ebro TLC700 Digital Probe Thermometer User Guide
- June 13, 2024
- ebro
Table of Contents
ebro TLC700 Digital Probe Thermometer
Before you use it
- Please be sure to read the instruction manual carefully.
- This information will help you to familiarise yourself with your new device, learn all of its functions and parts, find out important details about its first use and how to operate it, and get advice in the event of faults.
- Following the instruction manual for use will prevent damage to the device and loss of your statutory rights arising from defects due to incorrect use. We shall not be liable for any damage occurring as a result of not following these instruc- tions.
- Please take particular note of the safety advice!
Please look after this manual for future reference.
Field of operation and all of the benefits of your new instrument at a
glance
- Fold-out thermometer in pocked-sized
- Probe 60mm
- Splash proof IP65
- Automatic switch off
Temperature measuring of liquids, pastes and semi-solid materials for household, business and hobby, also for food checks according to HACCP and EN13485.
For your safety
-
The product is exclusively intended for the field of application described above.
The product should only be used as described within these instructions. -
Unauthorised repairs, modifications or changes to the product are prohibited.
The product is not to be used for medical purpose or for public information, but is intended only for home use.
Caution!
Risk of injury:
- Keep this instrument and the battery out of reach of children.
- Be careful when using the probe. Always store the instrument folded in.
- Batteries must not be thrown into the fire, short-circuited, taken apart or recharged. Risk of explosion!
- Batteries can be fatal if swallowed. If a battery has been swallowed, get medical assistance immediately.
- Batteries contain harmful acids. Low batteries should be changed as soon as possible to prevent damage caused by a leaking battery.
- Wear chemical-resistant protective gloves and glasses when handling leaked batteries.
Important information on product safety!
- Do not place the unit near extreme temperatures, vibration or shock.
- Only the probe is heat resistant until 220°C.
- Never put the probe directly over fire.
Do not immerse the display device into water. Water can penetrate and cause malfunction. Not suitable for dishwasher.
Getting started
- Open the battery compartment by turning the lid to the left by using a coin and remove the insulation strip. Close the battery compartment again.
- Pull off the protection foil on the display.
- Fold out the probe.
- All LCD segments will light up for about a few seconds.
- The unit is ready for use.
- The sensor is located in the point of the probe. To measure the temperature, insert the probe at least 2 cm in the object.
- The probe has a total angle of 180°.
- Turn off the instrument by folding in the probe again.
When the unit is not in use, it will automatically switch off after 30 minutes also in unfolded state. To activate the instrument again, fold in the probe for 4 seconds and fold it out again. The unit is ready for use.
Temperature indication
- Press the °C/°F button situated inside the battery compartment to change between °C (Celsius) or °F (Fahrenheit) as temperature unit.
Care and maintenance
- Clean with a soft damp cloth. Do not use solvents or scouring agents.
- Remove the battery if you do not use the product for a lengthy period.
- Keep the instrument in a dry place.
insert a new battery CR2032 (+ pole above).
Close the battery compartment by turning the lid to the right using a coin.
Troubleshooting
Problems | Solutions |
---|---|
No display |
- Fold out the probe (first fold in)
- Ensure battery polarity is correct (+ pole above)
- Change battery
Incorrect display|
- Check the position of the probe
- Change battery
If your device fails to work despite these measures contact the supplier from whom you purchased it.
Waste disposal
This product has been manufactured using high-grade materials and components which can be recycled and reused.
Never dispose empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to take them to your retail store or to appropriate collection sites depending to national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal
Specifications
Measuring range temperature: | -30°C … +220°C / -22°F … +428°F |
---|---|
Accuracy | ±0,5°C at -30°C … +100°C, otherwise ±3,0% |
Resolution | 0,1°C |
Operating temperature: | -25°C … +50°C / -13°F … +122°F |
Standards: | EN13485 |
Protection class: | IP65 |
Power consumption: | Button cell battery 1x CR2032 |
Dimensions: | 118 x 33 x 15mm |
Weight: | 41,2 g (incl. battery) |
This product fulfills the guidelines according to EN 13485.
Suitability: S, T (Storage, Transport)
Location: E
Accuracy class: 0,5
Measuring range: -30°C … +220°C
In accordance with EN 13485, this instrument is subject to regular inspections
as
per EN 13486 (recommendation: yearly)
Xylem Analytics Germany GmbH – ebro,
Dr.-Karl-Slevogt-Straße 1 – D-82362 Weilheim