SPECIFICATIONS

Vacuum Part

  • Item: Standard
  • Rated V Voltage/Frequency: 120 V, 60 Hz
  • Rated Power (W): 1000 W + 10%
  • Noise Level (SPL dB): < 82 dB
  • Machine Suction HS (KPa): > 18
  • Induction Distance max. : 3”- 4”
  • Standby Power (W): P < 1.5
  • Power Adapter Input: 100–240V~ 50/60Hz, 0.4A
  • Certificate: UL & CL
  • Canister volume: 3.8 Liters
  • Rated Parameter: 120V 60 Hz

Operating Conditions

  • Temperature: -10°–40°C / 14°–104°F
  • Humidity: ≤ 85% RH

Air Purifier Part

  • Item: Standard
  • Rated Parameter: 28 W
  • CADR (Particle): > 60 m3/h
  • Rated Parameter: 28 W
  • Rating Power: 28.7 W (+2.87 W)
  • Noise: < 52 dB
  • Speed: 2400 RPM (+150 RPM)
  • Dimensions: 14.17” x 8.6” x 20.12”

IMPORTANT SAFETY INSTRUCTIONS

This electrical appliance must always be used according to the following safety instructions. Save these instructions as this manual contains important safety and operating information. When using an electrical appliance, basic precaution should always be followed, including the following:

READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THIS APPLIANCE:
To reduce the risk of fire, electric shock or injury

  1. Always press both the vacuum Power button and the air purifier Power button to the off position before unplugging EyeVac Air.

  2. Always unplug the appliance before cleaning or servicing it. Do not unplug by pulling the cord; to unplug, grasp the plug, not the cord.

  3. Do not let the EyeVac Air be used as a toy. Close attention is necessary when used near children. Do not use in Auto mode or leave appliance plugged in near children, infants or small animals.

  4. Do not pull or carry the appliance by the cord. Do not run an appliance over the cord, close a door on the cord, or pull the cord around sharp edges or corners. Keep the cord away from heated surfaces.

  5. Do not use the appliance if the cord or plug is damaged.

  6. Do not handle the plug or appliance with wet hands.

  7. Do not use appliance on wet surfaces.

  8. Do not expose to rain.

  9. Do not use appliance to dispose of water or damp materials such as mud, tile grout, plaster filler, or caulking.
    Do not use to pick up any liquid or wet objects.

  10. Do not use appliance to vacuum up flammable or combustible liquids, such as gasoline. Do not use in areas where these liquids may be present.

  11. Do not use this appliance to vacuum up flammable items such as cigarettes, matches or hot ashes.

  12. Keep hair, loose clothing, and all parts of the body, especially fingers, away from openings and moving parts.

  13. Do not put any objects into appliance openings or use with any openings blocked or plugged.

  14. Do not use this appliance to pick up hard or sharp objects or other large surface litter. Pick these up by hand before vacuuming.

  15. Do not operate without the Canister lid and filters properly in place.

  16. Use the appliance only as described in this User Manual.

  17. Turn appliance off and unplug before removing or replacing the Canister or filters.

  18. Unplug appliance before cleaning or maintenance.

  19. If the appliance is not working as it should, call for instructions for repair. Do not attempt to repair, as it will invalidate your warranty.

  20. When cleaning the outside of the appliance, wipe with a damp cloth to reduce the static electricity on the outer surface.

  21. EyeVac Air is appropriate and warrantied for HOME USE ONLY.

WARNING! To reduce the risk of electric shock do not use on wet surfaces. Do not expose to rain. Store indoors.

DESCRIPTION OF EYEVAC AIR

Save These instructions
For Household Use Only

  1. Control Panel
  2. Inlet
  3. Sensors
  4. Vacuum Power button
  5. Vacuum Manual Activation button
  6. Vacuum Manual mode
  7. Vacuum Auto mode
  8. Canister Full Indicator
  9. Air purifier Power button
  10. Air purifier Activation button
  11. Air purifier Manual mode
  12. Air purifier Auto mode
  13. Filter Indicator
  14. Canister lid
  15. Canister tabs
  16. Canister
  17. Pre-Motor Filter
  18. Air Purification Filters
  19. Activated Carbon Filter
  20. Exhaust Filter Housing compartment
  21. Air Filter Housing (inside lid)
  22. Exhaust Filter
  23. Vent Filter
  24. Serial Number (on back of unit)

ABOUT EYEVAC AIR FILTER

Your EyeVac Air uses a 3-Stage Filtration System to purify your air and eliminate odors.

A. Fine Preliminary Filter (Pre-Filter)

  1. Captures large particles such as dust, lint, fibers, hair, and pet fur.
  2. Maximizes the life of the True HEPA H-13 Filter by protecting it.

B. H-13 True HEPA Filter

  1. Filters at least 99.97% of airborne particles 0.3 micrometers (μm) in diameter.
  2. Filters small particles such as tiny dust particles, parts of smoke and allergens such as pollen and pet dander.

C. Activated Carbon (Charcoal) Filter

  1. Physically absorbs common home impurities like smoke, drying paint, cleaning products and their fumes and traps odors.
  2. Other Volatile Organic Compounds (VOCs) such as benzene, toluene, xylene, and some chlorinated compounds are among those that may be captured by carbon filters.

GETTING STARTED

  1. Remove EyeVac Air from packaging and set upright on any non-carpeted flooring. Remove packing tape from Exhaust Filter on the side of unit.

  2. Plug unit into any standard 120V(US) AC electrical outlet.
    NOTE: EYEVAC AIR CANNOT BE USED WITH A CONVERTER OR ADAPTER

  3. EyeVac Air is appropriate and warrantied for HOME USE ONLY.

OPERATING THE VACUUM: INSTRUCTIONS

NOTE: EyeVac Air cannot operate when the Power and/or Activate button is off.

  1. Open the Canister and ensure that the Pre-Motor Filter is aligned properly (locked into place and flush with the Canister lid). Then, close the Canister.
  2. Plug in your EyeVac Air in the desired location.
  3. Touch Power button to turn EyeVac Air on in Manual mode. Touch Power button again to select Auto mode. A blue LED indicates the unit is on.
  4. Sweep debris over to the EyeVac Air. In Auto mode the sensor detects motion and activates vacuum. When EyeVac is in Manual mode press Activate button to turn on the vacuum.
  5. As debris accumulates, the Canister will need to be emptied. A red LED indicates when it’s time to empty the Canister.

OPERATING THE AIR PURIFIER: INSTRUCTIONS
NOTE: EyeVac Air cannot operate when the Power and/or Activate button is off. EyeVac Air purifies and deodorizes the air for large rooms up to 600 Sq Ft.

  1. Touch Power button to turn EyeVac Air on in Manual mode. Touch Power button again to select Auto mode. A blue LED indicates the unit is on. Long press Power button for 2 seconds to run the air purifier permanently.
  2. Touching the Activate button will run the air purifier for an 8 hour cycle. To adjust Fan speed, touch Activate button to cycle through Fan speed settings (low, medium & high).
  3. When vacuum is activated by debris being swept to the EyeVac Air, air purification will automatically start for a 4 hour cycle.
  4. A red LED indicates when it’s time to change the Air Filters.
  5. Replace Air Filters on both the right and left side of EyeVac Air. See “Replacing the Air Purification Filters” instructions.
  6. Once replaced, long press Activate button for 5 seconds to reset the Air Filter timer and to turn off the Filter Indicator.

AIR PURIFIER FUNCTION DESCRIPTION


Button or Function:

| ****

Operation:

| ****

Detail Description

---|---|---




Power

| ****



Turn on/ Switch to Auto/Turn off

| Power button


a. When the EyeVac Air is in Standby mode, touching the Power button will turn the EyeVac Air on in Manual mode.

b.  When the EyeVac Air is on in Manual mode, touching the Power button will switch the unit to Auto mode.

c.  When the EyeVac Air is on Auto mode, touching the Power button will turn the EyeVac Air off.

d. Long press Power button for 2 seconds to run the air purifier permanently.








Activate

| ****


Manual mode

| When in Manual mode, touching the Activate button will first activate the air purifier for an 8 hour cycle. Touch the Activate button again to:

a. Cycle through Fan speed (L1-L2-L3) .

b. A change in fan speed will be accompanied by the appropriate change in middle LED bar illumination.



Standby Mode

| When in Standby mode, touching the Activate button will turn the unit on in Manual mode (L1).

a. Fan speed is changed by touching Activate button.

b. A change in fan speed will be accompanied by the appropriate change in middle LED bar illumination.





Auto

| ****




Auto Mode

| In Auto mode:


a. When the infrared sensor at the bottom of EyeVac Air detects an object 3-4” in front of it and activates the vacuum, the air purifier will also automatically activate for a 4-hour cycle.

b. When EyeVac Air detects object, the fan automatically goes to L2. The middle LED bar illuminates accordingly.



Filter

| ****


Check/ Reset Filter

| Reset the Air Filter timer when the Filter Indicator LED glows red.


a. Replace the Air Filter. See “Replacing the Air Purification Filters ” instructions on pg. 10.

b.  Activate the air purifier.

c. Long touch air purifier Activate button for 5 seconds to reset the timer to 0.

d.  The Filter Indicator LED will turn off when successfully reset.

VACUUM CLEANER FUNCTION DESCRIPTION


Items:

| ****

Operation:

| ****

Detail Description

---|---|---


Power on/off

| ****

Turn on/off and Auto/Manual

| ****

a. Touch the Power button to turn on EyeVac Air on in Manual mode.

b. When the EyeVac is on in Manual mode, touching the Power button will switch the unit to Auto mode.

c.  When the EyeVac Air is on Auto mode, touching the Power button will turn the EyeVac Air off.



Activate

| ****


Manual mode

| ****

Touch Power button to switch to Manual or Auto mode. If in Manual Mode:

a. Activate button runs vacuum for 8 seconds / 1 cycle.

b.  Touch Activate button as needed until all debris has been removed.





Auto

| ****




Auto Mode

| ****

Touch Power button to switch to Manual or Auto mode. If in Auto mode:

Auto mode, runs for 8 seconds per cycle. When the sensor continuously detects objects, EyeVac Air vacuum will continue running more cycles up to max run time of 48 seconds (6 cycles), then turn off automatically.




Full

| ****



Canister full

| ****

A red LED appears when the Canister is full or the suction inlet is blocked.


a. Be sure to empty the Canister when Full LED is illumniated.

b.  See “Emptying the Canister” instructions on pg. 12.

USER MAINTENANCE INSTRUCTIONS

Replacing the Air Purification Filters

  1. Starting with the Vacuum, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.
  2. Locate the Filter Housing compartment on both the left & right sides of the EyeVac Air.
  3. Press tab down and pull the Air Filter Housing compartment away from the body of the EyeVac Air to locate the Air Filter.
  4. Remove the Air Filter by pulling the tab out. Then, pull the Air Filter straight up and out of the Filter Housing compartment.
  5. Remove Air Filters (2) from the plastic packaging.
  6. Insert Air Filter into the Filter Housing compartment with the front side facing out.
  7. Close the Filter Housing compartment. Repeat steps on opposite side.
  8. Once replaced, long press Activate button for 5 seconds to reset the Air Filter timer and to turn off the Filter Indicator.

USER MAINTENANCE INSTRUCTIONS

Emptying the Canister

  1. Starting with the vacuum side, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.
  2. Pull the Canister outward from the front of the Bin Cavity of the Canister. Grasp the Canister grip firmly and lift it out and away from the body of the EyeVac Air.
  3. Holding the Canister firmly with one hand, grasp the Canister lid handle with the other hand and pull the lid straight up and out to remove.
  4. Turn the Canister upside down over a trash can. Make sure you empty all dirt and debris from inside and below the Bin. To ensure that all the dirt spills out, tap the side of the Canister gently against the edge of the trash can. Re-attach the Canister lid to the top of the Canister.

Cleaning the Canister
The Canister should be washed periodically.

  1. Starting with the vacuum side, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.

  2. Wash the Bin in warm water using a mild soap. Avoid harsh or abrasive cleaners or sponges.
    TO AVOID DAMAGE, DO NOT PLACE CANISTER IN THE DISHWASHER.

  3. Let it air dry. Make sure the Canister is completely dry before putting it back into the EyeVac Air.

  4. Insert the assembled Canister following the instructions outlined in the User Maintenance Instructions

IMPORTANT! Other than cleaning the Pre-Motor Filter and replacing the Exhaust Filter Holder, as described in this User Manual, this EyeVac Air is not user-serviceable. There are no user-serviceable parts inside the unit. Servicing by our Authorized Service Center is required to avoid damage to internal components.

Cleaning The EyeVac Air

  1. Starting with the vacuum side, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.
  2. Clean sensors, inlet area, Canister, Canister lid and Canister Bin Cavity with a damp rag or towel. Do not use soap or alcohol to clean sensors.
  3. After all parts are fully dried, insert the assembled Canister with lid fitting snugly into position and Pre- Motor Filter locked into place and flush with Canister lid. The 2 grooves in the bottom of the bin fit easily over the rod in the front of the unit. Grasp the Canister grip and lock the Canister back into position.

NOTE: Make sure all parts are completely dry before reassembly.
HEALTH TIP: If you suffer from allergies or asthma, take the Canister outdoors to empty. As you empty the dirt into the trash can, gently tap the Canister against the side of the can to remove loose debris.

Taking out the Pre-Motor Filter

  1. Starting with the vacuum side, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.
  2. Pull the Canister outward from the front of the Bin Cavity. Grasp the Canister grip firmly and lift it out and away from the body of EyeVac Air. Locate the Pre-Motor Filter.
  3. Remove the Pre-Motor Filter by grasping the Pre-Motor Filter handle and turn counter-clockwise to the unlock position. Pull Pre-Motor Filter straight up and out of the top of the Canister.

Cleaning the Pre-Motor Filter.
To maintain optimal performance the Pre-Motor Filter will need to be cleaned whenever the suction is not strong. The Pre-Motor Filter must be clean and free of elements, otherwise flow of air may be hindered.

  1. Remove the Pre-Motor Filter and rinse under running water to clean. If needed a mild soap and soft bristled brush can also be used.
    IMPORTANT! DRY THOROUGHLY BEFORE USE.

  2. Slide the Pre-Motor Filter back into the top of the Canister. Rotate clockwise to the “lock” position. Put the Canister back into place.

  3. If a new Pre-Motor Filter is needed, replace with standard filter cartridges. Make sure that it fits snugly in the Filter Holder. Replacement filters are available through EyeVac’s Customer Service Department.

IMPORTANT! NEVER OPERATE THE EYEVAC AIR WITHOUT THE PRE-MOTOR FILTER PROPERLY IN PLACE.

Cleaning the Exhaust Filter

  1. Starting with the vacuum side, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.
  2. The Exhaust Filter Holder slides up and out of its housing on the right and left side of EyeVac Air.
  3. Gently pull the Exhaust Filter out of the Filter Holder.
  4. Tap Exhaust Filter gently against trash container to free and eliminate excess dirt and debris.
  5. To clean the Exhaust Filter, wash in mild soap and water; rinse and dry thoroughly before assembly.
  6. Slide the Filter Holder back into the unit with the Exhaust Filter facing outwards.
    IMPORTANT! NEVER OPERATE EYEVAC AIR WITHOUT THE EXHAUST FILTER AND FILTER HOLDER PROPERLY IN PLACE.

Replacing the Air Filter

  1. EyeVac Air Filter will need to be changed every ~3,000 hours to maintain the highest air quality.
  2. When it is time to change the filter the Filter Indicator LED will illuminate red. The Filter Indicator LED will turn on in 6-8 months depending how much you use EyeVac Air.
  3. Reset Filter Indicator’s timer after changing the Air Filters.
  4. To maintain the performance of your air purifier, only use official EyeVac Filters. To buy replacement filters, visit EyeVac.com.

Storage

  1. Starting with the vacuum side, touch the Power button, and cycle to the off position. On the air purifier side, touch the Power button and cycle to the off position. Then, unplug the EyeVac Air.
  2. Clean Canister and all filters before storing.
  3. Store EyeVac Air indoors, in a clean, dry place.
  4. Never store EyeVac Air while it is still plugged in. Never wrap cord tightly around the appliance; use the Cord Storage area on the back of the EyeVac Air. Do not put any stress on the cord where it enters the EyeVac Air as it could cause the cord to break.

WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT USE OUTDOORS OR ON WET SURFACES.

TROUBLE SHOOTING

Problem Possible Cause Possible Solution

EyeVac Air will not turn on or respond to button controls.

| ****

1. EyeVac Air is not plugged in.

2.  EyeVac Air is in off position.

3.  The Filters are not in correct position.

4.   There is no power in wall plug.

5.  A Blown house fuse or tripped circuit breaker.

| ****

1. Ensure that all filters are locked and flush in place.

2.  Plug in firmly.

3.  Touch Power button to Manual or Auto position.

4.   Check house fuse or circuit breaker.

5.  Have a qualified licensed electrician replace house fuse or reset circuit breaker.

6.  Remove the Canister to check switch inside cavity above Pre-Motor filter.

Vacuum


EyeVac Air does not pick up debris.

| ****

1. The Inlet is blocked by debris.

2.   The Canister is full.

3.  The debris may be too large for inlet.

| ****

1. Touch vacuum Power button and cycle to turn off the position.

2.  Clean path of dirt near inlet.

3.  Empty the Canister.

4.   Clear any large debris in front of inlet.

---|---|---
The Sensor does not activate.| 1. EyeVac Air is not in Auto mode.| 1. Touch Power button and cycle to the Auto mode.
Vacuum suction not strong.| 1. The Pre-Motor Filter may be need to be cleaned.| 1. Touch vacuum Power button and cycle to turn off the position.

2. Clean all filters with the exception of the Air Filters as needed.

The Status Indicator LED is blinking.| 1. The EyeVac Air sensors have been shut off for 30 seconds which caused power to the motor to shut off.| 1. Touch Power button and cycle to the off position.

2. Clean all filters with the acception of the Air Filters as needed.

3.  Clean sensors with warm water and Q-tip.

DO NOT USE ALCOHOL OR SOAP.

The Canister Full Indicator LED is on.| 1. The Canister is full.| 1. Touch vacuum Power button and cycle to the off the position.

2.  Empty the Canister.

3. Clean all filters with the acception of the Air Filters as needed.

Debris is at inlet before unit is turned on.| 1. The EyeVac Air is not in Auto mode.| 1. Touch Power button and cycle to the Manual position.

2.  Activate EyeVac Air manually.

If your problem is not listed, please contact Customer Support.

Air Purifier

Airflow is significantly reduced.

|

1. The Filters are not in correct position.

2.  The Fan Speed is on low setting.

3.  The Pre-Motor Filter may be clogged by large particles, such as hair or lint, blocking air flow.

|

1. Ensure that all filters are locked and flush in place.

2.  Increase fan speed by touching the Activate button.

3.  With dry cloth gently remove large particles on Air Filter and / or Exhaust Filter.

4.  Make sure there’s at least 15 in / 38 cm of clearance on all sides of the air purifier

5.  Replace the Air Filters.

---|---|---
Air purifier makes an unusual noise while the fan is on.| 1. The Filters are not in correct position.

2.  The EyeVac Air is not on appropriate surface.

3.  The Air Filters needs to be changed.

| 1. Ensure that all filters are locked and flush in place.

2.  Make sure the air purifier is operating on a hard, flat floor with even surface .

3.  Replace Air the Filters.

4.   The air purifier may be damaged, or a foreign object may be inside the canister. Stop using the EyeVac Air and contact Customer Support. Do not try to repair the EyeVac Air.

Poor air purification quality.| 1. Filters are not in correct position.

2.  The Pre-Motor Filter may be clogged by large particles, such as hair or lint, blocking air flow.

| 1. Ensure that all filters are locked and flush in place.

2.  With dry cloth gently remove large particles on Air Filter and / or Exhaust Filter.

3.  Replace the Air Filters.

4.   Close doors and windows while using the air purifier.

5.  Do not use your purifier in an area with

high humidity or while diffusing essential oils.

6.  Contact Support for assistance.

Filter Indicator LED still on after replacing the Air Filter.| 1. If the air purifier not used often, it may take longer to turn off.| 1. See “Replacing the Air Purification Filters” Instructions on pg. 10.
The Air purifier runs intermittently.| 1. Air purifier run time is not set.

2. Air purifier is being activated through vacuum usage for 4 hour cycles.

| 1. Touch Activate button to run the air purifier for an 8 hour cycle.

2.  Long press Power button for 2 seconds to run the air purifier permanently.

If your problem is not listed, please contact Customer Support.

CORRECT DISPOSAL OF THIS PRODUCT

This marking indicates that this product should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling. This appliance is a dry pick-up, canister type vacuum cleaner and air purifier for household and indoor use. It is a general-purpose vacuum cleaner, which can be used for hard floor cleaning. This appliance is an air purifier and deodorizer.

LIMITED WARRANTY

One-Year Limited Warranty. What is covered: JPaulJones, LP warrants to the first retail purchaser of this EyeVac Air that should this product or any part be proved defective in materials or workmanship from the date of proof of purchase for a period of one (1) year, then it will be subject to the terms of this one-year limited warranty. Such defects will be replaced, or credit issued at JPaulJones, LP option, without charge for parts or labor directly related to the defect. Limitations and Exclusions: This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This warranty does not apply to any cost incurred for removal or re- installation, or to any product or part thereof which has suffered through normal wear and tear, alteration, improper installation, physical abuse, misuse, neglect or accident. Nor does it cover defects caused by shipment to JPaulJones, LP or repair or service of the product by anyone other than JPaulJones, LP. Damage resulting from an unforeseen circumstance including but not limited to fire, flood, earthquake, and other natural causes will be excluded. This Limited warranty is in lieu of all other warranties, express or implied either in fact or by operations of law, statutory or otherwise, including, but not limited to any implied warranty of merchantability or fitness for a particular use. JPaulJones, LP does not authorize any other person to assume any liability beyond the warranty herein described. In no event, whether based in contract or tort shall be liable for incidental, inconsequential, indirect, special or punitive damages of any kind from the use of this product. In no event shall be liable for damage in excess of the purchase price. EyeVac Air is not for commercial use. For Warranty Service, submit a Service Request at http://eyevac.com/connect/ or contact: JPaulJones, LP, 7500 Rialto Blvd., Bldg. 1, Suite 122, Austin, TX 78735 or call 512-485-3050.
©2014 JPaulJones, LP Intellectual Property. All rights reserved, JPaulJones, LP, JPaulJones, LP logo and all other marks contained herein are trademarks of JPaulJones, LP Intellectual Property and/or JPaulJones, LP affiliated companies.

JPaulJones, LP

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

eye vac User Manuals

Related Manuals