CHAMPION POWER EQUIPMENT 42436 Portable Generator Owner’s Manual
- June 13, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
CHAMPION POWER EQUIPMENT 42436 Portable Generator
Product Information
- Model Number: 42436
- Manufacturer: Champion Power Equipment
- Country of Origin: China
- Starting Watts: 1500 Watts
- Running Watts: 1200 Watts
- Type: Portable Generator
Introduction
Congratulations on your purchase of a Champion Power Equipment generator.
CPE designs and builds generators to strict specifications. With proper use
and maintenance, this generator will bring years of satisfying service.
Accessories
Champion Power Equipment manufactures and sells accessories designed to help
you get the most from your purchase. To find out more about our covers and
power cables, please visit our website at:
www.championpowerequipment.com
Portable Power Generator
This unit is a gasoline engine driven, alternating current (AC) generator. It
is designed to supply electrical power for lighting, appliances, tools, and
similar equipment.
This Booklet
Every effort has been made to ensure the accuracy and completeness of the
information in this manual. We reserve the right to change, alter, and/or
improve the product and this document at any time without prior notice.
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your Champion Power Equipment product is designed and rated for continuous
operation at ambient temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures ranging from -15°C (5°F)
to 50°C (122°F) for short periods. If the product is exposed to temperatures
outside this range during storage, it should be brought back within this range
before operation. In any event, the product must always be operated outdoors,
in a well-ventilated area and away from doors, windows and other vents.
Have questions or need assistance?
Do not return this product to the store!
WE ARE HERE TO HELP!
Visit our website:
www.championpowerequipment.com for
more info:
- Product Info & Updates
- Frequently Asked Questions
- Tech Bulletins
- Product Registration
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
For residents of California:
WARNING: This product contains chemicals known to the State of California
to cause cancer or birth defects and other reproductive harm.
WARNING: The engine exhaust from this product contains chemicals known to
the State of California to cause cancer and birth defects and other
reproductive harm.
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
INTRODUCTION
Introduction
Congratulations on your purchase of a Champion Power Equipment generator. CPE
designs and builds generators to strict specifications. With proper use and
maintenance, this generator will bring years of satisfying service.
Portable Power Generator
This unit is a gasoline engine driven, alternating current (AC) generator. It
is designed to supply electrical power for lighting, appliances, tools and
similar equipment.
Accessories
Champion Power Equipment manufactures and sells accessories designed to help
you get the most from your purchase. To find out more about our covers and
power cables, please visit our web site at:
www.championpowerequipment.com
This Booklet
Every effort has been made to ensure the accuracy and completeness of the
information in this manual. We reserve the right to change, alter and/or
improve the product and this document at any time without prior notice.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this information available when ordering parts and when making technical or warranty inquiries.
Champion Power Equipment Support
1-877-338-0999
Model Number
42436
Serial Number
Date of Purchase
Purchase Location
For Oil Type see ‘Add Engine Oil‘ section. For Fuel Type see ‘Add Fuel‘
section.
This manual uses the following symbols to help differentiate between different
kinds of information. The safety symbol is used with a key word to alert you
to potential hazards in operating and owning power equipment.
Follow all safety messages to avoid or reduce the risk of serious injury or
death.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, may result in property damage.
NOTE
If you have questions regarding your generator, we can help. Please call our
help line at 1-877-338-0999.
SAFETY RULES
WARNING
Read this manual thoroughly before operating your generator. Failure to follow
instructions could result in serious injury or death.
WARNING
The engine exhaust from this product contains chemicals known to the state of
California to cause cancer, birth defects, or other reproductive harm.
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas.
Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If
you start to feel dizzy or weak, get to fresh air immediately.
Operate generator outdoors only in a well ventilated area.
DO NOT operate the generator inside any building, including garages,
basements, crawlspaces and sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle. DO NOT allow exhaust fumes to
enter a confined area through windows, doors, vents or other openings.
DANGER CARBON MONOXIDE: using a generator indoors CAN KILL YOU IN MINUTES.
DANGER
Rotating parts can entangle hands, feet, hair, clothing and/or accessories.
Traumatic amputation or severe laceration can result.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to operate or service the
generator
Use a ground fault circuit interrupter (GFCI) in damp areas and areas
containing conductive material such as metal decking.
Use approved transfer equipment to isolate generator from your electric
utility and Notify your utility company before connecting your generator to
your power system.
WARNING
Sparks can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot contact the plug.
DO NOT check for spark with the plug removed. Use only approved spark plug
testers.
WARNING
Running engines produce heat. Severe burns can occur on contact.
Combustible material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching. Maintain at least 3 ft. (91.4 cm) of
clearance on all sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
WARNING
Medical and Life Support Uses.
In case of emergency, call 911 immediately. NEVER use this product to power
life support devices or life support appliances.
NEVER use this product to power medical devices or medical appliances.
Inform your electricity provider immediately if you or anyone in your
household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power would cause you
or anyone in your household to experience a medical emergency.
DANGER
Fuel and fuel vapors are highly flammable and extremely explosive.
Fire or explosion can cause severe burns or death. Unintentional startup can
result in entanglement, traumatic amputation or laceration.
When adding or removing fuel:
Turn the generator off and let it cool for at least two minutes before
removing the fuel cap. Loosen the cap slowly to relieve pressure in the tank.
Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump gas
directly into the generator at the gas station. Use an approved container to
transfer the fuel to the generator.
DO NOT overfill the fuel tank.
Always keep fuel away from sparks, open flames, pilot lights, heat and other
sources of ignition.
DO NOT light or smoke cigarettes.
When starting the generator:
DO NOT attempt to start a damaged generator. Make certain that the gas cap,
air filter, spark plug, fuel lines and exhaust system are properly in place.
Allow spilled fuel to evaporate fully before attempting to start the engine.
Make certain that the generator is resting firmly on level ground.
When operating the generator:
DO NOT move or tip the generator during operation. DO NOT tip the generator or
allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off position and the fuel
tank is empty.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other sources of
ignition.
WARNING
Operation of this equipment may create sparks that can start fires around dry
vegetation.
A spark arrestor may be required. The operator should contact local fire
agencies for laws or regulations relating to fire prevention requirements.
WARNING
Rapid retraction of the starter cord will pull hand and arm towards the engine
faster than you can let go. Unintentional startup can result in entanglement,
traumatic amputation or laceration.
Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the starter cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices plugged in.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or
electrical devices connected to it.
DO NOT overload the generator.
Start the generator and allow the engine to stabilize before connecting
electrical loads.
Connect electrical equipment in the off position, and then turn them on for
operation.
Turn electrical equipment off before stopping the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life and
void your warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust, or dirt.
DO NOT allow any material to block the cooling slots. If connected devices
overheat, turn them off and disconnect them from the generator.
DO NOT use the generator if:-
- Electrical output is lost
- Equipment sparks, smokes or emits flames
- Equipment vibrates excessively
CONTROLS AND FEATURES
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
- Fuel Tank – 1.5 gal. (5.5 L) capacity fuel tank.
- Choke – Used to start the engine.
- Fuel Valve – Turn this valve to the “ON” position to supply fuel to the engine.
- Air Cleaner – Protects the engine by filtering dust and debris from the intake air.
- Recoil Starter – Used to manually start the engine.
- Oil Filler Cap – Check and fill engine oil level.
- Power Panel – See “Power Panel” section.
Power Panel
- Engine Switch – Used to turn the generator on and off.
- Voltmeter – Used to display alternator output voltage.
- Circuit Breaker – Protects the generator against electrical overloads. Push to reset breaker.
- 120 Volt AC, 20 Amp Receptacle (NEMA 5-20R)
- May be used to supply electrical power for the operation of 120 Volt AC, 10 Amp, single phase 60 Hz electrical loads.
- Ground Terminal – Consult an electrician for local grounding regulations.
Parts Included
Your 42436 Gasoline Powered Generator ships with the following parts:
Other
- Vibration Mount (Engine Side) . . . . . . . . . . . . . . . 2
- Vibration Mount (Alternator Side) . . . . . . . . . . . . . 2
- Nut (M8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
- Flange Bolt M8x20 . . . . . . . . . . . . . . . . . . . . . . 2
- Oil Funnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
- Spark Plug Socket . . . . . . . . . . . . . . . . . . . . . . . 1
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory
without oil. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our
help line at 1-877-338-0999. Please
have your serial number and model number available.
Remove the Generator from the Shipping Carton
- Set the shipping carton on a solid, flat surface.
- Remove everything from the carton except the generator.
- Carefully cut each corner of the box from top to bottom. Fold each side flat on the ground to provide a surface area to install the wheel kit and support leg.
Attaching the Engine Vibration Mounts
- Thread the vibration mount bolt through the frame (engine side).
- Firmly secure the bolt to the frame with the M8 nut. Tighten. DO NOT over tighten.
- Repeat steps 1-2 for the remaining mount (2 total).
Attaching the Alternator Vibration Mounts
- Thread the flange bolt (M8x20) through the vibration mount and then through the frame (alternator side).
- Firmly secure the bolt to the frame with the M8 nut. Tighten. DO NOT over tighten.
- Repeat steps 1-2 for the remaining mount (2 total).
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine before it has been properly filled
with the recommended type and amount of oil. Damage to the generator as a
result of failure to follow these instructions will void your warranty.
NOTE
The recommended oil type is 10W-30 automotive oil.
-
Place the generator on a flat, level surface.
-
Remove oil fill cap/dipstick to add oil.
-
Add 0.4 qt. (0.4 L) of oil (not included) and replace oil fill cap/dipstick. DO NOT OVERFILL.
-
Check engine oil level daily and add as needed.
CAUTION
The engine is equipped with a low-oil-shutoff and will stop when the oil level
in the crankcase falls below the threshold level.
NOTE
Check oil often during the break-in period. Refer to the Maintenance section
for recommended service intervals.
NOTE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no
additional lubrication for the life of the bearing.
Add Fuel
-
Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85 and an ethanol content of less than 10% by volume.
-
DO NOT mix oil with fuel.
-
Clean the area around the fuel cap.
-
Remove the fuel cap.
-
Slowly add fuel to the tank. DO NOT OVERFILL. Fuel can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for fuel expansion, more than ¼ in. (6.4 mm) is recommended. Fuel can be forced out of the tank as a result of expansion if it is overfilled, and can affect the stable running condition of the product. When filling the tank, it is recommended to leave enough space for the fuel to expand.
-
Screw on the fuel cap and wipe away any spilled fuel.
CAUTION
Use regular unleaded gasoline with a minimum octane rating of 85.-
- Do not mix oil and gasoline.
- Fill tank to approximately ¼ in. (6.4 mm) below the top of the tank to allow for fuel expansion.
- DO NOT pump gas directly into the generator at the gas station. Use an approved container to transfer the fuel to the generator.
- DO NOT fill fuel tank indoors.
- DO NOT fill fuel tank when the engine is running or hot. DO NOT overfill the fuel tank.
- DO NOT light cigarettes or smoke when filling the fuel tank.
WARNING
Pouring fuel too fast through the fuel screen may result in blow back of fuel
at the operator while filling.
NOTE
Our engines work well with 10% or less ethanol blend fuels. When using
blended fuels there are some issues worth noting:
- Ethanol-gasoline blends can absorb more water than gasoline alone.
- These blends can eventually separate, leaving water or a watery goo in the tank, fuel valve and carburetor.
- With gravity-fed fuel supplies, this compromised fuel can be drawn into the carburetor and cause damage to the engine and/or potential hazards.
- There are only a few suppliers of fuel stabilizer that are formulated to work with ethanol blend fuels.
- Any damages or hazards caused by using improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not covered by manufacture’s warranty.
It is advisable to always shut off the fuel supply, run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days.
Grounding
Your generator must be properly connected to an appropriate ground to help
prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the frame of the generator has been provided on
the power panel. For remote grounding, connect of a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground terminal and a
copper rod driven into the ground. We strongly recommend that you consult with
a qualified electrician to ensure compliance with local electrical codes.
Generator Location
NEVER operate the generator inside any building, including garages, basements,
crawlspaces and sheds, enclosure or compartment, including the generator
compartment of a recreational vehicle. Please consult your local authority. In
some areas, generators must be registered with the local utility. Generators
used at construction sites may be subject to additional rules and regulations.
Generators should be on a flat, level surface at all times. (Even while not in
operation) Generators must have at least 5 ft. (1.5 m) of clearance from all
combustible material. In addition to clearance from
all combustible material, generators must also have
at least 3 ft. (91.4 cm) of clearance on all sides to allow for adequate
cooling, maintenance and servicing. Generators should never be started or
operated in the back of a SUV, camper, trailer, in the bed of a truck
(regular, flat or otherwise), under staircases/stairwells, next to walls or
buildings, or in any other location that will not allow for adequate cooling
of the generator and/or the muffler. DO NOT contain generators during
operation. Allow generators to properly cool before transport or storage.
Place the generator in a well-ventilated area. DO NOT place the generator near
vents or intakes where exhaust fumes could be drawn into occupied or confined
spaces. Carefully consider wind and air currents when positioning generator.
Failure to follow proper safety precautions may void manufacturer’s warranty.
WARNING
Do not operate or store the generator in rain, snow, or wet weather.
Using a generator or electrical appliance in wet conditions, such as rain or
snow, or near a pool or sprinkler system, or when your hands are wet, could
result in electrocution.
WARNING
During operation the muffler and exhaust fumes produced will become hot. If
adequate cooling and breathing space are not supplied, or if the generator is
blocked or contained, temperatures can become extremely heated and may lead to
fire.
Grounding
The generator system ground connects the frame to the ground terminals on the
power panel.
- The generator (stator winding) is isolated from the frame and from the AC receptacle ground pin.
- Electrical devices that require a grounded receptacle pin connection may not function properly.
Surge Protection
CAUTION
Voltage fluctuation may impair the proper functioning of sensitive electronic
equipment.
Electronic devices, including computers and many programmable appliances use
components that are designed to operate within a narrow voltage range and may
be affected by momentary voltage fluctuations. While there is no way to prevent
voltage fluctuations, you can take steps to protect sensitive electronic
equipment.
- Install UL1449, CSA-listed, plug-in surge suppressors on the outlets feeding your sensitive equipment. Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short-duration voltage fluctuations.
Starting the Engine
- Make certain the generator is on a flat, level surface.
- Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
- Turn the Fuel Valve to the “ON” position.
- Flip the engine switch to the “ON” position.
- Move the choke lever to the “CHOKE” position.
- Pull the starter cord slowly until resistance is felt and then pull rapidly
- Do not over-choke. As soon as engine starts, move the choke lever to the “RUN” position.
NOTE
Keep choke lever in “Choke” position for only 1 pull of the recoil starter.
After first pull, move choke lever to the “Run” position for up to the next 3
pulls of the recoil starter. Too much choke leads to sparkplug fouling/engine
flooding due to the lack of incoming air. This will cause the engine not to
start.
NOTE
If the engine starts but does not run make certain that the generator is on a
flat, level surface. The engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level falls below a critical
threshold.
OPERATION
Connecting Electrical Loads
- Let the engine stabilize and warm up for a few minutes after starting
- Plug in and turn on the desired 120 Volt AC single phase, 60 Hz electrical loads.
- DO NOT connect 3-phase loads to the generator.
- DO NOT connect 50 Hz loads to the generator.
- DO NOT overload the generator.
NOTE
Connecting a generator to your electric utility company’s power lines or to
another power source may be against the law. In addition this action, if done
incorrectly, could damage your generator and appliances and could cause
serious injury or even death to you or a utility worker who may be working on
nearby power lines. If you plan to run a portable electric generator during an
outage, please notify your electric utility company immediately and remember
to plug your appliances directly into the generator. Do not plug the generator
into any electric outlet in your home. Doing so could create a connection to
the utility company power lines. You are responsible for ensuring that your
generator’s electricity does not feed back into the electric utility power
lines.
If the generator will be connected to a building electrical system, consult
your local utility company or a qualified electrician. Connections must isolate
generator power from utility power and must comply with all applicable laws
and codes.
Stopping the Engine
- Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or turned on.
- Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.
- Turn the Fuel Valve to the “OFF” position.
- Let the engine run until fuel starvation has stopped the engine. This usually takes a few minutes.
- Press the ignition switch to the “OFF” position. Important: Always ensure that the Fuel Valve and the Engine Switch are in the “OFF” position when the engine is not in use.
NOTE
If the engine will not be used for a period of two (2) weeks or longer, please
see the Storage section for proper engine and fuel storage.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts
necessary for your purposes.
- Select the electrical devices you plan on running at the same time.
- Total the running watts of these items. This is the amount of power you need to keep your items running.
- Identify the highest starting wattage of all devices identified in step 1.
Add this number to the number calculated in step 2. Surge wattage is the extra burst of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.
Power Management
Use the following formula to convert voltage and amperage to watts:
- Volts x Amps = Watts
To prolong the life of your generator and attached devices, follow these steps to add electrical load:
- Start the generator with no electrical load.
- Allow the engine to run for several minutes to stabilize.
- Plug in and turn on the first item. It is best to turn on the item with the largest load first.
- Allow the engine to stabilize.
- Turn on the next item.
- Allow the engine to stabilize.
- Repeat steps 5-6 for each additional item.
NOTE
Never exceed the specified capacity when adding loads to the generator.
MAINTENANCE AND STORAGE
The owner/operator is responsible for all periodic maintenance.
WARNING
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set governor will void your warranty.
WARNING
Improper maintenance will void your warranty.
NOTE
Maintenance, replacement, or repair of emission control devices and systems
may be performed by any non-road engine repair establishment or individual.
Complete all scheduled maintenance in a timely manner. Correct any issue
before operating the generator.
NOTE
For service or parts assistance, contact our help line at
1-877-338-0999
Engine Maintenance
To prevent accidental starting, remove and ground spark plug wire before
performing any service.
Oil
Change oil when the engine is warm. Refer to the oil specification to select
the proper grade of oil for your operating environment.
- Remove the oil drain plug with a 12 mm socket and extension (not included) .
- Allow the oil to drain completely.
- Replace the drain plug.
- Remove oil fill cap/dipstick to add oil.
- Add 0.4 qt. (0.4 L) of oil and replace oil fill cap/dipstick. DO NOT OVERFILL.
- Dispose of used oil at an approved waste management facility.
NOTE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw in the dipstick while
checking.
Spark Plugs
-
Remove the spark plug cable from the spark plug.
-
Use the spark plug tool that shipped with your generator to remove the plug.
-
Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.
-
Make certain the spark plug gap is 0.7 – 0.8 mm or (0.028 – 0.031 in.).
-
Refer to the spark plug recommendation chart when replacing the plug.
-
Carefully thread the plug into the engine.
-
Use the spark plug tool to firmly install the plug.
-
Attach the spark plug wire to the plug.
Air Filter
- Using your fingers, unscrew the thumb screws of the top and bottom holes of the air filter cover.
- Remove the plastic outer casing.
- Remove the foam element.
- Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth.
- Saturate in clean engine oil.
- Squeeze in a clean, absorbent cloth to remove all excess oil.
- Place the filter in the assembly.
- Reattach the air filter cover and using your fingers, insert the thumb screws into the top and bottom holes of the air filter cover. Screw until tight. Be sure not to over tighten.
Spark Arrester
- Allow the engine to cool completely before servicing the spark arrester.
- Remove the two screws holding the cover plate which retains the end of the spark arrester to the muffler.
- Remove the spark arrester screen.
- Carefully remove the carbon deposits from the spark arrester screen with a wire brush.
- Replace the spark arrester if it is damaged.
- Position the spark arrester in the muffler and attach with the two screws.
CAUTION
Failure to clean the spark arrester will result in degraded engine
performance.
Cleaning
CAUTION
DO NOT spray engine with water.
Water can contaminate the fuel system.
Use a damp cloth to clean exterior surfaces of the engine. Use a soft bristle
brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris from the engine.
Adjustments
The air-fuel mixture is not adjustable. Tampering with the governor can damage
your generator and your electrical devices and will void your warranty. CPE
recommends that you contact our service line at
1-877-338-0999 for all other service
and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our helpline at 1-877-338-0999
to locate the nearest Champion Power Equipment certified service dealer for
your generator or engine maintenance needs.
Every 8 hours or daily
| Check oil level
| Clean around air intake and muffler
First 5 Hours
| Change oil
Every 50 hours or every season
| Clean air filter
| Change oil if operating under heavy load or in hot environments
Every 100 hours or every season
| Change oil
| Clean/Adjust spark plug
| Check/Adjust valve clearance
| Clean spark arrester
| Clean fuel tank and filter
Every 3 years
| Replace fuel line
*To be performed by knowledgeable, experienced owners or Champion Power Equipment certified dealers.
Generator Maintenance
Make certain that the generator is kept clean and stored properly. Only
operate the unit on a flat, level surface in a clean, dry operating
environment. DO NOT expose the unit to extreme conditions, excessive dust,
dirt, moisture or corrosive vapors.
CAUTION
DO NOT use a garden hose to clean the generator.
Water can enter the generator through the cooling slots and damage the
generator windings.
Use a damp cloth to clean exterior surfaces of the generator. Use a soft
bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris from the generator.
Inspect all air vents and cooling slots to ensure that they are clean and
unobstructed.
Storage
The generator should be started at least once every 14 days and allowed to run
for at least 20 minutes. For longer term storage, please follow these
guidelines.
Generator Storage
- Add a properly formulated fuel stabilizer to the tank.
- Be sure all appliances are disconnected from the generator.
- Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor.
- Turn the fuel valve to the “Off” position.
- Let the generator run until fuel starvation has stopped the engine. This usually takes a few minutes.
- The generator needs to cool completely before cleaning and storage.
- Clean the generator according to the maintenance section.
- Change the oil.
- Remove the spark plug and pour about 1⁄2 ounce (14.8 mL) of oil into the cylinder. Crank the engine slowly to distribute the oil and lubricate the cylinder.
- Reattach the spark plug.
- Store the unit in a clean, dry place out of direct sunlight.
NOTE
Our engines work well with 10% or less ethanol blend fuels. When using blended
fuels there are some issues worth noting:
- Ethanol-gasoline blends can absorb more water than gasoline alone.
- These blends can eventually separate, leaving water or a watery goo in the tank, fuel valve and carburetor.
- With gravity-fed fuel supplies, this compromised fuel can be drawn into the carburetor and cause damage to the engine and/or potential hazards.
- There are only a few suppliers of fuel stabilizer that are formulated to work with ethanol blend fuels.
- Any damages or hazards caused by using improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not covered by manufacture’s warranty.
It is advisable to always shut off the fuel supply, run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days.
DANGER
Generator exhaust contains odorless and colorless carbon monoxide gas.
To avoid accidental or unintended ignition of your generator during periods of
storage, the following precautions should be followed:
- When storing the generator for short or extended periods of time make sure that the Engine Switch and the Fuel Valve are set in the OFF position.
SPECIFICATIONS
Engine Specifications
- Model . . . . . . . . . . . . . . . . . . . . . YF152FD-2-010
- Displacement . . . . . . . . . . . . . . . . . . . . . . . .80cc
- Type . . . . . . . . . . . . . . . . . . . . . . . .4-Stroke OHV
- Start Type . . . . . . . . . . . . . . . . . . . . . . . . . Recoil
Generator Specifications
- Model . . . . . . . . . . . . . . . . . . . . . . . . . . . 42436
- Running Watts . . . . . . . . . . . . . . . . . . 1200 Watts
- Starting Watts . . . . . . . . . . . . . . . . . . 1500 Watts
- AC Load . . . . . . . . . . . . . . . . . . . . . . . . . . 120 V
- Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single
- Frequency . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
- Fuel Capacity . . . . . . . . . . . . . . . . 1.5 gal. (5.5 L)
- Gross Weight . . . . . . . . . . . . . . . . 59.5 lb. (27 kg)
- Net Weight . . . . . . . . . . . . . . . . . . 52.9 lb. (24 kg)
- Height . . . . . . . . . . . . . . . . . . . 14.8 in. (37.6 cm)
- Width . . . . . . . . . . . . . . . . . . . . .14 in. (35.5 cm)
- Length. . . . . . . . . . . . . . . . . . . 17.8 in. (45.3 cm)
Fuel
Fuel capacity is 1.5 gal. (5.5 L). Use regular unleaded gasoline with a
minimum octane rating of 85 and an ethanol content of less than 10% by volume.
Oil
Use 10W-30 automotive oil.
Oil capacity is 0.4 qt. (0.4 L).
DO NOT OVERFILL.
Please reference the following chart for recommended oil types for use in the
generator.
NOTE
Weather will affect engine oil and engine performance. Change the type of
engine oil used based on weather conditions to suit the engine needs.
Spark Plugs
OEM spark plug: NHSP E6RTC
Replacement spark plug: NGK BPR6HS or equivalent Make certain the spark plug
gap is 0.7 – 0.8 mm or (0.028 – 0.031 in.).
Maintenance Valve Clearance
- Intake: 0.13 – 0.17 mm (0.005 – 0.007 in.)
- Exhaust: 0.18 – 0.22 mm (0.007 – 0.009 in.)
Note: Tech bulletin regarding the valve adjustment procedure is on www.championpowerequipment.com.
An Important Message About Temperature
Your Champion Power Equipment product is designed and rated for continuous
operation at ambient temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures ranging from -15°C (5°F)
to 50°C (122°F) for short periods. If the product is exposed to temperatures
outside this range during storage, it should be brought back within this range
before operation. In any event, the product must always be operated outdoors,
in a well-ventilated area and away from doors, windows and other vents.
Wiring Diagram
Parts Diagram
# | Part Number | Description | Qty |
---|---|---|---|
1 | 12.402.48 | Engine | 1 |
2 | 12.100001.02 | Muffler Gasket | 1 |
3 | 12.101000.02 | Muffler Assembly | 1 |
4 | 1.848.08 | Washer Ø8 | 2 |
5 | 1.93.08 | Spring Washer Ø8 | 2 |
6 | 1.6175.08 | Nut M8 | 2 |
7 | 46.101300.08 | Spark Arrester Assembly | 1 |
8 | 46.101503.08 | Plate, Spark Arrester | 1 |
9 | 1.9074.4.0514 | Bolt And Washer Assembly M5×14 | 2 |
10 | 122.070400.05 | Fuel Cock | 1 |
11 | 113.070011.02 | Pipe, Fuel (3.54 in.) | 1 |
12 | 2.06.016 | Clamp (Ø8.7×b8) | 2 |
13 | 113.070100.00 | Fuel Tank Cap | 1 |
14 | 122.070300.02 | Fuel Filter | 1 |
15 | 1.819.0510 | Screw M5×10 | 2 |
16 | 113.072000.02 | Fuel Meter Assembly | 1 |
17 | 1.5789.0620.2 | Flange Bolt M6×20 | 4 |
18 | 1.93.06 | Spring Washer Ø6 | 4 |
19 | 2.03.004 | Washer (Ø24×Ø6.5×1.5) | 4 |
20 | 122.070015.01 | Mount Vibration, Fuel Tank | 4 |
21 | 113.071000.01.48 | Fuel Tank, Yellow | 1 |
22 | 113.190007.00 | Crankcase Cover (1KW) | 1 |
23 | 1.16674.0820 | Flange Bolt M8×20 | 4 |
24 | 113.191100.06 | Rotor Assembly, Al, 58 mm, No DC | 1 |
25 | 113.191002.00 | Stator Cover | 1 |
26 | 113.191200.06 | Stator Assembly, Al, 58 mm, No DC | 1 |
27 | 1.96.08 | Washer Ø8 | 1 |
28 | 1.7244.08 | Spring Washer Ø8 | 1 |
29 | 2.08.072 | Flange Bolt M8×175 | 1 |
30 | 1.5789.0612 | Flange Bolt M6×12 | 7 |
31 | 12.100100.01 | Bracket, Muffler | 1 |
32 | 113.190002.01 | End Housing (1KW) | 1 |
33 | 1.16674.0512.2 | Flange Bolt M5×12 | 3 |
34 | 2.08.073 | Flange Bolt M6×90 | 4 |
35 | 122.190003.00.48 | Generator End Cover, Yellow | 1 |
36 | 5.1900.027 | Grounding Line, 150 mm | 1 |
37 | 1.6177.1.06 | Flange Lock Nut M6 | 1 |
38 | 1.862.06 | Lock Washer Ø6 | 2 |
39 | 6.1.032.2 | Frame | 1 |
40 | 113.201200.00 | Motor Mount, Left | 1 |
41 | 122.201400.01 | Rubber, Small | 2 |
42 | 113.201200.01 | Motor Mount, Right | 1 |
43 | 1.16674.0812 | Flange Bolt M8×12 | 2 |
44 | 203.201400.01 | Rubber, Large | 2 |
45 | 1.5783.0820 | Bolt M8×20 | 2 |
46 | 1.6177.1.08 | Flange Lock Nut M8 | 10 |
47 | 113.201200.02 | Motor Mount | 2 |
48 | 113.09.007.2 | Control Panel | 1 |
49 | 5.1010.001.1 | Ignition Switch | 1 |
50 | 5.1400.003 | Voltage Meter | 1 |
51 | 1.848.03.2 | Washer Ø3 | 4 |
52 | 1.859.03.2 | Spring Washer Ø3 | 4 |
53 | 1.6175.03.2 | Nut M3 | 4 |
54 | 5.1120.030 | Receptacle (5-20R) | 1 |
55 | 1.9074.4.0414.1 | Screw And Washer Assembly M4×14, Black | 3 |
56 | 5.1200.210 | AC 10A Breaker, Push Button | 1 |
57 | 1.5783.0622.3 | Bolt M6×22, Green | 1 |
58 | 1.6175.06.3 | Nut M6, Green | 2 |
59 | 1.93.06.3 | Spring Washer Ø6, Green | 2 |
60 | 1.97.1.06.3 | Washer Ø6, Green | 2 |
61 | 113.210002.01 | Control Box | 1 |
62 | 1.818.0512.3 | Screw M5×12, Green | 2 |
63 | 1.6177.1.04.1 | Flange Lock Nut M4, Black | 1 |
64 | 5.1860.000 | Capacitance | 1 |
65 | 122.210003.03 | Plug, End Cover | 1 |
66 | 5.1330.014 | Sheath, Wire | 1 |
67 | 122.210003.01 | Plug, Control Box | 1 |
Engine Parts Diagram
# | Part Number | Description | Qty |
---|---|---|---|
1 | 1.5789.0610 | Flange Bolt M6×10 | 4 |
2 | 12.061000.02 | Recoil Assembly | 1 |
3 | 1.16674.0612 | Flange Bolt M6×12 | 8 |
4 | 1.5789.0608 | Flange Bolt M6×8 | 3 |
5 | 12.111000.01 | Control Assembly | 1 |
6 | 12.080100.00.48 | Fan Cover, Yellow | 1 |
7 | 1.6177.2.12 | Flange Nut M12 | 1 |
8 | 12.060001.00 | Pulley Starter | 1 |
9 | 12.080001.00 | Cooling Fan | 1 |
10 | 1.16674.0620 | Flange Bolt M6×20 | 2 |
11 | 12.123000.02 | Ignition Coil | 1 |
12 | 12.120100.01 | Flywheel | 1 |
13 | 2.14.016 | Woodruff Key (5×6.5×16) | 2 |
14 | 12.080014.00 | Air Guide Plate (Back) | 1 |
15 | 12.080014.01 | Air Guide Plate (Front) | 1 |
16 | 2.11.009 | Oil Seal (Ø17×Ø30×6) | 2 |
17 | 1.276.6203 | Bearing 6203 | 1 |
18 | 21.120400.00 | Diode Assembly | 1 |
19 | 1.6177.06 | Flange Nut M6 | 4 |
20 | 2.08.037 | Bolt, Drain (M10×1.25×25) | 2 |
21 | 2.03.016 | Washer, Drain Bolt (Ø10×Ø16×1.5) | 2 |
22 | 12.030100.01(V1) | Crankcase | 1 |
23 | 12.127000.02 | Oil Level Sensor | 1 |
24 | 1.16674.0616 | Flange Bolt M6×16 | 5 |
25 | 2.03.020.1 | Washer (Ø6.2×Ø15×0.5) | 1 |
26 | 12.110100.00 | Gear, Governor | 1 |
27 | 12.110013.00 | Shaft, Governor Gear | 1 |
28 | 21.110011.00 | Clip, Governor Gear | 1 |
29 | 12.110012.00 | Bushing, Govornor Gear | 1 |
30 | 12.050103.00 | Gear, Crankshaft | 1 |
31 | 12.050101.04 | Crankshaft | 1 |
32 | 12.050102.00 | Timing Gear | 1 |
33 | 1.276.6303 | Bearing 6303 | 1 |
34 | 12.030008.01 | Gasket, Crankcase Cover | 1 |
35 | 2.04.002 | Dowel Pin Ø8×14 | 4 |
36 | 12.031000.00.48 | Oil Dipstick Assembly, Yellow | 2 |
37 | 12.030007.00 | Cover, Crankcase | 1 |
38 | 1.5789.0625.0.8 | Flange Bolt M6×25 | 6 |
39 | 12.050200.00 | Connecting Rod | 1 |
40 | 12.050005.02 | Piston | 1 |
41 | 2.09.005 | Circlip (Ø16×Ø1) | 2 |
42 | 12.050003.01 | Piston Pin | 1 |
43 | 11.050303.00 | Ring, Oil | 1 |
44 | 11.050302.00 | Ring, Second Piston | 1 |
45 | 11.050301.00 | Ring, First Piston | 1 |
46 | 12.030009.01(V2) | Gasket, Cylinder Head | 1 |
47 | 12.010100.01(V2) | Cylinder Head | 1 |
48 | 2.15.005 (E6RTC) | Spark Plug (E6RTC) | 1 |
49 | 1.5789.0855 | Flange Bolt M8×55 | 4 |
50 | 12.020002.00 | Gasket, Cylinder Head Cover | 1 |
51 | 12.021100.01 | Cylinder Head Cover (CPE) | 1 |
52 | 12.020007.00 | Baffle, Wire | 1 |
53 | 21.020001.00 | Breather Tube | 1 |
54 | 2.01.010 | Stud Bolt (M8×35) | 2 |
55 | 12.041000.01 | Camshaft (EPA) | 1 |
56 | 12.040013.00 | Lifter, Valve | 2 |
57 | 12.040005.00 | Push Rod | 2 |
58 | 12.040017.00 | Oil Seal, Valve | 1 |
59 | 12.040002.00 | Valve, Intake | 1 |
60 | 12.040006.00 | Valve, Exhaust | 1 |
61 | 12.040003.00 | Spring, Valve | 2 |
62 | 12.040014.00 | Lock Clip, Valve | 2 |
63 | 12.040200.00 | Rocker Arm Component | 1 |
64 | 1.16674.0618 | Flange Bolt M6×18 | 1 |
65 | 2.01.019 | Stud Bolt (M6×89) | 2 |
66 | 12.130002.01 | Gasket, Insulator | 2 |
67 | 12.130001.00 | Insulator, Carburetor | 1 |
68 | 12.131000.01 | Carburetor | 1 |
**** | 12.131000.02 | ||
69 | 12.091100.00 | Base, Air Cleaner | 1 |
70 | 12.091001.00 | Separator, Air Cleaner | 1 |
71 | 12.091003.00 | Element, Air Cleaner | 1 |
72 | 12.091200.00 | Cover, Air Cleaner | 1 |
73 | 12.091500.00 | Bolt, Air Cleaner | 2 |
74 | 12.080300.00 | Air Guide, Upper | 1 |
75 | 12.110001.00 | Shaft, Governor Arm | 1 |
76 | 1.896.06 | Circlip Ø6 | 1 |
77 | 2.03.019 | Washer (Ø8.2×Ø17×0.8) | 1 |
78 | 12.110008.00 | Pin, Shaft | 1 |
79 | 12.110003.00 | Arm, Governor | 1 |
80 | 12.110007.21 | Spring, Governor | 1 |
81 | 12.110005.00 | Spring, Throttle Return | 1 |
82 | 12.110006.00 | Rod, Governor | 1 |
83 | 23.120700.01 | Change Wire, Flameout | 1 |
84 | 1.5789.0612 | Flange Bolt M6×12 | 1 |
85 | 12.091000.01 | Air Cleaner Assembly (EPA) | 1 |
TROUBLESHOOTING
Problem | Cause | Solution |
---|---|---|
Generator will not start | No fuel | Add fuel |
Faulty spark plug | Replace spark plug | |
Unit loaded during start up | Remove load from unit | |
Generator will not start; Generator starts but runs roughly | Low oil level |
Fill crankcase to the proper level
Place generator on a flat, level surface
Choke in the wrong position| Adjust choke
Spark plug wire loose| Attach wire to spark plug
Generator shuts down during operation| Out of fuel| Fill fuel tank
Low oil level| Fill crankcase to the proper level. Place generator on a flat,
level surface
Generator cannot supply enough power or overheating| Generator is overloaded|
Review load and adjust. See “Power Management”
Insufficient ventilation| Check for air restriction. Move to a well ventilated
area
No AC output| Cable not properly connected| Check all connections
Connected device is defective| Replace defective device
Circuit breaker is open| Reset circuit breaker
Faulty brush assembly| Replace brush assembly (Service Center)
Loose wiring| Inspect and tighten wiring connections
Other| Contact the help line
Generator gallops| Engine governor defective| Contact the help line
Repeated circuit breaker tripping| Overload| Review load and adjust. See
“Power Management”
Faulty cords or device| Check for damaged, bare or frayed wires. Replace
defective device
For further technical support:
Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free:
1-877-338-0999
tech@championpowerequipment.com
WARRANTY
**WARRANTY*
CHAMPION POWER EQUIPMENT
3 YEAR LIMITED WARRANTY
Warranty Qualifications**
Champion Power Equipment (CPE) will register this warranty upon receipt of
your Warranty Registration Card and a copy of your sales receipt from one of
CPE’s retail locations as proof of purchase. Please submit your warranty
registration and your proof of purchase within ten (10) days of the date of
purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of
three years (parts and labor) from the original date of purchase and 270 days
(parts and labor) for commercial and industrial use. Transportation charges on
product submitted for repair or replacement under this warranty are the sole
responsibility of the purchaser. This warranty only applies to the original
purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone
or e-mail. If the problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the defective part or
component at a CPE Service Center. CPE will provide you with a case number for
warranty service. Please keep it for future reference. Repairs or replacements
without prior authorization, or at an unauthorized repair facility, will not
be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment:
Normal Wear
Products with mechanical and electrical components need periodic parts and
service to perform well. This warranty does not cover repair when normal use
has exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if the product is deemed to
have been misused, neglected, involved in an accident, abused, loaded beyond
the product’s limits, modified, installed improperly or connected incorrectly
to any electrical component. Normal maintenance is not covered by this
warranty and is not required to be performed at a facility or by a person
authorized by CPE.
Other Exclusions
This warranty excludes:
- Cosmetic defects such as paint, decals, etc.
- Wear items such as filter elements, o-rings, etc.
- Accessory parts such as starting batteries, and storage covers.
- Failures due to acts of God and other force majeure events beyond the manufacturer’s control.
- Problems caused by parts that are not original Champion Power Equipment parts.
When applicable, this warranty does not apply to products used for prime power in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time,
use of this product, freight, or any incidental or consequential claim by
anyone from using this product. THIS WARRANTY AND THE ATTACHED U.S. EPA, CARB
and/or ECCC EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) ARE IN LIEU
OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original
unit. The length of the warranty governing the exchanged unit will remain
calculated by reference to the purchase date of the original unit.
This warranty gives you certain legal rights which may change from state to
state or province to province. Your state or province may also have other
rights you may be entitled to that are not listed within this warranty.
Contact Information
Address
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670 USA
www.championpowerequipment.com
Customer Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
info@championpowerequipment.com
Fax no.: 1-562-236-9429
Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
tech@championpowerequipment.com
24/7 Tech Support : 1-562-204-1188
Champion Power Equipment, Inc. (CPE),
The United States Environment Protection Agency (U.S. EPA.) and the California
Air Resources Board (CARB) Emission Control System Warranty
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and
state of California Air Resources Board (CARB) emission regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA, California Air Resources Board, and CPE are pleased to explain the
Federal and California Emission Control Systems Warranty on your 2017 small
off-road engine and engine powered equipment. In California, new, small off-
road engines and new equipment that use small off-engines must be designed,
built and equipped to meet the State’s stringent anti smog standards. In the
other states, new engines and equipment must be designed, built and equipped,
at the time of sale, to meet U.S. EPA regulations for small non-road engines.
CPE warrants the emission control system on your small off-road engine and
equipment for the period of time listed below, provided there has been no
abuse, neglect, unapproved modification, or improper maintenance of your
equipment.
Your emission control system may include parts such as the carburetor, fuel-
injection system, the ignition system, catalytic converter and fuel lines.
Also included may be hoses, belts, connectors and other emission related
assemblies. Where a warrantable condition exits, CPE will repair your small
off-road engine at no cost to you including diagnosis, parts and labor. For
engines less than or equal to 80cc, only the fuel tank and fuel line is
subject to the evaporative emission control warranty requirements of this
section.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions
set forth below. If, during the warranty period, emission related part on your
engine is defective in materials or workmanship, the part will be repaired or
replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine owner, you are responsible for the performance of
the required maintenance listed in your Owner’s Manual. CPE recommends that
you retain all your receipts covering maintenance on your small off-road
engine, but CPE cannot deny warranty solely for the lack of receipts or for
your failure to ensure the performance of all scheduled maintenance.
As the small off-road engine owner, you should however be aware that CPE may
deny you warranty coverage if your small, off-road engine or a part has failed
due to abuse, neglect, improper maintenance or unapproved modifications.
You are responsible for presenting your small off-road engine to an Authorized
CPE service outlet or alternate service outlet as described in (3)(f.) below,
CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem exists. The
warranty repairs should be completed in a reasonable amount of time, not to
exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities,
you should contact:
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System
(ECS) Warranty Coverage.
-
APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
-
GENERAL EMISSIONS WARRANTY COVERAGE
CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent purchaser that each of its small off-road engines is:- Designed, built and equipped so as to conform to U.S. EPA emissions standards for spark-ignited engines at or below 19 kilowatts and all applicable regulations adopted by the California Air Resources Board and
- Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturer’s application for certification for a period of two years.
-
THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
- Any warranted part that is not scheduled for replacement as required maintenance in the Owners Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period.
- Any warranted, emissions-related part which is scheduled only for regular inspection as specified in the Owners Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
- Any warranted, emissions-related part which is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE according to Subsection “d” below. Any such emissions-related part repaired or replaced under the ECS Warranty, shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part.
- Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a CPE Authorized Service Outlet.
- The owner shall not be charged for diagnostic labor which leads to the determination that a part covered by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized Service Outlet.
- CPE shall pay for covered emissions warranty repairs at non-authorized service outlets under the following circumstances:
- The service is required in a population center with a population over 100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet AND
- The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New Mexico, Oregon, Texas, Utah and Wyoming.
- CPE shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty.
- Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts.
- Any CPE Authorized and approved emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not reduce CPE’s warranty obligation.
- Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty | Parts Description |
---|---|
Fuel Metering System | Fuel regulator, Carburetor and internal parts |
Air Induction System | Air cleaner, Intake manifold |
Ignition System | Spark plug and parts, Magneto ignition system |
Exhaust System | Exhaust manifold, catalytic converter |
Miscellaneous Parts | Tubing, Fittings, Seals, Gaskets, and Clamps associated |
with these listed systems.
Evaporative Emissions| Fuel Tank, Fuel Cap, Fuel Line, Fuel Line Fittings,
Clamps, Pressure Relief Valves, Control Valves, Control Solenoids, Electronic
Controls, Vacuum Control Diaphragms, Control Cables, Control Linkages, Purge
Valves, Vapor Hoses, Liquid/Vapor Separator, Carbon Canister, Canister
Mounting Brackets, Carburetor Purge Port Connector
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along
with your warranty registration card or other proof of original purchase date,
at your expense, to any Champion Power Equipment dealer who is authorized by
Champion Power Equipment, Inc. to sell and service that CPE product during his
normal business hours. Alternate service locations defined in Section (3)(f.)
above must be approved by CPE prior to service. Claims for repair or
adjustment found to be caused solely by defects in material or workmanship
will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities,
or to obtain warranty service, please write or call Customer Service at
Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>