20 Pressure and Vacuum Murphygage and Swichgage Instruction Manual
- June 13, 2024
- MURPHY
Table of Contents
- Installation Instructions
- Description
- Alarm Before Shutdown Models
- Typical Mounting Dimensions
- Panel Mounting
- Check List
- Pressure Port Connection
- Vacuum Models Connection
- Differential Pressure Models Connection
- Pressure Ranges and Factory Settings
- Setting the Swichgage Instrument Contacts
- Testing the Contacts
- Installing the Magnetic Switch
- Wiring
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
20 Pressure and Vacuum Murphygage and Swichgage Instruction Manual
Installation Instructions
Pressure and Vacuum Dial Murphygage® and Swichgage® Instruments 20, 25, A20 and A25 Series, 2 and 2-1/2 in. (51 and 64 mm) Dial Sizes
WARNING Before beginning installation of this Murphy product:
- Disconnect all electrical power to the machine
- Make sure the machine cannot operate during installation
- Follow all safety warnings of machine manufacture
Please read the following instructions and visually inspect product for shipping damage before installation.
Description
The 2 and 2-1/2 in. (51 and 64 mm) dial size Murphygage and Swichgage instruments are diaphragm-actuated, pressure or vacuum gages with a 1/8-27 NPTM pressure port connection (2 pressure ports for differential pressure models).
Models with face-adjustable contact(s) are rated for 2 A @ 30 V (pilot duty). If the gage case is steel (20P, 25P, 20DP, 25DP etc.), the ground path for the contact circuit is through the case. Therefore, the case must be installed in the ground plane of the electrical power supply.
If the case is polycarbonate (A20P, A20DP, A25P, A25DP etc.), the ground path is isolated and is made through the C or P terminals on the back of the gage case (C for A20 models; P for A25 models).
Models 20PE, 25PE, A20PE, A25PE etc. have a snap-acting switch instead of the face adjustable pointer type contact. Electrical rating is 3 A @ 30 VDC, 4 A @ 125 VAC. Reset differential for the switch is approximately 10% of the scale.
NOTE : Select a scale so your normal operating pressure is in the upper middle of the scale.
WARNING Certain dangers to human safety and to equipment may occur if some equipment is stopped without pre-warning. It is recommended that monitored functions be limited to alarm only or to alarm before shutdown.
Alarm Before Shutdown Models
The models 20PABS, A20PABS, 25PABS and A25PABS feature a front limit contact for equipment shutdown and an internal SPDT snap-switch for Alarm Before Shutdown. When the low side (preset point) of the snap-switch trips, the N.C. terminal completes a circuit to activate an alarm. A continued decrease in pressure will complete the shut-down circuit. An increase in pressure of approximately 10% of scale is necessary before the snap-switch (alarm) will reset and open the circuit.
Typical Tattletale® Magnetic Switch
Murphy by Enovation Controls manufactures several patented Magnetic Switches for protection of the pilot-duty Swichgage contacts and to ensure positive shutdown of equipment. There are magnetic switches for CD ignition, Magneto, Battery systems and electric motor-driven equipment. Tattletale annunciators show the cause of shutdown. The first one to trip will lockout all other Tattletale annunciators. Be sure the type of magnetic switch or Tattletale annunciator matches the power source used to trip it.
NOTE: At equipment startup (for models not having a built-in time delay), the reset button must be held in until normal operation occurs or an external time delay may be used. Instructions are packed with each Magnetic Switch or Tattletale annunciator
Products covered by this bulletin comply with EMC Council directive 89/336/ EEC regarding electromagnetic compatibility except as noted.
In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. MURPHY products and the Murphy logo are registered and/or common law trademarks of Enovation Controls, LLC. This document, including textual matter and illustrations, is copyright protected by Enovation Controls, LLC, with all rights reserved. (c) 2016 Enovation Controls, LLC. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/warranty
Typical Mounting Dimensions
NOTE: 20/25 Series: 18 AWG pigtails. A20/A25 series: #4/#6 screws.
| 20 Series| A20 Series| 25 Series| A25 Series
---|---|---|---|---
A| 2-7/32 (56)| 2-9/16 (65)| 2-1/8 (54)| 1-51/64 (46)
B| 1-5/16 (33)| 1-1/4 (32)| 1-3/8 (35)| 1-27/64 (36)
C| 2-15/64 (57)| 2-1/4 (57)| 3-1/8 (79)| 2-29/32 (74)
D| 2-1/16 (53)| 2-1/16 (53)| 2-11/16 (68)| 2-11/16 (68)
The dimensions are in inches and (millimeters).
Panel Mounting
IMPORTANT: Mount the magnetic switches and valves upright to prevent
moisture collection
All models can be installed in a panel from 0.032 to 0.250 in. (1 to 6 mm) thick.
- Remove the mounting clamp and fasteners.
- Insert the gage from the front side of the panel.
- Reinstall the mounting clamp and fasteners. Do NOT overtighten
Check List
When properly used, the Swichgage instruments, magnetic switches and shut-down or alarm devices are effective tools in any preventive maintenance program. For optimum performance, check these tools periodically:
- Look for frozen pointers, kinked/worn tubing, broken wiring or loose connections.
- Operate the contacts and watch for expected results.
- Replace damaged/worn parts; clean/repair as necessary. Check for correct/complete wiring, unbroken insulation and no accidental grounds.
- Do not run shut-down wires with ignition wiring.
- Check all tubing and connections for leaks.
Pressure Port Connection
Pressure tubing is generally not provided. The use of good, quality flexible pressure tubing/hose and fittings are strongly suggested.
CAUTION: DO NOT FOUL the pressure orifices with pipe dope or dirt or the
SWICHGAGE® instrument will not operate.
Use at least 3/16 in. (5 mm) I.D. tubing. If using copper or rigid tubing, install at least 12 in. (305 mm) flexible hose from the gage to the rigid tubing. This prevents damaging vibration from reaching the gage.
For most models a pulsation orifice, within the pressure port, is provided, and it is removable for cleaning.
- Apply sealant on the male threads being careful not to contact the pressure orifice
Description| Sealant Specification
---|---
Pressure Port Threads| Teflon Base Pipe Dope or Teflon Tape - Connect the tubing to the 1/8-27 NPTM port and tighten.
Vacuum Models Connection
The vacuum instruments measure intake manifold vacuum and give an indication of the load applied to the engine.
CAUTION: DO NOT FOUL the pressure orifices with pipe dope or dirt or the
SWICHGAGE® instrument will not operate.
Mount the gage in a suitable location so that the face is visible and easily accessible. Connect suitable tubing to the 1/8-27 NPT port of the gage and to an open port in the intake manifold. Mounting kit V5179 is suggested and includes tubing and necessary fittings.
The manifold fitting is 1/4 NPT. The drawing to the right shows a typical mounting using V5179 kit. A Murphy PD2160 is also recommended.
- Apply sealant on the male threads being careful not to contact the pressure orifice.
Description| Sealant Specification
---|---
Port Threads| Teflon Base Pipe Dope or Teflon Tape - Connect the tubing to the 1/8-27 NPTM port.
- Be sure connections are tight—gage will not operate properly if line leaks.
Differential Pressure Models Connection
Differential pressure models are typically applied to indicate restriction in oil/fuel filters. The High pressure port (center mounted) is piped to the Inlet side of the filter. The Low pressure port (top center mounted) is piped to the Outlet side of the filter.
CAUTION: Failure to use a second wrench on the low pressure port when
tightening tube fittings may result in damage to the internal mechanisms.
CAUTION: DO NOT FOUL the pressure orifices with pipe dope or dirt or the
SWICHGAGE® instrument will not operate.
To connect the high pressure tubing use at least 3/16 in. (5 mm) I.D. flexible pressure tubing/ hose and fittings. If using copper or rigid tubing, install at least 12 in. (305 mm) flexible hose from the gage to the rigid tubing (to prevent damaging vibration to the gage).
- Apply sealant on the male threads being careful not to contact the pressure orifice
Description| Sealant Specification
---|---
High and Low Pressure Port Threads| Teflon Base Pipe Dope or Teflon Tape - Connect the tubing to the Low Pressure 1/8-27 NPTM port.
- You MUST use a wrench to hold the low pressure port in position while using a second wrench to tighten the pressure tubing/hose fitting onto the port. Doing so will prevent damage to the internal mechanisms of the gage.
- Connect the tubing to the High Pressure 1/8-27 NPTM port and tighten
IMPORTANT: NEVER exceed maximum static pressure or differential pressure
ratings for your gage range; listed below.
Ranges Available| Max. Static Pressure| Max. Differential
Pressure| Contact Setting
---|---|---|---
0-15 (0-103) [0-1.0]| 50 (345) [3.4]| 30 (207) [2.0]| 10 (69) [0.8]
0-30 (0-207) [0-2.0]| 150 (1.0) [10]| 60 (414) [4.0]| 20 (138) [1.0]
0-50 (0-345) [0-3.5]| 300 (2.1) [20]| 100 (690) [7.0]| 30 (207) [2.0]
0-75 (0-517) [0-5.0]| 300 (2.1) [20]| 150 (1.0) [10]| 50 (345) [3.5]
0-100 (0-690) [0-7.0]| 300 (2.1) [20]| 200 (1.4) [14]| 60 (414) [4.0]
Values are shown in psi, (kPa/MPa) and [bar]. Values in kPa/MPa and bar are
mathematical conversions from psi–they do not reflect actual second scale
range.
Pressure Ranges and Factory Settings
Ranges Available| Maximum| Std. Settings*| __Hi
Settings**| 20/25PABS Settings| Start-up Lockout Settings
---|---|---|---|---|---
Low| Alarm +| Contact| Lockout| Release (max.)
psi| bar| pressure| psi| bar| psi| bar| psi| bar| psi| bar| psi| bar| psi|
bar| psi| bar
0-15 (103)| 1.0| 30 psi (21 MPa)| 3 (21)| 0.2| 12 (83)| 0.8| 3 (21)| 0.2| 6
(41)| 0.3| 3 (21)| 0.2| 4 (28)| 0.3| 6 (41)| 0.4
0-30 (207)| 2.0| 60 psi (21 MPa)| 7 (48)| 0.4| 24 (165)| 1.6| 7 (48)| 0.4| 10
(69)| 0.6| 4 (28)| 0.4| 7 (48)| 0.5| 10 (69)| 0.7
0-50 (345)| 3.5| 100 psi (21 MPa)| 10 (69)| 0.8| 40 (276)| 2.8| 10 (69)| 0.8|
13 (90)| 1.0| 10 (69)| 0.5| 13 (90)| 1.0| 20 (138)| 1.4
0-75 (517)| 5.0| 150 psi (21 MPa)| 15 (103)| 1.0| 60 (414)| 4.0| 15 (103)|
1.0| 18 (124)| 1.5| 10 (69)| 0.7| 15 (103)| 1.0| 23 (159)| 1.6
0-100 (690)| 7.0| 200 psi (21 MPa)| 20 (138)| 1.5| 80 (552)| 5.5| 20 (138)|
1.0| 23 (159)| 1.5| 20 (138)| 1.0| 25 (173)| 2.0| 35 (241)| 2.4
0-150 (1.0 MPa)| 10| 300 psi (3.4 MPa)| 30 (207)| 2.0| 120 (827)| 8.0| 30
(207)| 1.5| 33 (228)| 2.0| 20 (138)| 1.5| 30 (207)| 2.0| 45 (310)| 3.1
0-200 (1.4 MPa)| 14| 400 psi (3.4 MPa)| 50 (345)| 3.0| 150 (1 MPa)| 10| 50
(345)| 3.0| 53 (365)| 4.0| 40 (276)| 3.0| 50 (345)| 3.5| 70 (482)| 4.8
0-300 (2.1 MPa)| 20| 500 psi (3.4 MPa)| 75 (517)| 5.0| 225 (1.6MPa)| 15| 75
(517)| 5.0| 78 (538)| 5.0| 50 (345)| 3.5| 75 (517)| 5.0| 105 (724)| 7.2
0-400 (2.8 MPa)| 28| 500 psi (3.4 MPa)| 150 (1MPa)| 7.0| 300 (2.1MPa)| 20| 75
(517)| 5.0| 150 (1MPa)| 10| 100 (690)| 6.0| —| 7.0| 150 (1MPa)| 10
Values listed between ( ) are mathematical conversions from psi to
kPa/MPa–they do not reflect second scale range. U.S.A. standard scale is
psi/kPa; U.K. standard scale is psi/bar. Consult factory for other scales.
* Standard setting for 20P/25P and 20PE/25PE models
** Low settings for Hi/Lo option same as a standard settings. Hi/Lo
option available for 20P/25P models only.
+ SPDT Snap-switch is the alarm switch.
Setting the Swichgage Instrument Contacts
Some models such as A20PE, A25PE, etc. may not have field adjustment. Consult the factory if in doubt.
IMPORTANT: If the Swichgage has a lockout push button on the face, a contact
setting higher than the factory setting will make the lockout device
inoperative.
For 20PE, 25PE, 25DPE, A20PE, A25PE and A25DPE models, the switch trip point CANNOT be set at either the lowest or the highest extremes of the scale. Trip point MUST allow for the switch reset differential. For adjustable switch versions, the switch point is adjustable ONLY over the lower half of the scale.
For adjustable models:
- Use a 1/16 in. hex wrench to set contacts. A 1/4 turn clockwise lowers switch operating point approximately 7% of scale.
- Observe the normal operating pressure or vacuum readings.
- Set the contact slightly below minimum reading observed or slightly above minimum pressure recommended by equipment manufacturer. For differential pressure models, set the contact slightly below the desired maximum differential pressure.
Testing the Contacts
- With equipment running, use a 1/16 in. hex wrench to rotate the contact until it touches the pointer. Do NOT force contact against the gage pointer. Equipment should shut down and/or alarm should operate. Reset the contact.
- VERY IMPORTANT: Each time you start the machine, observe that the SWICHGAGE® is indicating pressure or vacuum.
