Clarke AC7050 Portable Air Conditioner Instruction Manual

June 13, 2024
Clarke

Clarke AC7050 Portable Air Conditioner

Clarke-AC7050-Portable-Air-Conditioner-product

Product Information

  • Product Name: Portable Air Conditioner
  • Model Number: AC7050
  • Part Number: 3230567
  • Manufacturer: CLARKE

Energy Saving and Unit Safety Protection Tips: For energy saving and safety tips regarding the use of this air conditioner, please refer to section 5 of the user manual.

Electrical Connections: Before connecting the product to the mains supply, please read and follow the electrical safety instructions provided in the user manual. This product is designed to operate on 230V AC 50Hz. Use only the specified power source to avoid damage. The product may be fitted with a non-rewireable plug. If the fuse in the plug needs to be changed, ensure that the fuse cover is refitted. If the fuse cover is lost or damaged, do not use the plug until a suitable replacement is obtained. If the plug needs to be changed, cut it off and follow the wiring instructions provided in the user manual. Ensure that the outer sheath of the cable is firmly held by the clamp. We strongly recommend connecting the machine to the mains supply via a Residual Current Device (RCD). If you are unsure or need assistance, consult a qualified electrician. Do not attempt any repairs yourself.

Product Usage Instructions

  1. Read the user manual thoroughly before operating the portable air conditioner.
  2. Ensure that the voltage of your electricity supply matches the rating plate (230V AC 50Hz).
  3. Check that the fuse in the plug is intact and the fuse cover is securely fitted.
  4. If the plug needs to be changed, cut it off and follow the wiring instructions provided in the user manual.
  5. Make sure the outer sheath of the power cable is firmly held by the clamp.
  6. Connect the machine to a suitable mains socket.
  7. If available, connect the machine to a Residual Current Device (RCD) for added safety.
  8. Switch on the portable air conditioner and set the desired temperature and fan speed using the controls provided.
  9. Ensure proper ventilation around the unit by keeping obstructions away from the air inlet and outlet.
  10. Regularly clean or replace the air filters as instructed in the maintenance section of the user manual.
  11. Follow all safety precautions and guidelines provided in the user manual for safe and efficient operation of the portable air conditioner.

INTRODUCTION

Thank you for purchasing this CLARKE Portable Air Conditioner. Before attempting to operate the machine, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the product giving you long and satisfactory service.

GUARANTEE

  • This CLARKE product is guaranteed against faulty manufacture for a period of12 months from the date of purchase. Please keep your receipt as proof of purchase.
  • This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
  • Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
  • This guarantee does not affect your statutory rights.

ENVIRONMENTAL PROTECTION

  • Recycle unwanted materials instead of disposing of them as waste. All unwanted accessories and packaging should be sorted and taken to a recycling centre for disposal in a manner which iscompatible with the environment.
  • By purchasing this product, the customer is taking on the obligation to deal with its safe disposal in accordance with the Waste Electrical and Electronic Equipment regulations (WEEE). In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.

SAFETY INSTRUCTIONS

  • Carefully read the instructions before operating the unit.
  • This air conditioner is for indoor use only.
  • This air conditioner must be only connected to a 230 V / 50 Hz earthed outlet.
  • Installation must be in accordance with regulations of the country where the air conditioner is used.
  • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
  • This air conditioner has been tested and is safe to use. However, as with any electrical appliance – use it with care.
  • Disconnect the power plug from socket before dismantling, assembling or cleaning.
  • Avoid touching any moving parts within the air conditioner.
  • NEVER insert fingers, pencils or any other objects though the guard
  • This air conditioner can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the air conditioner. Cleaning and user maintenance shall not be made by children without supervision.
  • DO NOT leave children unsupervised with this air conditioner.
  • DO NOT clean the air conditioner by spraying it or immersing it in water.
  • NEVER connect the air conditioner to an electrical outlet using an extension cable. If an outlet is not available, one should be installed by a qualified electrician.
  • NEVER operate this air conditioner if the cable or plug is damaged. Make sure that the power cable is not stretched or exposed to sharp objects/ edges.
  • A damaged supply cable should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
  • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
  • DO NOT use the air conditioner for any other purpose than its intended use.
  • The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
  • Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
  • NEVER use the mains plug or an external timer as a switch to start and stop the air conditioning unit. Use the provided ON/OFF button located on the control panel.
  • Always place the air conditioner on a dry and stable surface.
  • The air conditioner should not be installed in laundry or wet rooms
  • The air conditioner must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
  • Condensation may form on the base of this air conditioner during use, DO NOT use on sensitive or absorbent floors.

R290 REFRIGERANT GAS

  • R290 refrigerant gas complies with European environmental directives.
  • R290 has a low GWP (Global Warming Potential) of 3.
  • The air conditioner contains about 150 g of R290 refrigerant gas.
  • Do not use or store in an unventilated space with an area smaller than 12m² per unit. The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
  • Refrigerant gas may be odourless.
  • Do not use the product and contact the retailer for advice if damage has occurred to the unit which may have compromised the refrigerant system.
  • Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit, the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
  • The refrigerant system must not be perforated or punctured.

ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS

  • Do not cover or restrict the airflow from the outlet or inlet grills.
  • For maximum performance the air conditioner should be situated at least 50 cm from the walls or other objects.
  • Keep the filters clean. Under normal conditions, filters should only need cleaning once every two weeks. Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality.
  • For the initial start-up set the fan speed to maximum and the thermostat to 4-5 degrees lower than the current temperature. Thereafter, set the fan to low and set the thermostat to your desired setting.
  • To protect the unit we recommend the unit should only be used when the room temperature is between 15°C and 35°C.

ELECTRICAL CONNECTIONS

WARNING:  READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THEMAINS SUPPLY.

Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230 V AC 50Hz. Connecting it to any other power source may cause damage. This product may be fitted with a non- rewireable plug. If it is necessary to change the fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to damage, it should be cut off and a replacement fitted, following the wiring instructions shown below. The old plug must be disposed of safely, as insertion into a mains socket could cause an electrical hazard. If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug, proceed as follows.

  • The Blue wire must be connected to the terminal which is marked N.
  • The Brown wire must be connected to the terminal which is marked L.
  • The Yellow and Green wire must be connected to the terminal which is marked E or .

Plug must be BS1363/A approved

Clarke-AC7050-Portable-Air-Conditioner-fig-5

  • We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD)
  • If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

OVERVIEW

Clarke-AC7050-Portable-Air-Conditioner-fig-6

N O DESCRIPTION
1 Air Outlet Flap
2 Control Panel
3 Handle
4 Air Intake
5 Air Outlet Port (for ducting)
6 Air Filter
--- ---
7 Power Cable Storage Hooks
8 Drainage Cap and Plug
9 Plug Storage Socket

CONTROL PANEL AND REMOTE CONTROL

Clarke-AC7050-Portable-Air-Conditioner-fig-7

Clarke-AC7050-Portable-Air-Conditioner-fig-8

  1. Power Button
    • Press the button to turn the air conditioner ON/OFF.
  2. Speed Button
    • Press the speed button to select between High / Low speed.
  3. Temp/Time adjustment buttons
  4. Mode Button
    • Press the mode button to select between cooling / fan and dehumidification.
  5. Timer Button
    • In standby mode, press the button to set the ON time.
    • When the air conditioner is on, press the button to set the OFF time.
  6. Display Window
  7. Remote Sensor
  8. oC / oF Switching Button
    • Press the button to switch between oC / oF.
  9. Sleep/Quiet mode key
    • In cooling mode, press this key to activate the sleep/quiet mode.

CONTENTS

The following components are supplied in the box;

  1. Air Conditioner
  2. Exhaust Duct Set
  3. Remote Control Unit (including 2 x AAA batteries)
  4. Window Kit

Should any loss or damage be apparent, please contact your CLARKE dealer immediately.

INSTALLATION

IMPORTANT: Do not position your air conditioner where it will be exposed to sources of heat above 35oC.

  1. Always transport the air conditioner upright or resting on one side. Remember to drain the tank before moving the appliance.
  2. Position the unit on a level, dry surface at least 50 cm away from surrounding objects.
  3. Screw the air exhaust duct on to the air outlet located on the rear of the air conditioner.
  4. Insert the other end of the air exhaust duct into the window sealing plate.Clarke-AC7050-Portable-Air-Conditioner-fig-10
  5. Move the air conditioner into position and extend the flexible exhaust duct to suit your window layout.
    • NOTE: The length of the exhaust duct is variable between 480 mm and 1500 mm (adaptors included). Using a shorter length of ducting uses less energy.
    • NOTE: The length of duct has been designed to suit the specification of the air conditioner. Do not use an extension or change to a different size duct as it may lead to poor performance.
  6. The flexible exhaust ducting can be bent to an angle if followed by a straight section but tight curves and kinks must always be avoided.
  7. Extend the two parts of the window sealing plate and fit into the window opening, below or beside the window panel as shown above.
  8. Secure in position by closing the window, or if not secure, wedge or otherwise secure the window slider plate so that it cannot fall out.

FITTING BATTERIES

  1. Slide the battery cover away as indicated by the arrow on the rear of the remote control.
    • Fit 2 x AAA batteries into the battery compartment following the polarity diagram inside.

OPERATION

GENERAL OPERATION

  • If the room is exposed to direct sunlight, draw any curtains during the sunniest part of the day.
    1. Press the Power button to switch the air conditioner On/Off.
  • The unit will select the last mode used.

COOLING MODE (COOL)

  1. Press the mode button repeatedly to select COOL.
    • The cool indicator lamp lights up.
  2. Press the Temp/Time adjustment buttons to select the temperature between 16 oC – 30 oC.
  3. Press the speed button to select between High / Low speed.

FAN MODE (FAN)

  1. Press the mode button repeatedly to select FAN.
    • The FAN indicator lamp lights up.
  2. Press the speed button to select between High / Low speed.

NOTE: In fan mode, you cannot set the temperature.

DEHUMIDIFYING MODE (DRY)

Clarke-AC7050-Portable-Air-Conditioner-fig-16

  1. Remove the drain cap / plug from the rear of the air conditioner and connect the drainage hose to the outlet.
  2. Place the other end of the drainage hose into a bucket.
  3. Press the mode button repeatedly to select DRY.
    • The dry indicator lamp lights up.
    • If the room temperature is above 17oC (62oF), the fan will come on.
    • It will go off again if the room temperature drops below 15oC (59oF).
    • In dehumidify mode, the fan runs at low speed and cannot be adjusted.
    • The temperature setting cannot be adjusted in dehumidifying mode.

TIMER MODE

TO SET THE “ON” TIME (IN STANDBY MODE)

  1. Press the Timer button to set the ON time.
  2. Press the Time adjustment buttons to set the ON time (1-24 hours).
    • The timer indicator lamp lights up.

TO SET THE “OFF” TIME (WHEN THE AIR CONDITIONER IS ON)

  1. Press the Timer button to set the OFF time.
  2. Press the Time adjustment buttons to set the OFF time (1-24 hours).
    • The timer indicator lamp lights up.

SLEEP/QUIET MODE

Sleep/Quiet mode will lower the wind speed of the machine and in turn will become quieter, ideal for night time usage.

  1. In Cooling mode, press the Sleep/Quiet mode key on the remote control or press Time Key & Down Key together on the machine.
  2. This will start the Sleep/Quiet mode, with a low wind speed which can’t be adjusted. If you press the wind speed key under Sleep/Quiet mode, the screen will display ‘SL’.
  3. Pressing the Sleep/Quiet mode key again or pressing the Time key and Down key together on the machine will cancel the Sleep/Quiet mode.

FAULT CODES

The following fault codes can be displayed on the control panel.

Code Diagnosis of Fault Action Required
E1 Coil temp is abnormal. Return to CLARKE Service Department.
E2 Room temp is abnormal. Return to CLARKE Service Department.
E4 Anti-freezing protection. None, will recover automatically when the

temperature exceeds 8oC.
FL| Water is full inside the machine.| Drain water from the drain port at the bottom rear of the unit.

DRAINING OFF THE WATER

MANUAL DRAINAGE

  1. When the internal water tank is full, the unit will stop working and show “FL” on the display panel.
  2. Turn off the unit using the power button and unplug from the mains. Try not to move the air conditioner abruptly as this may cause water to spill out from the internal water tank.
  3. Place a tray under the drain port.
  4. Unscrew the drain cap / plug from the drain port and remove the water plug, water will drain from the water tank.
  5. Once drained, replace the drain cap / plug and switch back on.

CONTINUOUS DRAINAGE

  1. Remove the drain cap / plug from the drain port
  2. Use a suitably sized water pipe to connect to the drain port.
  3. You can plumb this pipe into your current plumbing system, lead it outside or use a water pump.
  4. Note: This model has a self-evaporative function, which reduces the need to empty the water tank.
  5. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the selfevaporating facility.

MAINTENANCE

CLEANING

WARNING: PLEASE SHUT OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY MAINTENANCE.

  1. Clean the outside surfaces of the unit with a duster or a soft, moist cloth.
    • Do not use solvents which could damage the plastic components.

CLEANING THE AIR FILTER

Clean the air filter every 2 weeks. If the air filter is blocked with dust, performance will be affected.

Clarke-AC7050-Portable-Air-Conditioner-fig-18

  1. Slide out the air filter as shown.
  2. Wash the air filter gently in warm water with a mild detergent.
  3. Rinse the filter and then dry it gently out of direct sunlight.
    • Make sure the filter is dry before use.
  4. Slide the filter back into position.

END OF SEASON CLEANING

If the air conditioner is not going to be used for a long time:

  1. Drain the internal water tank.
  2. Run the air conditioner in fan mode for 2 hours to dry out the inside.
  3. Switch off the unit and disconnect the power cable. Coil it around the hooks at the back of the machine and set the plug in the socket provided.
  4. Clean the filters.
  5. Dismantle the exhaust ducting and store it safely.
  6. Remove the batteries from the remote control to preserve battery life.
  7. Cover the air conditioner with a plastic bag and store it in a dry place.

TROUBLESHOOTING

Problem Cause Solution
The unit fails to operate Unit is not plugged in. Plug the unit into a

suitable power source.
Water tank is full (display shows “FL”| Drain the water container.
Room temperature is unsuitable.| Check that room temperature

is between 15OC – 35OC

Inefficient cooling| Unit is in direct sunlight.| Draw the curtains
Doors or windows open or another heat source in the room.| Close windows/doors. Remove the heat source.
Filter screen is dirty.| Clean the filter screen
Air inlet or air outlet is blocked.| Remove the blockage
Exhaust air hose not connected properly.| Connect the Exhaust air hose properly.
Noise or vibration| Is the unit standing on an uneven surface?| Stand the unit on a flat, firm surface.
Flowing noise from inside the air conditioner| This normal, it is refrigerant being circulated
Compressor doesn’t work| Heat protection circuit has cut in.| Wait 3 minutes before re- starting unit.
The remote control doesn’t work| The unit is too far away.| Move closer to the unit.
Batteries are flat.| Replace the batteries.
Remote control not pointing at the air conditioner.| Aim the remote control at the unit.

PARTS DIAGRAM

Clarke-AC7050-Portable-Air-Conditioner-fig-19

Number Description
61 Air Filter
65 Remote control
66 Air exhaust flat nozzle
67 Air exhaust hose
68 Air exhaust joint
69 Window sealplate assembly

TECHNICAL SPECIFICATIONS

Model Number AC7050
Power Supply 230V/50Hz
Weight 21 kg
Dimensions (L x W x H) 373 x 684 x 342 mm
Water Sump Capacity 0.95 L
Air Flow Volume 290 m3/h
Operating Temperature 15 – 35oC
Exhaust Duct Diameter 150 mm
Exhaust Duct Length (expanded) 1500 mm
Permissible Excessive Operating Pressure (suction/discharge) 2.8 MPa/0.8 MPa
Max Pressure (Low/High Pressure Side) 3.8 MPa/1.3 MPa
Sound Pressure Level 57 dB LpA
Sound Power Level 65 dB LwA
Energy Efficiency EU Class A
Cooling Capacity 2005 W
Electrical Insulation Class 1
Energy Efficiency rate (EER) 2.61

REFRIGERANT DATA
This product contains hermetically sealed non refillable gas,
Type| R290
Volume| 150 g
GWP| 3
CO2 Equivalent| 0.00045 T

DECLARATION OF CONFORMITY

Clarke-AC7050-Portable-Air-Conditioner-fig-20 Clarke-AC7050-Portable-Air-Conditioner-fig-21

A SELECTION FROM THE VAST RANGE

Clarke-AC7050-Portable-Air-Conditioner-fig-22

Contacts

Clarke INTERNATIONAL

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals