Autonics CX6S-2P LCD Display Counter Timer Instruction Manual
- June 13, 2024
- Autonics
Table of Contents
- Autonics CX6S-2P LCD Display Counter Timer
- Safety Considerations
- Ordering Information
- Unit Des ription
- Specifications
- Dimensions
- Connections
- Operations
- Counter Mode
- Timer Mode
- Factory Default
- Error Display and Output Operation
- Cautions during Use
- Major Products
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Autonics CX6S-2P LCD Display Counter Timer
Thank you for choosing our Autonics product.
- Please read the following safety considerations before use.
Safety Considerations
- Please observe all safety considerations for safe and proper product operation to avoid hazards.
- symbol represents caution due to special circumstances in which hazards may occur.
- Warning Failure to follow these instructions may result in serious injury or death.
- Caution Failure to follow these instructions may result in personal injury or product damage.
Warning
- A fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss.
- Install on a device panel to use. Failure to follow this instruction may result in electric shock or fire.
- Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in electric shock or fire.
- Check ‘Connections’ before wiring. Failure to follow this instruction may result in fire.
- Do not disassemble or modify the unit. Failure to follow this instruction may result in electric shock or fire.
Caution
- When connecting the power input and relay output, use AWG 20 (0.50mm2) cable or over, and tighten the terminal screw with a tightening torque of 0.74 to 0.90N.m. Failure to follow this instruction may result in fire or malfunction due to contact failure.
- Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage.
- Use the unit within the rated specifications. Failure to follow this instruction may result in shortening the life cycle of the unit, or fire.
- Do not use the unit in a place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion.
- Keep metal chips, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire or product damage.
Manual
For detailed information and instructions, please refer to the user manual
and be sure to follow cautions. Visit our homepage
(www.autonics.com) to download manuals.
Ordering Information
Unit Des ription
CX6S Series
CX6M Series
- Counting value display component (red)
- RUN mode : Displays counting value for counter operation or time progress value for timer operation. Function setting mode: Displays parameter.
- Setting value display component (green)
- RUN mode: Displays setting value.
- Function setting mode: Displays parameter setting value.
- Time unit indicator (h:m:s): Turns ON for time unit for timer.
- Key lock indicator ( ): Turns ON for key lock setting.
- Reset input indicator (RST): Turns ON for reset key input or reset signal input.
- INH indicator (INH)
- For the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 – ), it turns ON for INHIBIT signal input. (In case of CX6S Series and timer mode, it turns ON for INB/INH signal input.) For free voltage input model (CX6 – F), it turns ON for INB/INH signal input for timer.
- Output indicator (OUT1, OUT2): Turns ON for the dedicated control output ON.
- SV checking and changing indicator (SET, SET1, SET2) (green)
- Turns ON when checking and changing SV.
- COUNTER indicator (COUNTER): Turns ON for counter operation.
- TOTAL indicator※1 (TOTAL)
- In the case of TOTAL counter display mode, it turns ON with the COUNTER indicator.
- TIMER indicator (TIMER) : Flashes (progressing time) or Turns ON (stopping time) for timer operation.
- RESET key RUN mode, Function setting mode: Press the RESET key to reset the counting value and turn OFF the output. TOTAL counter display mode※1: Press the RESET key to reset the counting value of the TOTAL counter.
- MODE KEY RUN mode: Hold the MODE key over 3 sec to enter function setting mode. Press the MODE key to select SV2 (SET2)/SV1 (SET1)/TOTAL counter※1 display for counter operation.
- Function setting mode: Hold the MODE key for over 3 sec to return to RUN mode. Press the MODE key to save the SV and enter the next setting.
- Function setting check mode: Hold the key for over 1 sec to return to RUN mode. Changing SV mode: Press the key to save SV and return to RUN mode.
- , key
- key RUN mode: Press the key to change SV and move SV (SET, SET1, SET2) digits. Changing SV mode: Press the key to change digits.
- key Changing SV mode: Increases SV. Function setting mode: Changes the settings.
- This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 – ).
Specifications
- This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 – ).
- The weight includes packaging. The weight in parenthesis is for units only.
- Environment resistance is rated at no freezing or condensation.
- The above specifications are subject to change and some models may be discontinued without notice.
- Be sure to follow the cautions written in the instruction manual, user manual, and technical descriptions (catalog, homepage).
Dimensions
Panel cut-out
Bracket
Terminal cover (sold separately)
Connections
CX6S Series
- Voltage input (PNP)/no-voltage input (NPN) selectable model
Free voltage input model
CX6M Series
- Voltage input (PNP)/no-voltage input (NPN) selectable model
Free voltage input model
- AC voltage: 100-240VAC 50/60Hz AC/DC voltage: 24VAC 50/60Hz, 24-48VDC
Operations
Operation and setting (counter/timer)
Function setting mode
Hold the MODE key over 3 sec to enter function setting mode in RUN mode.
Set the function by the MODE , keys. Hold the key over 3 sec to return to
RUN mode in function setting mode.
Function setting check mode
Hold the key over 1 sec to enter function setting check mode in RUN mode. When
checking the saved parameters, press the MODE , key to check the next
item.. Hold the key over 1 sec at function setting check mode and it returns
to RUN mode.
RESET
In RUN mode, function setting mode, press the RESET key to reset the
current value and the output turns OFF. At TOTAL counter display mode※1, press
the RESET key to reset the TOTAL counter counting value and the current
counting value.
- This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 – ). The TOTAL counter display mode is only for counter operation.
Function setting
Counter Mode
Parameter setting
- MODE key: Moves parameters, key: Changes parameter setting value)
- For voltage input (PNP), no-voltage input (NPN) model (CX6 – ).
- For the free voltage input model(CX6 – F), these parameters do not appear due to fixed settings.
- For the 1-stage setting model (CX6 -1P ), OUT1 does not appear. The OUT2 output time is displayed as OUtT.
- Decimal point and prescale decimal point
- Decimal point: Set the decimal point for display value regardless of prescale value.
- Prescale decimal point
- Set the decimal point for the prescale value of the counting value regardless of the display value.
Input mode
- This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 – ).
- A: over min. signal width, B: over than 1/2 of min. signal width. If the signal is smaller than this width, it may cause a counting error (±1).
Prescale function
This function is to set and display calculated unit for actual length,
liquid, position, etc. It is called the “prescale value” for measured length,
liquid, position, etc. per 1 pulse. For example, when moving L, the desired
length to be measured, and P, the number of pulses per 1 revolution of a
rotary encoder, occurs, the prescale value is L/P.
- Positioning control by counter and encoder
[ Diameter (D) of pulley connected with encoder=22mm, the number of pulses by 1 rotation of encoder=1,000]
- Prescale value
Set decimal point [ ] as [—–.-], prescale decimal point [ ] as [—.—], and prescale value [SCL] as [ ] at function setting mode. It is available to control conveyor position by 0.1mm unit.
Timer Mode
Parameter setting
- ( MODE key: Moves parameters, key: Changes parameter setting value)
- Timer output mode for ‘0’ time setting[ ]
- Operations by output mode (‘0’ time setting)
OND (Signal ON Delay) mode [ ]
- Set ‘0’ for setting time 1.
- Set ‘0’ for setting time 2.
OND.1 (Signal ON Delay 1) mode [ 1]
- Set ‘0’ for setting time 1.
- Set ‘0’ for setting time 2.
OND.2 (Power ON Delay) mode [ 2]
- Set ‘0’ for setting time 1.
- Set ‘0’ for setting time 2.
OND.3 (Power ON Delay) mode [ 3]
- Set ‘0’ for setting time 1.
- Set ‘0’ for setting time 2.
NFD (ON-OFF Delay) mode [NFD]
- Set ‘0’ for Off_Delay setting time.
- Set ‘0’ for On_Delay setting time.
NFD.1 (ON-OFF Delay1) mode [nFd1]
- Set ‘0’ for Off_Delay setting time.
- Set ‘0’ for On_Delay setting time.
Factory Default
- For the 1-stage setting model (CX6 -1P ), does not appear. The output time of is displayed as .
- This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 – ).
Error Display and Output Operation
- Error Display3
-
- Error description
- Setting value is 0.
-
- Troubleshooting
- Change the setting value anything but 0.
- When error occurs, the output turns OFF.
- When 1st setting value is set as 0 (zero), OUT1 maintains OFF. When 2nd setting value is smaller than 1st setting value, 1st setting value is ignored and only OUT2 output operates.
- Indicator model does not have error display function.
Cautions during Use
- Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
- In case of 24-48VDC, 24VAC model, power supply should be insulated and limited voltage/ current or Class 2, SELV power supply device.
- Use the product, 0.1 sec after supplying power.
- When supplying or turning off the power, use a switch or etc. to avoid chattering.
- Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
- Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.
- This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000m
- Pollution degree 2
- Installation category II
Major Products
- Photoelectric Sensors
- Fiber Optic Sensors
- Door Sensors
- Door Side Sensors
- Area Sensors
- Proximity Sensors
- Pressure Sensors
- Rotary Encoders
- Connector/Sockets
- Switching Mode Power Supplies
- Control Switches/Lamps/Buzzers
- I/O Terminal Blocks & Cables
- Stepper Motors/Drivers/Motion Controllers
- Graphic/Logic Panels
- Field Network Devices
- Laser Marking System (Fiber, Co₂, Nd: YAG)
- Laser Welding/Cutting System
- Temperature Controllers
- Temperature/Humidity Transducers
- SSR/Power Controllers
- Counters
- Timers
- Panel Meters
- Tachometer/Pulse (Rate) Meters
- Display Units
- Sensor Controllers
HEADQUARTERS:
18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan, South Korea, 48002
- TEL: 82-51-519-3232
- E-mail: sales@autonics.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>