Soundoffsignal EXFS10002 Flush Mount Light Instruction Manual
- June 13, 2024
- Soundoffsignal
Table of Contents
Soundoffsignal EXFS10002 Flush Mount Light Instruction Manual
Single Color
EXFS10001-
R RED EXFS10001-
B BLUE EXFS10001-
A AMBER EXFS10001 -W WHITE
Dual Color
EXFS10002
-F AMBER/WHITE EXFS10002-
M BLUE/AMBER EXFS10002-
E BLUE/WHITE EXFS10002-
P GREEN/AMBER EXFS10002-
K RED/AMBER EXFS10002-J
RED/BLUE EXFS10002-
D RED/WHITE
- HIGH CURRENT interconnects must be properly terminated. Poor crimp quality can cause heat build-up and fire. Follow the crimp connector manufacturer
- DO NOT install this product or route any wires in the Air Bag Deployment Refer to vehicle Owner’s Manual for deployment zones.
- Do NOT use system to disconnect headlights, brake lights or other safety
- Unit may become hot to touch during normal operation.
- Failure to properly install connectors, fuses or wiring may cause vehicle failure or fire.
- Installation must only be performed by trained technician. Installer must determine vehicle wiring configuration and proper integration of
- Use proper wire gauge. All power wires connecting to positive (+) or negative (-) battery terminal or local chassis ground (-) must be sized to supply at least 125% of current and properly fused at power source.
- Install protective grommets when routing wire through firewall or Petroleum/silicone based lubricants will cause the silicone lens to discolor
DIMENSIONS / TECHNICAL SPECIFICATIONS . . . 2 LIGHT INSTALLATION 3
ELECTRICAL INSTALLATION / INFORMATION . . . 4 – 7 WARRANTY INFORMATION 8
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices. _Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy _for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/tech-services/returns/ . If you have questions regarding this product, contact Technical Services , Monday – Friday, 8 a.m. to 5 p.m. ET at 1.800.338.7337 (press #4). Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsignal.com.
XF LIGHT DIMENSIONS / SPECIFICATIONS
TECHNICAL SPECIFICATIONS
| Input Voltage:| 9-32Vdc
Average
Power
| 9.7 Watts| Max
Power
| 19.4
Watts
12Vdc| 24Vdc
Dual Color Version Current
Consumption
| Peak Current| Average Current| Peak Current| Average
Current
Red| 0.6| 0.3| 0.3| 0.15
Blue, Amber
White, Green
| 0.8| 0.4| 0.4| 0.2
Single Color Version Current
Consumption
| Peak Current| Average Current| Peak Current| Average
Current
Red| 1.2| 0.6| 0.6| 0.3
Blue, Amber
White, Green
| 1.6| 0.8| 0.8| 0.4
LED Count| 6
Number of Flash Patterns| 20
Sync| Sync 2 , Up to 24 lights
bluePrint Compatible
Operating Temperature| -40°C to +65°C
IP Rating| IP67
Certifications
| SAE J595 Class1, CA Title ECE 13 Class B XR2
R65 XA2, XB2,
ECE (single color) XR1
R65 XA1, XB1,
ECE (dual color) 3
R10, CISPR25 Class
XF LIGHT WIRE INFORMATION
WIRE HOOK-UP TABLE
WIRE COLOR:| FUNCTION:
24 AWG RED| Power (Primary)
24 AWG BLACK| Ground
24 AWG GREEN*| Sync2
24 AWG WHITE to
GROUND
| Setup Wire (See page 5*)
24 AWG WHITE to POWER| Function Wire
24 AWG YELLOW| Power (Secondary)
- Sync2. Up to 24 light heads.
**To sync multiple XF lights, connect the Green wire from each light together
XF LIGHT INSTALLATION
Gasket Mount (FIG. 1)
- Ensure surface is flat and space behind mounting surface is open and free of obstacles.
- Choose mounting location and drill a 1 1/8″
- Place Gasket into hole and ensure fit is Confirm the gasket and light head is placed with the arrows aligned vertically as shown in Fig. 1.
- Make wire connection and feed wire through the drilled wire hole.
- Slide the light into the gasket making sure to keep gasket on the mountin
PRO TIP: If hole is slightly too large light may spin under certain
circumstances. Apply a small amount of Silicon on back side of light to ensure
light is solid.
NOTE: WRONG MOUNTING ORIENTATION WILL NOT MEET SAE OR ECE R65 REQUIREMENT
ELECTRICAL INSTRUCTIONS:
SYNC 2
Synchronizing the flashing of multiple light modules is accomplished by connecting the Green wires of different light modules together. Up to 24 light modules can be connected for synchronized flashing. All light module flash patterns must be set to the same flash pattern # to ensure proper operation. Refer to the Sequence Type section in Set-Up Table (page 5) to setup light modules to flash in alternate or simultaneous flash pattern.
FLASH PATTERNS
PATTERN #| SINGLE COLOR| DUAL COLOR
1| ECE Single
2| ECE Double
3| ECE Triple
4| QUINT
5| WARP
6| INTER-CYCLE
7| DOUBLE
8| QUAD
9| POWER PULSE
10| ROAD RUNNER
11| Q-SWITCH
12| STEADY-BURN / ROADRUNNER (SEQUENCE TYPE 1: STEADY BURN,
SEQUENCE TYPE 2: ROADRUNNER)
13| STEADY-BURN DRIVER TITLE 13 QUAD (SEQUENCE TYPE 1: STEADY BURN,
SEQUENCE TYPE 2: TITLE 13 QUAD)
14| QUAD 2
15| DOUBLE 2
16| RANDOM 1
17| RANDOM 2
18| Quad Pulse-Pop
19| Cruise; 3% DC
20| Steady ON; 40% DC
ADVANCE PATTERN
Flash pattern can only be changed when the light head is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >250mS and <1S (light will go steady high) then release. The flash pattern will advance to the next pattern. If the light module was at the last pattern, the pat- tern will reset to the 1st pattern.
BACKUP PATTERN
This function is only valid when the light head is in a flash- ing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >1S and < 2S (light will go steady high, steady low) then release. The flash pattern will backup to the previ- ous pattern. If the light module was at the first pattern, the pattern will change to the last pattern on the list.
COLOR SWAP
This function is only valid for dual color light heads and can only be changed when the light is in a flashing mode (disabled for single color light heads and when light head is operating in cruise or steady ON functions). When the light head is flashing, momentarily connect the white wire to ground for >2S and <3S (light will go steady high, steady low, off) then release. The light head will switch between Color Swap OFF and Color Swap ON. When Color Swap is OFF, the 1st color will flash 1st on a dual color pattern. When Color Swap is ON, the 2nd color will flash 1st on a dual color pattern.
SIMULTANEOUS/ALTERNATE
This function can only be changed when the light head is in a flashing mode
(disabled in cruise or steady ON functions) and only has an effect when at
least 2 LED light heads have the green sync wire connected together. When the
light is flashing, momentarily connect the white wire to ground for >3S and
<4S (light will go steady high, steady low, off, steady high) then release.
The light head will switch between Simultaneous and Alternate each time this
sequence is done. To have light heads flash simultaneously, both light heads
need to be set to the same sequence type (Set-Up Table). To have light modules
flash alternately, the light heads need to be set to different sequence types
(Set-Up Table).
PATTERN RESET
This function is only valid when the light head is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >5S and <6S (light will go steady high, steady low, off, steady high, steady low, off) then release. The flash pattern will reset to the 1st pattern in the list.
FACTORY RESET
This function is only valid when the light head is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white wire to ground for >6S and <7S (light will go steady high, steady low, off, steady high, steady low, off, steady high) then release. The LED module will reset to: pattern=1, Function Table=1, Color Swap=OFF, Simultaneous.
LOCKOUT CONFIGURATION WIRE
This function will disable the wire tap configuration mode that is activated by holding the white wire to ground. The lock out is activated by applying ground to the white wire for >7 seconds and <8 seconds per the table below. The function can be disabled by tapping the wire to ground and releasing 8 times within 5 seconds. The light will flash 8 times when the feature is enabled or disabled to notify the user of a setting change
SETUP TABLE
SECONDS| USER INTERFACE
FROM| TO| VISUAL FEEDBACK| ACTION TAKEN
0| 1| STEADY-HIGH (60%)| FORWARD ONE PATTERN
1| 2| STEADY-LOW (30%)| BACKWARD ONE PATTERN
2| 3| OFF| COLOR SWAP (OFF OR ON )
3| 4| STEADY – HIGH (60%)| SEQUENCE TYPE: SIMULTANEOUS OR ALTERNATE
4| 5| STEADY – LOW (30%)| CHANGE FUNCTION TABLE (SEE PAGE 6)
5| 6| OFF| RESET TO PATTERN 1
6| 7| STEADY-HIGH (60%)| FACTORY RESET (PATTERN 1, COLOR SWAP: OFF,
SIMULTANEOUS)
7| 8| STEADY – LOW (30%)| LOCK OUT WHITE CONFIGURATION WIRE
If held longer than 8 seconds, the light will go back to flashing the current
pattern and no action will be taken.
5
FUNCTION TABLES
Changing the function table is only enabled when the light head is in a flashing mode (disabled in cruise or steady ON functions.) The functional operation of the light head can be changed while applying the +V to the Red wire with the black wire connected to ground. When the light is flashing, momentarily connect the White wire to ground for >4S and <5S (light will go steady high, steady low, off, steady high, steady low) then release. The function table will now advance to the next table (table 1 to table 2, table 2 to table 3, or table 3 to table 1. Repeat above process until required function table is active. AFTER SELECTION: The light will “wink” to indicate which of the new tables is selected.
FUNCTION TABLE 1
WIRE| LIGHT
RED| YELLOW| WHITE| SINGLE| DUAL
+9-32V| | | FLASH| FLASH DUAL
| +9-32V| | CRUISE| STEADY CLR 2
+9-32V| +9-32V| | FLASH| STEADY CLR 2
| | +9-32V| NO OP| NO OP
+9-32V| | +9-32V| LOW PWR FLASH*| FLASH CLR 1
| +9-32V| +9-32V| CRUISE| FLASH CLR 2
+9-32V| +9-32V| +9-32V| LOW PWR FLASH| FLASH DUAL
FUNCTION TABLE 2
WIRE| LIGHT
RED| YELLOW| WHITE| SINGLE| DUAL
+9-32V| | | FLASH| FLASH CLR 1
| +9-32V| | STEADY CLR 1| STEADY CLR 2
+9-32V| +9-32V| | STEADY CLR 1| STEADY CLR 2
| | +9-32V| NO OP| NO OP
+9-32V| | +9-32V| CRUISE| FLASH DUAL
| +9-32V| +9-32V| STEADY CLR 1| STEADY CLR 2
+9-32V| +9-32V| +9-32V| STEADY CLR 1| STEADY CLR 2
FUNCTION TABLE 3
WIRE| LIGHT
RED| YELLOW| WHITE| SINGLE| DUAL
+9-32V| | | FLASH| FLASH DUAL
| +9-32V| | FLASH LOW PWR*| FLASH DUAL
LOW PWR
+9-32V| +9-32V| | FLASH LOW PWR*| FLASH DUAL
LOW PWR
| | +9-32V| NO OP| NO OP
+9-32V| | +9-32V| FLASH LOW PWR*| FLASH DUAL
LOW PWR
| +9-32V| +9-32V| FLASH LOW PWR*| FLASH DUAL
LOW PWR
+9-32V| +9-32V| +9-32V| FLASH LOW PWR*| FLASH DUAL LOW PWR
REMOTE MODE: FOR USE WITH bluePRINT SYSTEM ONLY
Connecting the Green wire to ground before applying power to the Red or Yellow
wires will place the LED module into remote mode and the light output color
will be directly controlled by the input wires as shown below
For Cruise mode or Low Power control of the LED module, the signal to the
control wires must be 100 +/- 2Hz using the duty cycle inputs listed below to
produce the light output.
XF Light Remote Mode Functionality
Red Wire| Yellow Wire| Single Color| Dual Color
Color Swap=OFF| Color Swap=ON| Color Swap=OFF| Color
Swap=ON
Cruise| –| Cruise Color 1| | Cruise Color 1| Cruise Color 2
–| Cruise| | | Cruise Color 2| Cruise Color 1
Cruise| Cruise| | | Cruise Color 2| Cruise Color 1
Flash| –| Flash Color 1| | Flash Color 1| Flash Color 2
–| Flash| | | Flash Color 2| Flash Color 1
Flash| Flash| | | Flash Color 2| Flash Color 1
Steady ON| –| Steady ON Color 1| | Steady ON Color 1| Steady ON Color 2
–| Steady ON| | | Steady ON Color 2| Steady ON Color 1
Steady ON| Steady ON| | | Steady ON Color 2| Steady ON Color 1
Cruise Mode Duty Cycle (@ 100Hz)
Input| Light Output
40%| OFF
50%| 3%
60%| 7%
Low Power Flash D.C. (@ 100Hz)
Input| Light Output
70%| 30%
80%| 40%
90%| 50%
WARRANTY & RETURN GOODS PROCEDURE
CLEANING & CARE OF YOUR LIGHTBAR:
Keeping the lenses clean and scratch free will optimize the performance of the product. The exterior of the product including lenses should be cleaned with mild soapy water and a soft cotton cloth to remove dirt, grime and insects. Never use window cleaners or harsh chemicals on the lenses; this may cause failure of the lenses or reduce clarity resulting in the reduction of light output.
MOUNTING INTEGRITY:
A review of bolt/hardware/mounting bracket integrity should be performed at the beginning and end of each shift.
WARNING MESSAGES – PLEASE READ:
WARNING – CARE MUST BE TAKEN WHEN DRILLING THROUGH THE ROOF OF THE
VEHICLE NOT TO DRILL INTO ANY EXISTING WIRING AND NOT TO DRILL THROUGH THE
HEADLINER OR SUPPORT MEMBERS OF THE VEHICLE. CHECK BOTH SIDES OF THE MOUNTING
SERVICE PRIOR TO DRILLING. DE-BURR ANY HOLES AND REMOVE ANY METAL SHARDS OR
REMNANTS. INSTALL GROMMETS INTO ALL WIRE PASSAGE HOLES.1
WARNING – ROUTE WIRES ONLY IN LOCATIONS THAT ARE NOT SUBJECTED TO
POTENTIAL WEAR. MAKE SURE TO AVOID ROUTING WIRES IN THE DEPLOYMENT AREA OF
YOUR AIR BAG. REFER TO YOUR VEHICLE OWNER’S MANUAL FOR AIR BAG DEPLOYMENT
ZONES.
WARNING – ALL CUSTOMER SUPPLIED POWER WIRES CONNECTING TO THE POSITIVE
(+) OR NEGATIVE (-) BATTERY TERMINAL OR LOCAL CHASSIS GROUND (-) MUST BE SIZED
TO SUPPLY AT LEAST 125% OF THE MAXIMUM CURRENT AND PROPERLY FUSED AT THE POWER
SOURCE WITH APPROPRIATELY RATED FUSE.
WARRANTY RETURN PROCESS:
Please scan QR code or visit https://soundoffsignal.com/support-
page/returns/.
Alternatively contact your SoundOff Signal Sales Representative, Customer
Services staff or our Technical Department (800.338.7337) for a RMA #, Return
Merchandise Authorization Number.
The following information is required for issuance of the RMA #:
-
Reason for returning the product*
-
Address where replacement product is to be shipped*
-
Telephone number where you may be reached*
-
SoundOff Signal invoice number on which product was purchased**
-
SoundOff Signal part number and serial number**
-
E-mail address where RMA # should be e-mailed**
-
Fax number where RMA # should be faxed**
-
RMA # will not be given without this information.** If available, please provide this information.
SoundOff Signal will NOT accept returns without an RMA #. Each RMA # is good for only one (1) return and will expire (30) days after the date it was issued. Products must be shipped back to SoundOff Signal and the RMA # clearly marked on the outside of the package near the shipping label. Please use the following address on your shipping label:
SoundOff Signal
ATTN: RMA # / Technical Services 3900 Central Parkwa
Hudsonville, MI 49426
WARRANTY EXCLUSIONS:
Shipping & Handling, labor and service fees are non-refundable. SoundOff Signal is not liable for any damage due to installation or personal injury as a result of using SoundOff Signal product.
WARRANTY FORFEITURE:
Warranty will not be granted if the Warranty Return Policy & Procedure rules
are not strictly followed. Physical damage resulting from customer abuse will
void warranty. Warranty will also be voided if any SoundOff Signal and/or
manufacturer serial tags, product stickers, seals, or the like, are removed,
altered or tampered with. Returned product that is damaged by shipping via the
RMA # procedure is not the responsibility of SoundOff Signal.
Document effective date on cover and below supersedes previously dated
policies and statements.
There are no other warranties, expressed or implied, including, but not
limited to, any implied merchantability or fitness for a particular use.
SoundOff Signal reserves the right to modify this warranty statement at any
time; or to discontinue, modify, or upgrade any products of its manufacture
with design improvements without prior notice.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>