding Handle ­ Used to move unit by lifting and rolling on wheels. Do not use to lift or carry the unit.
2. Fuel Cap ­ Remove to add fuel. 3. Fuel Gauge 4. Battery Access Cover 5. Control Panel ­ See Control Panel section.

6. Recoil Starter ­ Used to manually start the engine. 7. Never Flat Wheels ­ 5 in. (12.7 cm) 8. Oil Fill Access Cover 9. Carrying Handle(s) ­ Used to lift or carry the unit. 10. Muffler 11. Maintenance Cover

14

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Control Panel

CONTROLS AND FEATURES

4 1
A

2

4

5

3

B

6

7

1. Intelligauge with Power Meter ­ See Intelligauge with Power Meter section.
2. Ignition Switch ­ Used to START the generator.
3. EZ Start Dial ­ Used to start and stop.
4. Circuit Breakers (Push Reset) ­ Protects the generator against electrical overloads.
5. Battery Switch ­ Enables/disables power supply from battery for remote and electric start.
6. Ground Terminal ­ Consult an electrician for local grounding regulations.
7. Parallel Outlets ­ Used to parallel two inverters together for increased power output. (parallel kit sold separately).

RECEPTACLES

(2×) 240V AC, 13A

A

May be used to supply electrical power for operation of 240 Volt AC, 13 Amp, single phase,

50 Hz electrical loads.

12V DC, 8A (Automotive)

z B

May be used to supply electrical power for

operation of 12 Volt DC, 8 Amp electrical loads.

WARNING
Do not operate a device while it is plugged into the 12V DC outlet. When charging a device, do not place on the exhaust side of the generator. Extreme heat caused by exhaust can damage the device and cause a potential fire hazard. Prolonged exposure to engine exhaust can cause serious injury or death.

WARNING
Do Not use both 240V AC and 12V DC together ONLY use one at a time separately otherwise you could damage equipment or generator.

15

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Intelligauge with Power Meter
The meter is divided into two seperate displays. The LCD displays each mode for several seconds and then automatically cycles through. The Power Meter LED displays output in percent (%) with 100% at the top.

CONTROLS AND FEATURES

MODE

Voltage (V)

Example: 240 volts

DESCRIPTION Output voltage of the generator.

Frequency (H)

Example: 50.0 hertz

Output frequency in hertz.

Run Time (R)

Example: 6 hours

Run time of the generator for the current session.

Total Run Time Example: 16 hours

Total run time of the generator since first operation.

Power Meter

Example: 100% Output

Power Output percentage.

16

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Wireless Remote Control
This generator is equipped with a wireless remote control system for starting and stopping. The system consists of (5) main components:
1. Receiver Control Module (RCM)
2. Remote Control
3. Battery Switch
4. EZ Start Dial
5. Auto-Choke
The Remote Control functions are enabled when:
1. The EZ Start Dial is in the “ON” position, AND
2. The Battery Switch is in the “ON” position.
The Remote Control functions are disabled if either of the above conditions is not met.
To start the generator wirelessly, press the “START” button on the Remote Control one time. The engine will attempt to start (6) times. The RCM controls the Auto-Choke during each attempt to start. If the generator does not start, call Champion Customer Care team for assistance at +44(0)-1942-715-407.
To stop the generator wirelessly, press the “STOP” button on the Remote Control one time.
Remote Control Power Consumption
While the EZ Start Dial is in the “ON” position, the RCM is active and waiting for a remote signal. This function requires electrical current from the battery. If the EZ Start Dial is left in the “ON” position for extended periods (several weeks), the battery can be completely drained.
Moving the EZ Start Dial to the “OFF” position disables the Remote functions, but the RCM still consumes approximately 2 mA from the battery.
To prevent battery drain, press the Battery Switch to the “OFF” position. This disconnects power to the RCM so there is no current draw on the battery.

CONTROLS AND FEATURES

17

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts Included
Accessories Oil Funnel ………………………………………………….. 1 Remote Key Fob ……………………………………………. 1 12VDC USB Adapter………………………………………… 1 12VDC Battery Charging Cable ……………………………… 1

CONTROLS AND FEATURES

Tools Included 8/10 mm Wrench…………………………………………… 1 Spark Plug Socket………………………………………….. 1 Reversible Phillips/Flathead Screwdriver…………………….. 1

18

IMPORTANT
500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

ASSEMBLY

ASSEMBLY
Your generator requires some assembly. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our Technical Support Team at +44(0)-1942-715-407. Please have your serial number and model number available.

Connect the Battery
1. Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver (not included).
2. Push two halves of battery connector together tightly.

Unpacking
1. Set the shipping carton on a solid, flat surface. 2. Remove everything from the carton except the generator. 3. By lifting up on the carrying handles, carefully remove the
generator from the box (two people lifting is recommended).

Remove Shipping Support Hardware
To protect the generator during shipping, support hardware has been installed between the engine and frame. This hardware MUST BE REMOVED BEFORE adding oil or petrol to the generator.
NOTICE
DO NOT attempt to run generator without first removing the shipping support hardware. Damage to the generator as a result of not removing the hardware will void the warranty.
1. BEFORE filling the engine with oil or petrol, tip the generator onto the muffler side. Tip onto the flattened cardboard box the generator came in or other protective surface so as to not scratch the enclosure.
2. Remove the four nuts and mounting plates from the bottom side of the generator using the included 8/10 mm wrench. Nuts and spacers can be discarded.
3. Tip the generator upright.

Add Engine Oil
CAUTION
DO NOT tip or overfill the generator otherwise it will cause degraded engine performance and(or) damage the engine resulting in voiding any warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is Motul PowerX 10w30 Generator oil. However, using the listed conventional oils shown in the “Recommended Engine Oil Type” chart may be used for typical use including the first 5 hours of the breakin run time period of the engine. If running generator in extreme temperatures, refer to the “Recommended Engine Oil Type” chart.

Recommended Engine Oil Type 10W-30

5W-30

10W-40

5W-30 Full Synthetic

°F -20

0

20 40 60 80 100 120

°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9

Ambient temperature

1. Place the generator on a flat, level surface.

19

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

ASSEMBLY

2. Turn the oil access cover fastener to the unlocked position and remove the cover.

NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in the dipstick while checking.As a general rule on a flat level surface oil is full when it can be visually seen on the middleupper threads of the port, Do Not overfill otherwise it will result it poor engine performance and(or) damage to the engine.

NOTICE
Check oil level often during the break-in period. Refer to the Maintenance section for recommended service intervals.

3. Remove oil fill cap/dipstick to add oil.
4. Using a funnel, add up to 16.9 fl. oz. (500 ml) of oil . DO NOT OVERFILL OR TIP GENERATOR WHEN FILLING OIL. Replace oil fill cap/dipstick and secure maintenance cover.

CAUTION
This engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level.
NOTICE
The first 5 hours of run time are the break-in period for the unit. During the break in period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator windings to heat and cool. Adjusting the load will also cause engine speed to vary slightly and help seat piston rings. After the 5 hour break-in period, change the oil.

5. Check engine oil level before each use and add as needed. OIL DIP STICK

NOTICE
Synthetic oil may be used after the 5 hour initial break-in period. Using synthetic oil does not decrease the recommended oil change interval. Full synthetic 5W-30 oil will aid in starting in cold ambient < 41º F (5º C) temperatures.

MAX

20

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

ASSEMBLY

Add Fuel y
DANGER
Petrol vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or death. Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump petrol directly into the generator. Use an approved container to transfer the fuel to the generator.
Never use a petrol container, fuel tank, or any other fuel item that is broken, cut, torn or damaged. DO NOT overfill the fuel tank. Always keep fuel away from sparks, open flames, pilot lights, heat and other sources of ignition.
Use clean, fresh, regular unleaded petrol with a minimum octane rating of 85 and an ethanol content of 10% or less by volume. ybc
DO NOT mix oil with petrol. 1. Remove the fuel cap. 2. Slowly add petrol to the tank. Tank is full when petrol reaches
red circle on screen. DO NOT OVERFILL. Petrol can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for petrol expansion, although more than ¼ in. (6.4 mm) is recommended. Petrol can be forced out of the tank as a result of expansion if overfilled, and can affect the stable running condition of the generator.

Empty

Full

4. Screw on the fuel cap and wipe away any spilled fuel.
CAUTION
Use unleaded petrol with a minimum octane rating of 85 and an ethanol content of 10% or less by volume. y
DO NOT light cigarettes or smoke when filling the tank. DO NOT mix oil and petrol.Never mix oil and petrol, this is four stroke engine and requires separate oil and fuel. DO NOT overfill the tank. Fill tank to approximately ¼ in. (6.4 mm) below the top of the tank to allow for petrol expansion. DO NOT pump petrol directly into the generator at the pump. Use an approved fuel container to transfer the petrol to the generator. DO NOT fill tank indoors, in building and(or) any out building or vehicles DO NOT fill tank when the engine is running or hot always allow to cool for minimum 30mins.

WARNING
Pouring petrol too fast through the fuel screen may result in petrol splashing over the generator and operator while filling.

3. The approximate fuel level is shown on the fuel gauge on top of the fuel tank.

21

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

NOTICE
The generator engine works well with 10% or less ethanol blend petrol. When using ethanol-petrol blends there are some issues worth noting:
­ Ethanol-petrol blends can absorb more water than petrol alone.
­ These blends can eventually separate, leaving water or a watery goo in the tank, fuel valve and carburetor. The compromised petrol can be drawn into the carburetor and cause damage to the engine and/or potential hazards.
­ If a fuel stabilizer is used, confirm that it is formulated to work with ethanol-petrol blends.
­ Any damages or hazards caused by using improper petrol, improperly stored petrol, and/or improperly formulated stabilizers, are not covered by manufacturer’s warranty.
It is advisable to always shut off the fuel supply and run the engine to starvation after each use. See Storage instructions for extended non-use.
Grounding
Your generator must be properly connected to an appropriate ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the panel of the generator has been provided (see Controls and Features for terminal location). For remote grounding, connect a length of heavy gauge (12 AWG minimum) copper wire between the generator ground terminal and a copper rod driven into the ground. We strongly recommend that you consult with a qualified electrician to ensure compliance with local electrical codes.
Neutral Floating
­ Neutral circuit IS NOT electrically connected to the frame/ ground of the generator.
­ The generator (stator winding) is isolated from the frame and from the AC receptacle ground pin.
­ Electrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional.
Neutral Bonded to Frame

­ Neutral circuit IS electrically connected to the frame/ground of the generator.

­ The generator system ground connects lower frame crossmember below the alternator. The system ground is connected to the AC neutral wire.

  • See your Specifications section for specified type of grounding.
    OPERATION
    Generator Location
    WARNING
    NEVER operate the generator inside any building, garage, basement, crawlspace, shed, enclosure or compartment, including a generator compartment of a recreational vehicle.
    NEVER operate or start the generator in the back of an SUV, camper, trailer, truck bedor any vehicles (regular sides, flat or other configuration), under staircases, stairwells, next to walls or buildings or in any other location that will not allow for adequate cooling of the generator or for the proper exit of the exhaust flow from the muffler system.
    DO NOT operate or store the generator in wet weather conditions such as rain or snow. Using a generator in wet conditions could result in serious injury or death due to electrocution.
    In some state’s generators may be required to be registered with the local utility company when used at construction sites and may be subject to additional rules and regulations, consult your local municipal authority.
    Generators should always be operated on a flat, level surface at all times (even when not in operation).
    Generators must have a minimum of 5 feet (1.5 m) of clearance from all combustible material.
    Generators must also have a minimum of 3 feet (91.4 cm) of air flow clearance on all sides to allow for adequate performance cooling, maintenance and servicing.
    Always place the generator in a well-ventilated area. NEVER place the generator near air intake vents or where exhaust fumes could be drawn into occupied or confined spaces.
    Always carefully consider wind and air currents when positioning generator.
    Always allow generators to properly cool before transport or for storage purposes.
    Failure to follow proper safety precautions may result in personal injury, damage to the generator and void the manufacturer’s warranty.

22

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

WARNING
During operation the muffler and exhaust fumes will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or enclosed, temperatures can become extremely heated and may lead to fire.
WARNING
Never modify or install any exhaust muffler extension or extraction otherwise it will cause degraded engine performance and(or) damage engine resulting in voiding any warranty.

2. Turn the battery switch to the “ON” position.

Wet Conditions Alert: Do not expose to rain or use in damp locations except as follows:
If you must operate in rain or damp locations, DO NOT operate without proper protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper air ventilation for the engines exhaust stream can be used. Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times. Heat from the muffler surface and exhaust stream can ignite combustible materials.
Visit championpowerequipment.com or call to find your Storm Shield cover.
Surge Protection
Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations. While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment.
­ Install certified-listed, plug-in surge suppressors on the outlets feeding your sensitive equipment. Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short-duration voltage fluctuations.
Wireless Set Button
The wireless set button is a feature that lets the user synchronize the remote key fob to the generator. Up to two remote key fobs can be paired to one generator at a time. Follow the proceeding steps to reset a remote or pair two remotes:
1. Turn the EZ Start Dial to the “ON” position.

3. Push and hold the wireless set button found on the Intelligauge for approximately three seconds until the button LED illuminates blue.
4. Push and release the STOP $ button on the remote key fob. The blue LED on wireless set button will blink once to indicate program is erased and generator is ready for pairing.

5. Push and release the START a button on the remote key fob. The blue LED on wireless set button will blink once to indcate the remote has been programmed.
23

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

6. Push and hold the wireless set button approximately three seconds until the blue LED on wireless set button turns off.

2. Turn the EZ Start Dial to the “ON” position.

7. Follow the remote START and STOP instructions to verify the remote(s) are working properly.
NOTICE
Two remote key fobs can be paired to one generator at one time. If pairing second remote and do not want to erase programming on current remote, skip step 4.
NOTICE
Changing a remote key fob battery may not require the user to reset the remote. If remote does not function after changing the battery, proceed with Wireless Set Button instructions.
Starting the Engine
1. Make certain the generator is on a flat, level surface. Wireless Remote Start Wireless remote starting is only possible within 80 feet of the generator. DO NOT attempt to adjust the choke. The remote system will automatically close and open the choke. 1. Push the battery switch to the “ON” position.

3. Press and release the “START” button on the remote control. DO NOT hold the button down, only press the button once. The engine will attempt to start six times.
Electric Start 1. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices plugged in or turned on. 2. Push the battery switch to the “ON” position.

24

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

3. Turn the EZ Start Dial to the “ON” position.

6. Do not over-choke. As soon as engine starts, push the choke button one time to set the choke to the “RUN” position. Choke button will no longer be illuminated when in “RUN” position.

4. Push the choke button one time to set the choke to the “CHOKE” position. Choke button will illuminate when in “CHOKE” position.

CAUTION
If the ignition switch is held down in the “START” position longer than 5 seconds it could damage the starter.
Manual Start 1. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices plugged in or turned on. 2. Push the battery switch to the “ON” position.

5. Press and hold the yellow ignition switch on the EZ Start Dial toward the center of the dial. Release as the engine begins to start. If the engine fails to start within five seconds, release the switch and wait at least ten seconds before attempting to start the engine again.

3. Turn EZ Start Dial to the “ON” position.

25

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

4. Push the choke button one time to set the choke to the “CHOKE” position. Choke button will illuminate when in “CHOKE” position.

NOTICE
If the engine starts but does not run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.

5. Pull the recoil cord slowly until resistance is felt (compression point), then release the cord slowly back use one strong rapid pull to start, if the generator does not start repeat the process.

WARNING
Pull the recoil cord slowly until resistance is felt (compression point), then release the cord slowly back use one strong rapid pull to start, if the generator does not start repeat process.
DO NOT rigorously or aggressively pull the recoil otherwise it will damage cord or mechanism and result in voiding your warranty.
Manual Choke Start
If the battery is dead or not able to produce enough current to power the push button choke, the choke itself can be operated manually to help start the engine. To manually choke and start the generator, follow these steps:
1. Loosen the two screws and remove the maintenance cover.

6. Do not over-choke. As soon as engine starts, push the choke button one time to set the choke to the “RUN” position. Choke button will no longer be illuminated when in “RUN” position.
2. Locate the yellow manual choke lever. 3. Turn the choke lever to the “CHOKE” (right) position.
26

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

NOTICE
For electric and manual starts only (not wireless remote start): Keep choke in “CHOKE” position for only 1 start attempt. After first start attempt, move the choke to the “RUN” position for up to the next 3 start attempts. Too much choke leads to spark plug fouling/engine flooding due to the lack of incoming air. This will cause the engine not to start.

