solar edge SE-MTR240-NN-S-S1 Energy Meter with Modbus Connection Owner’s Manual

June 13, 2024
Solar edge

solar edge SE-MTR240-NN-S-S1 Energy Meter with Modbus Connection

Product Information

The Energy Meter with Modbus Connection is designed for residential installations in North America. It features a Type NEMA 3R enclosure for outdoor protection and provides high accuracy meter readings. The meter communicates over RS485 to provide monitoring data and is suitable for export limitation, consumption monitoring, and StorEdgeTM applications. The product is backed by a 5-year warranty.

Product Usage Instructions

  1. Ensure that the Energy Meter is properly installed in a suitable location with the provided NEMA Type 3R enclosure for outdoor protection.
  2. Connect the Energy Meter to the supported inverter’s electrical service by following the provided electrical specifications for AC input voltage, frequency, and max input current.
  3. If using current transformers (CTs), order them separately and ensure they are correctly connected to the Energy Meter’s L1 and L2 terminals.
  4. If necessary, connect the Energy Meter to the monitoring system or data logger using the RS485 communication interface.
  5.  Ensure that the Energy Meter is powered and properly configuredfor export limitation, consumption monitoring, or StorEdgeTM applications as required.
  6. Refer to the product manual for further instructions on configuring and utilizing the Energy Meter’s features.

FEATURE

  • Simple installations and connectivity
  • Type NEMA 3R enclosure for outdoor protection
  • Provides high accuracy meter readings
  • Communicates over RS485 to provide monitoring data
  • Suitable for export limitation, consumption monitoring and StorEdgeTM applications

SPECIFICATION

SUPPORTED INVERTERS SINGLE PHASE INVERTERS UNITS

ELECTRICAL SERVICE
AC Input Voltage (Nominal)| 240| Vac
AC Frequency (Nominal)| 60| Hz
Max AC Input Current| 100| mA
Connector Type| Terminal block – 22 to 12| AWG
Grids supported| L1 / L2 / N / PE L1 / L2 / PE|
Power Consumption (Nominal)| 3| W
METER ACCURACY (@ 77°F / 25°C, PF:0.7- 1)
1 – 100% of Rated Current CT| ±1.0| %
CURRENT TRANSFORMERS ( 1 )
Nominal Input (at CT Rated Current)| CT1, CT2: 0.333| Vac RMS
Rated RMS current(2)| 200| 400| A
Dimensions (Internal / External)| 0.8 x 0.8; 2.4 x 2.4 / 20 x 20; 61 x 61| 1.26 x 1.83; 3.3 x 4.5 / 32 x 46.5; 83.4 x 114| in/mm
STANDARD COMPLIANCE
Safety| UL 1741:2010 Ed.2(Supplement SA)+R: 07 Sep 2016|
Emmissions| FCC 47 CFR Part 15 Subpart B|
ENVIRONMENTAL
Operating Temperatures| -40 to +140 / -40 to +60| °F / °C
Relative Humidity (noncondensing)| 5-90| %
Enclosure type| High impact, ABS and/or ABS/PC plastic UL 94V-0, IEC FV-0|
Protection Rating| NEMA Type 3R|
INSTALLATION SPECIFICATIONS
Dimensions (HxWxD)| 8.1 x 12.4 x 4.6 / 206.6 x 316 x 117.5| in / mm
Weight| 3.9 / 1.8| lb / kg
Conduit Entry Diameters| 0.75 or 1 / 19 or 25| in
Mounting Type| Bracket mount|

DIMENSION

Current Transformer Dimensions

solar-edge-SE-MTR240-NN-S-S1-Energy-Meter-with-Modbus-
Connection-1

Connecting the Energy Meter

solar-edge-SE-MTR240-NN-S-S1-Energy-Meter-with-Modbus-
Connection-2

  • Current Transformers (CTs) should be ordered separately: SEACT0750-200NA-20 (200A); SEACT1250-400NA-20 (400A). Each comes in boxes of 20.

BayWar.e. Solar Systems Inc.
4703-101 Street NW, T6E 5C6
Edmonton, AB
Tel: +1 844 851 2390
solardistribution@baywa-re.ca

©SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 02/2019/V01/ENG NAM. Subject to change without notice.
solaredge.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals