Ecolink FFZB1-ECO Audio Detector Users Manual

June 13, 2024
Ecolink

Ecolink FFZB1-ECO Audio Detector

Ecolink-FFZB1-ECO-Audio-Detector-product

SPECIFICATIONS

  • Frequency: 2.4GHz
  • Battery: One 3Vdc lithium CR123A (1550 mAh) Battery life: 4 years
  • Detection distance: 6 in max
  • 3rd Party Certifications: FCC, IC, ETL
  • Operating Temperature: 32°-120°F (0°-49°C)
  • Operating Humidity: 5-95% RH non condensing
  • Supervisory signal interval: 27 min(approx.)
  • Maximum current draw: 135mA during transmission

OPERATION

The FireFighter™ sensor is designed to listen to the alarm sounder of any smoke detector. Once confirmed as an alarm, it will transmit a signal to the alarm control panel which if connected to a central monitoring station, will dispatch the fire department.

WARNING: This audio detector is intended only for use with smoke detectors but it does not detect the presence of smoke, heat, or fire directly.

ENROLLING (see IMAGE: 1)

To enroll the sensor, set your panel into program mode. Refer to your specific alarm panel instruction manual for details on these menus. Once in program mode, place the battery into the sensor and follow the instructions that appear on the panel. When “Trip to Pair” appears on the screen, press the tamper button to complete the enrollment process. See LED section below for more information on initial power up behavior.

NOTE: For best results, pair the device to your panel before installation.

MOUNTING (see IMAGE: 2 & 3)

Included with this device is a mounting bracket, hardware and double sided tape. To ensure proper operation ensure the side of the device with the small holes is directly facing the sounder holes on the smoke detector.
Secure the mounting bracket to the wall or ceiling using the two mounting screws and double sided tape provided, then secure the audio detector to the mounting bracket using the small screw provided. The

FireFighter™ must be mounting within 6 inches of the detector for optimal operation.

WARNING: Non-interconnected smoke detectors require an audio detector by each smoke detector sounder.

This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72, (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this equipment. Warning: Owner’s instruction notice: ’Not to be removed by anyone except occupant’.

TESTING (see IMAGE: 1)

To test the RF transmission from the mounted position you can generate a tamper by removing the cove. This will send a signal to the control panel. To test the audio detection, press and hold the smoke detector test button. If you are using zone type 16 (Fire with Verification) you must press and hold the smoke detector button for at least 30 seconds to ensure that FireFighter™ has had sufficient time to identify the smoke alarm pattern and lock into alarm. Ensure the FireFighter™ cover is on and that you wear hearing protection.

NOTE: This system must be checked by a qualified technician at least once every three (3) years. Please test the unit once per week to ensure proper functionality.

LED

The Firefighter™ is equipped with a multi-color LED. When a valid audio signal is heard the LED will turn red and flash in sequence to the smoke detector sounder. When the Firefighter™ has determined the audio signal heard is a valid alarm, the LED will turn solid red to indicate it has transmitted to the panel. On power up, the LED will stay solid green for 2 seconds, then blink green 3 times every 5 seconds (approx.) when not enrolled with a panel.

REPLACING THE BATTERY

When the battery is low a signal will be sent to the control panel. To replace the battery:

  1. Remove the top cover to reveal the battery. This will send a tamper signal to the control panel.
  2. Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as indicated on the device.
  3. Re-attach the cover, you should hear a click when the cover engages properly.

WARNING: While the audio detector monitors its own battery, it does not monitor the battery in the smoke detectors. Batteries should be changed as per the original smoke detector manufacturer’s instructions. Always test the audio detector and smoke alarms after battery installation to confirm proper operation
Ecolink-FFZB1-ECO-Audio-Detector-1

FACTORY RESET

REBOOTING AND RESETTING TO FACTORY DEFAULTS

In order to reboot the device, simply remove the battery and place it back in. Upon doing this, you should see the green LED illuminate. See LED section for more information on LED behavior.

To reset the device to factory defaults use the following instructions:

  1. Open case and remove battery from device.
  2. Press and hold tamper switch.
  3. Place battery back into the device while still holding the tamper switch.
  4. When you see the green LED illuminate, release the tamper switch.
  5. After releasing the switch, the device will restore to factory defaults.

PACKAGE CONTENTS

Included Items:

  • 1 x Firefighter Wireless Audio Detector 1 x Mounting Plate
  • 2 x Mounting Screws
  • 1 x CR123A battery
  • 1 x Installation Manual
  • 2 x Double Sided Tape

Non-Included Items: Smoke/CO Detector Security Panel

FCC COMPLIANCE STATEMENT

This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Re-orient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment to an outlet on a different circuit from the receiver
  • Consult the dealer or an experienced radio/TV contractor for help.

WARNING: Changes or modifications not expressly approved by Encore Controls could void the user’s authority to operate the equipment.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance of at least 20 centimeters from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

WARRANTY

Encore Controls warrants that for a period of 2 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmanship under normal use within the warranty period Encore Controls shall, at its option, repair or replace the defective equipment upon return of the equipment to the original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Encore Controls neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. The maximum liability for Encore Controls under all circumstances for any warranty issue shall be limited to a replacement of the defective product. It is recommended that the customer check their equipment on a regular basis for proper operation.

THE LIABILITY OF ENCORE CONTROLS , OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM DETECTOR OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF A SMOKE ALARM DETECTOR AND, IN NO CASE, SHALL ENCORE CONTROLS , OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSSES OR DAMAGES RESULTING FROM THE FAILURE OF THE SMOKE ALARM DETECTOR OR FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.

The Firefighter™ detector does not detect the presence of smoke, heat, or fire directly. It relies solely on the presence of an audio alarm signal generated by an existing smoke or fire detector in proximity to the Firefighter™ detector to make such a determination. The Firefighter™ detector must be used with smoke detectors certified according to UL Standards, and in strict accordance with the installation and operation instructions provided with such detectors. It is the owner’s responsibility to ensure that smoke or fire detectors used in conjunction with the Firefighter™ detector are maintained and tested on a regular basis in accordance with the manufacturer’s instructions. Encore Controls expressly disclaims any responsibility for the failure of the Firefighter™ detector to detect the presence of smoke or fire due to the failure of any smoke or fire detector used in conjunction with the Firefighter™ detector to operate properly due to any condition, including improper installation, operation, maintenance or testing of such smoke or fire detector.

Ecolink Intelligent Technology Inc.

  • 2055 Corte Del Nogal Carlsbad, CA 92011
  • 855-432-6546
  • PN FFZB1-ECO R2.02
  • REV DATE: 2/24/14 patent pending

FAQs

What is the Ecolink FFZB1-ECO Audio Detector?

The Ecolink FFZB1-ECO Audio Detector is a device designed to listen for the siren tone produced by UL listed smoke detectors in your home. When it detects this sound, it sends a signal to your Zigbee HUB, allowing you to receive notifications when your smoke detectors are triggered.

What does the Ecolink Audio Detector work with?

The Ecolink Audio Detector is compatible with Zigbee HUBs such as the Alexa Zigbee HUB (Echo Plus) and the Samsung SmartThings Hub.

How does the Ecolink Audio Detector extend the sound of smoke detectors?

This device does not physically extend the sound of smoke detectors. Instead, it listens for the alarm sounder of existing UL smoke detectors in your home and sends notifications to your Zigbee HUB when they are triggered. This allows you to be alerted remotely.

Is the installation and setup of the Ecolink Audio Detector easy?

Yes, the Ecolink Audio Detector is designed for easy installation and setup. It does not require complex wiring or extensive technical knowledge.

How long does the battery of the Ecolink Audio Detector last?

The Ecolink Audio Detector has a battery life of up to five years, which means you won't need to replace the battery frequently.

Can I use the Ecolink Audio Detector with voice assistants like Alexa?

Yes, it is compatible with voice assistants like Alexa when connected to a compatible Zigbee HUB such as the Echo Plus. This allows you to use voice commands to check the status of your smoke detectors.

What is the main purpose of the Ecolink Audio Detector?

The main purpose of this device is to enhance the functionality of your existing UL smoke detectors by providing remote monitoring and notifications through your Zigbee HUB. It helps improve home safety by keeping you informed about potential fire hazards.

Is the Ecolink Audio Detector suitable for both residential and commercial use?

The Ecolink Audio Detector is primarily designed for residential use, specifically for monitoring UL smoke detectors in homes.

Can I use multiple Ecolink Audio Detectors in the same household?

Yes, you can use multiple Ecolink Audio Detectors in the same household to monitor multiple UL smoke detectors and enhance safety throughout your home.

What should I do if the Ecolink Audio Detector is not triggering notifications correctly?

If you encounter any issues with the device not triggering notifications correctly, you should refer to the user manual for troubleshooting steps or contact Ecolink customer support for assistance.

Can I use the Ecolink Audio Detector with any brand of UL-listed smoke detectors?

Yes, the Ecolink Audio Detector is designed to work with any brand of UL- listed smoke detectors as long as they produce a recognizable siren tone.

Does the Ecolink Audio Detector require a Wi-Fi connection to function?

No, the Ecolink Audio Detector communicates with your Zigbee HUB using Zigbee protocol, so it doesn't rely on Wi-Fi for its operation.

Download This PDF Link: Ecolink FFZB1-ECO Audio Detector Users Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ecolink User Manuals

Related Manuals