ELEMENTI OFG110-NG Boulder Round Concrete Fire Pit Table Owner’s Manual

June 13, 2024
ELEMENTI

ELEMENTI OFG110-NG Boulder Round Concrete Fire Pit Table Owner’s Manual

OFG110

Gas type: Natural Gas

IMPORTANT

SAVE THESE INSTRUCTIONS

WARNING

For outdoor use only. DO NOT use for cooking. DO NOT use under any overhead enclosure.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage personal injury or loss of life.

Installation and service must be performed by a qualified installer, service agency or gas supplier.
Improper Installation, adjustment, alteration, service or maintenance can cause injury or property damage.

Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment.

Save these instructions for future reference. If you are assembling this unit for someone else, give this manual to him or her to read and savefor future reference.

DANGER

If you smell gas:

  1. Shut off gas to the appliance.
  2. Extinguish any open flame.
  3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.

WARNING

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
This unit is not for use with propane. Use only with Natural gas.

WARNING

California Proposition 65:
Combustion by-products produced when using this product contain chemicals known to be State of California to cause cancer, birth defects, and reproductive harm.
Wash your hands after handing this product.
Handing the brass material on this product exposes you to lead, a chemical known to the State of California to cause cancer, birth defects, or reproductive harm.

IMPORTANT SAFETY INFORMATION

WARNING FIRE TABLE IS FOR OUTDOOR USE ONLY

IF YOU SMELL GAS

  • Shut off gas supply to the fire table.
  • Extinguish any open fame.
  • Do not try lighting any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone.
  • Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners, and circulating air passageways of the appliance are kept clean.

  • WARNING: Always shut off gas supply at the shut-off valve and disconnect the quick disconnect socket from the main gas supply when the fire table is not in using.
  • WARNING: Installation and service must be performed by a qualified installer, service agency or gas supplier.
  • WARNING: Failure to follow with the safety warnings and precautions in this manual may result in serious bodily injury or death, a fire or an explosion causing damage to property.
  • IMPORTANT NOTICE: Read and understand all warnings and precautions prior to assembly and use your gas fire table. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • NOTE: The use and installation of this product must conform to local codes. In the absence of local codes, use the National Fuel Gas Code, ANSI Z21.97. Reference to Natural Gas and Propane Installation code CSAB149.1 or Propane Storage and Handling code B149.2.
  • NOTE: When an appliance is for connection to a fixed piping system, the installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or International Fuel Gas Code.
  • Minimum clearance from unit to combustible materials 72” (182.9cm) from the top; 48” (121.9 cm) from all sides and back. Do not locate this fire table under any overhead enclosure.
  • Always use this outdoor fire table on a hard, level non-combustible surface such a concrete, rock or stone. An asphalt or blacktop surface may not be acceptable for this purpose. Surfaces such as dirt and grass may prevent the unit from having proper ventilation.
  • This gas fire table and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 of psi
  • (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Keep these instructions for future reference. If you are assembling this unit for someone else, give this manual to him or her to read and keep for f utu re reference.
  • This gas fire table must be used ONLY outdoors in a well-ventilated space and shall NOT be used inside a building, garage, or any other enclosed area.
  • DO NOT use this outdoor gas fi re table for indoor heating. Toxic carbon monoxide fumes can accumulate and cause asphyxiation.
  • NEVER leave this gas fire pit unattended when in use.
  • Children should be alerted to the hazards of high surface temperatures and kept at a safe distance while fire table is in use.
  • DO NOT store or use gasoline or other flammable vapors and liquids within 25 feet (7.62m) ofthis or any other appliance.
  • DO NOT store any combustible materials in the baseenclosure.
  • DO NOT use in an explosive atmosphere. Keep gas fire table area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
  • This outdoor fire table is NOT to be operated by children. Young children should beclosely supervised when in the vicinity of this outdoor firetable.
  • This outdoor fire table is not to be installed or used in or on recreation vehicles and/orboats.
  • Always use in accordance with all applicable local, state and national codes. Contact your local fire department for details on outdoor burning.
  • Use the same precautions you would with any open fire when using this outdoor firetable.
  • DO NOT burn solid fuels such as: wood, charcoal briquettes, lump charcoal, manufactured logs, driftwood, trash, leaves, paper, cardboard, plywood, painted orstained or pressure treated wood in this outdoor fire table.
  • DO NOT use this outdoor fire table until it is completely assembled and all parts aresecurely fastened and tightened.
  • DO NOT use this outdoor fire table near automobiles, trucks, vans or recreationalvehicles.
  • DO NOT use this outdoor fire table under any overhead structure or near anyunprotected combustible constructions. Avoid using near or under overhanging trees and shrubs.
  • The use of alcohol, prescription or non-prescription drugs may impair an individual’s abilityto properly assemble or safely operate this outdoor firetable.
  • DO NOT use this outdoor fire table if any part has been under water. Immediately call a qualified service technician to inspect the fire table and to replace any part or control system and any gas control which has been under water.
  • DO NOT wear flammable or loose clothing when operating this outdoor fire table.
  • DO NOT use in windy conditions.
  • Keep all electrical cords away from a hot outdoor fire table.
  • Certain areas of this outdoor fire table when in use will become too hot to touch. Do not touch hot surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot holders or heat resistant gloves or mittens to avoid burns.
  • DO NOT hang or place clothing or other flammable materials on or near the gas fire table.
  • Any guard or other protective device removed for servicing the fire table must be replaced prior to operating the fire table.
  • DO NOT attempt to move or store this outdoor fire table until all part s are cool.
  • DO NOT lean over this outdoor fire table when lighting or when in use.
  • Use only the natural gas hose and quick disconnect assembly provided. The replacement natural gas hose and quick disconnect assembly shall be that specified by the manufacturer.
  • DO NOT attempt to disconnect natural gas hose or quick disconnect socket from the main gas supply or any gas fitting while the outdoor fire table is in use.
  • Always shut off the gas s upply at the shut-off valve and disconnect the quick disconnect socket from the main gas supply when the fire table is not in use.
  • DO NOT sit on the fire table when the unit is in operation.
  • DO NOT throw anything onto the fire when the unit is in operation.
  • Lava rocks are very hot; please keep children and pets at a safe distance.
  • It is essential to keep the outdoor fire table valve compartment, burners, and circulating air passages clean. Inspect outdoor fire table before each use.
  • Prior to each fire table operation, check the hose for evidence of excessive abrasion or wear by looking through the visual check hole. If the hose is damaged,cracked or cut, it must be replaced before using the gas fire table. The hose assembly can only be replaced with a hose assembly specified by the manufacturer. Please call Elementi at 800-678-7294 .
  • Before each use, remove the lava rocks. Examine the burner and its components. If dirty, clean with a soft brush and soapy water solution. Examine the area around the burner; any dirt or foreign material, such as spider webs or nests in this area should be removed. If it is evident that the burner is damaged, the fire table must not be used. The burner assembly cannot be replaced. Please contact Elementi at 800-678-7294 for technical support.
  • Place the hose out of the pathways where people may trip over it. Do not place the hose in areas where it may be subjected to accidental damage.

WARNING

This outdoor fire table is for use with Natural Gas only. The conversion to or attempted use of Liquid Propane in this outdoor fire table is dangerous and could result in serious personal injury, or property damage.

ATTENTION: Any alteration of the outdoor fire table that is not specifically directed in the operations manual will void manufacturer warranty.

NATURAL GAS DANGERS AND WARNINGS

Natural gas is flammableand hazardous if handledimproperly. Become aware of the characteristics before using any natural gas product.

Natural Gas Characteristics:

  • Flammable, explosiveunder pressure, lighter than air and settles in pools in high areas.

  • In its natural state, natural gas has no odor. For your safety,an odorant has been added.

  • Contact with natural gas could burn the skin.

  • Natural gasisextremelyflammableandhazardousifhandledimproperly.
    Chemicals known to the state of California to cause cancer, birth defects, or other reproductiveharm arecreated by thecombustion ofnatural gas.
    Your natural gas fire pit is designed to operate on natural gas only, at a pressure of seven inches’ water column (7″ W.C.) Check with your gas utility forlocal gas pressure, because in some areas natural gas pressure varies. Also, check with your gas company or with local building codes for instructions to install gas supply line, or call a licensed and qualified installer.
    It is recommended that an ON/OFF manual shut-off valve be installed at the gas supply source:

  • Outdoors after the gas line exits outside wall and before quick-disconnect or before gas supply line enters ground.

  • Indoors in the branch gas line in an accessible location near the gas supply line.
    Pipe sealing compound or pipe thread tape of the type resistant to the action of natural gas must be used on all male pipe threads. Apply compound or tape to at least the first three to four threads when making aconnection.

Never store or use gasoline or other volatile substance in the vicinity of this fire table.

Natural Gas Connection
Connect a manual shut-off valve to gas supply line. Apply sealing compound or pipe thread tape of the type resistant to the action of natural gas on all male pipe threads. Connect the end, with the quick release connector, or the natural gas hose to manual shut-off valve at the gas supply.

WARNING

During any high pressure testing of the gas supply piping system at test pressures in excess of ½ psi (3.5 kPa), the appliance and its individual shut- off valve must be disconnected from the gas supply piping system.

The outdoor fire table must be isolated from the gas supply piping system by closing the individual manual shut-off valve during any pressure testing of the gas supply piping system at least equal to or less than 1/2 psi (3.5 kPa).

WARNING

Burner valves are pre-tested at the factory to operate on natural gas. Do not attempt to convert or change.

PARTS LIST

ASSEMBLY INSTRUCTIONS

PRE-USE INSTRUCTIONS

WARNING Before using this outdoor fire table, make sure you have read, understand and are following all information provided in the Important Safety Information section of this manual. Failure to follow those instructions can cause death, serious injury or property damage.

Prior to each gas fireplace operation, check the hose and valve for evidence of excessive abrasion or wear though the visual check hole on the side of the base. Replace visual check cap prior to operating fireplace.

BURNER CONNECTIONS
Make sure the regulator valve and hose connections are securely fastened to the burner and the tank. If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.

WARNING

Failure to inspect this connection or follow these instructions could cause a fire or an explosion, which can cause death, serious bodily injury, or damage to property.

Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please contact Elementi at 800-678-7294 for assistance.

Checking for Leaks
Make a leak check solution by mixing 1-part dishwashing soap with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, turn natural gas on at its source.
Spray leak solution on valve connections paying particular attention to the areas indicated by arrows.
If any bubbles appear turn natural gas off, reconnectand re-test. If you continue to see bubbles after several attempts, disconnect natural gas source and contact Elementi at 800-678-7294 for assistance.
If no bubbles appear after one-minute turn source OFF, wipe away solution and proceed.

LIGHTING INSTRUCTIONS

Using the Ignitor

  1. Read and understand all operating instructions before lighting.
    Ensure that all protective film has been removed from stainless burn tray prior to lighting.

  2. Burner control knob must be in the “OFF” position.

  3. Connect natural gas source (see above pages).

  4. Open the natural gas supply to the unit.

  5. Push and hold igniter but t urn to create sparks.

  6. While holding the igniter button with one hand, use your other hand to push and turn the control knob to the “LIGHT” position to light the burner.

  7. Keep the burner control knob pressed in for 15-30 seconds after ignition.

  8. If ignition does not occur in 30 seconds, turn control knob to the “OFF” position and turn gas off at the source, wait 5 minutes until gas has cleared and repeat lightingprocedure.

  9. After lighting, rotate the burner control knob counter clockwise to “Low” setting. Observe flame, make sure all burner ports are lit. Flame height should be no higher than 13 inches tall.

  10. Adjust the flame to the desired height with the control knob.


Using a Long Match or Lighter

  1. Prior to lighting, use a shovel to move lava rocks for access to the burner.
  2. Wearing heat resistant gloves, position the burning long match or burning butane lighter near the side of the burner. DO NOT lean over the fire table while lighting!
  3. Turn control knob counterclockwise to “LIGHT”.
  4. Remove long match/long butane lighter.
  5. After lighting, use a shovel and heat resistant gloves to carefully move the lava rocks back into their proper position and replace the glass panel.
  6. After lighting, rotate the burner control knob counter clockwise to “Low” setting. Observe flame, make sure all burner ports are lit. Flame height should be no higher than 13 inches tall.
  7. Adjust the flame to the desired height with the control knob.

WARNING

If burner fame goes out during operation, immediately urn the control knob “OFF” and let the gas clear a minimum of 5 minutes before attempting to re- light the fire table.

Please refer to the trouble shooting pages for additional support,

WARNING

When using this method to light your fire table use heat resistant gloves and follow the step by step instructions.
Failure to do so could result in severe injury.

WARNING

DO NOT wear loose or flammable clothing while lighting fire table.

CARE AND CLEANING

Inspecting
This outdoor fire table must be inspected regularly to insure that the product is safe to use and to extend product life.

WARNING

DO NOT inspect this outdoor fireplace until the fire is COMPLETELY out.

  1. Check the burner to make sure it is securely in place.
  2. Check all gas connections for leaks.
  3. Check ignition system to insure proper sparking.
  4. Check components for any signs of damage, rust or excessive wear.
  5. If damage to any component is detected, DO NOT operate until the proper repairs have been made.

WARNING

DO NOT tamper with this appliance. This is DANGEROUS and will void the warranty. Any part found to be faulty must be replaced with an approved part, confirmed by manufacturer. For technical support contact Elementi at 800-678-7294 .

General Care and Cleaning
This outdoor fireplace should be cleaned regularly to ensure safe use and extend product life.
Note: After repeated use, a slight discoloration of the finishes may occur.

Table
1. Wipe exterior surfaces with a mild dish washing soap or baking soda, then rinse clean with water.

Stainless Steel

  1. For general cleaning use warm water, soap, ammonia, or detergent apply with a soft cloth or Sponge
  2. For finger prints or smears use 3M Stainless Steel Cleaner and Polish, Arcal 20, Lac-O-Nu, LuminWash, O’Cedar Cream Polish, or Stainless Shine, this will provide a barrier file to minimize fingerprints.
  3. For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish, Allchem Concentrated Cleaner, Samae, Twinkle, Cameo Copper Cleaner, Liquid Nu Steel, Copper’s or Revere Stainless Steel Cleaner, apply using a soft cloth in the same direction of the polish lines.
  4. While using in salt air environments we recommend cleaning all stainless steel surfaces at least every two weeks to keep the item in prime condition. Stainless steel is corrosion-resistant but it is not impervious to rust.

Exposure to salt air and sea spray will cause surface rust if you do not care for your products properly.
The best thing you can do to protect the stainless steel is to clean it frequently.

  • Use of proprietary names is intended only to indicate a type of cleaner and does not constitute endorsement. Omission of any proprietary cleanser does not imply its inadequacy. All products should be used in strict accordance with instructions on package.

Storage

WARNING

DO NOT move or store this fire table unless the fire is COMPLETELY out and cool to the touch.

  1. Turn gas OFF at tank connection. Remove tank and store in a cool, dry location outdoors, away from children.
  2. Carefully remove rock filler and store components flat to protect them from breakage.
  3. ALWAYS cover your outdoor fire table when not in use with the cover provided with the unit.
  4. Store in a cool, dry location away from children and pets.

GAS COMPONENT CONNECTION CHECKS

If the burner will not light or stay lit, please perform the following checks.

  1. Make sure the electrode wire is correctly connected. Both electrode wires must be fully inserted into the igniter box.

2. Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris between the igniter pin, thermocouple and the burner tube.

3. Make sure that the igniter pin and thermocouple are correctly positioned.
– The igniter pin should be pointed straight to the thermocouple.
– The thermocouple should be positioned 5mm / 0.196” away from the burner tube.

4. Make sure that the thermocouple wire is correctly positioned. The thermocouple wire should be in line with the valve.

TROUBLESHOOTING

Problem: Burner will not light using igniter

Possible Cause 1: Electrode and burners are wet.
-Wipe dry with cloth.
Possible Cause 2: Igniter battery is dead or backwards.
-Check that the AAA battery is inserted correctly in the igniter (see page 8) or replace the battery.
Possible Cause 3: Igniter Pin cracked or broken – sparks at crack.
-Call Elementi at 800-678-7294 for technical support.
Possible Cause 4: Wire loose or disconnected.
-Reference page 16, step 1, reconnect wire. Call Elementi at 800-678-7294 .
Possible Cause 5: Wire is shorting (sparking) between igniter and electrode.
-Call Elementi at 800-678-7294 for support.
Possible Cause 6: Igniter Pin not pointing at thermocouple.
-Reference page 16, turn electrode to point at the thermocouple.
Possible Cause 7: Bad Igniter.
-Call Elementi at 800-678-7294 for supporting.

Problem: Burner will not light with match Igniter Pin

Possible Cause 1: No Gas Flow.
-Check if the LP gas tank is empty. If empty, replace and refill. If the propane tank is not empty, refer to “Problem: Sudden drop in gas flow” on the following page.
Possible Cause 2: Coupling nut and regulator not fully connected.
-Turn the coupling nut about one half to three fourths a turn, until you feel a solid stop. Do not use tools, tighten by hand only.
Possible Cause 3: Obstruction of gas flow.
– Check for bent or kinked hose.
Possible Cause 4: Spider webs or insect nest in the Air mixer.
– Clean the Air mixer.
Possible Cause 5: Burner ports clogged or blocked.
-Reference “Problem: Irregular flame pattern” on the following page. Clean the burner ports as described there.

Problem: The Fire Table emits a lot of black smoke when in use
Possible Cause 1: Hose from gas fireplace is pinched.
-Make sure the hose is not pinched between the fire table and the source of the gas.
Possible Cause 2: Flame is being obstructed at burner ports.
-Make sure that the gas ports on the burner are free of any lava rocks so that the flame can flow naturally.

Problem: Sudden drop in gas flow, or a reduced flame height

Possible Cause 1: Out of gas.
-Call your local gas company.
Possible Cause 2: Excess flow safety device may have been activated.
-Turn control knob to “OFF”, wait 30 seconds and light outdoor fire table. If flames are still too low reset the excessive flow safety device by turning off the control knob and the gas supply.
Disconnect the quick disconnect socket.
Turn Burner Control Knob to “HIGH”. Wait 1 minute.
Turn Burner Control Knob off.
Reconnect the quick disconnect, turn on the main gas supply and perform a leak check at the Natural Gas connection.

Problem: Irregular flame pattern,flame does not run the full length of the burner
Possible Cause: Burner ports are clogged or blocked.
-Clean burner ports. Do this by inserting a paperclip into each of the burner ports to ensure they are not clogged.
WARNING: Make sure burner is not on and the gas supply has been properly disconnected. Allow 15 minutes for unit to cool before touching it.

Problem: Flame blow out
Possible Cause 1: High or gusting winds.
-Increase flame to “HIGH” setting.
Possible Cause 2: Low on Natural gas.
-Call your local gas company.
Possible Cause 3: Excess fl ow valve tripped.
-Refer to “Problem: Sudden drop in gas flow”.

Warranty

Ocean Rock USA LLC doing business as Elementi, warrants Elementi fire features and accessories to be free from defects in parts and workmanship under normal use and service for a period of 1 year from the date of purchase. In the event of such defects Elementi will, at its option, repair or replace the defective product. The foregoing is at the discretion of Elementi.

There will be no charge for the replacement parts or product, however it will be the consumer’s responsibility to return the product to the original place of purchase.

Elementi will not be responsible for consequential damages in excess of the purchase price of the product on which such liability is based and the warranty does not cover costs including freight, removal and reinstallation.

This warranty is non-transferable and applies only for units that are for non- commercial personal use only.

Under this warranty agreement, all gas lines must be installed by a licensed gas fitter.
Damage caused by shipping, staining and abuse are not covered under this warranty. Dings, dents and scratches, fading and natural weathering are not covered under this warranty.
Decorative rock is not covered under this warranty. Improper installations, repair or modifications made by anyone other than Elementi will void this warranty and any damage caused by such is also not covered under this warranty.

Minor chipping, weather fading, water staining and non-structural hairline cracks are typical of the material of this product and are not covered under this warranty. Some color and texture variation is typical of the material and finish for this product and is not covered under this warranty.

Cast concrete is a hand finished process. As such, this product’s finish will vary by unit. There will be a color variance of up to 15% in each unit. There may also be uneven texture or pattern as well as small holes in the surface caused by air or water trapped on the surface during casting. This is a normal trait of cast concrete and is not covered under warranty.

Ocean Rock USA LLC
1300 W. 9th St., Upland, CA 91786
www.elementifire.com
info@elementifire.com
Tel: 800-678-7294

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>