ASC Global Ipcom Cloud GSM Communicator
INTRODUCTION
The IPCOM communicator is perfect solution for monitoring transmission where
wired Internet is available.
By means of the device immediate alarm transmission is guaranteed without any
additional operation cost. According to device type the IPCOM can be connected
to the serial port / telephone line connector of the alarm control panel, it
provides reliable transmission to monitoring station. To use the highest range
of provided functions please read carefully the Installer Manual.
For the confident programming and secure usage please keep all warnings in
Installer Manual, with highly focusing to security directions.
IPCOM LED SIGNALS
LED1: In case of proper power supply, the LED-1 lights continuously.
Flashes | Meaning |
---|---|
Continuous light | Power Supply OK |
Quick blinking | Power Supply problem |
LED2: Provides general fault signal
Flashes | Meaning |
---|---|
No light | Everything is OK. |
Bilking | Reporting failed to monitoring station trough all possible reporting |
channels
Note: Quick alternate blinking of LED 1 and LED 2 means no transmission channel is programmed.
LED3: indicating the state of the telephone line.
Flashes | Meaning |
---|---|
No light | Everything is OK, telephone line changing rely is in normal status |
Blinking | Everything is OK, telephone line changing rely is in active status |
LED4: indicating the state of the Ethernet connection
Flashes | Meaning |
---|---|
Continuous light | Ethernet connection is OK. |
No light | There is no LAN cable connected to communicatior |
Blinking | There is communication problem to monitoring station trough Ethernet |
channel
SYSTEM STRUCTURE
IPCOM communicator receives the Contact ID signals from the PSTN line / serial port of the alarm control panel, or the contacts on its own inputs. These signals are transmitted to the monitoring station through Ethernet network.
OVERVIEW
- Terminal block for connections
- Antenna socket (SMA)
- SIM card holder
- USB connector for programming and debugging
- Serial connector, for IO-84 connection and programming
- Trouble LED (LED-2)
- Power/Signal LED (LED-1)
- GPRS Comm LED (LED-3) GPRS modem
GENERAL RECOMMENDATIONS
Note: In case of communication trouble the IPCOM module switches the
alarm control panel connector to external telephone line connector. So with
appropriate settings (dialing the phone number of central monitoring station)
the alarm control panel will be able to call directly the monitoring station
through external telephone line.
Note: If you want to to use 16 inputs (instead of 8 inputs), the second
IPCOM-IO8 panel should be connected the way above, with placed MODE jumper on
that.
Note: +12 Vdc power supply should be connected to each module separately.
The connection of the devices should be made only with 3 wires cable provided
in device package (RX, TX, GND).
SYSTEM PROGRAMMING WITH PC SOFTWARE
IPCOM module programming is allowed through serial port by default, but after
the appropriate IP settings it can be also configured through Ethernet
network. Please use Terminal software for programming. The programming steps
are the following:
IMPORTANT: In case of old hardware version of IPCOM (without external
telephone line connector) always disconnect +12 V power supply of module
before serial programming !!! Simultaneous usage of +12 V and USB power supply
may damage the programming PC and module.
-
By means of VUP cable and mini USB cable, connect the IPCOM module to the programming PC (for serial programming).
-
Please start Terminal software.
-
Choose the ET (settings) file for programming:
– IP_COMM.ET – IPCOMM module programming -
In Communication / Port Settings menu set the communication port / IP address for programming (default password for IP programming: 1234).
-
By clicking to Communication / Read Data menu you can read settings from device.
The highlighted firmware version means the following (hexadecimal format):
H – 17 (2017)
3 – 10(October)
02 – 2 (Second day) -
Please execute the required settings in Terminal software.
-
Click to Communication / Write Data menu to send the modified settings to device.
Note: During data reading (and sending) IPCOM firmware version can be checked.
TROUBLESHOOTING
TROUBLE: Any abnormal operation in functions during the usage of the
device.
SOLUTION: Firmware upgrade with the newest firmware file usually solve
these kind of problems (see Firmware update part in manual).
TROUBLE: There is no connection between programming PC and IPCOM module
(during serial programming).
SOLUTION: Check the cable plugging in PC side. In programming PC Control
Panel / Hardware / Device Manager application you can check which COM port
appears / disappears in device list during plug / unplug programming cable
(with connected IPCOMM). Please check whether COM port setting is correct in
programming software.
TROUBLE: IPCOM settings seem fine, but communication is not received in
CMS.
SOLUTION: Connect a laptop in place of IPCOM Ethernet cable, and set the
same network settings as
IPCOM has. Then start ipt.exe program to check is it possible to connect to
monitoring receiver from the installation place with the given settings. If
there is no contact check the programmed network settings, and the local
network parameters (rooter, server, switch, etc).
TROUBLE: No communication is received from alarm control panel to IPCOM.
SOLUTION: Check, that the alarm control panel is set to DTMF (Tone) dial
mode, communication should
be enabled, there should be added phone number a client account, additionally
Contact ID (Full) format
should be selected.
TROUBLE: Alarm control panel detects telephone line error, communication
problems.
SOLUTION: In some control panels (in control panel settings) there might
be required to disable
‘telephone line monitoring’ and ‘wait for dial tone’ options. Additionally in
some cases ‘force dial’ option
should be enabled in alarm control panel.
It may help if you connect 1K resistor parallel to control panel TIP / RING
connector.
There might be the following error messages generated in IPCOM communicator:
1354 012 99 = LAN cable is unplugged.
1354 999 99 = Communication problem between alarm control panel and IPCOMM.
1354 001 99 = Communication problem on Ethernet #1 channel.
1354 002 99 = Communication problem on Ethernet #2 channel.
1354 000 99 = Communication problem on all channels in 1-2-3-4-5-6 mode.
1354 100 99 = Communication problem on Ethernet #1 channel in 1-3-5; 2-4-6
mode.
1354 200 99 = Communication problem on Ethernet #2 channel in 1-3-5; 2-4-6
mode.
MONITORING RECEIVER TRANSMISSION TEST
Testing is useful to test data sending from an external installation place. The testing software in the given local network (where the IPCOM will be connected) can help a lot to check monitoring transmission and find the reason of possible problems. For test please use ipt.exe software in the following way:
-
Enter the IP address or Domain name of the monitoring station.
-
Set the ports for communication with monitoring station (Receive Port = Monitoring transmission port;
Shell (Telnet) Port = Remote programming port; Web Server Port = Event list access through web browser port). -
After click to Test button it can be seen that test is successful (PASS) or not (FAIL).
-
If you want you can change the program settings in Options part:
– Enable TCP Test Report = TCP connection test with test message;
– Enable UDP Test Report = UDP connection with test message;
– Invisible TCP/UDP Test = Test message can’t be seen on receiver;
– Enable AES Crypted Test Report / AES Key = Test of AES encryption function.
FIRMWARE UPGRADE
It is recommended to upgrade regularly device firmware to use new functions and eliminate possible bugs. Firmware upgrade can be done by the following steps:
-
Get the latest firmware files from your distributor (IPCOMm.bot).
-
Save settings from the IPCOM with Terminal software (please check 3. System programming with PC
software chapter). -
Start Device Uploader program for firmware upgrade.
-
Choose item (IP) for upgrade (1. STEP), then NEXT.
-
Choose the proper firmware file for upgrade (2. STEP), then NEXT.
-
Choose the COM port where IPCOM is connected (3. STEP), then NEXT.
-
Upgrade process can be started with START button.
-
Do not forget to send back the saved IPCOM settings at the end of the upgrade (please check 3. System programming with PC software chapter).
-
To use new functions it might be required to get the latest Terminal software with the newest ET (setup) files – please download and use newest version.
CONTACT TRANSMISSION THROUGH IP NETWORK
By means of two IPCOM units there is a possibility to transmit contacts through IP network. The inputs of one of the IPCOM units (transmitter) is exactly followed by the outputs of the other IPCOM unit (receiver). The following settings should be configured additionally to general network parameters.
On transmitter side:
Note: In Receiver IP Address field there is the IP address of controlled
IPCOM unit.
Note: With modification of Input 1 / 2 – Loop Type parameter (NO / NC)
you can configure the output activation status of the other IPCOM unit
(receiver).
Note: When you open IP_COMM.ET file, you can select Remote Control option
to set these parameters automatically
On receiver side:
Note: 6200 port (output control is made through this port) should be
allowed for for Port Forwarding in
router settings.
Input 1 of IPCOM on transmitter side controls the Output 1 of IPCOM on
receiver side, Input 2 of IPCOM on transmitter side controls the Output 2 of
other IPCOM.
Note: It is not recommended to use reporting option in IPCOM units which
are used for contact transmission, because in this case reporting might be
very slow.
