Product Information

The product is a Wi-Fi enabled thermostat. It comes with a Daisy Wi-Fi Thermostat, Thermostat Base, Mounting Hardware, Quick Guide, and Wiring Labels.  The thermostat works with common 24 volt systems and is not compatible with millivolt systems or 120/240 volt systems such as baseboard electric heat.

Product Usage Instructions

  1. Before starting the installation, check the wire terminal compatibility with the User Guide.
  2. Switch off the power to your HVAC system at the breaker box or the system switch.
    • WARNING: This step is important to protect your system.
  3. If your old thermostat contains mercury, do not place it in the trash. Contact the Thermostat Recycling Corporation for proper disposal information
  4. Leave the wires connected and remove the old thermostat from the wall. Take photos of the wire connections for reference.
  5. Label the wires using the included tags. The labels should match your existing thermostat terminal assignments.
    • Note: Use the provided blank tags if no matching tags exist.
  6. After labeling the wires, remove the existing wallplate from the wall.
  7. Separate the new Wi-Fi thermostat from its wall plate by grabbing hold of the back corners while holding the front of the thermostat. Hold the wallplate tightly to pull the thermostat apart.
  8. Mount the new Wi-Fi thermostat wallplate using the provided screws and anchors. Check if existing wall anchors can be used by aligning the new wallplate with them.
  9. Wiring for a conventional system:
    • Start with the C wire and match the tag on the wire to the terminal label.
    • Loosen the screw and insert the wire on the inside edge of the terminal, then tighten the screw.
    • Give the wire a gentle tug to confirm it is secure.
    • Repeat the above steps for the remaining wires.
    • Push excess wire back into the wall opening.
  10. Wiring cross-reference for conventional heat pump systems:
    • Remove the metal jumper only if you have both R and RC wires.
  11. Wiring for heat pump systems:
    • Start with the C wire and match the rest of the tags on the wires to the terminal labels.
    • Loosen the screw and insert the wire on the inside edge of the terminal, then tighten the screw.

Please refer to the provided user manual at https://manual-hub.com/ for more detailed instructions and information.

INSTALLING THERMOSTAT

Important! Check wire terminal compatibility with User Guide before starting installation.

Inside your Daisy thermostat box.

  1. Daisy Wi-Fi Thermostat
  2. Thermostat Base
  3. Mounting Hardware
  4. Quick Guide
  5. Wiring Labels
  • Switch power OFF to your HVAC system.
    • Important! Switch the power OFF to your HVAC systems at the breaker box or the system switch to protect your system.
    • WARNING: This thermostat works with common 24 volt system. It will not work with millivolt systems or with 120/240 volt systems such as baseboard electric heat.
    • NOTICE: To avoid possible compressor damage, do not run air conditioner if the outside temperature drops below 50˚F (10˚C)
  • Leave wires connected and remove old thermostat from wall. Take photos of wire connections to reference later on.
    • MERCURY NOTICE: Do not place your old thermostat in the trash if it contains mercury. Contact the Thermostat Recycling Corporation at www.thermostat-recycle.org or
      1-800-238-8192 for information on how and where to properly and safely dispose of your old thermostat.

Label the wires.
Do not label wires by color. Use the tags included to label as you disconnect each wire. Wires should be labeled according to your existing thermostat terminal assignments, not by color.

Note: Blank tags are provided to write the terminal label if you find no matching tags exist.

Remove the wallplate.
After all wires have been labeled and disconnected, remove the existing wallplate from the wall.CYDATA-DAISY-Wi-Fi-Enabled-
Thermostat-06

Separate the new Wi-Fi thermostat from its wall plate
Grab hold of the back corners while holding the front of the new thermostat. Hold the wallplate tightly to pull the thermostat apart.

Mount new Wi-Fi thermostat wallplate
Screws and anchors are provided to mount the new wallplate. Existing wall anchors may be usable and can be checked by holding the new wallplate up to the anchors to check that they are in alignment.

Wiring for conventional system.

  • Note: You must have a C Wire or equivalent.
  • Note: Wiring will be specific to each application and may be different than wiring shown above.
  1. Start with the C wire to match the tag on the wire to the terminal label.
  2. Loosen the screw. Insert wire on inside edge of terminal, then tighten screw.
  3. Give wire a gentle tug to confirm wire is secure.
  4. Repeat steps a-c for remaining wires.
  5. Excess wire should be pushed back into opening of wall.
  6. Continue to step 8 on page 5.
    CYDATA-DAISY-Wi-Fi-Enabled-Thermostat-09

Note: Remove metal jumper only if you have both R and RC wires.

Wiring for heat pump system only.
Note: You must have a C Wire or equivalent.

  1. Start with the C wire and continue to match the rest of the tags on the wires to the terminal labels.
  2. Loosen the screw. Insert wire on inside edge of terminal, then tighten screw.
  3. Give wire a gentle tug to confirm wire is secured.
  4. Repeat steps a-c for remaining wires.
  5.  Excess wire should be pushed back into opening of wall.
  6. Continue to step 8

Note: Wiring will be specific to each application and may be different than wiring shown below. Note: If the old thermostat has separate wires on AUX and E, place both wires into the AUX/E terminal. No jumper is required.

  1. Alternate Wiring for conventional system.
    Note: You must have a C Wire or equivalent.

  2. Remove metal jumper if the old thermostat had both R and RH wires.

  3. Only remove metal jumper connecting R

  4. Alternate Wiring for heat pump system only. Note: You must have a C Wire or equivalent to install.

  5. If the old thermostat had separate wires on AUX and E, insert both wires into the AUX/E terminal. No jumper is required.

  6. If the old thermostat had an O wire and not a B wire, insert the O wire to the O/B terminal.

Step 8: Attach the new Wi-Fi thermostat to wallplate.
Important!

  • Verify the C Wire is connected at the thermostat and at the HVAC system.
  • Check that thermostat and the wallplate are aligned, then snap securely into place. 

Switch HVAC system ON.
Important!

  • Secure the HVAC system door firmly.
  • Switch ON power for the HVAC system at the breaker box or power switch.

Set-up thermostat (see User Guide).

DAISY Wi-Fi Programmable Thermostat / INSTALL GUIDE

Documents / Resources

| CYDATA DAISY Wi-Fi Enabled Thermostat [pdf] Installation Guide
DAISY Wi-Fi Enabled Thermostat, DAISY, Wi-Fi Enabled Thermostat, Enabled Thermostat, Thermostat
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals