ShelterLogic SQAADD0103C02002710 ShelterTube Wind and Snow Load Rated Garage Instruction Manual

June 4, 2024
ShelterLogic

ShelterLogic SQAADD0103C02002710 ShelterTube Wind and Snow Load Rated

Garage

SAFETY

NOTE: 20′ x 18′ x 10′ is the BASE frame dimension for this length & height. Your model may have more middle ribs than shown in the
illustrations. You will receive one additional rib for every additional 4.5 ft. of building length that you purchase. The basic frame assembly remains the same. The cover will be the correct size for the length of the building you purchased. Approximate Assembly Time: About 4 hours plus 1 hour for every additional 4.5 ft. of building length (10-person assembly).

DANGER : Prior to installation, consult with all local municipal codes regarding installation
of temporary shelters. Choose the location of your shelter carefully. Keep away from electrical wires. Check for overhead utility lines, tree branches or other structures. Check for underground utilities before you place shelter anchorage. Contact your local utilities or dial 811 for utility location services. DO NOT install near roof lines or other structures that could result in excessive accumulation of snow, ice or water onto your structure. DO NOT hang objects other than approved ShelterLogic® Corp. accessories from the roof or support cables.

WARNING : Risk of fire. DO NOT smoke, use open flame or electrical heating devices (including grills, fire pits, deep fryers, smokers or lanterns, radiant heaters etc.) in or around the shelter. DO NOT store flammable liquids (gasoline, kerosene, propane, etc.) in or around your shelter. CAUTION: Use CAUTION when erecting the frame and rib structure. Use proper
tethering and anchoring during build process as denoted in this manual. Use safety goggles during installation. Secure and bolt together overhead poles during assembly. Be aware of exposed pole ends.

TOOLS

PROPER ANCHORING AND INSTALLATION OF FRAME

PROPER ANCHORING OF THE FRAME IS THE RESPONSIBILITY OF THE CONSUMER
Any shelter that is not anchored securely has the potential to be blown away or collapse, resulting in damage or bodily injury. Periodically check the anchors to ensure stability of the shelter. ShelterLogic® Corp. is not responsible for any shelter that blows away or collapses. NOTE: If strong winds or severe weather is forecast in your area, we recommend removal of the cover. The shelter cover can be quickly removed and stored prior to severe weather conditions. Failure to follow the guidelines may result in denial of warranty claims. Check for underground utilities before you begin anchor installation. Contact your local utilities or dial 811 for utility location services.

REPLACEMENT PARTS, ASSEMBLY, and SPECIAL ORDERS:

Genuine ShelterLogic Corp. replacement parts and accessories are available from the factory, including anchoring kits for nearly any application, replacement covers, wall and enclosure kits, vent kits, light kits, frame parts, zippered doors and other accessories. All items are shipped factory direct to your door.

QUESTIONS – CLAIMS – REPLACEMENT PARTS? CALL OUR CUSTOMER SERVICE HOTLINE:
U.S.A: 1-800-524-9970 INTERNATIONAL: 001-860-945-6442
CANADA: 1-800-559-6175 U.S.A. HOURS OF OPERATION: MON-FRI 8:00AM-8:00PM ET, SAT-SUN 8:00AM-4:30PM ET.

CARE AND CLEANING

A tight cover ensures longer life and performance. Always maintain a tight cover. Loose fabric can accelerate deterioration of cover fabric. Immediately remove any accumulated snow or ice from the roof structure with a broom, mop or other soft-sided instrument. Use extreme caution when removing snow and ice from coveralways remove snow and ice from outside the structure. DO NOT use hard-edged tools or instruments like rakes or shovels to remove snow. This could result in punctures to the cover. DO NOT use bleach or harsh abrasive products to clean the fabric cover. Cover is easily cleaned with mild soap and water. Failure to follow these guidelines may result in denial of warranty claims.

PLEASE VISIT WWW.SHELTERLOGIC.COM OR CALL800-932-9344 FOR SPECIFIC DETAILS.

WARRANTY

ShelterLogic® Corp. provides a limited warranty through the designated Limited Warranty period that this product, components, hardware and parts are free from manufacturer’s defect. This warranty is extended to the original purchaser of the structure and may not be transferred. The Limited Warranty Period varies based on the product purchased. The table below outlines the coverage for various product types and associated hardware. The start of the warranty period is determined by the date of shipment from ShelterLogic® Corp. for all factory direct purchases or the date of purchase for any product obtained from an authorized reseller. Claims for products purchased from an authorized reseller must be include a copy of the original receipt. If this product or any associated parts are found to be defective or missing at the time of receipt, ShelterLogic® Corp. will repair or replace, at its option, the product, defective parts or missing parts at no charge to the original purchaser. The replaced or repaired parts shall be covered for the remainder of the Limited Warranty Period. All shipping costs for these parts are the responsibility of the customer. All products must be returned in the original packaging where possible. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

WARRANTY COVERAGE PERIOD OVERVIEW

  • Product

  • Heavy Duty Fire Rated Fabric Roof Cover

  • Ultra Duty Fire Rated Fabric Roof Cover

  • Heavy Duty Fire Rated Fabric End Panels

  • Ultra Duty Fire Rated Fabric End Panels

  • Standard Duty Fabric Cover & End Panels

  • Steel Frame

  • Hardware and Accessories

  • Term

  • 10 Years Prorated,

  • Year 1 Full Repair or Replacement

  • 15 Years Prorated, Year

  • 1 Full Repair or Replacement

  • 3 Years Prorated, Year

  • 1 Full Repair or Replacement

  • 3 Years Prorated, Year

  • 1 Full Repair or Replacement

  • 1 Year, Full Repair or Replacement

IMPORTANT TIPS

  • Select and Prepare Your Building Site:
  • Building MUST be located on a FLAT and LEVEL surface with good drainage.
  • For best results, erect building upon a concrete pad
  • Allow enough working space so it is not difficult to move parts into position for assembly. Also, there needs to be enough space outside the building to be able to fasten screws from the outside.
  • Before assembling any parts, your base should be constructed and an anchoring system should be ready to use.
  •  Watch the Weather Closely: Be sure the day you choose to install your building is dry and calm.
  • Do NOT attempt to assemble your building on a windy day. Be careful on wet or muddy ground.

INSTALLATION

NOTE : 20′ x 18′ x 10′ is the BASE frame dimension for this length & height. Your model may have more middle ribs than shown in the illustrations. You will receive one additional rib for every additional 4.5 ft. of building length that you purchase. The basic frame assembly remains the same. The cover will be the correct size for the length of the building you purchased. Approximate Assembly Time: About 4 hours plus 1 hour for every additional 4.5 ft. of building length (10-person assembly).
NOTE : 20′ x 18′ x 10′ is the BASE frame dimension for this length & height. Your model may have more middle ribs than shown in the illustrations. You will receive one additional rib for every additional 4.5 ft. of building length that you purchase. The basic frame assembly remains the same. The cover will be the correct size for the length of the building you purchased. Approximate Assembly Time: About 4 hours plus 1 hour for every additional 4.5 ft. of building length (10-person assembly).
Ensure frame is square before continuing: Building MUST be located on a FLAT and LEVEL surface!
NOTE : 20′ x 18′ x 10′ is the BASE frame dimension for this length & height. Your model may have more middle ribs than shown in the illustrations (A = your building’s length). The diagonal measurements (X and Y) should be about equal to within appoximately 1 inch.
NOTE : 20′ x 18′ x 10′ is the BASE frame dimension for this length & height. Your model may have more middle ribs than shown in the illustrations. You will receive one
additional rib for every additional 4.5 ft. of building length that you purchase. The basic frame assembly remains the same. The cover will be the correct size for the length of the building you purchased. Approximate Assembly Time: About 4 hours plus 1 hour for every additional 4.5 ft. of building length (10-person assembly).
To ensure longer cover life, check and retighten the cover every month.

150 Callender Road • Watertown, CT 06795www.ShelterLogicGroup.com
WWW.SHELTERLOGIC.COM OU APPELER AU 800 932-9344.

Documents / Resources

| ShelterLogic SQAADD0103C02002710 ShelterTube Wind and Snow Load Rated Garage [pdf] Instruction Manual
SQAADD0103C02002710, ShelterTube Wind and Snow Load Rated Garage, SQAADD0103C02002710 ShelterTube Wind and Snow Load Rated Garage
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals