Panasonic U-36PZH2E5 Air Conditioner Instruction Manual
- June 13, 2024
- Panasonic
Table of Contents
Operating Instructions
Air Conditioner
U-36PZH2E5 Air Conditioner
Model No.
OUTDOOR UNIT
Single Split (Single-phase)
Type PZH2
U-36PZH2E5
U-50PZH2E5
U-60PZH2E5
Type PZ2
U-60PZ2E5
U-71PZ2E5
- Connectable indoor unit lineup
This booklet is the operating instructions for outdoor unit. Regarding the indoor unit, see the operating instructions supplied with the indoor unit.
INDOOR UNIT
4-Way Cassette
4-Way Cassette 60 × 60
Wall-Mounted
Ceiling
Low Silhouette Ducted
Ducted
2 ~ 7
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
**** ACXF55-21950
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
Thank you for purchasing this Panasonic product.
This product is a commercial air conditioner indoor unit.
Installation Instructions attached.
WARNING| This symbol shows that this equipment uses a flammable
refrigerant. If the refrigerant is leaked, together with an external ignition
source, there is a possibility of ignition.
---|---
CAUTION| This symbol shows that a service personnel should be handling
this equipment with reference to the
Technical Manual.
CAUTION| This symbol shows that there is information included in the
Operating Instructions and/or Installation Instructions.
Product Information
If you have problems or questions concerning your Air Conditioner, you will
need the following information. Model and serial numbers are on the nameplate.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
Important Information Regarding The Refrigerant Used
This product contains fluorinated greenhouse gases. Do not vent gases into the
atmosphere.
Refrigerant type: R32
GWP (1)
value: 675 (1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on
European or local legislation.
Please contact your local dealer for more information.
Safety Precautions
The following symbols used in this manual, alert you to potentially dangerous
conditions to users, service personnel or the appliance:
WARNING This symbol refers to a hazard or unsafe practice which can
result in severe personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe practice which can result in
personal injury or product or property damage.
Prohibited matters
Matters to be observed
- Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
- This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
WARNING
Confirm to authorized dealer or specialist on usage of specified refrigerant
type. Using of refrigerant other than the specified type may cause product
damage, burst and injury etc.
This air conditioner has no ventilator for intaking fresh air from outdoors.
You must open doors or windows frequently when you use gas or oil heating
appliances in the same room, which consume a lot of oxygen from the air.
Otherwise there is a risk of suffocation in an extreme case.
Never use or store gasoline or other flammable vapor or liquid near the air
conditioner — it is very dangerous.
Do not use this appliance in a potentially explosive atmosphere. Never touch
the unit with wet hands.
Do not insert your fingers or other objects into the air conditioner indoor
or outdoor unit, rotating parts may cause injury.
WARNING
If the refrigerant comes in contact with a flame, it produces a toxic gas.
For safety, be sure to turn the air conditioner off and also to disconnect the
power before cleaning or servicing.
Pull off the power plug from a receptacle, or switch off the breaker, or
switch off the power disconnecting mean to isolate the air conditioner from
the main power supply in case of emergency.
Dispose of according to national and/or local legislation.
This product must not be modified or disassembled under any circumstances.
Modified or disassembled unit may cause fire, electric shock or injury.
Do not clean inside the indoor and outdoor units by users. Engage authorized
dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself.
Contact to the sales dealer or service dealer for a repair and disposal.
Provide a power outlet to be used exclusively for each unit, and a power
supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current
Device (RCD) for overcurrent protection should be provided in the exclusive
line. Provide a power outlet
exclusively for each unit, and full disconnection means having a contact
separation in all poles must be incorporated in the fixed wiring in accordance
with the wiring rules.
To prevent possible hazards from insulation failure, the unit must be
grounded.
Do not use modified cord, joint cord, extension cord or unspecified cord to
prevent overheating and fire.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater).
Be aware that refrigerants may not contain an odour.
An unventilated area where the appliance using flammable refrigerants is
installed shall be so constructed that should any refrigerant leak, it will
not stagnate so as to create a fire or explosion hazard.
The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
After the unit is installed, never fail to ask the installer for the floor
space of the room where the unit is installed and the refrigerant charge
amount.
In case the unit or the room divider is changed, never fail to consult the
sales dealer or service dealer.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
Do not pierce or burn.
In cases that require mechanical ventilation, ventilation openings shall be
kept clear of obstruction.
WARNING
The appliance shall be stored in a room without continuously operating open
flames (for example: an operating gas appliance) and ignition sources (for
example: an operating electricheater).
Stop using the product when any abnormality/failure occurs and disconnect the
power plug or turn off the power switch and breaker.
(Risk of smoke/fire/electric shock)
Examples of abnormality/failure:
- The ELCB trips frequently.
- The product sometimes does not start when turned on.
- The power is sometimes disconnected when the cord is moved.
- Burnt odor or abnormal noise is detected during operation.
- The body is deformed or abnormally hot.
- Water leaks from the indoor unit.
- Power cord or plug becomes abnormally hot.
- Fan speed cannot be controlled.
- The unit stops running immediately even if it is switched on for operation.
- The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
Do not sit or step on the unit.
You may fall down accidentally.
CAUTION
This appliance is intended to be used by expert or trained users in shops, in
light industry and on farms, or for commercial use by lay persons.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
Keep the fire alarm and the air outlet at least 1.5m away from the unit.
Do not cool or heat the room too much if babies or invalids are present.
Do not turn the air conditioner on and off from the power mains switch. Use
the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is
dangerous because the fan is rotating at high speed.
Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You
may get injured.
Do not stick any object into the FAN CASE. You may be injured and the unit may
be damaged.
NOTICE
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
- The English text is the original instructions. Other languages are translation of the original instructions.
Precautions for Use
Installation
- This air conditioner must be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.
- Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
WARNING
Avoid the following locations for installation.
- Locations where smoke or combustible gas exists. Also locations of extremely high temperature such as a greenhouse.
- Locations where excessively high heat-generating objects are placed.
Attention:
- Avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion)
Wiring
- All wiring must conform to the local electrical codes. (Consult your dealer or a qualified electrician for details.) z Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
- Wiring must be done by a qualified electrician.
Operation Preparation
Turn the power mains on 5 hours before the start of operation.
(For warm-up)
- Leave the power mains ON for continuous use.
NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or
switch off the power disconnecting mean to isolate the air conditioner from
the main power supply when not in use for a long time.
Information for Users on Collection and Disposal of Old Equipment and Used
Batteries
These symbols on the products, packaging, and/or accompanying documents mean
that used electrical and electronic products and batteries should not be mixed
with general household waste.
For proper treatment, recovery and recycling of old products and used
batteries, please take them to applicable collection points, in accordance
with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries correctly, you will help to save
valuable resources and prevent any potential negative effects on human health
and the environment which could otherwise arise from inappropriate waste
handling.
For more information about collection and recycling of old products and
batteries, please contact your local municipality, your waste disposal service
or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in
accordance with national legislation.
For business users in the European Union If you wish to discard electrical and
electronic equipment, please contact your dealer or supplier for further
information.
[Information on Disposal in other Countries outside the European Union] These
symbols are only valid in the European Union. If you wish to discard these
items, please contact your local authorities or dealer and ask for the correct
method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case
it complies with the requirement set by the Directive for the chemical
involved.
Names of Parts
OUTDOOR UNIT
Single Split
Optional
Wireless Remote Controller| Timer Remote Controller| High-spec
Wired Remote Controller
---|---|---
| |
Read the Operating Instructions included with the Remote Controller.
-
Operation
Refer to the Operating Instructions attached to the optional Remote Controller. -
Adjusting Airflow Direction
Refer to the Operating Instructions attached to the indoor unit and optional Remote Controller. -
Maintenance
Refer to the Operating Instructions attached to the indoor unit. -
Troubleshooting
Refer to the Operating Instructions attached to the indoor unit.
Markings for Directive 2014/68/EU (PED)
Rating nameplate figure
Tabulation of Various data
A | U-36PZH2E5 | U-50PZH2E5 | U-60PZH2E5 |
---|---|---|---|
B | 220 – 230 – 240 V— 50 Hz | ||
C | 2.40 kW. 11.0 A | 2.68 kW. 12.0 A | 3.54 kW, 16.4 A |
D | 20 A | 20 A | 25 A |
E | 41.5 bar (4.15 MPa) | ||
F | 27.0 bar (2.70 MPa) | ||
G | 1.15 kg | 1.15 kg | 1.45 kg |
A | U-60PZ2E5 | U-71PZ2E5 | |
--- | --- | --- | |
B | 220 – 230 – 240 V— 50 Hz | ||
C | 3.54 kW, 16.4A | 3.54 kW, 16.4A | |
D | 25 A | 25 A | |
E | 41.5 bar (4.15 MPa) | ||
F | 25.5 bar (2.55 MPa) | ||
G | 1.45 kg | 1.45 kg |
Specifications
Outdoor unit
Single Split Outdoor Unit (R32)
Model Name | U-36PZH2E5 | U-50PZH2E5 | U-60PZH2E5 |
---|---|---|---|
Power source | 220 – 230 – 240 V— 50 Hz | ||
Cooling capacity | kW | 4. | 5.0 |
BTU/h | 12,300 | 17,100 | 20,500 |
Heating capacity | kW | 4.0 | 6. |
BTU/h | 13,600 | 19,100 | 23,900 |
Sound Pressure level (Cooling / Heating) | dB(A) | 43 / 44 | 45 / 48 |
Sound Power level (Cooling / Heating) | dB(A) | 62 / 64 | 64 / 68 |
Unit Dimensions (HXWXD) | mm | 695x875x320 | 695x875x320 |
Net weight | kt: | 43 | 43 |
Operation condition temperature range
- Cooling mode : -15°C~46°C DB • Heating mode : -20°C~18°C WB / -20°C~24°C DB
Model Name | U-60PZ2E5 | U-71PZ2E5 |
---|---|---|
Power source | 220 – 230 – 240 V— 50 Hz | |
Cooling capacity | kW | 6.0 |
BTU/h | 20,500 | 24,200 |
Heating capacity | kW | 6.0 |
BTU/h | 20,500 | 24,200 |
Sound Pressure level (Cooling / Heating) | dB(A) | 46 / 48 |
Sound Power level (Cooling / Heating) | dB(A) | 65 / 68 |
Unit Dimensions (HXWXD) | mm | 695x875x320 |
Net weight | kg | 44 |
Operation condition temperature range
- Cooling mode : -10°C~43°C DB
- Heating mode : -15°C~18°C WB / -15°C~24°C DB
Rated conditions
Cooling : Indoor intake air temp. 27°C DB / 19°C WB. Outdoor intake air temp.
35°C DB.
Heating : Indoor intake air temp. 20°C DB. Outdoor intake air temp. 7°C DB /
6°C WB.
Corresponding language table
Single Split
Model Name
Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level
(Cooling / Heating)
Sound Power Level
(Cooling / Heating)
Unit Dimensions
(H×W×D; mm)
Net Weight (kg)
Panasonic Corporation
http://www.panasonic.com
Printed in Malaysia
© Panasonic Corporation 2018
Authorised representative in EU
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
ACXF55-21950
DC0818-0
References
Read User Manual Online (PDF format)