- Perform a visual inspection and regular testing as a normal procedure to ensure proper operation and to achieve maximum results from your Swichgage instrument.
Installing the Magnetic Switch
WARNING: Disconnect the battery or power source before beginning the installation. See specific wiring instructions packed with each magnetic switch or tattletale annunciator.
- Mount with electrical lugs down. Drill mounting holes in panel.
- Clean away burrs and filings. Position the magnetic switch in the panel, making sure the pilot stud is in place.
- Add decal, then washer, then nut and tighten.
NOTE : Murphy components are easily wired and maintained. Use good
quality wire and terminals. The type of magnetic switch differs for various
applications. See typical wirings below. Wiring and instructions are packed
with each magnetic switch.
Wiring
WARNING: Disconnect the battery or power source before beginning the installation. For battery ignition systems, disconnect the battery ground strap. Face adjusted pointer type contacts are pilot duty. Do not exceed contact ratings on any swichgage® model.
20 and 25 Series models wire leads are 18 AWG or 20 AWG, 12 in. (305 mm) long. A20 and A25 Series models have number 4 or number 6 screw terminals. When installing the Swichgage instrument on an ungrounded panel, you MUST provide a ground wire from the Swichgage instrument to a common ground. Install ONLY in a 12 or 24 V system. Warning lights or audible signal must be of the same voltage as the battery. Current draw should never exceed Swichgage contact rating
CAUTION: Ordinary incandescent lights are damaging to Swichgage contacts. We
recommend using our direct connected alarms TL-7 flashing lamp and/or SAH
mini-siren.
The pictorial below shows typical wirings for each base model. Look for specific typical wiring diagram with your base model number and wire accordingly. The pointer is shown in the Shelf Position. Face adjusted pointer type contacts are rated pilot duty 2 A @ 30 VAC/DC. Snap-switch contacts are rated 3 A @ 30 VDC; 4 A @ 125 VAC
CAUTION: On some models pointer contact and ABS switch share the same
Common. Voltage source must be the same. Maximum voltage is 30 V. Consult
factory for applications with 120 VAC systems
Troubleshooting
DO THIS FIRST:
- Look for broken wiring, frozen pointer, dirty contacts (will not make), burnt pointer or contact.
- Verify that all wiring is intact and connections are tight.
- Verify that Swichgage has not been damaged (hit or dropped).
- Verify that there is pressure/vacuum supplied to the gage.
- Verify that the Swichgage is operative (it reads).
- Verify that the alarm or shut-down device is fully operable, and check components such as spark plugs, ignition, fuel pump and filter, etc.
- Reset magnetic switch and verify that it stays latched.
SYMPTOM | CAUSE | TEST/REMEDY |
---|---|---|
Engine will not start |
- Short or open circuit, be sure the magnetic switch latches and puts out power to the run device or removes ground (ignition). Check for power/ ground at run device
- Control circuit overloaded by accessories (blown fuse in magnetic switch)
- False ground in control circuit
|
- Reset magnetic switch and make sure it stays latched. Refer to installation instructions for 518PH magnetic switch (provided with unit).
- Find blown fuse and replace (use 14 A fuse). Reroute the accessories.
- Repair.
False shutdown|
- Swichgage circuit has intermittent open or short
- Vibration causes the Magnetic Switch to trip
|
- Check all wiring and repair/replace as necessary.
- Repair and relocate the switch as needed.
Swichgage closes but does not trip the magnet- ic switch or kill the engine|
- Incomplete shutdown circuit
- Dirty Swichgage contacts
- Ignition not providing power to primary terminal post
- Swichgage case may not be grounded
- Incorrect magnetic switch for type of power
|
- Locate open circuit and repair.
- Clean and check that contacts make.
- Repair ignition.
- Ground case.
- Replace with correct magnetic switch.
Magnetic switch tripped but engine is still running|
- Open circuit between the magnetic switch and the shutdown device
- Lost ground to kill the engine
|
- Check wiring from magnetic switch to shut-down device, repair or replace.
- Check all wiring and connections and repair.
Pointer will not operate properly, inaccurate reading|
- Frozen pointer
- Loose pointer spring (caused by hitting or dropping gage)
- Plugged pressure orifice
- Over Pressure
|
- Return for repair or replacement.
- Return for repair or replacement.
- Remove and clean.
- Return for repair or replacement.
Pointer/contact burned-in two| Without exception this condition is caused by incorrect wiring or short circuit| Recheck wiring; replace Swichgage or return for repair.
ENOVATION CONTROL CORPORATE HEADQUARTERS
5311 S 122ND EAST AVENUE
TULSA, OK 74146
918-317-4100
FOR MORE INFORMATION:
www.fwmurphy.com
References
- FW Murphy Production Controls
- Warranty & Terms of Sale - FW Murphy Production ControlsFW Murphy Production Controls
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>