SIMKET 10039-3753 MPPT Solar Charge Controller User Manual

June 13, 2024
SIMKET

SIMKET 10039-3753 MPPT Solar Charge Controller

Main Feature The MPPT Solar Charge Controller is designed to efficiently charge batteries using solar power. It features a 3-stage charging mode: constant current (MPPT), constant voltage, and floating. The system voltage can be set to 12/24/36/48V or set to Auto.

Warning and Caution

  • The controllers can only be installed indoors.
  • Installation should be done by qualified professionals.
  • Read all manuals before installation.

Air Circuit Breaker and Wires Requirement

  • Copper wires
  • Air circuit breakers

Wire Connection Sequences It is recommended to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, the same way of connecting wires should be followed.

Installation Steps

  1. Connect the circuit breaker and wires according to the provided diagram.
  2. Follow the wire connection sequences mentioned above.
  3. Set the battery type and system voltage using the LCD display indication (explained further below).
  4. Adjust the parameter settings based on the battery type and system voltage (explained further below).

LCD Display Indication The LCD display provides various menus and options for configuring the charge controller. The following menus are available:

  • Menu1: BAT Volt & Charge Curr
  • Menu2: BAT SOC & Charge KW
  • Menu3: PV Volt & Temp
  • Menu4: BAT Type & SYS Volt
  • Menu5: Load Mode (7H)
  • Menu6: ERROR & Charge State

Battery Type Setting The battery type setting can be adjusted based on the following options:

  1. Battery Type = USE
  2. Battery Type = LI
  3. Battery Type = SEL/GEL/FLD

Parameter Setting The parameter settings depend on the battery type selected. The following parameters can be adjusted:

  1. BAT Type
  2. SYS Volt (auto 12/24/36/48V)
  3. EQU Charge Volt
  4. Load Mode
  5. BAT Charge Volt
  6. FLD Charge Volt
  7. LDV Charge Volt
  8. LRV Charge Volt
  9. BST_R Charge Volt

Press Key Operation The press key operation allows navigation and adjustment of settings. The following keys are used:

  • Function Key: Long Press for System Mode, Short Press for View Mode
  • Operation Key: Long Press for Setting Mode, Short Press forNavigation

Error Code The charge controller may display error codes in case of any issues. The following error codes are defined:

  • E00: No Error
  • E01: Battery over voltage
  • E02: PV over voltage
  • E08: Over-discharge
  • E20: Device over heating

Working Mode The charge controller operates in different working modes based on the code set:

  • Code 3.0: Night mode, no charging
  • Code 4.0: MPPT mode
  • Code 7.0: Absorption mode
  • Code 8.0: Floating mode

Caution! All steps must be carried out when the PV modules are disconnected from the controller.

Batteries Charge Voltage Reference

Battery Type System Volt GEL SEL FLD USE LI
Auto/12/24/36/48 Auto 14.6V 14.8V 14.2V 13.8V 13.2V
12/24/36/48 Auto 14.4V 13.8V 13.2V 11.1V 11.1V

Dimension Please use the provided screws to avoid damage to the internal PCB. Apply proper torque when pushing the screws into the casing to avoid damage to the internal PCB.

Basic Parameter

Item Parameter
Charging mode 3-stage: constant current (MPPT), constant voltage,

floating
System voltage| 12/24/36/48/Auto
Max PV input power| Depends on the specific model and specifications of the charge
controller.

Main Feature

  • 60A MPPT solar charge controller
  • MPPT technology
  • Automatic battery voltage detection for 12V/24V/36V/48V
  • 3-stage charging optimizes battery performance
  • Overcharge protection, over-temperature protection
  • Suitable for battery types such as sealed lead acid, vented gel and lithium battery, etc
  • Easy to be mounted

Warning and Caution

  • Be aware that only qualified professionals could install these controllers. Please read all manuals before installing them.
  • Keep controller away from water. Don’t use wet towel to wipe controller.
  • Keep wiring correct, don’t reverse wiring. Please pay attention to terminal wiring sequence.
  • Keep controller in an environmental temperature from – 20℃~+55℃. Avoid direct sunlight. 4)Keep good heat dissipation.
  • Use the pure copper wires and connect all polarity correctly.
  • The load output is only for DC load less 5A current.
  • Please don’t set any parameters if you are not professional since the controller can work fine in default condition except lithium battery.

Air Circuit Breaker and Wires Requirement

 |
---|---
Copper wires| 6mm²x2PCS
Air circuit breakers| 100A

Wire Connection Sequences

It’s better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it’s same way to connect wires

Installation Steps

  1. The battery voltage should be more than 12V, then the controller can boot up. Install air circuit breaker between controller and batteries. Turn on the circuit breaker, then connect batteries to controller with correct polarity.
  2. Install air circuit breaker between controller and PV modules. Turn on the circuit breaker, and ensure the PV polarity correct, then connect wires between PV modules and controller.
  3. Turn on the air circuit breaker between controller and batteries. 4.Turn on the air circuit breaker between controller and PV modules

LCD Display Indication

SIMKET-10039-3753-MPPT-Solar-Charge-Controller-
FIG- \(2\)

Display IntroductionSIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
\(3\)

Battery Type Setting

System Voltage Setting

Battery Type = USESIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
\(5\)

Battery Type = LISIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
\(6\)

Battery Type = SEL/GEL/FLD

Parameter Setting

Battery Type = USESIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
\(8\)

Battery Type = LISIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
\(9\)

Battery Type = SEL/GEL/FLDSIMKET-10039-3753-MPPT-Solar-Charge-Controller-
FIG- \(10\)

Press Key Operation

SIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
\(11\)

Error Code

SIMKET-10039-3753-MPPT-Solar-Charge-Controller-FIG-
13

Working Mode

Code Working Mode
3.0 Night mode, no charging
4.0 MPPT mode
7.0 Absorption mode
8.0 Floating mode

Manual Setting

Caution! All steps must be carried out when the PV modules are disconnected to controller

Batteries charge voltage reference

SIMKET-10039-3753-MPPT-Solar-Charge-
Controller-FIG- 14

Dimension

Notes: Please use our screws only since it may damage the internal PCB if using other screws. Please use proper torque to push the screws into the casing since it may damage the internal PCB by strong torque.

Basic Parameter

Item Parameter
 
Charging mode 3-stage: constant current(MPPT), constant voltage, floating
System voltage 12/24/36/48/Auto
Max PV input power 720W/12V; 1440W/24V

2160W/36V; 2880W/48V

Max PV input voltage| 180 Voc

Battery voltage automatic recognition

| 12V system (DC8.7V-DC15.5V)

24V system (DC16V-DC31V)

36V system (DC33V-DC41V)

48V system (DC42V-DC64V)

Overcharging protection voltage

| 12V system (16V) 24V system (32V) 36V system (48V) 48V system (64V)
Limited current protection| 61A
Max efficiency| ≥98.1%
PV utilization| ≥99%
Auto Temperature Compensation| -3mV/2V/ºC
Protection Function
Temperature protection| 80℃
Fan-on temperature| >45℃
Fan-o fftemperature| <40℃
Properties
Size (mm)| 214x115x50
Net weight (Kg)| 1.1
Gross weight (Kg)| 1.2
Electromagnetic compatibility| Accord to EN61000, EN55022, En55024
Enclosure| IP21
Environmental temperature| -20℃ ~ +55℃
Storage temperature| -40℃ ~ +75℃

Reminder : The controllers can be installed indoor only