genie products AC2500 BioMerge Minimum PC Instruction Manual

June 13, 2024
genie products

genie logo BioMerge Manual
Version 2.01

Bioaccess Sales Limited,
Caxton Point Business Centre, Caxton Way, Stevenage, SG1 2XU, United Kingdom

Hardware / Soware Requirements

Minimum PC Specificaon:
Intel® i5 4th genera on or higher
4GB RAM or greater
Minimum 20GB free disk space
256 colours @ 1024 x 768
Physical Ethernet and USB port
Operang System:
Windows 11
Windows 10 Pro 32 + 64 Bit
Windows 8 32 + 64 Bit
Windows 7 32 + 64 Bit
Windows Server opera
ng systems are not supported.
Virtual Machine environments are not supported.
Paxton Version:
V5.00 and above.
Virdi Products:
AC5000-SC Firmware – 10.51.03-000.36
AC5000-SC Firmware – 30.62.01-000.09 (Non PoE)
AC2500-SC Firmware – 30.51.09-000.02
AC2200-SC Firmware – 10.61.00-000.35
AC2000-SC Firmware – 10.61.00-000.06
ACF100-SC Firmware – 11.51.04-000.10
Newer firmware versions, and non-Genie sourced variants may work but have not received a full evaluaon.

SYSTEM OVERVIEW

genie products AC2500 BioMerge Minimum PC - SYSTEM
OVERVIEW

Peripheral Required
Enrolment Reader Yes
Connection Required
Network Yes
Wigand Yes
Power Yes

Configuraon And Setup Requirements

Wiegand
You must interface the Virdi terminals and Net2 ACU’s physically, just as a standard RFID reader and controller are.
As with all Wiegand interfaces the Ground of the Reader must Connected to the Ground of the Access control Panel.
On Virdi Devices that’s OUT0, OUT1 and GND
On Net ACUs that’s Data/D0, Clock/D1 and 0Vgenie products AC2500 BioMerge
Minimum PC - SYSTEM OVERVIEW Wiegand format
The Wiegand Output of the Virdi Terminal needs to be enabled and match the Net2 ACU’s configuraon.
Using Net2’s default 26 Bit format will mean that the interfaced terminal will need its Wiegand output set to 26bit.
When using the AC2000, Unis-B Plus mobile app or Unis remote manager is used to enable 26bit Wiegand out in the sengs. Once enabled, you can uninstall Unis Remote manager.
Power
The Virdi terminal should be powered from the PSU supplied or PoE if it is a compliant device.
Network
Virdi Terminals require connecon to the LAN. They require a unique IP (Dynamic or Stac), the Servers IP address and a Terminal ID, for example 1.
Terminal Card reader settings
AC2500: HEXA_2
AC5000: HEXA
Enrolment Reader
Systems Running BioMerge2 Client need a Virdi FOH02SC a ached via a physical USB port.
Net2 Door / Reader Configurationgenie products AC2500 BioMerge Minimum
PC - SYSTEM OVERVIEW 2

BIOMERGE SOFTWARE OVERVIEW

BioMerge 2 consists of two programs, Server & Client.
Server
The Server program must be installed on the Paxton server, Virdi Terminals can be added to the system and maintained. The server program sends user informa on to the Virdi terminals and is the link between Paxton Net2 and the Virdi terminal(s).
Client
The Client program needs to be installed on Paxton client PC’s or on Paxton server PC’s in the case of when installations of the Paxton server PC is also used for enrolment purposes. The client program is used for enrolment / modification of Users and their authenticatoon types in relation to Virdi terminals.genie products AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW
3NB .Please Note that both BioMerge2 Server and BioMerge2 Client are a License based system (more information on licensing on page 9 of this manual)
Installation
After unzipping the Biomerge compressed file, open the .autorun folder and select autorun.exe, you will then be presented with the window below.genie
products AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW 4

Server
Click the Install Server Button
An Information window will pop up stating that SQL 2012 ( A dependency of Biomerge) needs to be installed.
Select the Install button and the Installation will commence, the length of time the install takes will depend on your system specification, it can take over 10 minutes for Microso SQL Server 2012 Express Sp2 to install.
Once the prerequisite installation is complete the BioMerge2 Sever Install window will appear on screen.
Click the Next> button followed by the Install button when the next screen appears.
When the Install is complete click the Finish button.
Server is now ready to run for the first time.
It is in C:\Program Files (x86)\Genie CCTV\BioMerge2 Server
To create a shortcut on your desktop right click the BioMergeServer application and select Create shortcut.
In scenarios where the Net2 Server is separate from the client system, it’s recommended that BioMerge2 Server is configured to start via a task that runs at start up.
Client
Click the Install Client button.
The BioMerge2 Client install window will appear on screen.
Click the Next> button followed by the Install button when the next screen appears.
When the Install is complete click the Finish button.
Click the Install Desktop Reader Button (This installs the Drivers for the Virdi Enrolment reader FOH02SC)
An InstallShield Wizard window will appear on screen.
Click Next> When the Install is complete click the Finish button.
Client is now ready to run for the first time.
It is located in C:\Program Files (x86)\Genie CCTV\BioMerge2 Client
To create a shortcut on your desktop right click the BioMergeClient application and select Create shortcut.
Licensing
Licensing is managed on a per system basis, if Server and Client are installed on a single system then only one license is required, however, if they are installed on two separate systems then two licenses are required. Server and client systems are individually licensed.
After running Server or Client for the first me, the window below will appear on screen.  genie products AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW
5Please contact the technical team at Bioaccess Sale Limited (Genie) for License Keys, the terminal serial number and the Installation ID are required so that a License Key can be produced.
Once the License Key is entered, select Save License.
The Program you have licensed will then run.
NOTE: Biomerge is an annual based license that is free to customers who purchase Virdi terminal(s) sourced from Bioaccess Sales Limited (Genie), terminal(s) not sourced from Bioaccess Sales Limited (Genie) will require an annual license fee.
SERVER
After licensing, the first time BioMergeServer runs the window below will appear on screen, this is because BioMergeServer needs the login details of the Net2 server System engineer account.genie products AC2500 BioMerge
Minimum PC - SYSTEM OVERVIEW 6To enter the information that BioMergeServer needs in order to communicate with Net Server expand system tray and right click the Orange Square with the letter ‘S’ Icon, then select Edit Net2 Settings. Enter the Password for the Net2’‘System enginee’ account and in the blank fields of the Settings window. Enter a time in the Blank field under Backup Schedule , a backup will be writtien
daily to C:\Bio-Merge backups at the specified time.
Click OK on the settings window and then OK on the database message window. Restart BioMergeServer.genie products AC2500 BioMerge Minimum PC - SYSTEM
OVERVIEW 7To add a terminal to the server open ports 9870 ~ 9875 for TCP and UDP on the PC’s firewall.
Under the terminals network configuration settings, set the Server IP address field to the IP address of the Net2/BioMerge server computer.
Please note that a terminals IP address and ID also need to be configured. Please refer to the relevant terminal installation manual (downloadable from https://genieproducts.co.uk) for more information.
Newly Configured Terminals will appear in the Server Console as illustrated below. genie products AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW
8Click the new terminal and the small configuration window as below will appear on screen. Enter a name for the terminal and its capacity, for example an AC5000 has a capacity of 20000 finger templates.
Once added to the server a door Icon will appear next to the terminals Name in the ID column this Icon will appear greyed out if the terminal is, for whatever reason, disconnected from the Server.
genie products AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW
10 SERVER CONSOLE genie
products AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW 11Remove Terminal
Deletes a Selected terminal.
Resend All Users
Sends all enrolled users to a selected terminal.
Delete All Users
Deletes all users from a selected terminal.
Assign All Users
Assign all Users in the Biomerge database to a selected Terminal
List Users
List all users associated with a selected Terminal
Upload File
Sends a customized file to a selected Terminal, for example a background image for an AC5000.
Upload Firmware
Upload firmware to a selected Terminal
Backup Database
Allows users to manually create a backup of the Biomerge database to location of choice outside of the scheduled backup time.
Edit Net2 Settings
Net2 Server address/ name, Login details and Schedule settings for BioMerge2 database backup.
License Key
Displays License Key and its validity.
View Events
Lists event information, such as enrolment and deletion of users, the list refreshes when the server is restarted.
Remote Help
Reserved function for future releases that will offer fast remote support via a remote desktop session with a Genie technician.
Hide
Minimizes the Server Console to the system tray.
The system Tray Icon has two states .
System Tray Icon
Orange
The Server is starting and initiating database and network connections.
Green
The server has started successfully making all required database and network connections.
Right clicking the system tray Icon will give access to the following options/settings.
Show
Shows the Server Console window.
Edit Net2 Settings
Net2 Server address/ name, Login details and Schedule settings for BioMerge database backup.
Edit License
Displays the License Key and its validity.
Remote Support
Reserved function for future releases that will offer fast remote support via a remote desktop session with a Genie technician.
Backup Database
Allows users to manually create a backup of the Biomerge database to location of choice outside of the scheduled backup time.
Quit
Closes and stops the BioMerge2 server from running.
Client
After licensing and the first time BioMergeClient runs, the window below will appear on screen, this is because BioMergeClient needs connection details for the Net2 and BioMerge2 Server.![genie products AC2500 BioMerge Minimum PC

