Gooxi RMC4236-670-HSE Hot Swap Hdds 4u Rackmount Server User Manual
- June 13, 2024
- Gooxi
Table of Contents
RMC4136-670-HSE
User’s Manual
Version 1.0
FOREWORD
This manual is writing for the installation and usage information of
RMC4236-670-HSE chassis that provided to professional system integrators and
personal computer technicians. The installation and maintenance should be
conducted by experienced technicians only.
Gooxi RMC4236-670-HSE, the fourth generation of server chassis is designed
based on standard 2U server and can be assembled into common computing server,
storage server, servers in Internet cafe, database server, VOD storage server,
HPC server, and so on. The server chassis is different from ordinary desktop
chassis that pays more attention to appearance design, as it focuses on the
quality and content. Gooxi RMC4236-670-HSE server chassis uses imported first-
class SGCC galvanized steel, and possessed with the characteristics of
fingerprint resistance, corrosion resistance, heat resistance, heat transfer
and thermal reflectivity, formability as well as weldability.
In addition, taking into account the higher stability requirements of the
server during usage, Gooxi RMC4236-670-HSE server chassis has excellent heat
dispersion. To be specific, the heat dissipation channel is reasonably
designed, which can take away a large amount of heat in the chassis to ensure
the stable operation of the server.
The scalability is an important factor to determine whether the server chassis
design is reasonable. Gooxi RMC4236-670-HSE server chassis has stronger
scalability than ordinary chassis, such as: hard disk expansion, peripheral
expansion, etc.
Chapter 1 Chassis Overview
1.1 Chassis Structure
- Top cover
- Rear window
- Ventilation wall
- Backplane
- Hard disk module
- Base
- Hard disk box
- Left-side ear
- Right-side ear
1.2 Rear Window Construction
- Power site
- I/O washer position
- Expansion slot
1.3 Materials Package
- 144 pieces of #6-32*5mm countersunk screws are used for fixing hard disks.
- 10 pieces of active studs with the total height of 8mm are used to install the motherboard.
- 16 pieces of #6-32*6mm cross recessed pan head screws are used for fastening the motherboard and power supply.
- 0~35 SAS – label.
- One 100 120 0.045mm PE valve bag.
1.4 Chassis View
Front view:
Rear view:
1.5 Related LEDs of Chassis Panel
The above picture shows the front panel buttons and LEDs; each button or LED has its own function and status description that are described in the following table:
| LED Status Description
---|---
No.| Picture| LED Appearance| Description
1| | LOGO blue LED is on| The device is on
②| | The green LED is on| The device is on
③| | Reset| The button is used to reset the server
④| | The green LED flashes| The system is running normally
⑤| | The yellow LED is on| Alarm indication, including system alarm, fan
alarm, power alarm, etc.; the specific can be viewed via IPMI management
software
⑥| | The green LED is on| LAN Port1 connection is normal
⑦| | The green light is on| LAN Port2 connection is normal
⑧| | USB interface| 2* USB2.0 interface
1.6 Introduction to Hard Disk LED
- Act LED
- Fault LED
- Status LED
- LED description is as follows:
Function | Act LED | Fault LED | Status LED |
---|---|---|---|
Hard disk in place | ON | OFF | OFF |
Hard disk activity | Flash 4Hz/s | OFF | OFF |
Hard disk positioning | ON | Flash 4Hz/s | OFF |
Hard disk error | ON | OFF | ON |
RAID rebuilt | ON | OFF | Flash 1Hz/s |
1.7 Introduction to Backplane
The standard configuration of Gooxi backplane models are RMC4124-BPE-12G and
RMC2112-BPE-12G, and the specific description is as follows:
RMC4124-BPE-12G
Corresponding site| Interface / jumper / slot| Corresponding site| Interface /
jumper / slot
1, 2, 3, 4, 5| 5 ATX power input| 10| PMC PM8044 Expander chip
6, 7, 8, 9| 4 4PIN temperature controlled fan socket| 11, 12, 13| SFF-8643
12Gb SAS input interface
| | |
RMC2112-BPE-12G
Corresponding site| Interface / jumper / slot| Corresponding site| Interface /
jumper / slot
1, 2, 3| 3 ATX power input| 11| PMC PM8043 Expander chip
4, 5, 6, 7| 4 Sockets of 4PIN temperature controlled fan| 8, 9, 10| SFF-8643
12Gb SAS input interface
| | |
1.8 Introduction to the Output Interface of Backplane Hard Disk
Front-built 24-bay Expander backplane order:
Back-built 12-bay Expander backplane order:
1.9 Internal Expander Backplane Connection Diagram of Chassis
Chapter 2 Easy Installation Instruction
2.1 Introduction to the Disassemble Steps of Gooxi4136 Chassis Upper Cover
- Unscrew the upper cover screws
- Press the button of chassis back cover
- Push the back cover
- Pull the back cover up
2.2 Introduction to the Installation Steps of Gooxi4136 Chassis Fan Module
-
Install the shock-proof soft nails into the fan.
-
Install four 8038 fans in the fan module brackets respectively.
-
Figure of the finished installed fans
-
Install the two fan modules in the chassis respectively.
-
Figure of the finished installed fan modules.
2.3 Introduction to the Insert and Plug Steps of Gooxi4136 Chassis Hard Disk
-
Press the button to pull out the hard disk from the hard disk bay.
-
Install the 3.5-inch hard drive to the hard drive bracket according to screw holes, as shown in the figure below.
-
The installed hard disk is shown in the following figure:
-
Insert hard disk to the chassis, and close the switch. As shown in the following figure.
2.4 Introduction to the Installation Steps of Gooxi4136 Chassis Power Supply
-
Place the power supply case to the chassis according to the hole site, as shown in the figure below.
-
Fix the power supply bracket, and screw on the screws at the position marked in the figure below.
-
Push the whole base (including rear window and power supply case) into the chassis and fix the screws.
-
Figure of the installed power supply case.
-
Insert the hot-swap power modules PSU1 and PSU2 respectively
-
The final installed figure of power supply
2.5 Introduction to the Installation Steps of Motherboard on Gooxi4136 Chassis
-
Open the chassis, and place insulation pad based on the correct orientation, based on the hole of motherboard screw, motherboard active studs (8mm height) installed at the corresponding position on the insulation pad. As shown in the figure below: Install Gooxi G1DE-4B dual-socket motherboard corresponding to the base hole sites.
-
After the motherboard active studs (8mm height) installed, place the motherboard into the chassis and fasten motherboard screws at the hole sites. As shown in the figure below:
2.6 Introduction to Installation Steps of Rear Hard Disk on Gooxi4136 Chassis
-
Dismantle the chassis base and remove the hard disk SEALING PLUG at rear window 2.5 module. (dummy module)
-
2.5-inch hot-swap hard drive module is installed and locked to the chassis base with screws, as shown in the figure below:
-
Figure of 2.5-inch hot-swap hard disk module locked screws
-
Push the entire base (including 2.5-inch hard drive module) into the chassis, and fix the base and rear window screw.
-
Figure of finished installation of 2.5-inch hot-swap hard drive module
-
Install two 2.5-inch hard drives on the hard disk case respectively
-
Insert two 2.5-inch hard drives into the rear hard disk module respectively
-
The completed installation figure is as follows:
Note: If the Customer selects two optional 2.5-inch hot-swap hard drives, then Gooxi-selected CRPS power must be equipped with.
Chapter 3 Chassis Parameters
Basic Parameters
Chassis model| Rackmount
Chassis structure| 4U
Applicable motherboard| EEB(1213)/CEB(1210.5)/ATX(129.5)/Micro ATX
Supported motherboard brands| Gooxi, Intel, ASUS, SuperMicro, TYAN, MSI,
GIGABYTE, etc
Power type| Single charge and 1+1 redundant power
No. of supported power supplies| 1
SGPIO| Support
Backplane| 12Gb/s SASE expander backplane
Supported hot-swap hard drives| Supportive, compatible with SAS and SATA
drives
Supported hot-swap hard fans| Support
Hard driver bay| Thirty-six 3.5-inch (or 2.5-inch) hot-swap hard disk bays;
and two 2.5-inch rear hot-swap bays
CD driver site| None
Hard disk shockproof| Hard disk bracket is designed with EMI spring. The
unique shockproof fan design can reduce the resonance between the fan and hard
disk without affecting the reading and writing speed of hard disks.
Cooling system| Eight 8038 fans
Intelligent temperature control| Support
Expanded card slots| 7 full-height PCI or PCI-E expansion card slots
Slide guide rails| Optional
Apparent Parameters
Front panel interface| 1 switch key, 1 restart key, 1 fan alarm indicator, 1
hard disk indicator and 2 network indicators
Screws-free dismantle| Support
Fixed mode of cabinet| Ordinary
Configuration Parameters
Product material| Imported SGCC (galvanized steel sheet), ABS panel and
punching net
Chassis dimension| 670433177mm(Depth Width Height)
Chassis weight| 19kg
Package dimension| 885585323mm(Depth Width * Height)
Overall gross weight| 23kg
Safety certification| CE, FCC, RoHS
Note: This manual is a general instruction of RMC4136-670-HSE series. Specific parameters of each type please refer to the chassis detailed parameters.
Shenzhen Gooxi Information Security Co., Ltd.
Documents / Resources
|
Gooxi RMC4236-670-HSE Hot Swap Hdds 4u Rackmount
Server
[pdf] User Manual
RMC4236-670-HSE Hot Swap Hdds 4u Rackmount Server, RMC4236-670-HSE, Hot Swap
Hdds 4u Rackmount Server, Rackmount Server, Server
---|---
Read User Manual Online (PDF format)