EMPAVA 67AIS10 Freestanding Jetted Bathtub Instruction Manual

June 13, 2024
Empava

EMPAVA 67AIS10 Freestanding Jetted Bathtub

EMPAVA-67AIS10-Freestanding-Jetted-Bathtub-product

Introduction

In order to use our products safely and effectively, please read this instruction carefully. Improper installation, operation, and maintenance will cause damage to the products and charge you an extra repair fee.

  • Thank you for you to choose our massage bathtub series;
  • We provide a lifetime warranty after-sale service, please fill warranty registration form accurately;
  • If you need any help, please contact a local distributor or our company directly;
  • Our company reserves the right to change all the models listed in this instruction without prior notice;
  • This instruction applies to the listed products as below.
  • Because of the difference between the market requirements and individual custom products, please refer to the corresponding content in this instruction according to the product and its functions you choose. In this way, you can install and operate the product correctly.
  • In order to install the product correctly and safely by the installer, and you can use and maintain this product correctly and safely, please pay much attention to the warning sign below

The warning symbol’s meaning is as below:

Notice

This symbol indicates that errant handling after disregarding this symbol could result in personal injury or property loss.

  • In order to install, use, and maintain this product correctly and safely, please read and understand this instruction totally.
  • This instruction is a valuable source of product information to help the end user use the product safely and correctly. Please take good care of it and keep it from getting lost or soiled.

Preparation before installation

  • Make sure the place you install the bathtub is strong enough to bear the total weight of the bathtub, maximum water volume, and the user.
  • The waterproofing process must be made in the place of the bathtub installed, or downstairs will get damaged if water leaks.
  • The installed place must be equipped with water supply, power supply, and drainage:
    • This product uses universal home power.

Notice

  • External circuitry needs to be equipped with a highly sensitive and fast type leakage protection switch. (Induced current rating below 15MA, trip time should be less than 0.1 seconds, rated current is above 30A.)
  • The product should be installed on the grounding and electric leakage switch by ba qualified licensed electrician.
  • Please reserve the drainage hole2:111150mm, and make sure the drainage pipes accord with the water valve.
  • The user needs to reserve the connectors of 1/2′ external thread cold/hot water hoses, which outstand the wall 30mm. It is suggested to install a valve in each pipe, the location of the installation should be designed by the user, which is convenient for maintaining.
  • As each bathroom or power end drain of each bathtub is slightly different, please piece the bathtub according to the actual size. Jation, the following illustration as a reference layout:

Notice

  • The safe distance between the power supply and the water supply should be not less than 30cm.

Precautions for installation

  • Please check whether all parts are complete. If you have any questions, please give feedback to our company in time.

  • After opening the box, please immediately dispose of unneeded packaging. Or it may cause personal injury by the wooden frames, nails, cardboard or sealing straps which are placed carelessly.
    In addition, please do not let the children play with the packing material. Or it will cause personal injury.

  • Parts containing live parts, except parts supplied with safety extra-low voltage not exceeding 12 V, must be inaccessible to a person in the bath

  • Earthed appliances must be permanently connected to fixed wiring

  • Paris incorporating electrical components, except remote control devices, must be located or fixed so that they cannot fall into the bath

  • Please do not use other power, except specified power Or it may cause fire or electric shock.

  • An electrical leakage protection switch should be installed outside the bathroom. Or it may cause fire or electric shock.

  • Do not use the broken power supply, power plug or the loose socket. Or it may cause fire or electric shock.

  • Do not modify the power supply cord, use it with an extension cord or combine it with other equipment using multiple plugs.
    Doing so could lead to shocks, overheating, or fire.

  • The power needs to connect to the terminal box, and it must be operated by a qualified electrician

  • Before the installation finishes, please use cardboard to protect the bathtub or it may lead the damage to the bathtub.

  • Do not put the fire on the bathtub, such as a lighted cigarette, or it may lead the damage of the bathtub.

  • Do not stand on the bathtub while working. Doing so could cause one to slip and fall or could otherwise damage the product.

  • Install securely, in accordance with the Installation Manual. Improper installation can lead to water leaks that damage or ruin household property.

  • After finishing the installation, the product should go into trial operation fully to check whether the installation is proper or not.

Size chart

Installation instruction

Inspection before installation
Although all our massage bathtubs are water tested before they leave our factory, there may be some loose of hose connections due to the transport. We need to water test the product before installation. The steps are as follow:

  • Place the tub on a flat surface in an area where it may be drained after testing. And adjust the feet to make the bathtub level;
  • Check if there is any loss of all the connection systems;
  • Close the door, fill the tub with water to the overflow, and allow standing for 10 minutes to inspect the tub for leaks;
  • Insert the plug, start all the functions for a few minutes (which includes the functions of massage, air bubble, heater, and so on), and inspect the tub completely any defect must be reported to your dealer/distributor prior to installation in order to have it covered under warranty.

Adjust the leveling feet
According to different sizes bathtubs, we design about several leveling feet to adjust the bathtub. Please use a wrench or level ruler to level the bathtub.

Note: If the bathtub is not level, it may lead :

  • noise increased;
  • remaining water in the hoses or the drainage;
  • bathtub shaking;

Installation instruction

How to connect the water?
For ease of use, our bathtub is equipped with stainless steel cold and hot water hoses (connector o 1/2″). Please connect the cold and hot water hoses to the bathroom’s cold and hot water hoses accordingly. Before connecting the bathtub water inlet pipe, first open the water pipe for a period of time, then put filter screen to ensure that the debris will not enter the bathtub pipe. So that we can effectively extend the life of the fitting.

Insert the drain pipe to the drain hole on the floor, and then cover with a water retaining cover to prevent wastewater from spilling.

Notice

The red hose stands for hot water hose; the blue hose stands for cold water hose; the Drain-pipe should be installed with a slope above 1:50; Do not hold the drain pipe and cold/hot water hoses when moving the bathtub, and do not crash it with hard objects. How to connect the electricit Please install a proper dedicated plug with the ground electrode to the power line. And then insert the plus firmly.

Notice
It must be installed by a professional electrician

notice

  • The bathtub must be connected to the ground. The power outlet must be sealed well. Make sure the surface of each wire is intact.
  • The power connection requires a professional operation, we are not responsible for the operation by yourself The plug is with leakage protection.

Precautions for use

EMPAVA-67AIS10-Freestanding-Jetted-Bathtub-fig-17

Waist drum shape three-piece set faucet

  • cold water switch (Marked with letter C)
  • Waterfall/sprinkling style transferable switch (Marked with Icon)
  • hot water switch (Marked with the letter H)

Multi-function handheld shower with back flow protector.
Rotate the shower headshell can adjust the water pattern as follows:

  • inner water column
  • middle water column
  • external water column

Water jets use
Turning the head of water jets up, down, left or right can adjust the angle of inflow.

Hydro massage flow rate control switch

Press the center button once to start the machine, and press repeatedly to shut it down. Rotate hydro massage flow rate control switch clockwise, then the water column strength is smaller; rotate the knob anticlockwise, then the water column strength stronger. (Only for the model with hydro massage flow rate control switch)

Drainage

Manual drainage

  • When you get out of the bathtub, step on the drain cover and press it down next time.
  • When the water is over the maximum water level, the excess water will be drained by overflow.EMPAVA-67AIS10-Freestanding-Jetted-Bathtub-fig-16

Care and Maintenance

EMPAVA-67AIS10-Freestanding-Jetted-Bathtub-fig-18

Regular care of your bathtub will keep it clean and working at its best.Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. Below are the recommended procedures for cleaning:

  1. Do not run the jet massage system dry;
  2. Fill the tub with hot water(about 40 C) 2-3 cm above the jets and add 2-3 teaspoons of low foaming detergent such as dishwashing machine detergent;
  3. Turn on all the functions and run for 10 minutes;
  4. Drain tub completely;
  5. Fill tub with cold water above jets:
  6. Turn on all the functions and run for 15 minutes;
  7. Drain tub completely;
  8. Cleaning the “suction cover”: Clean and remove any hair or lint from the suction cover. On a monthly basis, unscrew the suction cover and clean away any hair, lint or debris from the cover and housing, then remount the cover in place. Some suctions are not designed to be removed; only suctions that have screws on the cover, visible from the inside of the tub, can be removed.

Notice Never operate the unit with the safety suction cover off

Troubleshooting Guide (Form two) EMPAVA-67AIS10-Freestanding-Jetted-
Bathtub-fig-19

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Empava User Manuals

Related Manuals