4. Turn the EZ Start Dial to the “ON” position.
5. Pull the recoil cord slowly until resistance is felt (compression point), then release the cord slowly back use one strong rapid pull to start, if the generator does not start repeat the process.
6. Do not over-choke. As soon as engine starts, move the choke lever to the “RUN” (left) position.

Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 240 Volt AC single phase, 50 Hz electrical loads.
­ DO NOT connect 3-phase loads to the generator.
­ DO NOT overload the generator.
WARNING
Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home. Connecting a generator to your home’s electric utility company’s power lines, or to another power source, called `backfeeding’ is a dangerous practice that is illegal in many states and municipalities.
This action if done incorrectly could damage your generator, appliances and could cause serious injury or death to you or a utility worker when attempting to restore power during an outage occurrence in the neighborhood who may then unexpectedly encounter high voltage on the utility line and suffer a fatal shock.
Whether injuries occur or not, if installed incorrectly and not to applicable laws and codes, you may be subject to fines or the utility company may disconnect your home power should this practice be found in your home.
If the generator will be connected to a building electrical system, those connections must isolate the generator power from the utility power. You are responsible for ensuring your generator’s electricity does not backfeed into the electric utility power lines. These connections must comply with all applicable laws and codes ­ Consult your local utility company or a qualified electrician to properly install this connection.

Do Not Overload Generator
Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes:

27

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

1. Select the electrical devices you plan on running at the same time.
2. Total the running watts of these items. This is the amount of power you need to keep your items running.
3. Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step 2. Starting wattage is the surge of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.
4. If the generator power output is cut off due to an overload condition indicated by the AC overload blinking light, lower the load by unplugging one or more items, then press the AC overload reset button before restarting the generator for continued normal operation.

Eco (Economy) Mode
The Eco Mode button can be activated to turn on economy control in order to minimize fuel consumption and noise while operating the unit during times of reduced electrical output. Eco Mode allows the engine speed to idle during periods of non-use.
The engine speed returns to normal when an electrical load is connected. When the economy switch is off, the engine runs at normal speed continuously.

CAUTION
For periods of high electrical load or momentary fluctuations, the Eco Mode should be off.

Power Management Use the following formula to convert voltage and amperage to watts:
Volts × Amps = Watts To prolong the life of your generator and attached devices, follow these steps to add electrical load: 1. Start the generator with no electrical load attached. 2. Allow the engine to run for several minutes to get up to
temperature. 3. Plug in and turn on the first item. It is best to attach the item
with the largest load first. 4. Allow the engine to stabilize. 5. Plug in and turn on the next item. 6. Allow the engine to stabilize. 7. Repeat steps 5-6 for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the generator.

12V DC Automotive Style Outlet
The 12V DC outlet(s) can be used with supplied accessories and other commercially available 12V DC automotive style plugs. Confirm the input voltage range of your item is at least 12-24V DC.
WARNING
Do not operate a device while it is plugged in to the 12V DC outlet.
Prolonged exposure to engine exhaust can cause serious injury or death.
WARNING
While charging a device do not place on the exhaust side of the generator. Extreme heat caused by exhaust can damage the device, and cause a potential fire hazard.

28

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

WARNING
This 12V DC socket is unregulated and it is not recommended running any piece of equipment off it otherwise you could damage equipment or generator. Do Not use both 240V AC and 12V DC together ONLY use one at a time otherwise you could damage equipment or generator.
Failure to follow these warning will result in voiding your warranty.
External Battery Charging
1. Before connecting the battery charging cable (not included) to a battery that is installed in a vehicle, disconnect the vehicle battery ground cable from the negative (­) battery terminal.
2. Plug the battery charging cable into the 12V DC receptacle of the generator.
3. Connect the red (+) battery charger lead to the red (+) battery terminal.
4. Connect the black (­) battery charger lead to the black (­) battery terminal.
5. Start the generator.
Important: The 12V DC outlet is ONLY to be used with supplied accessories and other commercially available 12V DC automotive style plugs. Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator.

Parallel Operation
The Champion model 500987-UK is parallel ready and can be operated in parallel with another Champion unit to increase the total available electrical power. A Champion model 75500i-WLUK parallel kit (sold separately) is required for parallel operation. For a list of compatible models or to order a parallel kit, please call customer service at +44(0)-1942-715-407 or visit www. championpowerequipment.co.uk
Detailed instructions for parallel kit installation and operation of the connected generators are provided in the parallel kit operator’s manual.
Stopping the Engine
Remote Stop
1. Turn off all electrical connected loads. Never start or stop the generator with electrical devices turned on.
2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.
3. Press the “STOP” button on the remote.

WARNING
Do not start the vehicle while the battery charging cable is connected and the generator is running. It will not give the battery a boost of power. The vehicle or the generator may be damaged. Charge only vented wet lead acid batteries. Other types of batteries may burst, causing personal injury or damage.Do Not use both 240V AC and 12V DC together ONLY use one at a time otherwise you could damage equipment or generator.
NOTICE
Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator.

NOTICE
Engine will shut off but the battery switch and EZ Start Dial will remain in the “ON” position waiting for the next start instruction.
To completely shut down the generator, make sure the EZ Start Dial and battery switch are in the “OFF” position when the generator will not be used for an extended period of time.
NOTICE
Battery power is drawn while the generator is in standby mode (battery switch ON). Do not leave generator in standby mode for an extended period of time or the battery will be completely drained and the wireless remote and electric start feature will no longer function.

Manual Stop

29

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

OPERATION

1. Turn off and unplug all electrical connected loads. Never start or stop the generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.
3. Turn the EZ Start Dial to the “OFF” position.

1. Begin by raising the folding handle, found on opposite side of wheels.
2. Using the handle, tilt the end of the generator slightly off the ground until balanced on the wheels.
3. While maintaining balance, roll the generator to the desired location.

4. If battery switch is in the “ON” position, press the battery switch to the “OFF” position.
Important: Always ensure that the EZ Start Dial and battery switch are in the “OFF” position when the generator will not be used for an extended period of time.
NOTICE
If the engine will not be used for a period of two (2) weeks or longer, please see the Storage section for proper engine and fuel storage.
Moving the Generator
­ NEVER lift or carry the generator using the folding handle. ­ ALWAYS place the generator on its wheels in the upright
position. ­ ALWAYS turn the generator off. ­ ALWAYS make sure engine and muffler are cooled down
before the generator can be handled safely (typically 30 minutes).

­ NEVER tilt sideways while moving the generator.
­ Failure to follow these instructions could result in personal injury or damage to the generator.

Operation at High Altitude
The density of air at high altitudes is lower than at sea level. Engine power is reduced as the air mass and air-fuel ratio decrease. Engine power and generator output will be reduced approximately 3½% for every 1000 ft. of elevation above sea level. At high altitudes increased exhaust emissions can also result due to the increased enrichment of the air fuel ratio. Other high altitude issues can include hard starting, increased fuel consumption and spark plug fouling.
To alleviate high altitude issues other than the natural power loss, CPE can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting our Technical Support Team. Installation instructions are also available in the Technical Bulletin area of the CPE website.
The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the following table.
In order to select the correct high altitude main jet it is necessary to identify the carburetor model. For this purpose, a code is stamped on the side of the carburetor. Select the correct high altitude jet part number corresponding to the carburetor code found on your particular carburetor.

Carb. Code
16161Z09051000A0

High Alt. Jet Part Number 16161-Z090410-00A0 16161-Z140310-00A0

Min. Altitude
3000 ft. (914 m) 6000 ft. (1829 m)

30

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

MAINTENANCE

WARNING
Operation using the alternative main jet at elevations lower than the recommended minimum altitude can damage the engine. For operation at lower elevations, the originally supplied standard main jet must be used. Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance.

1. Use a damp cloth to clean exterior surfaces of the generator.
2. Use a soft bristle brush to remove dirt and oil.
3. Use an air compressor (25 PSI) to clear dirt and debris from the generator.
4. Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
To prevent accidental starting, remove and ground the spark plug wire before performing any service.

MAINTENANCE
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
WARNING
Never operate a damaged or defective generator.
WARNING
Improper maintenance will void your warranty.The owner/ user is responsible for service and maintenance of the generator including oil, spark plug, spark arrestor, filters and valve adjustments. Improper servicing or maintenance of this generator will void any warranty.
NOTICE
For Emission control devices and systems, read and understand your responsibilities for service as stated in the Emission Control Warranty Statement of this manual.

Changing the Engine Oil (Champion PowerX 10w30 oil)
Change oil when the engine is warm. Refer to the oil specification to select the proper grade for your operating environment. 1. Place the generator on a flat level surface. 2. Turn the oil access cover fastener to the unlocked position
and remove the cover. 3. Remove the oil drain plug by turning it counter clockwise.
DRAIN PLUG
DRAIN TUBE 4. Ensure the oil drain hose is lower than the engine and allow
the oil to drain completely into an appropriate container.

The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. For service or parts assistance, contact our Technical Support Team at +44(0)-1942-715-407.
Cleaning the Generator
CAUTION
DO NOT spray, jet or pressure wash generator directly with water.
Water can enter the generator through the cooling slots and damage the generator windings. It can also contaminate the fuel system.

5. Replace the oil drain plug.
6. Add oil according to Add Engine Oil in Assembly section. DO NOT OVERFILL. Oil not included for routine maintenance.
7. Dispose of used oil at an approved waste management facility.

31

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking.As a general rule on a flat level surface oil is full when it can be visually seen on the middle-upper threads of the port, Do Not overfill otherwise it will result it poor engine performance and(or) damage to the engine.

MAINTENANCE

Cleaning and Adjusting the Spark Plug
1. Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver (included).
2. Remove the spark plug cable from the spark plug.
3. Use a spark plug socket tool (included), or a 13/16 in. (21 mm) socket (not included) to remove the plug.
4. Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.
5. Make certain the spark plug gap is 0.028-0.031 in. (0.7-0.8 mm).

2. Locate the air filter plastic cover and remove by pinching the clips together and pulling the cover off.

SPARK PLUG GAP

6. Refer to the spark plug types in Specifications when replacing the plug.
7. Firmly re-install the plug. 8. Attach the spark plug cable to the spark plug.
9. Reinstall the maintenance cover.
Cleaning the Air Filter
1. Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver (included).

3. Remove the foam element. 4. Wash in liquid detergent and water. Squeeze thoroughly dry in
a clean cloth. 5. Saturate in clean engine oil. 6. Squeeze in a clean, absorbent cloth to remove all excess oil. 7. Place the filter in the assembly. 8. Reattach the air filter cover. 9. Reinstall the maintenance cover and tighten the cover screw
securely.
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark arrestor.
2. Remove the two screws holding the cover plate which retains the spark arrestor to the muffler.
3. Remove the spark arrestor and spark arrestor screen. 4. Carefully remove the carbon deposits from the spark arrestor
and spark arrestor screen with a wire brush.

32

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

MAINTENANCE

battery must be connected to a standard automotive style battery charger for re-charging before it can be used. Disconnect the Battery
1. Pull two halves of battery connector apart.

5. Replace the spark arrestor and spark arrestor screen if it they damaged.
6. Position the spark arrestor and spark arrestor screen on the muffler and cover plate and screws removed in step 2.
CAUTION
Failure to regularly check or clean the spark arrestor will result in degraded engine performance and(or) damage the engine. Recommended every 100 hours check or clean spark arrestor.
NOTICE
Federal and local laws and administrative requirements indicate when and where spark arrestors are required. When ordered, spark arrestors are required for operation of this generator in National Forest lands. In California, this generator must not be used on any forest-covered land, brush-covered land, or grass-covered land unless the engine is equipped with a spark arrestor.
Generator Battery
Your generator is equipped with an automatic battery charging circuit that charges the battery while the engine is running. The battery will maintain a proper charge if the unit is used at least once every 180 days for 2 hours with ECO mode off. If it is used less frequently, the battery should be connected to a trickle charger or battery maintainer (not included) to keep the battery properly charged.
Maximum charging rate should not exceed 1.6 amps. Follow the instructions included with the battery charger. The battery should be fully charged at least twice per year. If the battery is not able to start the engine, it can be started by manually pulling the engine recoil cord. If the battery voltage is extremely low, the charging circuit may not be able to re-charge the battery. In this case, the

Charge the Battery
For a generator equipped with batteries for electric starting, proper battery maintenance and storage should be followed. A trickle charger or battery maintainer should be used to charge the battery while the generator is in storage. Maximum charging rate should not exceed 1.6 amps. Follow the instructions included with the trickle charger or battery maintainer. The battery should be fully charged at least once per month.
1. Remove the battery from the generator.
2. Charge battery following the battery charger’s instructions.
3. After charging, leave the battery for 0.5 to 1 hour before checking the voltage. If the voltage is less than 12.8 volts, additional charging is necessary.
NOTICE
Electrolyte inside the battery is harmful to skin and eyes. If the battery leaks and electrolyte gets in your eyes, do not rub them. Instead, rinse them with clean running water and immediately seek medical attention. If left untreated, electrolyte can cause permanent eye injury.
NOTICE
­ Do not charge the battery with charging voltage over 15.0V and charging current over 1.6A.
­ Do not charge the battery below 32°F (0°C) or above 113°F (45°C).
­ If the battery becomes hot to the touch, stop charging. Allow battery to cool before resuming.

33

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

MAINTENANCE

Remote Key Fob Battery
Batteries have a shelf life and after time used or unused will deteriorate
NOTICE
­ Always purchase the correct size and grade of battery most suitable for the intended use.
­ Clean the battery contacts and also those of the device prior to battery installation.
­ Remove batteries from equipment which is not to be used for an extended period of time.
­ Remove batteries if consumed or if product is to be left unused for a long time.

The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. Contact our Technical Support Team at +44(0)-1942-715-407 for all other service and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our Technical Support Team at +44(0)-1942-715-407 to locate the nearest CPE certified service dealer for your generator or engine maintenance needs.

1.Remove the remote key fob from the key ring.
2.Remove the screw with a Phillips screwdriver (not included) by turning anti- clockwise.
3.Pry the two halves of the remote key fob apart slightly at the key ring end gently with a small flat headed screwdriver
4.Separate the two halves of the remote key fob gently by sliding the back side of the remote key fob up toward the key ring end.
5.Carefully remove the circuit board to locate and replace the CR2016 battery.
6.Reverse these instructions from 5:1 to reassemble the remote key fob.

EVERY 8 HOURS OR PRIOR TO EACH USE Check oil level Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN) Change oil (Champion PowerX 10w30 oil Recommended)
EVERY 50 HOURS OR ANNUALLY Clean air filter Change oil if operating under heavy load or in hot
environments

EVERY 100 HOURS OR ANNUALLY
Change oil (Champion PowerX 10w30 oil Recommended) Clean/adjust spark plug Clean spark arrestor Clean fuel valve filter*

After a battery change if your remote transmitter doesn’t work you will need to pair your remote transmitter again, please follow the instructions in this manual to reprogramme transmitter to the receiver.
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your warranty.

EVERY 250 HOURS Clean combustion chamber Check/adjust valve clearance
EVERY 3 YEARS Replace fuel line*

  • To be performed by knowledgeable, experienced owners or CPE certified service centers.(charges apply).

34

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

STORAGE

STORAGE
WARNING
To avoid accidental or unintended ignition of your generator during periods of storage, the following precautions should be followed: ­ When storing the generator make sure the EZ Start dial is
set to the “OFF” position.
Short Term Storage (up to 30 days)
Petrol in the fuel tank has a maximum shelf life of up to 1 year with the addition of properly formulated fuel stabilizers and if stored in a cool, dry place. Petrol in the carburetor, however, may gum up and clog the carburetor if it isn’t used or drained within 2-4 weeks. If using the generator within 2 weeks, follow the steps according to Stopping the Engine section. 1. If not using the generator for 2-4 weeks, begin by making
sure all appliances are disconnected from the generator. 2. Start the generator as instructed in Starting the Engine
section. 3. Let the engine run until fuel starvation has stopped the
engine. 4. After the engine stops, turn the EZ Start dial
counterclockwise to the “STOP” position.

10. SLOWLY pull the recoil to rotate the engine to distribute and lubricate the cylinder.
11. Re-install the spark plug and spark plug wire. 12. Re-install the maintenance cover. 13. Clean the generator according to Cleaning the Generator. 14. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (more than 1 year)
For storage over 1 year, the fuel tank and carburetor must be completely drained of petrol. 1. Be sure all appliances are disconnected from generator. 2. Place inverter on blocks to allow appropriate petrol container
or pan to slide under inverter. 3. Remove the non recoil side maintenance cover by removing
the two screws with a phillips head screw driver (included). 4. Disconnect the battery by pulling the two halves of battery
connector apart. 5. Turn the EZ Start dial clockwise to the full “ON” position. 6. Using a flat head screwdriver, rotate drain screw
counterclockwise (3) full turns. Petrol will drain through clear tubing out underneath the inverter. Make sure draining petrol empties into an appropriate container.

Mid Term Storage (30 days ­ 1 year)
Petrol in the tank has a maximum shelf life of up to 1 year with the addition of a properly formulated fuel stabilizer and stored in a cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the fuell tank.
3. Start engine by following directions in the Starting the Engine section.
4. Run the generator for 10 minutes so the treated petrol cycles through the fuel system and carburetor.
5. Let the engine run until fuel starvation has stopped the engine.
6. After the engine stops, turn the EZ Start dial counterclockwise to the “STOP” position.
7. After fuel has run out and the engine has stopped, allow the engine to cool.
8. Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver (included).
9. Remove the spark plug and pour about a tablespoon of oil into the cylinder.

7. When petrol stops flowing from the clear tube, rotate drain screw clockwise until tight. Properly dispose of the drained petrol according to local regulations or guidelines.
8. Turn the EZ Start dial to the “STOP” position.
9. Follow steps 8-12 according to Short Term Storage.

35

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Removing from Storage
NOTICE
If the generator has been improperly stored for a period longer than 30 days with ethanol blended petrol in the fuel tank and/ or carburetor, all fuel must be drained and the carburetor must be thoroughly cleaned of ethanol build up. This process involves technically advanced tasks. For assistance please call our Technical Support Team at +44(0)-1942-715-407. If the fuel tank and carburetor were properly emptied of all ethanol blended petrol prior to the generator being stored, follow the below steps when removing from storage.
1. Be sure the EZ Start dial is in the “STOP” position. 2. Add petrol to the generator according to Add Fuel. 3. Move the EZ Start dial to the “ON” position. 4. After 5 minutes check the carburetor and air filter areas for
any leaking petrol. If any leaks are found, the carburetor will need to be disassembled and cleaned or replaced. If no petrol leaks are found, turn the EZ Start dial to the “STOP” position. 5. Check engine oil level and add clean, fresh oil if needed. See Oil Specifications for proper oil type. 6. Check and clear air filter of any obstructions such as bugs or cobwebs. If necessary, clean air filter according to Cleaning the Air Filter. 7. If disconnected, connect the battery by pushing the two halves of battery connector together tightly. 8. Start the generator according to Starting the Engine.

STORAGE

36

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

SPECIFICATIONS

SPECIFICATIONS
Generator Specifications
Generator Model ………………………………… 500987-UK Start Type ………………………….Wireless, Electric, Manual Watts (Max/Running) ……………………………. 3600/3500 Volts AC…………………………………………………. 240 AC Amps @ 240V ………………………………………. 14.6 Volts DC …………………………………………………. 12 DC Amps…………………………………………………… 8 Frequency …………………………………………….. 50 Hz Max site altitude of installation ……………………….. 1500m Measured sound pressure level (7m)………………… 68 dB(A) Measured sound pressure level (4m)………………… 72 dB(A) Noise measurement uncertainty ………………….. 1.5 dB(A) Guaranteed sound power level ……………………… 96 dB(A) Phase ………………………………………………… Single Grounding Type………………………………. Neutral Floating Weight …………………………………….. 99.6 lb. (45.2 kg) Length ……………………………………… 23.2 in. (59 cm) Width ………………………………………. 17.7 in. (45 cm) Height……………………………………….. 20.1 in. (51 cm)
Engine Specifications
Model ……………………………………………….. R210-V Displacement …………………………………………. 212 cc Type…………………………………………… 4-Stroke OHV Spark Plug OEM Type…………………………………………….. F6RTC Replacement Type…………………. NGK BPR6ES or equivalent Gap …………………………….0.028-0.031 in. (0.7-0.8 mm) Valve Intake Clearance …………….. 0.002-0.006 in. (0.05-0.15 mm) Exhaust Clearance …………… 0.002-0.006 in. (0.05-0.15 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is available at www.championpowerequipment.co.uk

Oil Specifications
DO NOT OVERFILL. Type…………………………………….. *See following chart Capacity ………………………………… 16.9 fl. oz. (500 ml)

Recommended Engine Oil Type 10W-30

5W-30

10W-40

5W-30 Full Synthetic

°F -20

0

20 40 60 80 100 120

°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9

Ambient temperature

NOTICE
Temperature will affect engine oil and engine performance. Change the type of engine oil used based on temperature shown in the “Recommended Engine Oil Type” table.

Fuel Specifications
Use unleaded petrol with a minimum octane rating of 85 and an ethanol content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT OVERFILL. y
Fuel Capacity …………………………………. 2.3 gal. (8.5 L)
Battery Specifications
Type………………………………. Rechargeable, Lithium Ion Volts DC …………………………………………………. 12 Capacity ………………………………………… …… 1.6 Ah Replacement ……………………… Contact Customer Service
Temperature Specifications
Manual Starting Temperature Range (°F/°C) .. 5 to 104/-15 to 40 Remote and Electric Starting Temperature Range (°F/°C) …………………………….. 23 to 104/-5 to 40
NOTICE
An important message about temperature: Your product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). When needed, it may be operated at temperatures ranging from 5°F (-15°C) to 122°F (50°C) for short periods of time. If exposed to temperatures outside this range during storage, it should be brought back within this range before operation. In any event, the product must always be operated outdoors, in a well- ventilated area and away from doors, windows and vents.

37

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Wiring Diagram

SPECIFICATIONS

38

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts Diagram Figure A

SPECIFICATIONS

102

39

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts List

SPECIFICATIONS

Part Number

Description

Qty.

1

90208-YB00410-00A0

Hexagon Step Bolt, M5 x 16, Black Zinc

20

2 18002HYBW0110-Q2A1 Louver, Muffler

1

3

18018-Y2P0120-00A1

Insulator Glue Cushion, Muffler

1

4

90208-YB00210-00A0

Hexagon Step Bolt, M5 x 12

10

5 18130HYBW0110-Q2A1 Muffler Guard

1

6 90115-0830-03A0

Hexagon Socket Bolt, M8 x 30, Black Zinc

4

7 80153HYBW0210-H8A1 Handle 2, Ø28 x 332 1

8 90722-YBW0110-00A1 Plug 1, End

6

9

37205-Y2V0310-00A1

Fuel Lever View, Fuel Gauge

1

10 94230HYBW0110-Q2A0 Cover, Upper

1

11 80153HYBW0110-H8A1 Handle 1, Ø28 x 273 1

16 90303-0800-31A0

Hexagon Nut, M8, White Zinc

2

17 18100-YBW0111-00A0 Muffler Assembly

1

12 18012-Z800310-0000

Bolt, M5 x 10, Spark Arrestor

2

13 18213-Z800310-0000

Cover Plate, Spark Arrestor

1

14 18218-Z800210-0000 Muffling Block

1

15 18250-Z800210-0000 Spark Arrestor

1

18 90007-0612-A1A0

Hexagon Flange Bolt, M6 x 12, White Zinc

2

19 18030HYBW0110-H7A0 Muffler Bracket

1

20 18020-YBW0110-00A0 Plate, Muffler Insulator 1

21 90001-0820-01A0

Hexagon Flange Bolt, M8 x 20, White Zinc

1

22 90007-0635-A1A0

Hexagon Flange Bolt, M6 x 35, White Zinc

1

23 18299HYBW0121-00A0 Bracket, Muffler Guard 1

24 90001-0816-01A0

Hexagon Flange Bolt, M8 x 16, White Zinc

5

25 28110HYBW0111-Q2A0 Shroud

1

26

96003-ZSS2210-0000

Fuel Assembly – See Figure F

1

27 18001-Z950110-00A0 Exhaust Outlet Gasket 2

28

90134-YB00110-00A0

Bolt, Cross Hexagon Pan Head, M5 x 12

2

29 19352HYBW0110-Q2A0 Engine Fan

1

30 90124-Y9T0310-00A0

Self Tapping Screw, PT4×13

1

Part Number

Description

Qty.

31 35613-YBE0110-0000 USB Adaptor

1

32 93130-Z010410-0100 Spark Plug Socket

1

33 93107-Y920210-01A0 Wrench, 8 x 10

1

34 54912HYBW0111-Q2A1 Left, Rotating Arm

1

35 90001-0612-03A0

Hexagon Flange Bolt, M6 x 12, Black Zinc

2

36 30431-Y2V0310-00A1

Rubber Sleeve, Ø30 x Ø40 x 9.8

2

37

30431-YBW0210-00A1

Rubber Sleeve, Ø10 x Ø11 x 180

1

38 90001-0612-01A1

Hexagon Flange Bolt, M6 x 12, White Zinc

24

39 90408-0400-E1A0

Flat Washer, White Zinc 1

Rubber Sleeve, Fuel 40 30431-YBW0310-0000 Tube, 11.5 × 13 1
× 60

41 51124-YH30110-H7A0 Bracket

1

42 90001-0616-03A0

Hexagon Flange Bolt, M6 x 16, Black Zinc

2

43 39027-YH30210-00A0 Remote Control Moduel 1

44 39024-YGM0210-00A0 Remote Control Key

1

45 30060-YB30110-00A0 Rectifier

1

46 30007-Y9X0210-00A0 Charging Module

1

47

R210DVI00FGB-CMP01

Engine Assembly – See Figure B

1

48

16804-YG80110-0001

Connection Pipe, Ø4.5 x Ø8.5 x 375

1

49 80092HYMR0110-L4A0 Cover Board, Left

1

50 16601-Y2V0210-00A1

Vibration Mount 2, Fuel Tank

4

51 80091HYBW0110-Q2A1 Shell, Left

1

52 17199-YE50210-01A0

Clip Nut, M5, White Zinc

16

53

90326-Y2V0110-00A0

Square Nut, M6, White Zinc

6

54

90208-YB00110-00A0

Hexagonal Step Bolt, M6 x 20, Black Zinc

8

55 80095HYBW0110-Q2A1 Shell, Right

1

56 80096HYMR0110-L4A0 Cover Board, Right

1

57 93120-Y020310-00A0 Screwdriver

1

58

96003-ZSS7710-0000

wheel kit – See Figure H

1

59 90255-0512-53A0

Screw & Washer Assembly, Black Zinc

8

60 37073-Y2V0110-00A0 Clip, Spring

1

40

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

SPECIFICATIONS

Part Number

Description

Qty.

61 24329-Y9T0120-Q2A1 Block 1

1

62

51197HYH30110-L4A0

Side Access Panel, Service

1

63

80105-YB00110-Q2A1

Knob, Side Access Panel, Service

1

64 90408-Y020310-00A0 Flat Washer, White Zinc 4

65 90001-0625-01A1

Hexagon Flange Bolt, M6 x 25, White Zinc

9

66

96003-ZSS3110-0000

Frame Assembly – See Figure E

1

67 54912HYBW0211-Q2A1 Right, Rotating Arm

1

68 31130-YBW0210-H6A0 Battery Box

1

69 90001-0840-01A1

Hexagon Flange Bolt, M8 x 40, White Zinc

4

70

19306-Z1D0110-00A0

Crankcase Air Deflector

1

71 54913-YBW0110-GUA0 Rotating Bar

1

72 30043-YMR0110-00A0 Inverter

1

73 90683-Y2P0210-00A0 Bushing

3

74 90406-0600-E1A0

Flat Washer, White Zinc 3

75 30431-Y2P0110-00A1 Rubber Sleeve

3

76 90305-0800-31A0

Hexagon Flange Nut, M8, White Zinc

4

77 90129-0416-01A0

Self Tapping Screw, -ST4.2*16, White Zinc

3

78

35643HYH30210-Q2A1

Knob, Switch Dial, Engine

1

79 35680HYBW0110-Q2A1 Seat, Panel

1

80 90001-0610-01A0

Hexagon Flange Bolt, M6 x 10, White Zinc

3

81

35610-YMR0110-H2A1

Panel Assembly – See Figure G

1

82 30009-YH30110-00A0 Grounding Wire

1

83 90408-0500-E1A0

Flat Washer, Ø5, White Zinc

1

84 90005-0408-09A1

Hexagon Screw, M4 x 8, White Zinc

1

85 90001-0614-01A0

Hexagon Flange Bolt, M6 x 14, White Zinc

1

86 90685-D080-0EA0

Clamp, Ø8 x 7 x 0.6

2

87 16750-Y2V0210-00A0 Fuel Valve Assembly 1

88 35160-YH30111-00A0 Switch, Engine

1

89 94111-Y2V0410-00A1 Cover Board

1

90 16527-Y2V0210-00A0

Spring, Stopper Adjusting

1

91 90543-0500-00A0

Ball, Steel

1

92 90341-YA50110-00A0 Nylon Nut

1

Part Number

Description

Qty.

93 24329-YCF0110-Q2A1 Block 2

1

94 31123HYBW0110-Q2A1 Cover, Battery

1

95

90208-Y9T0120-00A0

Hexagonal Step Bolt, M5 x 16, 6mm

1

96 90103-0416-51A0

Cross Recess Pan Head Screw, M4 x 16, 3 White Zinc

97

31115-YBW0110-00A1

Band, Battery, 177×24.5×3.8

1

98 31110-Y030610-00A0 Battery

1

99 17003HYBW0110-H7A1 Air Cleaner Support

1

100 30009-YE50210-00A0 Grounding Wire

1

101 90415-0600-Z3A1

Lock Washer, Toothed, Black Zinc

1

102 93041-YBE0110-00A0 Battery Charger Cables 1

41

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts Diagram Figure E

SPECIFICATIONS

12 3

45 6 77 5 8 5

10

11

9

14

Figure E

13 12

42

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts List

Part Number

Description

Qty.

1

90341-Y2D0210-00A0

Nylon Nut, M6, White Zinc

2

2

90408-Y840210-00A0

Flat Washer, Ø18 x 6.5 x 1.5, White Zinc

2

3

54122-YBW0110-H7A0

Left Seat 2, Handle Tube Connecting

1

4

90412-YBW0110-Q2A0

Flat Washer, Ø12.2 x 27 x 2

2

5

90412-YBW0210-01A0

Flat Washer, Ø13 x 25 x 1, White Zinc

6

6 42017-YG80110-09A0 Lock Washer

2

7

90419-YBW0110-03A0

Washer, Butterfly, Ø12.2 x 25 x 1x 2, Black Zinc

4

8

54113-YBW0120-00A0

Left Seat 1, Handle Tube Connecting

1

9

26231-YBW0110-00A0

Shaft, Fixed Axis, Black Zinc

2

10 90001-0610-03A0

Hexagon Flange Bolt, M6 x 10, Black Zinc

4

11 90007-0616-A1A0

Hexagon Flange Bolt, M6 x 16, White Zinc

4

12

54113-YBW0220-00A0

Right Seat 1, Handle Tube Connecting

1

13

54122-YBW0210-H7A0

Right Seat 2, Handle Tube Connecting

1

14 51100-YJR0311-H7A0 Frame Assembly

1

SPECIFICATIONS

43

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts Diagram Figure F
11
Figure F
44

SPECIFICATIONS
1 2 3 4 5 6
7
8 9
10

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts List

Part Number

Description

Qty.

1 16730-YH30110-Q2A0 Fuel Tank Cap

1

2

16641-YBW0110-00A1

Rubber Sleeve, Filling Fuel Hole

1

3 37200-Y5V0110-00A1 Fuel Gauge

1

4 16652-Y9T0110-00A1 Fuel Filter

1

5

16601-Y020120-00A1

Vibration Mount 1, Fuel Tank

4

6 90683-Y020110-00A0 Bushing, White Zinc

4

7 16620-YBW0111-H7A1 Fuel Tank

1

8

16680-Y2P0110-00A1

Fuel Tank Fuel Outlet Subassembly

1

9 90685-D095-0EA0 Clamp, Ø9.5 x 0.8 x 8

1

10

90686-YBW021000M1

Fuel Tube, Ø4.5 x Ø8.5 x 155

1

11 30431-Y020110-00A1 Rubber Sleeve, Fuel Tube 1

SPECIFICATIONS

45

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts Diagram Figure G

SPECIFICATIONS

12

11

10

9 8 7

Figure G

1 23 23 4
5
6

46

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts List

Part Number

Description

Qty.

1 35610-YMR0110-H2A1 Control Panel

1

2 31234-YGK0310-0000 Cover, Push Botton

2

3 35654-YGK0110-0000 Cover, Push Button

2

4 35614-Y020410-0000 Receptacle,13A, 250V

2

5

35614-YMQ0210-0000

Receptacle, 50A, 1000V, Black

1

6

35614-YMQ0110-0000

Receptacle, 50A, 1000V, Red

1

7 35629-Y090110-0000 Grounding Terminal

1

8 35160-YDS0110-0000 Switch Assembly, Engine 1

9

35619-Y110110-0000

Automotive Receptacle, 12V DC

1

10 31234-YBE0110-0000

Circuit Breaker, Push Button, 125/250V_8A

1

11 35632-YMR0110-0000 Intelligauge

1

12

35660HYMR01100000

Wire Harness, Control Panel

1

SPECIFICATIONS

47

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts Diagram Figure H

SPECIFICATIONS

12

3456 7 8 9

16
10 11 12 13 14
15
Figure H

48

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Parts List

Part Number

Description

Qty.

1 51188HYBW0110-H6A0 Left Support, Engine

1

2 51189HYBW0110-H6A0 Right Support, Engine

1

3 50035-YBW0110-00A1 Bracket, Cushion Rubber 1

4

51011HY2P0210-00A0

Vibration Mount, Right, Frame

2

5 90305-0800-31A0

Hexagon Flange Nut, M8, White Zinc

6

6

51009HY2P0110-00A0

Vibration Mount, Left, Frame

2

7

90326-Y2V0110-00A0

Square Nut, M6, White Zinc

6

8 44110HYH30110-L4A0 5in. Wheel, Yellow

2

9

42002-YH30110-03A0

Roll Pin, M8×15, Black Zinc

2

10 17199-YB00110-00A0 Clip Nut, M5, White Zinc 4

11 51143HYBW0111-Q2A1 Plate, Bottom

1

12 51014HYBW0110-00A1 Foot, Rubber

4

13 90001-0616-01A0

Hexagon Flange Bolt, M6 x 16, White Zinc

4

14 51103-YJR0110-H7A0

Reinforcing Plate, Black Zinc

1

15 90001-0612-01A0

Hexagon Flange Bolt, M6 x 12, White Zinc

2

16 90722-Y2P0110-00A1 Plug, End

1

SPECIFICATIONS

49

SPECIFICATIONS

68

50

67

69

27 26 25

24 23 22

50
35 70

48

21

51

20

28

29 30 31 32 33

34

40 41

12

8 See Figure C 9 7
4 56 3

11 12 13 10

19 18 17

16

50

25 35 39

36 37 38

48

49

42 43 44 45 46 47

50

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Engine Parts Diagram Figure B

15 71 14 See Figure D 59
65 66
64

52 60
61 62 63
Figure B

58 6

53

6

54 55

56 57

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Engine Parts List

SPECIFICATIONS

Part Number

Description

Qty.

1 90001-0620-01A0

Hexagon Flange Bolt, M6 x 20, White Zinc

4

2

12410-Z1D0111-00A0

Cylinder Head Cover Subassembly

1

3

12004-Z1D0110-00A0

Cylinder Head Cover Gasket

1

4

11332-Z1D0110-00A0

Gasket, Breath Groove Cover

1

5 11320-Z1D0110-00A0 Piece, Breath

1

6 90001-0612-01A0

Hexagon Flange Bolt, M6 x 12, White Zinc

9

7

12003-Z010110-00A0

Cylinder Head Bolt, M8 x 60, White Zinc

4

8

96003-ZSS2010-0000

Cylinder Head – See Figure C

1

9 30010-Z010110-00A0 Spark Plug, F6RTC

1

10 13200-Z140210-00A9 Piston Ring Assembly

1

11 13122-Z010110-00A0 Piston Pin Clip

2

12 13111-Z950120-00A0 Piston

1

13 13010-Z950110-00A0 Connecting Rod

1

14 90804-Y5Z0210-0001 Stop Block

1

15 17004-Z1D0110-00A0 Tube, Breather

1

16 90502-1114-00A0

Pin, Ø11 x 14

2

17 14071-Z950110-00A0 Valve Lifter

2

18 14081-Z040110-00A0 Valve Tappet

2

19 13121-Z010110-00A0 Piston Pin, Ø18 x Ø54

1

20 90547-6305-00A1

Bearing 1

1

21 13300-Z1D0110-00A1 Crankshaft Assembly

1

22 90547-0205-00A0

Bearing 2

1

23 11001-Z010120-00A0 Crankcase Gasket

1

24 90502-0812-00A0

Pin, Ø8 x 12

4

25 15010-Z010210-Q2A0 Oil Dipstick Subassembly 1

26 11411-Z1D0110-00A0 Crankcase Cover

1

27 90001-0832-01A0

Hexagon Flange Bolt, M8 x 32, White Zinc

6

28 30300-Z1D0210-0000 Starting Motor Assembly 1

29

31112HYH30310-00A0

DC Wire Harness, Battery

1

30 31114HYH30210-00A0 DC Wire Harness, Engine 1

31 90305-0500-31A0

Hexagon Flange Nut, M5,White Zinc

2

32 54066-YE50110-09A0 Wiring Clamp, White Zinc 1

33 30002-Z1D0110-00A0 Magneto Wiring Clamp 1

Part Number

Description

Qty.

34 90001-0520-01A0

Hexagon Flange Bolt, M5 x 20, White Zinc

2

35 90001-0628-01A0

Hexagon Flange Bolt, M6 x 28, White Zinc

4

36 11310-Z1D0110-00A9 Crankcase Subassembly 1

37

90408-Z010510-00A0

Flat Washer, Ø10 x Ø15.8 x 1.5

1

38

90689-Z430211-00A0

Joint, Fuel Tube, White Zinc

1

39 11011HZ1D0210-L4A0 Oil Drain Hose

1

40 30130-Z1D0310-0000 Trigger

1

41 90001-0516-01A0

Hexagon Flange Bolt, M5 x 16, White Zinc

2

42

30120-YMR0210-00A0

Stator Component, Ø152 x 38

1

43 90408-0600-E1A0 Washer, Ø6, White Zinc 3

44 90102-0660-06A0

Hexagon Socket Cap Screw, M6 x 60

3

45 30110-YH30110-00A0 Rotor Component

1

46 19352-Z1D0110-00A0 Cooling Fan, Engine

1

47

13501-Z010110-00A0

Flywheel Nut, M14 x 1.5, White Zinc

1

48

90682-Z010110-00A0

Oil Seal, Ø25 x Ø41.25 x 6

2

49 19309-Z1D0110-00A0 Right Shield, Crankcase 1

50 90001-0616-01A0

Hexagon Flange Bolt, M6 x 16, White Zinc

5

51 14200-Z1D0110-00A9 Camshaft Assembly

1

52 28002-Z1D0210-00A0 Starter Pulley

1

53 28110-Z1D0110-H600 Shroud

1

54 28200-Z1D0410-H600 Recoil Starter Assembly 1

55 90251-0608-03

Bolts and Washer Assembly

3

56 28004-YHX0110-Q200 Guide Plate, Starter Rope 1

57 28210-YEB0110-L400 Handle, Starter Rope

1

58 90684-Z030120-00A0 Clip, 100 mm

2

59

96003-ZSS3010-0000

Carburetor Assembly See Figure D

1

60 17400-Z1D0112-00A0 Air Cleaner, Auxiliary

1

61 90305-0600-31A0

Hexagon Flange Nut, M6, White Zinc

2

62 12081-Z1D0110-00A0 Clamp 1

2

51

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

Part Number

Description

Qty.

63 12510-Z1D0110-00A1 Inlet Pipe

1

64 90001-0625-01A1

Hexagon Flange Bolt, M6 x 25, White Zinc

2

66 17100-Z1D0112-00A1 Air Cleaner

1

65 17151-Z1D0110-0000 Element, Air Cleaner

1

67

37060-Z1D0112-0000

Engine oil Sensor, W/O Nut

1

68

90305-Z010210-01A0

Hexagon Flange Nut, M10, White Zinc

1

69 16675-Z1D0112-00A0 Shield

1

70 30400-Z1D0311-0000 Ignition Coil

1

71 90685-Z120110-00A0 Clamp, Ø14

1

SPECIFICATIONS

52

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Engine Parts Diagram Figure C

SPECIFICATIONS

1

2 34

8 9 10 11

56

Figure C

12

7

13 14

53

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Engine Parts List

Part Number

Description

Qty.

1

14310-Z950110-00A0

Valve Rocker Subassembly

2

2 90001-0612-01A0

Hexagon Flange Bolt, M6 x 12, White Zinc

1

3 12109-Z810110-00A0 Valve Lock Clamp

4

4 12103-Z010110-00A0 Valve Spring

2

5 90203-Z010110-00A0 Stud, M8 x 34, Black Zinc 2

6

12140-Z950310-00A0

Cylinder Head Subassembly

1

7 12121-Z950110-00A0 Exhaust Valve

1

8

14318-Z950110-00A0

Valve Rocker Shaft Subassembly

2

9

12419-Z950311-00A0

Pin Plate, Cylinder Head Cover

1

10 12112-Z810210-00A0 Valve Spring Retainer

2

11 12101-Z810210-00A0 Seal Guide

1

12

90207-Z330210-00A0

Stud, M6 x 105, Black Zinc

2

13 12111-Z950110-00A0 Inlet Valve

1

14 12131-Z950210-00A0 Cylinder Head Gasket

1

SPECIFICATIONS

54

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Engine Parts Diagram Figure D

SPECIFICATIONS

10

11 12

12

3 4 5 67

89
Figure D

55

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
Engine Parts List

Part Number

Description

Qty.

1

16002-Z950110-00A0

Carburetor Insulator Gasket

1

2 16003-Z1D0110-00A0 Carburetor Insulator Plate 1

3 16001-Z010110-00A0 Carburetor Gasket

1

4 16100-Z1D0510-00A1 Carburetor Assembly

1

10 16112-Z010110-0000 Seal Ring, Float

1

16161-Z090510-00A0 Main Jet (H128×0.68)

1

11 16161-Z090410-00A0

Main Jet (H128×0.71), Altitude 3000-6000 Feet

/

16161-Z140310-00A0

Main Jet (H128×0.74), Altitude 6000-8000 Feet

/

12 90681-Z010610-0000 Seal Ring

1

5 16652-Z800110-00A0 Fuel Filter

1

6 90685-D090-0EA0

Clamp, Ø9 x Ø0.8 x 8, Army Green Zinc

1

7

90686-YBW031000M0

Fuel Tube, Ø4.5 x Ø8.5 x 260

1

8 17001-Z1D0110-00A0 Air Cleaner Gasket

1

9 30431-YBW0210-00A1 Rubber Sleeve

1

SPECIFICATIONS

56

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR
TROUBLESHOOTING

TROUBLESHOOTING

Problem Engine will not start.
Engine starts but runs roughly.
Engine will not start wirelessly. Engine will not start electrically. Engine shuts down during operation. Generator cannot supply enough power or overheating. Engine is running but no AC output.

Cause No fuel. Faulty spark plug.
Low oil level.
Spark plug wire loose. EZ Start dial is in “STOP” position. Old fuel or water in fuel. Flooded with fuel.
Choke in the wrong position.
Dirty air filter. Dirty fuel valve. Clogged spark arrestor. Remote control battery is dead. Generator battery is dead. Battery switch is in the OFF position. Generator out of range of remote signal. Obstructions in between generator and remote. Generator battery is dead. Battery switch is in the OFF position. Out of fuel. Low oil level. Clogged spark arrestor. Generator is overloaded. Dirty air filter.
Choke in wrong position.
Poor cord connection. Circuit breaker is open. AC Overload: Button illuminated red. Loose wiring. Other.

Solution Add fuel. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Place generator on a flat, level surface. Attach wire to spark plug. See “Starting the Engine” section. Drain fuel and replace with fresh fuel. Let unit stand for 10 mins. Press choke button until no longer illuminated green. If battery dead, turn choke lever to “RUN” position. Clean or replace air filter. Clean the fuel valve. Clean spark arrestor. Replace remote control battery. Start manually and allow battery to recharge or see “Charge the Battery Section”. Turn battery switch to ON position. Remote must be with 80 feet of generator.
Clear line of site between generator and remote.
Start manually and allow battery to recharge or see “Charge the Battery Section”. Turn battery switch to ON position. Fill fuel tank. Fill crankcase to the proper level. Place generator on a flat, level surface. Clean spark arrestor. Review load and adjust. See “Connecting Electrical Loads.” Clean or replace air filter. Press choke button until no longer illuminated green. If battery dead, turn choke lever to “RUN” position. Check all connections. Reset circuit breaker. Reduce AC load and press Overload Reset Button until illuminated green. Inspect and tighten wiring connections. Contact the help line.

57

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

Problem Engine hunts or falters.

Cause Engine governor defective. Dirty fuel valve. Carburetor is dirty and running lean.
EZ Start dial in wrong position.

Overload.

Repeated circuit breaker tripping.

Faulty power cords or device.

Circuit breaker still too hot.
For other issues and technical support:
Technical Support Team Toll Free +44(0)-1942-715-407 support@championpowerequipment.co.uk

TROUBLESHOOTING
Solution Contact the help line. Clean the fuel valve. Contact the help line. Press choke button until no longer illuminated green. If battery is dead, turn choke lever to the “RUN” position. Review load and adjust. See “Connecting Electrical Loads.” Check for damaged, bare or frayed wires. Replace defective device. Let unit sit for 5 mins.

58

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

TROUBLESHOOTING

UK DECLARATION OF CONFORMITY
We: CHAMPION POWER EQUIPMENT, INC. 12039 SMITH AVENUE, SANTA FE SPRINGS, CA 90670, USA
Hereby declare that the following Appliance complies with the appropriate basic safety and health requirements of the UKCA Directives (see item 3 & 4) based on its design and type, as brought into circulation by us. This declaration relates exclusively to the machinery in the state in which it was placed on the market, and excludes components which are added and/or operations carried out subsequently by the final user. Designation / Function: LOW POWER GENERATORING SETS
1. Type:500987-UK, 500988-UK 2. Serial number: xxxxxxxxxxxxxx(on Dataplate Label and Package)
3. Used harmonized standards: – EN ISO 8528-13:2016
4. Applicable UK Directives: – Supply of Machinery (Safety)Regulations 2008 – Directive (EU) 2016/1628 – Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 – Electrical Equipment (Safety) Regulations 2016 – Electromagnetic Compatibility Regulations 2016

59

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

TROUBLESHOOTING

5. Responsible for documentation: CHAMPION POWER EQUIPMENT, INC. Address: 12039 SMITH AVENUE, SANTA FE SPRINGS, CA 90670, USA
6. Person responsible for compiling the technical files established within the UK Name, Surname: Winch Solutions LTD Address: Unit 17-18 Bradley Trading Estate, Bradley lane, Standish, Greater Manchester, WN6 0XQ, UK
7. Date/Place/Authorized Signature: Aug 11th 2022/HANGZHOU/LI JIE

8. Title of Signatory: GENERAL MANAGER
Note:
The person importing the products becomes responsible for ensuring that they comply with the directives which apply to them. At the very last, it is recommended that the importer obtain a copy of the original Declaration of conformity from manufacturer.

60

500987-UK – 3500W RATED WIRELESS REMOTE START INVERTER GENERATOR

WARRANTY*

WARRANTY*
CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical support please visit: https://www.championpowerequipment.co.uk To complete registration you will need to include a copy of the purchase receipt as proof of original purchase. Proof of purchase is required for warranty service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical components will be free of defects in material and workmanship for a period of three (3) years for domestic usage and One (1) Year for commercial and industrial use. Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This warranty only applies to the original purchaser and is not transferable. For full T&C’s please visit www.championpowerequipment.co.uk.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, CPE will, at its option, authorize evaluation, repair or replacement of the defective part or component at a CPE Service Center. CPE will provide you with a case number for warranty service. Please keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment: Normal Wear Products with mechanical and electrical components need periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole. Installation, Use and Maintenance This warranty will not apply to parts and/or labor if the product is deemed to have been misused, neglected, involved in an accident, abused, loaded beyond the product’s limits, modified,improper servicing installed improperly or connected incorrectly to any electrical component. Normal maintenance is not covered by this

warranty and is not required to be performed at a facility or by a person authorized by CPE.
Other Exclusions
This warranty excludes: ­ Cosmetic defects such as paint, decals stickers, labels, etc.
­ Service or worn items such as oil, spark plugs, spark arrestors, filter elements, piston & rings and O-rings, etc
­ Accessory parts such as starting batteries (After 1 year), hoses, regulators, valves, recoils assemblies and storage covers.
­ Failures due to acts of God and other force majeure events beyond the manufacturer’s control.
­ Problems caused by parts that are not original Champion Power Equipment parts.
When applicable, this warranty does not apply to products used for prime power in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim by anyone from using this product. THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from country to country. This warranty is ONLY written for the GB and terms may be different for any other country.
Contact Information
Winch Solutions ltd Unit 17-18 Bradley Trading Estate Standish WN6 0XQ / UK www.championpowerequipment.co.uk support@cpeeurope.co.uk

61

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CHAMPION POWER EQUIPMENT User Manuals

Related Manuals