To enter the information that BioMergeClient needs to enable communication with the
BioMergeServer, expand the system tray and right click the Orange Square Icon displaying the letter
‘C’ then click Settings. Enter the Servers Name and the Net2 System engineer Username and Password in the blank fields of the Settigs window.
Click OK on the settings window and then OK on the database message window.
Restart BioMergeClient.
The system tray icon has two states,
Orange

The Client is startting and in itiitiating network connections.
Green
The Client has started successfully making required network connections.
Right clicking the system tray Icon will give access to the following options/settings.
Show
Shows the Server Console window
Settings
Net2 Server address/ name, Login details and Schedule settings for BioMerge2 database backup.
Enable / disable Net 2 Lockdown mode setting, this mode only needs to be selected when using the security Lockdown feature in Net2 Pro.genie products
AC2500 BioMerge Minimum PC - SYSTEM OVERVIEW 13

Edit License
Displays the License Key and its validity.
Remote Support
Reserved function for future releases that will offer fast remote support via a remote desktop session with a Genie technician.
Quit
Closes and stops the BioMerge2 server from running.
Enrolment
The client will remain minimized to the system tray until enrolment is initiated.
To start enrolment, add a new user in Paxton Net2 access control software.
There are requisite fields that must be completed at this stage for the BioMergeClient to function.
They are as follow.
First name
Surname
Access Level – No access is NOT VALID.
Token number – Maximum supported Token number 65535 when using Net2s default Wiegand 26bit format.
Token type – Fingerprint verification card needs to be selected.
After the user is added in Net2 access control the BioMerge desktop client will pop up on Screen.
On the left under terminals, select the terminals you wish to send the users(s) credentials to.
In the middle under token tick admin if the user is to be a terminal admin user. Once a terminal admin user is sent to the terminal(s), access to those terminal(s) settings will be locked to admin users only.
On the right select the desired Authentication Type, Present a card to the enrolment reader and/or enter a Pin Number as per the Chosen Authentication type then Click Enrol
BioMerge2 Desktop Clientgenie products AC2500 BioMerge Minimum PC -
SYSTEM OVERVIEW 14 Terminals
Lists all Virdi Terminals that are connected to the Server and displays Usage, how many users are on the device. The Tick box under the ID column is used to tell server what Terminals to send a User to.
Ticking select All will select all terminals.
Admin tick box
Ticking this sets users to Admin on Virdi terminals, it is recommend that at least one user is set as admin to secure the Virdi terminals local configuration menus.
Authentication Type
There are nine authentication types to choose from. They are Fingerprint, Pin Number, Card and combinations of the three.
Fingerprint Registration Level
This is set to highest by default and is the recommended level that is used.
Authorisation Level
Here a User’s Fingerprint authorisation level can be changed.
1:N
One to Many authentica
on- the terminal will check all data until it finds a match to the presented.
1:1 the Data to check is specified by entering a user ID before presenting a print.
Card Number
Card numbers appear in this box during enrolment.
PIN
Pin numbers are entered here up to a maximum of 8 digits.
Editing Users
There are scenarios where a user’s settings need to be modified, good examples of this include changing Authentication Type and/or the changing Authentitia on Level.
To edit a user in the BioMerge2 Desktop Client right click the users Fingerprint Verification Token in Net Access Control and select fingerprint verification card followed by apply this will cause the client to popup on screen.
BioMergeRecoveryTool
The BioMerge Recovery tool is located in C:\Program Files (x86)\Genie CCTV. It is used to restore backups of the BioMerge2 database. Please be aware that doing this will overwrite / erase all existing data. genie products AC2500
BioMerge Minimum PC - SYSTEM OVERVIEW 15

Trouble shooting

Problem
The Biomerge2 Client Console doesn’t appear on screen after adding a User to Net2 Access Control.
Solution
Check the user has Access rights configured and/or their Token Type is Fingerprint verification card.
Check the system tray icon is Green if not check Settings, for example, the Paxton password may have been changed during commissioning.
Check that the Server Name and Net2 Site Name match.
Problem
Users are Enrolled and sent to the server but cannot authenticate at terminals.
Solution
Check that BioMerge2 Server is running.
Check via the Server console that the affected Terminal(s) are online.
Problems
Biomerge Server Console is not function correctly and the system tray icon is orange.
Solutions
Check the system has a functioning network connection.
Check the Net2 Logon details are correct under Net2 Settings.
Check the SQL Instance BIOMERGE is Running.
For further support please contact Genie Technical Support on 01707 330 541 (option 2) or email technical@genieproducts.co.uk.genie
logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals