PRODUCT

Product Information

The product is a transmitter that must not be used in conjunction with any other antenna or transmitter. It is designed to comply with RF radiation exposure limits for an uncontrolled environment. The equipment should be installed and operated with a minimum distance of 20cm between the radiator and the user’s body.

Product Usage Instructions

Follow these instructions to ensure safe and proper usage of the transmitter:

  1. Do not use the transmitter in conjunction with any other antenna or transmitter.
  2. Make sure to install and operate the equipment in an environment with a minimum distance of 20cm between the radiator and your body.
  3. Keep the transmitter away from your body while operating it.
  4. Do not place any objects or materials between the transmitter and your body.
  5. Ensure that the transmitter is properly installed according to the manufacturer’s instructions.
  6. Follow any additional safety guidelines provided by the manufacturer.

By following these guidelines, you can minimize RF radiation exposure and ensure safe usage of the transmitter.

PACKAGE CONTENTS

SENSOR

VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-
FIG-1

RECEIVER

VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-
FIG-2

4 AA BATTERIES

2 A BATTERIES REQUIRED FOR EACH SENSOR AND RECEIVER

STRING

VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-
FIG-3

BUTTON INSTRUCTION AND AUTOMATICALLY CONNECTING

  1. Press both briefly to turn on, and press and hold to turn off.
  2. Quickly press the sensor twice to switch the temperature unit to °C/°F.
    The receiver will automatically switch accordingly.

MEASUREMENT SPECIFICATIONS

  1. Measuring distance: up to 160 ft when space between is open and uninterrupted.
  2. Temperature range: 23°F – 140°F (-5°C – 60°C) pH levels: 0-14 pH.
  3. Ambient temperature range for usage: -5°C – 60 °C (23°F – 140°F).
    Do not use when the outdoor environment is frozen to avoid damaging the sensor.

OPERATING INSTRUCTIONS

BATTERY INSTALLATION

Remove the battery cover on the back of the sensor and receiver.

VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-
FIG-5

  1. 2 Insert 2 AA 1.5V batteries(batteries included) as indicated by the polarity symbols (+/-) in the receiver first and replace the battery cover.
    Within 3 minutes, insert 2 AA 1.5 batteries in the Sensor. Both of them will power on automatically.

  2. At this point, the sensor’s signal icon will move outward.

  3. The receiver will power on and connect with the sensor Its icon
    will blink three times, which indicates a successful connection. The screen will display the data from the sensor synchronously.

  4. After completing the mentioned steps, securely attach the button to the pool ladder before proceeding with the test.VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-FIG-8

AUTOMATIC CONNECTING FAILURE

When automatic connecting fails, the receiver will not display any values and show as follows.

Please follow the steps below to reconnect.

  • Method 1: Press the button to restart the receiver. It will automatically connect within 3 minutes. If unsuccessful, try Method 2 for manual reset.
  • Method 2: Press the button to turn off the receiver, and remove the batteries. While holding down the button reinsert the batteries.
  • The screen will display three dashes, as shown below:VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-FIG-11
    Meanwhile, the signal icon will blink from outside to inside, indicating that it is receiving the signal and will last for 3 minutes. If connecting is successful within 3 minutes, the screen will display the following content:

Then the receiver will automatically restart. If the receiver synchronously displays the values from the sensor within 3 minutes of automatic startup, it indicates a successful connection.

LOW BATTERY WARNING

VELONG ENTERPRISES-MS200117 2-In 1 Wireless Thermometer and PH Reader-
FIG-14

It is imperative to promptly replace the batteries to maintain the product’s measurement accuracy and prevent damage.

FCC CAUTION

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful

Note: This equipment has been tested and found to comply with the limits for a Class B digital device. Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC RF Radiation Exposure Statement:

  1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
  2. This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.
    This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals