Manual Door Operation

To Disengage the Opener:

1. It is recommended to do so with the door in the closed position.
2. Pull the manual release cord towards the door, until you hear a click.
3. Move the door manually

CAUTION: When the opener is manually disengaged, the door is no longer locked. To lock the door manually, re-engage the opener after the door is closed.

To Re-Engage the Opener:

  1.  Check the door has not been locked by a locking device.
  2.  Pull the manual release cord away from the door, until you hear a click.
  3.  The door will now operate from the opener

WARNING! Please test the manual release mechanism to ensure that the manual release is easy to operate. No more than 20kg of force should be required to disengage the door using the manual release cord. If excessive force is required, contact your dealer.

Coding a Remote Control

Storing the Remote Control Code:

The GDO-10 Toro TM can store up to 511 transmitters in its memory.

To access the NEXT and SET button, unscrew the screws at the bottom of the logic console cover and remove cover.

  1.  Press NEXT on the console to navigate to Menu 1.
  2.  Press SET to enter the code set procedure.
  3.  Controller will prompt to press one of the transmitter’s buttons.
  4.  Press button 1 to operate the door opener and release.
  5.  Press the same button again as prompted by the display and release.
  6.  Press the SET button to store the transmitter.

Battery Replacement:

Battery Type: 1 x CR2032.

1. To test the battery is working, press and hold a remote button. Check Light Status table to determine if battery needs replacing.

Light Status

| Battery Status
---|---
Solid|

OK

Flashing

| Replace
No light|

Replace

2. Use finger nails to separate the remote casing to expose circuit board.

3. Use a non-metallic object to push the battery down through the side opening to remove the battery.

WARNING! The battery is hazardous and must be kept out of reach of children. The battery can cause severe or fatal injuries within 2 hours
or less if swallowed or placed inside any part of the body. If you suspect the battery has been swallowed or placed inside any part of the body,
SEEK IMMEDIATE medical attention.

Troubleshooting

Symptom Possible cause Remedy
Door will not operate Mains power not switched on.

Door is obstructed.

Door is locked or motor jammed.

Door tracks/hardware damaged.

The stop function is activated

The opener is in “Vacation Mode”

| Switch on mains power. Remove obstruction.

Unlock door or remove jam.

Door requires service/repair by qualified technician

Deactivate the stop switch/timer

Turn off “Vacation Mode”

Door starts to close but automatically reverses to open position| Possible obstruction in the doorway.| Remove obstruction
Door operates from wall control unit (OPEN/CLOSE) button but not from transmitter| Transmitter code not stored in memory

Flat battery in transmitter

| Code transmitter in to openers memory

Replace battery

Door does not close with transmitter| Safety Close Mode is on.

Safety Beam not working properly.

| Turn the Safety Close Mode off Make sure Safety Beam are operational.
Door will not close fully| Door limit positions need to be reset.

Door obstructed and reverses.

| Reset limits positions.

Clear obstruction or adjust force margin

Door will not close fully| Door limit positions need to be reset.

Door obstructed.

| Reset limits positions. Clear obstruction or adjust force margin
Auto-Close not working| Safety Beam not installed.

Safety Beam or wiring faulty. Safety Beam not aligned correctly.

Safety Beam is obstructed.

Door obstructed when closing. Auto-Close time not set.

Auto-Close mode not set

| Install Safety Beam.

Repair Safety Beam or replace wiring.

Re-align optics.

Remove obstruction from path of Safety Beams.

Remove obstruction.

Set Auto-Close times.

Set Auto-Close mode.

Caring for your Opener

Preventative servicing of your garage door and opener, is important. Your garage door is made up of numerous moving parts designed to lift and lower your door safely
and efficiently.

Ongoing preventative servicing ensures that your door continues to function within factory specifications, greatly reduces the risk of failure and repair bills down the track and ensures you maintain your Warranty.

Refer to your Owners Opener Handbook for your service schedule.

Refer to the installation manual for monthly testing procedures in Section 12 to ensure garage door is fit for use.

Need a Service Call?

If the opener needs a service please call the dealer who installed the garage door opener (their contact details are usually on a sticker on the back of your garage door).

Scan: for installation manual

For product assistance,
general enquiry or more information,
please visit:
ata-aust.com.au
or call 1300 133 944.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

b d User Manuals

Related Manuals