Allied BCE5V Compact Air Handler Instruction Manual
- June 13, 2024
- Allied
Table of Contents
Allied BCE5V Compact Air Handler
Product Information
The BCE5V Compact Air Handler is a blower coil unit designed for installation in homes. It features a compact cabinet and includes coils and various components for efficient operation. The product is part of the 5 Series with enhanced features and is available in multiple models with different tonnage options.The BCE5V Compact Air Handler comes with a 10-year limited warranty on all parts, with the option to extend the warranty. To qualify for the 10-year coverage, the warranty must be registered online within 60 days of installation. Unregistered equipment defaults to a 5-year coverage. For more details on the warranty terms, conditions, and exclusions, please visit www.alliedair.com.
Product Usage Instructions
To install the BCE5V Compact Air Handler, follow these
steps:
- Ensure that the installation clearances are met. The cabinet requires no clearance, and the unit should be positioned with 0 inches clearance to the plenum, outlet duct within 3 feet, and floor. Refer to the user manual for additional clearance requirements.
- Select the appropriate accessories based on your installation requirements. The available accessories include the Downflow Kit, Horizontal Support Frame kit, Side Return Unit Stand (upflow only), Single Point Power Kit, Wall Hanging Bracket Kit (upflow only), and High Performance Economizer (Commercial Only). Refer to the user manual for compatibility information.
- If electric heat is required, choose the appropriate Electric Heat Kit with Terminal Block or Electric Heat Kit with Circuit Breaker based on the desired heating capacity. Refer to the user manual for size and model compatibility.
- Install the selected accessories as per the provided instructions.
- Connect the refrigerant lines to the suction and liquid ports as specified in the user manual. Ensure the correct size of the installed TXV (Thermal Expansion Valve) is used.
- Connect the unit to the power supply. The voltage requirement for the BCE5V Compact Air Handler is 208-230V, 1 phase, and 60Hz.
- Perform any necessary service or maintenance following the guidelines provided in the user manual.
For any further assistance or information on AHRI system matches, please visit www.alliedratings.com or www.AHRIdirectory.org.
APPLICATION
- 1 1/2 – 5 ton systems
- Sequenced for demand management
- External access to heater circuit breakers
INSTALLATION
- 1 piece design
- Smaller profile for tight application areas
- Multiposition – Factory ready for upflow, downflow, and horizontal left/right applications
- Approved for installation in manufactured housing and mobile homes
CABINET
- Foil faced insulation for enhanced indoor air quality
- Double hemmed technology for increased structural rigidity
- Improved gasketing on doors to prevent air leaks
- Filter rack with thumb screws for easy access and removal
- Polymer plugs on drain locations for easy installation
- Baked polyester paint finished over galvanized steel for maximum durability
- High-strength, UV and heat resistant polymer drain pan designed for corrosion resistance
- Antimicrobial polymer drain pan built to resist mold and mildew growth
- 2% or less air leakage
COILS
- Omniguard™ total corrosion protection technology designed coil
- Enhanced tube-and-fin coil design featuring MHT™ Technology
- Lanced fins for maximum heat transfer
- Factory leak tested and pre-charged with nitrogen holding charge
COMPONENTS
- Variable speed blower motor (constant air flow)
- Standard transformer and blower relay
- Field-installed 5 – 20kW electric heat kits with easy plug connections
- Built-in indoor time delay for increased efficiency
- Sleeves on distributor tubing to protect tubes
WARRANTY
10 year limited warranty on all parts, extended warranty available Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions, and exclusions.
MODEL NUMBER GUIDE
PHYSICAL
Model
| ****
Volts/Hz/Phase
| ****
Max. Elec. Heat Available (kW)
| ****
Transformer Size & Type
| ****
Filter Size (in.)
| Refrigerant Connection (IDS)| ****
Installed TXV Size
| ****
Weight (lbs.)
---|---|---|---|---|---|---|---
Suction (in.)| Liquid (in.)
BCE5V18| 208-230/60/1| 7.5| 40 VA Class 2| 15 x 20 x 1| 3/4| 3/8| H4TXV01| 109
BCE5V24| 208-230/60/1| 10| 40 VA Class 2| 15 x 20 x 1| 3/4| 3/8| H4TXV01| 127
BCE5V30| 208-230/60/1| 15| 40 VA Class 2| 15 x 20 x 1| 3/4| 3/8| H4TXV01| 133
BCE5V36| 208-230/60/1| 15| 40 VA Class 2| 18 x 20 x 1| 7/8| 3/8| H4TXV02| 163
BCE5V42| 208-230/60/1| 15| 40 VA Class 2| 18 x 20 x 1| 7/8| 3/8| H4TXV02| 168
BCE5V48| 208-230/60/1| 20| 40 VA Class 2| 18 x 20 x 1| 7/8| 3/8| H4TXV02| 186
BCE5V60| 208-230/60/1| 20| 40 VA Class 2| 18 x 20 x 1| 7/8| 3/8| H4TXV03| 186
INSTALLATION CLEARANCES WITH ELECTRIC HEAT
Cabinet | 0 in. (0 mm) |
---|---|
To Plenum | 0 in. (0mm) |
To Outlet Duct within 3 ft. (914mm) | 0 in. (0 mm) |
Floor | 0 in. (0 mm) See Note #1 |
Service / Maintenance | See Note #2 |
- Units installed on combustible floors in the downflow position with electric heat do not require a downflow combustible flooring base.
- Front service access – 24 in. (610 mm) minimum.
Note – If cabinet depth is more than 24 in. (610mm), allow a minimum of the cabinet depth plus 2 in. (51 mm).
ACCESSORIES
Description | Where Used | Kit Number |
---|
Downflow Kit
| 18, 24, 30| Y9658
36, 42, 48, 60| Y9659
Horizontal Support Frame kit| All Models| 56J18
Side Return Unit Stand (upflow only)| All Models| 45K32
Single Point Power Kit| All Models| 21H39
Wall Hanging Bracket Kit (upflow only)| All Models| 45K30
High Performance Economizer (Commercial Only)| All Models| 10U53
ELECTRIC HEAT
Electric Heat Kits with Terminal Block
Size| Model| C/B Size *| Where Used| Cat #
5 kW| ECBA25-5| NA| 18, 24, 30, 36, 42, 48, 60| 16Y36
7.5 kW| ECBA25-7.5| NA| 18, 24, 30, 36, 42, 48, 60| 16Y37
10 kW| ECBA25-10| NA| 18, 24, 30, 36, 42, 48, 60| 16Y38
Electric Heat Kits with Circuit Breaker
5 kW| ECBA25-5CB| 30A| 18, 24, 30, 36, 42, 48, 60| 16Y39
7.5 kW| ECBA25-7.5CB| 45A| 18, 24, 30, 36, 42, 48, 60| 16Y41
10 kW| ECBA25-10CB| 60A| 18, 24, 30, 36, 42, 48, 60| 16Y42
12.5 kW| ECBA25-12.5CB| 50A + 25A| 30, 36, 42, 48, 60| 16Y43
15 kW| ECBA25-15CB| 60A + 25A| 30, 36, 42, 48, 60| 16Y44
20 kW| ECBA25-20CB| 60A + 50A| 48, 60| 16Y46
Replacement Circuit Breakers (2 pole)
Volts| Size| Cat #
208/240V- 1 phase
| 25A| 41K13
30A| 17K70
35A| 72K07
40A| 49K14
45A| 17K71
50A| 41K12
60A| 17K72
- Circuit breaker must match rated “Max C/B Size”; replace breaker as necessary.
ELECTRICAL
Model
| Heating Capacity (240V)| ****
Blower Amps
| Min. Circuit Ampacity| Max. Circuit Breaker Size| Single Point Power Supply
---|---|---|---|---|---
Nominal Heater SizekW| ****
kW
| ****
Btuh
| 208V| 240V| 208V| 240V| 208V| 240V
1| 2| 1| 2| 1| 2| 1| 2| Amps| Fuse| Amps| Fuse
BCE5V18
| 0| 0| 0| ****
3.9
| 4.9| | 4.9| | 15| | 15| | | | |
5| 4.8| 16400| 27| | 30| | 30| | 30| | | | |
7.5| 7.5| 25600| 39| | 44| | 40| | 45| | | | |
10| 9.6| 32700| 48| | 55| | 50| | 60| | | | |
BCE5V24
| 0| 0| 0| ****
3.9
| 4.9| | 4.9| | 15| | 15| | | | |
5| 4.8| 16400| 27| | 30| | 30| | 30| | | | |
7.5| 7.5| 25600| 39| | 44| | 40| | 45| | | | |
10| 9.6| 32700| 48| | 55| | 50| | 60| | | | |
BCE5V30
| 0| 0| 0| ****
3.9
| 4.9| | 4.9| | 15| | 15| | | | |
5| 4.8| 16400| 27| | 30| | 30| | 30| | | | |
7.5| 7.5| 25600| 39| | 44| | 40| | 45| | | | |
10| 9.6| 32700| 48| | 55| | 50| | 60| | | | |
12.5| 12.5| 42600| 42| 19| 48| 22| 45| 20| 50| 25| 61| 70| 70| 70
15| 14.4| 49100| 48| 22| 55| 25| 50| 25| 60| 25| 70| 70| 80| 80
BCE5V36
| 0| 0| 0| ****
3.9
| 6.5| | 4.9| | 15| | 15| | | | |
5| 4.8| 16400| 28| | 32| | 30| | 35| | | | |
7.5| 7.5| 25600| 40| | 46| | 40| | 50| | | | |
10| 9.6| 32700| 50| | 57| | 50| | 60| | | | |
12.5| 12.5| 42600| 44| 19| 50| 22| 45| 20| 50| 25| 63| 70| 72| 80
15| 14.4| 49100| 50| 22| 57| 25| 50| 25| 60| 25| 72| 80| 82| 90
BCE5V42
| 0| 0| 0| ****
6.9
| 8.6| | 6.5| | 15| | 15| | | | |
5| 4.8| 16400| 30| | 34| | 30| | 35| | | | |
7.5| 7.5| 25600| 42| | 48| | 45| | 50| | | | |
10| 9.6| 32700| 52| | 59| | 60| | 60| | | | |
12.5| 12.5| 42600| 46| 19| 52| 22| 50| 20| 60| 25| 65| 70| 74| 80
15| 14.4| 49100| 52| 22| 59| 25| 60| 25| 60| 25| 74| 80| 84| 90
BCE5V48
| 0| 0| 0| ****
6.9
| 8.6| | 8.6| | 15| | 15| | | | |
5| 4.8| 16400| 30| | 34| | 30| | 35| | | | |
7.5| 7.5| 25600| 42| | 48| | 45| | 50| | | | |
10| 9.6| 32700| 52| | 59| | 60| | 60| | | | |
12.5| 12.5| 42600| 46| 19| 52| 22| 50| 20| 60| 25| 65| 70| 74| 80
15| 14.4| 49100| 53| 22| 60| 25| 60| 25| 60| 25| 75| 80| 85| 90
20| 19.2| 65500| 53| 43| 60| 50| 60| 45| 60| 50| 96| 100| 110| 110
BCE5V60
| 0| 0| 0| ****
6.9
| 9.5| | 8.6| | 15| | 15| | | | |
5| 4.8| 16400| 30| | 34| | 30| | 35| | | | |
7.5| 7.5| 25600| 42| | 48| | 45| | 50| | | | |
10| 9.6| 32700| 52| | 59| | 60| | 60| | | | |
12.5| 12.5| 42600| 46| 19| 52| 22| 50| 20| 60| 25| 65| 70| 74| 80
15| 14.4| 49100| 53| 22| 60| 25| 60| 25| 60| 25| 75| 80| 85| 90
20| 19.2| 65500| 53| 43| 60| 50| 60| 45| 60| 50| 96| 100| 110| 110
- For 208 volt use .751 correction factor for kW and Btuh
- 12.5kW, 15 and 20kW (2 stage models) require 2 supply circuits
- Circuit #1 includes blower motor amps except 20kW models
BLOWER
BCE5V18 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
- Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 500| 705| 925| 1150| 365| 520| 665| 810| 500| 705| 925| 1150
NORM| 465| 650| 850| 1050| 350| 485| 610| 740| 465| 650| 850| 1050
–| 420| 600| 760| 950| 320| 425| 560| 680| 420| 600| 760| 950
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 250 cfm.
BCE5V18 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 46| 61| 74| 86| 99| 111| 124| 138
Tap 2| 97| 115| 132| 145| 162| 178| 196| 213
Tap 3| 185| 205| 229| 245| 268| 282| 300| 316
Tap 4| 340| 366| 392| 417| 439| 459| 488| 488
__
__
First Stage “COOL” Speed
| Tap 1| 30| 41| 51| 59| 69| 81| 92| 106
Tap 2| 50| 66| 80| 90| 105| 118| 126| 142
Tap 3| 87| 106| 116| 135| 148| 167| 178| 192
Tap 4| 141| 161| 181| 201| 215| 228| 247| 262
__
Second Stage “COOL” Speed
| Tap 1| 46| 61| 74| 86| 99| 111| 124| 138
Tap 2| 97| 115| 132| 145| 162| 178| 196| 213
Tap 3| 185| 205| 229| 245| 268| 282| 300| 316
Tap 4| 340| 366| 392| 417| 439| 459| 488| 488
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 40| 55| 66| 80| 93| 101| 115| 128
Tap 2| 82| 100| 113| 125| 144| 157| 176| 183
Tap 3| 146| 170| 191| 207| 224| 238| 259| 276
Tap 4| 259| 290| 314| 330| 352| 369| 391| 415
__
__
First Stage “COOL” Speed
| Tap 1| 28| 37| 46| 58| 67| 79| 89| 102
Tap 2| 45| 59| 70| 85| 96| 107| 119| 133
Tap 3| 74| 88| 102| 120| 132| 145| 161| 171
Tap 4| 115| 131| 147| 162| 185| 195| 210| 229
__
Second Stage “COOL” Speed
| Tap 1| 40| 55| 66| 80| 93| 101| 115| 128
Tap 2| 82| 100| 113| 125| 144| 157| 176| 183
Tap 3| 146| 170| 191| 207| 224| 238| 259| 276
Tap 4| 259| 290| 314| 330| 352| 369| 391| 415
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 33| 43| 56| 65| 77| 88| 96| 112
Tap 2| 65| 80| 93| 113| 126| 140| 151| 164
Tap 3| 119| 140| 153| 169| 185| 206| 220| 236
Tap 4| 195| 219| 237| 261| 281| 296| 320| 338
__
__
First Stage “COOL” Speed
| Tap 1| 23| 35| 43| 52| 63| 73| 85| 96
Tap 2| 37| 45| 54| 70| 76| 86| 99| 110
Tap 3| 59| 73| 86| 102| 113| 128| 140| 152
Tap 4| 88| 102| 119| 137| 154| 165| 185| 201
__
Second Stage “COOL” Speed
| Tap 1| 33| 43| 56| 65| 77| 88| 96| 112
Tap 2| 65| 80| 93| 113| 126| 140| 151| 164
Tap 3| 119| 140| 153| 169| 185| 206| 220| 236
Tap 4| 195| 219| 237| 261| 281| 296| 320| 338
BCE5V24 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
__
__
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
+ Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 450| 670| 900| 1120| 340| 450| 650| 770| 450| 670| 900| 1120
NORM| 420| 620| 820| 1050| 300| 400| 600| 700| 420| 620| 820| 1050
–| 390| 570| 750| 915| 280| 390| 500| 650| 390| 570| 750| 915
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 250 cfm.
BCE5V24 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 40| 50| 60| 74| 86| 95| 112| 124
Tap 2| 82| 100| 116| 136| 151| 163| 185| 197
Tap 3| 173| 190| 213| 236| 257| 283| 300| 316
Tap 4| 290| 318| 339| 363| 379| 407| 447| 463
__
__
First Stage “COOL” Speed
| Tap 1| 27| 37| 46| 57| 68| 76| 88| 104
Tap 2| 41| 54| 62| 75| 87| 97| 108| 121
Tap 3| 75| 94| 109| 127| 145| 161| 173| 191
Tap 4| 113| 133| 146| 168| 189| 205| 222| 244
__
Second Stage “COOL” Speed
| Tap 1| 40| 50| 60| 74| 86| 95| 112| 124
Tap 2| 82| 100| 116| 136| 151| 163| 185| 197
Tap 3| 173| 190| 213| 236| 257| 283| 300| 316
Tap 4| 290| 318| 339| 363| 379| 407| 447| 463
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 33| 45| 57| 68| 78| 89| 101| 115
Tap 2| 64| 81| 96| 113| 132| 145| 159| 179
Tap 3| 133| 152| 172| 190| 211| 231| 252| 270
Tap 4| 253| 278| 307| 325| 348| 374| 397| 415
__
__
First Stage “COOL” Speed
| Tap 1| 26| 36| 39| 52| 62| 73| 93| 102
Tap 2| 37| 45| 57| 66| 76| 90| 100| 113
Tap 3| 62| 80| 94| 108| 123| 135| 152| 171
Tap 4| 88| 108| 128| 145| 162| 181| 195| 214
__
Second Stage “COOL” Speed
| Tap 1| 33| 45| 57| 68| 78| 89| 101| 115
Tap 2| 64| 81| 96| 113| 132| 145| 159| 179
Tap 3| 133| 152| 172| 190| 211| 231| 252| 270
Tap 4| 253| 278| 307| 325| 348| 374| 397| 415
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 30| 43| 54| 62| 73| 84| 97| 109
Tap 2| 52| 71| 87| 99| 117| 128| 145| 157
Tap 3| 100| 118| 138| 161| 179| 193| 204| 228
Tap 4| 167| 185| 206| 230| 256| 280| 295| 316
__
__
First Stage “COOL” Speed
| Tap 1| 23| 29| 42| 48| 60| 75| 88| 93
Tap 2| 31| 39| 54| 62| 76| 86| 96| 105
Tap 3| 46| 56| 70| 84| 93| 107| 115| 133
Tap 4| 72| 87| 105| 121| 141| 158| 175| 188
__
Second Stage “COOL” Speed
| Tap 1| 30| 43| 54| 62| 73| 84| 97| 109
Tap 2| 52| 71| 87| 99| 117| 128| 145| 157
Tap 3| 100| 118| 138| 161| 179| 193| 204| 228
Tap 4| 167| 185| 206| 230| 256| 280| 295| 316
BCE5V30 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
__
__
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
+ Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 680| 885| 1115| 1340| 490| 635| 770| 930| 680| 885| 1115| 1340
NORM| 620| 810| 1020| 1220| 440| 575| 715| 845| 620| 810| 1020| 1220
–| 550| 725| 905| 1100| 411| 530| 645| 755| 550| 725| 905| 1100
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 250 cfm.
BCE5V30 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 64| 81| 108| 136| 153| 201| 210| 246
Tap 2| 120| 136| 162| 182| 198| 221| 246| 286
Tap 3| 210| 231| 259| 280| 303| 323| 348| 376
Tap 4| 367| 392| 420| 452| 486| 506| 510| 520
__
__
First Stage “COOL” Speed
| Tap 1| 32| 52| 70| 88| 96| 120| 148| 172
Tap 2| 50| 72| 91| 115| 143| 177| 200| 215
Tap 3| 87| 102| 120| 142| 170| 195| 227| 243
Tap 4| 128| 151| 176| 196| 213| 239| 259| 294
__
Second Stage “COOL” Speed
| Tap 1| 64| 81| 108| 136| 153| 201| 210| 246
Tap 2| 120| 136| 162| 182| 198| 221| 246| 286
Tap 3| 210| 231| 259| 280| 303| 323| 348| 376
Tap 4| 367| 392| 420| 452| 486| 506| 510| 520
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 55| 70| 94| 118| 148| 171| 198| 209
Tap 2| 91| 113| 132| 151| 177| 201| 222| 242
Tap 3| 167| 187| 209| 230| 252| 279| 304| 331
Tap 4| 268| 304| 329| 354| 380| 403| 431| 451
__
__
First Stage “COOL” Speed
| Tap 1| 30| 47| 64| 73| 95| 113| 121| 133
Tap 2| 46| 67| 87| 119| 140| 151| 163| 187
Tap 3| 75| 91| 113| 138| 164| 196| 228| 267
Tap 4| 104| 125| 142| 158| 187| 215| 244| 265
__
Second Stage “COOL” Speed
| Tap 1| 55| 70| 94| 118| 148| 171| 198| 209
Tap 2| 91| 113| 132| 151| 177| 201| 222| 242
Tap 3| 167| 187| 209| 230| 252| 279| 304| 331
Tap 4| 268| 304| 329| 354| 380| 403| 431| 451
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 47| 59| 78| 108| 126| 150| 158| 189
Tap 2| 72| 89| 111| 130| 157| 193| 214| 241
Tap 3| 128| 144| 162| 180| 200| 216| 254| 284
Tap 4| 194| 223| 247| 268| 292| 317| 347| 368
__
__
First Stage “COOL” Speed
| Tap 1| 30| 42| 56| 68| 86| 104| 119| 132
Tap 2| 45| 57| 84| 97| 113| 132| 157| 181
Tap 3| 67| 75| 99| 129| 161| 184| 208| 247
Tap 4| 85| 101| 120| 138| 163| 197| 234| 253
__
Second Stage “COOL” Speed
| Tap 1| 47| 59| 78| 108| 126| 150| 158| 189
Tap 2| 72| 89| 111| 130| 157| 193| 214| 241
Tap 3| 128| 144| 162| 180| 200| 216| 254| 284
Tap 4| 194| 223| 247| 268| 292| 317| 347| 368
BCE5V36 PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
__
__
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
+ Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 930| 1155| 1390| 1530| 640| 815| 970| 1150| 930| 1155| 1390| 1530
NORM| 830| 1050| 1260| 1450| 590| 725| 875| 1025| 830| 1050| 1260| 1450
–| 740| 940| 1135| 1330| 545| 650| 780| 910| 740| 940| 1135| 1330
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 250 cfm.
BCE5V36 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 111| 132| 152| 193| 226| 246| 271| 282
Tap 2| 188| 215| 242| 271| 295| 327| 391| 412
Tap 3| 298| 325| 361| 395| 433| 474| 491| 515
Tap 4| 464| 503| 516| 537| 526| 527| 529| 522
__
__
First Stage “COOL” Speed
| Tap 1| 53| 78| 98| 112| 135| 151| 173| 192
Tap 2| 78| 101| 118| 149| 173| 191| 217| 237
Tap 3| 115| 136| 162| 185| 237| 265| 284| 308
Tap 4| 166| 196| 228| 252| 284| 303| 364| 399
__
Second Stage “COOL” Speed
| Tap 1| 111| 132| 152| 193| 226| 246| 271| 282
Tap 2| 188| 215| 242| 271| 295| 327| 391| 412
Tap 3| 298| 325| 361| 395| 433| 474| 491| 515
Tap 4| 464| 503| 516| 537| 526| 527| 529| 522
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 79| 102| 128| 170| 189| 210| 225| 254
Tap 2| 138| 165| 191| 219| 243| 300| 328| 347
Tap 3| 225| 249| 287| 315| 351| 377| 407| 429
Tap 4| 342| 384| 425| 456| 510| 531| 533| 525
__
__
First Stage “COOL” Speed
| Tap 1| 41| 69| 80| 100| 115| 141| 159| 176
Tap 2| 64| 80| 114| 136| 155| 169| 197| 214
Tap 3| 241| 219| 202| 155| 145| 116| 94| 85
Tap 4| 319| 296| 258| 211| 189| 163| 138| 123
__
Second Stage “COOL” Speed
| Tap 1| 79| 102| 128| 170| 189| 210| 225| 254
Tap 2| 138| 165| 191| 219| 243| 300| 328| 347
Tap 3| 225| 249| 287| 315| 351| 377| 407| 429
Tap 4| 342| 384| 425| 456| 510| 531| 533| 525
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 64| 81| 119| 142| 161| 184| 194| 219
Tap 2| 111| 131| 151| 174| 221| 255| 268| 293
Tap 3| 168| 199| 222| 248| 287| 304| 359| 396
Tap 4| 249| 293| 331| 340| 386| 410| 443| 475
__
__
First Stage “COOL” Speed
| Tap 1| 38| 59| 79| 90| 107| 121| 139| 170
Tap 2| 49| 73| 105| 112| 131| 151| 162| 184
Tap 3| 69| 90| 122| 149| 170| 197| 207| 229
Tap 4| 105| 130| 147| 172| 219| 242| 262| 278
__
Second Stage “COOL” Speed
| Tap 1| 64| 81| 119| 142| 161| 184| 194| 219
Tap 2| 111| 131| 151| 174| 221| 255| 268| 293
Tap 3| 168| 199| 222| 248| 287| 304| 359| 396
Tap 4| 249| 293| 331| 340| 386| 410| 443| 475
BCE5V42 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
__
__
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
+ Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 1130| 945| 1575| 1810| 780| 945| 1110| 1275| 1130| 1370| 1575| 1810
NORM| 1020| 1255| 1440| 1650| 710| 860| 1000| 1160| 1020| 1255| 1440| 1650
–| 920| 1135| 1300| 1490| 670| 780| 910| 1040| 920| 1135| 1300| 1490
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 450 cfm.
BCE5V42 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 148| 175| 198| 227| 258| 275| 312| 364
Tap 2| 239| 268| 295| 323| 351| 375| 409| 437
Tap 3| 338| 375| 411| 437| 470| 507| 537| 563
Tap 4| 504| 531| 578| 614| 657| 687| 716| 763
__
__
First Stage “COOL” Speed
| Tap 1| 67| 91| 115| 143| 165| 185| 202| 223
Tap 2| 101| 127| 145| 175| 213| 241| 251| 277
Tap 3| 140| 164| 196| 215| 250| 265| 299| 345
Tap 4| 190| 229| 245| 285| 303| 324| 363| 398
__
Second Stage “COOL” Speed
| Tap 1| 148| 175| 198| 227| 258| 275| 312| 364
Tap 2| 239| 268| 295| 323| 351| 375| 409| 437
Tap 3| 338| 375| 411| 437| 470| 507| 537| 563
Tap 4| 504| 531| 578| 614| 657| 687| 716| 763
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 116| 146| 168| 196| 221| 250| 286| 305
Tap 2| 188| 215| 243| 266| 295| 319| 348| 383
Tap 3| 270| 300| 327| 353| 384| 417| 450| 474
Tap 4| 375| 416| 459| 500| 517| 556| 588| 618
__
__
First Stage “COOL” Speed
| Tap 1| 57| 78| 107| 134| 151| 171| 192| 225
Tap 2| 85| 111| 135| 158| 197| 213| 226| 246
Tap 3| 118| 138| 163| 186| 219| 254| 291| 305
Tap 4| 170| 198| 217| 247| 267| 295| 328| 380
__
Second Stage “COOL” Speed
| Tap 1| 116| 146| 168| 196| 221| 250| 286| 305
Tap 2| 188| 215| 243| 266| 295| 319| 348| 383
Tap 3| 270| 300| 327| 353| 384| 417| 450| 474
Tap 4| 375| 416| 459| 500| 517| 556| 588| 618
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 96| 119| 138| 162| 191| 227| 247| 266
Tap 2| 153| 171| 200| 226| 249| 286| 303| 348
Tap 3| 204| 237| 259| 286| 319| 336| 371| 401
Tap 4| 282| 312| 353| 384| 417| 441| 468| 503
__
__
First Stage “COOL” Speed
| Tap 1| 56| 74| 98| 121| 131| 169| 178| 200
Tap 2| 79| 93| 115| 140| 165| 188| 199| 218
Tap 3| 98| 117| 138| 170| 196| 228| 250| 260
Tap 4| 126| 148| 175| 194| 222| 254| 300| 322
__
Second Stage “COOL” Speed
| Tap 1| 96| 119| 138| 162| 191| 227| 247| 266
Tap 2| 153| 171| 200| 226| 249| 286| 303| 348
Tap 3| 204| 237| 259| 286| 319| 336| 371| 401
Tap 4| 282| 312| 353| 384| 417| 441| 468| 503
BCE5V48 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
__
__
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
+ Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 1375| 1600| 1820| 2185| 960| 1125| 1285| 1620| 1375| 1600| 1820| 2185
NORM| 1260| 1455| 1655| 2085| 885| 1035| 1185| 1475| 1260| 1455| 1655| 2085
–| 1125| 1310| 1490| 1885| 790| 925| 1060| 1330| 1125| 1310| 1490| 1885
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 450 cfm.
BCE5V48 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 221| 244| 277| 308| 345| 372| 406| 449
Tap 2| 325| 363| 403| 448| 478| 517| 549| 578
Tap 3| 465| 502| 550| 592| 637| 671| 711| 755
Tap 4| 922| 985| 1000| 1006| 996| 991| 996| 989
__
__
First Stage “COOL” Speed
| Tap 1| 94| 129| 152| 179| 206| 247| 265| 288
Tap 2| 135| 168| 190| 220| 247| 275| 313| 367
Tap 3| 176| 213| 241| 270| 292| 344| 366| 405
Tap 4| 330| 368| 405| 439| 478| 515| 542| 576
__
Second Stage “COOL” Speed
| Tap 1| 221| 244| 277| 308| 345| 372| 406| 449
Tap 2| 325| 363| 403| 448| 478| 517| 549| 578
Tap 3| 465| 502| 550| 592| 637| 671| 711| 755
Tap 4| 922| 985| 1000| 1006| 996| 991| 996| 989
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 180| 208| 240| 275| 296| 333| 362| 410
Tap 2| 252| 287| 311| 346| 380| 407| 456| 484
Tap 3| 347| 392| 434| 457| 507| 534| 579| 615
Tap 4| 696| 749| 797| 841| 881| 927| 972| 999
__
__
First Stage “COOL” Speed
| Tap 1| 77| 102| 128| 153| 185| 210| 231| 247
Tap 2| 111| 133| 164| 188| 219| 251| 279| 304
Tap 3| 144| 175| 206| 233| 262| 285| 325| 352
Tap 4| 251| 283| 317| 364| 382| 419| 447| 482
__
Second Stage “COOL” Speed
| Tap 1| 180| 208| 240| 275| 296| 333| 362| 410
Tap 2| 252| 287| 311| 346| 380| 407| 456| 484
Tap 3| 347| 392| 434| 457| 507| 534| 579| 615
Tap 4| 696| 749| 797| 841| 881| 927| 972| 999
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 133| 164| 192| 221| 253| 280| 318| 352
Tap 2| 203| 224| 270| 291| 317| 371| 403| 430
Tap 3| 273| 309| 343| 376| 413| 441| 471| 522
Tap 4| 518| 573| 610| 667| 694| 732| 776| 821
__
__
First Stage “COOL” Speed
| Tap 1| 61| 87| 116| 141| 168| 186| 204| 222
Tap 2| 85| 109| 135| 166| 197| 222| 249| 270
Tap 3| 115| 142| 168| 199| 220| 253| 287| 330
Tap 4| 194| 227| 253| 288| 320| 359| 388| 415
__
Second Stage “COOL” Speed
| Tap 1| 133| 164| 192| 221| 253| 280| 318| 352
Tap 2| 203| 224| 270| 291| 317| 371| 403| 430
Tap 3| 273| 309| 343| 376| 413| 441| 471| 522
Tap 4| 518| 573| 610| 667| 694| 732| 776| 821
BCE5V60 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
__
__
“ADJUST”
Jumper Setting
| Jumper Speed Positions
“HEAT” Speed (W)| First Stage “COOL” Speed (Y1)| Second Stage “COOL” Speed (Y1
+ Y2)
1| 2| 3| 4| 1| 2| 3| 4| 1| 2| 3| 4
cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm| cfm
+| 1600| 1835| 2030| 2190| 1110| 1285| 1380| 1615| 1600| 1835| 2030| 2190
NORM| 1465| 1675| 1855| 2085| 1000| 1160| 1250| 1470| 1465| 1675| 1855| 2085
–| 1320| 1500| 1675| 1890| 895| 1035| 1115| 1320| 1320| 1500| 1675| 1890
NOTES – The effect of static pressure, filter and electric heater resistance is included in the air volumes listed. First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applications – minimum blower speed is 450 cfm.
BCE5V60 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
__
Jumper Speed Positions
| Motor Watts @ Various External Static Pressures – in. wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
__
__
“HEAT” Speed
| Tap 1| 330| 360| 403| 444| 488| 521| 563| 600
Tap 2| 469| 505| 564| 616| 649| 685| 735| 776
Tap 3| 631| 671| 734| 782| 832| 894| 931| 974
Tap 4| 903| 957| 1016| 1015| 1013| 1002| 1002| 998
__
__
First Stage “COOL” Speed
| Tap 1| 146| 166| 194| 223| 267| 300| 340| 379
Tap 2| 195| 221| 252| 278| 319| 358| 383| 427
Tap 3| 225| 260| 286| 319| 357| 399| 427| 466
Tap 4| 339| 382| 417| 447| 494| 532| 567| 611
__
Second Stage “COOL” Speed
| Tap 1| 330| 360| 403| 444| 488| 521| 563| 600
Tap 2| 469| 505| 564| 616| 649| 685| 735| 776
Tap 3| 631| 671| 734| 782| 832| 894| 931| 974
Tap 4| 903| 957| 1016| 1015| 1013| 1002| 1002| 998
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
Jumper Speed Positions| Motor Watts @ Various External Static Pressures – in.
wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
“HEAT” Speed| Tap 1| 251| 288| 320| 355| 391| 440| 463| 514
Tap 2| 348| 397| 433| 482| 515| 565| 607| 650
Tap 3| 472| 524| 578| 614| 664| 704| 749| 810
Tap 4| 696| 740| 792| 856| 886| 939| 984| 983
First Stage “COOL” Speed| Tap 1| 110| 105| 164| 196| 233| 263| 297| 320
Tap 2| 152| 182| 205| 244| 271| 300| 347| 387
Tap 3| 177| 205| 238| 271| 311| 341| 375| 424
Tap 4| 254| 298| 331| 367| 408| 444| 473| 527
Second Stage “COOL” Speed| Tap 1| 251| 288| 320| 355| 391| 440| 463| 514
Tap 2| 348| 397| 433| 482| 515| 565| 607| 650
Tap 3| 472| 524| 578| 614| 664| 704| 749| 810
Tap 4| 696| 740| 792| 856| 886| 939| 984| 983
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
Jumper Speed Positions| Motor Watts @ Various External Static Pressures – in.
wg.
| 0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
“HEAT” Speed| Tap 1| 189| 228| 263| 294| 328| 358| 403| 430
Tap 2| 268| 304| 343| 380| 427| 461| 483| 549
Tap 3| 355| 401| 431| 487| 523| 569| 611| 642
Tap 4| 506| 549| 607| 646| 689| 720| 775| 834
First Stage “COOL” Speed| Tap 1| 88| 119| 139| 173| 198| 244| 260| 275
Tap 2| 117| 145| 169| 200| 225| 272| 309| 338
Tap 3| 130| 161| 187| 217| 253| 286| 325| 368
Tap 4| 192| 237| 265| 295| 324| 364| 405| 440
Second Stage “COOL” Speed| Tap 1| 189| 228| 263| 294| 328| 358| 403| 430
Tap 2| 268| 304| 343| 380| 427| 461| 483| 549
Tap 3| 355| 401| 431| 487| 523| 569| 611| 642
Tap 4| 506| 549| 607| 646| 689| 720| 775| 834
UNIT DIMENSIONS – IN. (MM)
Dimension | 18 | 24 | 30 | 36-42 | 48 | 60 |
---|---|---|---|---|---|---|
in. | mm | in. | mm | in. | mm | in. |
A | 43.5 | 1105 | 45.5 | 1156 | 47 | 1194 |
B | 18.5 | 470 | 18.5 | 470 | 18.5 | 470 |
C | 16.5 | 419 | 16.5 | 419 | 16.5 | 419 |
D | 16.25 | 413 | 16.25 | 413 | 16.25 | 413 |
All specifications and illustrations subject to change without notice and without incurring obligations.
1-800-448-5872
© 2023 Allied Air Enterprises LLC, a Lennox International Inc. Company.
NOTE: For the latest AHRI system matches, please visit
www.alliedratings.com or
www.AHRIdirectory.org
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>