PROGRAMING
AES Encryption
We can use 128 bit AES encryption for the message sending, which ensures
higher security level.
Email report
The module is capable to send messages via email about input changes, messages
from the alarm panel to one particular email adress. Beside of giving our
email adress, we have to determine an account code,which will be attached in
the email report. Also an email subject is required to set.The email
contains information regarding the event includes the event code (603), (060), and the zone number (001) in case of alarm. To send emails subscription is required at an email server provide
Event filter
The module has the pos sibility to set an event filter. In this way only those
events will be sent which are enabled here.
Input settings
The IPCOM-4G has two I/O ports. In case we use it as an input, we can give the
type of the input (NO/NC), the event code, and the restore code. Moreover, the
input sensitivity can be modified between 10ms and 2550 ms. What is more, it
allows us to link a zone number to the input along with changing the maximum
number of event repeating.
Output settings
The module is equipped with an open-collector output, therefore, the output
switch to the ground In case of control. The outputs can be managed by call or
SMS. In addition, automatic output controls possible as well includes power
fail, channel fault, low signal level, general fault or sufficient power
Level. By default the type of the output is normally close. Also it is not
changeable. The outputs are working in monostable mode, which control time can
be from 1 secundum to 65535 ousecundum.
Control phone numbers
The outputs can be controlled from 8 phone numbers with caller identification.
The outputs can be controller only with caller identification
Individual zone names
In the Zone Names menu, we can name the zones individually. Hence, we can get
SMS or Email notifications from the module with the unique zone names.
Connecting the module to the alarm panel
In the Telco special parameters we can set the details of the communication
between the module and the alarm panel. We must set a number that the alarm
center will dial. Recommended number: 99999999.
The IPCOM-G communicators are connected in most cases to the telco interface
(TIP and RING terminals) of the security control panel. When connected to the
telco interface of a security control panel, the following might be
considered:
IPCOM module registration of the website
(Please check your IPCOM devices Firmware. Cloud connection required LC15 or latest Firmware.)
-
Go to www.ascloudmanager.com website and create an account
-
Enter your email address and password then your name
-
Country settings (for setting module parameters)
-
Select your native language
-
Set the website language
-
Enter Title (Installer / End User / Monitoring Station)
-
Click the ‘I’m not a robot’ box and click ‘Register’
-
After entering the website, click on the “Tools” menu and add our IPCOM module to your account with the
“Add registered device to user” button -
Enter the name of the installation site for easier identification
-
If you already have more than one device, you can assign your new device to “Installation Locations”
-
In the line “MAC / IMEI address of the new module” enter the MAC number of the new IPCOM module and press the “Save” button.
After successful registration, our IPCOM module will appear in the “Tools” list and will be available.
Configure an IPCOM module for output control
A To control the output with a control icon, you need to change the IO
connection points to outputs in the IPCOM module settings. We use the
“Terminal” program for this.
Terminal 2.50 Download
Open Device Manager in your PC operating system Connect your USB cable
compatible with the IPCOM device to the PC and search for the current COM
connection point in Device Manager. Open the Terminal program, then the
IP_COMM.et file shown in the picture and select IP COMM (Ethernet).
Open the “Communication / Settings” menu in the Terminal program, select the
appropriate connection COM port next to the Serial port.
Read the module settings by pressing the “Read” button Find the IO settings
and change the input to output control type, then save the settings by
pressing the “Write” button.
Download Cloud Manager application
Download the Cloud Manager application:
Apple Store
Download
Add control icon in Cloud Manager application
- Make sure you are logged in to the Cloud Manager application with your registered email address. In the Tools menu, a check mark appears at the top of the screen to indicate the logged in status. If there is no check mark, click the enter button and enter your email address and password. (with which you registered the product)
- Select the device you want to control in the Devices list.
- At the bottom of the window that will open, in the Create icon row, click the “>” sign.
- Press the “+” sign in the upper right corner
- Select the cloud icon to create the control button.
- Name the control icon (eg Holiday heater, Home gate, Lighting)
- Select the background color and icon for the control icon.
- Select between IO1 and IO2 and then the output type (monostable / ON / OFF), in case of monostable the output control time. (1-65535s) Clicking the Save button on your control icon is complete, available on the Control Menu in the main menu and ready to use.
IPCOM module at www.ascloudmanager.com
Device status
We can see the current status of the output sor inputs of our device.
Green indicates the cloud connection status of our device
The color green means dormancy. Approaching your cursor displays the name you
entered.
If the status of the output changes, the color will change to red and you will
see an “Offline” message.
You can monitor output or input signal states on your device.
Notifications
There are two types of notifications:
– system notifications, which usually contain important messages about the
server, development, or any
system
– status notifications, where we receive e-mail notifications about the
controls and conditions we have selected to the e-mail address we have also
chosen.
Create notifications
Push the „Add notification” button
Local signal
You can select the output or input of the IPCOM module depending on which one
changes you want to be notified about.
Types you can specify the direction of the output change
OFF->ON Send a notification when turned ON
ON->OFF Send a notification when turned OFF
Notified e-mail address
Select the e-mail address to which you want to send the notification. You can
also personalize the message and subject field.
NOTE!
Depending on the user and e-mail address with which the module is registered,
you may not see an e-mail address or the e-mail address to which you want to
be notified. In this case, select the desired e-mail address from the Users
menu and add the one to be notified for e-mail setup. After saving, log out
and log back in at www.ascloudmanager.com.
Continue setting the notification to the desired email address.
Add an managing users
After registration, the e-mail address provided during registration will be
displayed in the device.
(admin email address)
NOTES!
If you delete this email address from the list of users, we will not see the
device the next time you log in!
If no users are saved to the device, the device will be automatically deleted
from the database in a few days.
You can assign users to your device by entering a user email and password, you
can make personal privileges to them.
The number of users is unlimited, so you can give access as you wish by
entering an email address.
Each user can control the output of the MultiOne GSM module with privileges
e-mail address.
Create new user
To create a new user, you may want to enter a daily email address to be
notified of the status change.
You can enable or restrict notifications.We have the ability to specify the
language used to log in, so all users can easily and conveniently manage the
device.
User: login email address to www.ascloudmanager.com website
Password: new user login password
Password again: password confirmation
Contact name: name for email address (fr identification, greeting)
Email of contact person: You can receive notifications at the user’s
notification email address. If you do not want to be notified, select “I do
not want to be notified”.
Residence (country): Select the country where you live
Preferred language (native): Select your native language
Webpage language: Select the language of the website. When opened, all
functions can be read in this language. Our service is constantly expanding,
currently available in 5 languages. The language of the page can be changed
after logging in.
Role: Select you user status (Enduser, Installer)
Give additional users access. You can give users individual permissions.
Add more users
User: new user email address
Password: new user login password
Admin: Administrator access You have all permissions except to delete the
user who created the permission.
Service: Reading permission, allows access to service data related to the
operation of the module.
Reading: Reading permission
WIFI control: Here we can define what area of use we provide to our user.
If selected, the user can only control the output within the local WIFI
network.
out1: Assign user output to control.
After saving, the settings can be used immediately.
Modify user information
By clicking on the “Set user” button, all user data can be changed. You can change your own or other users’ login passwords. If you no longer need access, you can delete it.
NOTE!
Just as we have created a user, we can delete it. Pay special attention to
deleting the email address created as an admin from the users queue, no longer
seeing the device the next time you log in, and if no users have been saved to
the device, the device will be automatically deleted from the database
Create URL control icon
In URL menu, you can use the “Add new URL” button to create a control icon for
your desktop PC or laptop.
Name the control icon that can be controlled from the PC.
Here you can also specify whether to check the local WIFI availability for
control. If the WIFI limit is enabled, their control icon will only be used
within the scope of the local WIFI network. Turning this off will allow you to
control the output from anywhere with an Internet connection. An excellent
service for allocating rights.
Drag to the screen with the left mouse button and the URL will already operate
the device connected to the output.
You can edit your existing URL connection . You can change your settings or
disable them.
If you no longer want to use it, simply delete it with the appropriate symbol
.
TECHNICAL DATA
Product | IPCOM | IPCOM-S |
---|---|---|
Power supply | 10,5 – 15 Vdc | |
Maximum current consumption | 160 mA | |
Event receiving (through tel. line) | Yes | – |
Event receiving (through serial) | Yes | |
Input / Output | 2 | – |
Output type / Load capacity | Open collector / max. 50 mA | – |
Expansion | up to 16 inputs with IP IO8 modules | |
Ethernet connector | 10 Base-T | |
Event buffer | up to 64 events | |
Operating temperature | 0 °C / 50 °C | |
Sizes (W / L / H) | 48 x 42 x 15 mm | |
Weight | 40 g |