Gardus 181744000423 SnugDryer Space Saving Dryer Vent Connection Kit Instruction Manual
- June 13, 2024
- Gardus
Table of Contents
Gardus 181744000423 SnugDryer Space Saving Dryer Vent Connection Kit
Installation Components
-
Dryer Vent Adapter (1)
-
Wall Assembly (1)
-
Hose Clamps (2)
-
Wall Anchors (4)
-
Screws (4)
Installation Instructions
-
Line up dryer vent pipe with existing exhaust duct work. If the ductwork and exhaust pipe do not line up, reroute ductwork to the wall directly behind the dryer. Patch and finish drywall.
-
Install Dryer Vent Adapter to dryer’s exhaust vent with included hose clamp. Adjust dryer feet to match washer height. Push dryer into position until Dryer Vent Adapter leaves a circular impression on the wall.
-
Cut white circle from the installation template on the bottom of the box. Align with wall marks and mark screw holes.
-
Cut yellow-green circle from template. Realign template and trace circle onto the wall. Cut traced circle and remove drywall. Drill 5/16″ holes at marks from step 3 and insert drywall anchors.
-
Connect Wall Assembly to roughed-in flex duct with included hose clamp. Screw assembly into drywall anchors.
-
Slide dryer to the wall ensuring the Dryer Vent Adapter is aligned with the Wall Assembly, until the adapter ‘pops’ through the seal. The connection and installation are complete!