Product Information
Part Number | BRI-SECTOR-SELECTOR |
---|---|
Description | Sector Selector |
Wattage | 200 per Sector |
Input Voltage | 12-24VAC/DC |
Capacity | 800W |
Minimum Load | None |
IP Rating | 65 |
Warranty (years) | 3 |
Product Usage Instructions
Installation and Operational Requirements:
1. Ensure that the transformer is powered off before proceeding
with the installation.
2. The Sector Selector door must be closed and latched during
operation.
3. Before installing lamps, make sure the transformer is turned
off. Hotplugging lamps may cause electrical overstress.
4. This product should be used in conjunction with a low voltage
landscape lighting system evaluated by UL1838, with a maximum
output current of 25A.
Technical Requirements:
1. Make sure you have a consistent 2.4 GHz Wi-Fi signal at the
installation location with a dBm strength of -70 or better.
2. Refer to the Brilliance Smart Products Guide for more
information and troubleshooting regarding the Brilliance Smart
App.
Assembly Instructions:
1. Using a Philips screwdriver and the mounting tab screws
provided, attach the mounting tabs to each cabinet corner in a
horizontal position.
2. Position the flat side of Hole A against the Sector Selector
and secure the screw into the recessed side of Hole A so it is
flush with the edge of the cabinet. See Figure A.
SECTOR SELECTOR PRODUCT & INSTALLATION
GUIDE
TABLE OF CONTENTS
SECTOR SELECTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 5 ASSEMBLY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . 6
PROGRAMMING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . 15
FCC CAUTION This device complies with Part 15 of the FCC . Operation is
subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation . Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment . NOTE: This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules . These limits are
designed to provide reasonable protection against harmful interference in a
residential installation . This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications .
However, there is no guarantee that interference will not occur in a
particular installation . If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: –Reorient or relocate
the receiving antenna . –Increase the separation between the equipment and
receiver . –Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected . –Consult the dealer or an
experienced radio/TV technician for help . MPE REMINDER To satisfy FCC RF
exposure requirements, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device
operation . To ensure compliance, operations at closer than this distance is
not recommended .
2
SECTOR SELECTOR
5025307
Part Number: BRI-SECTOR-SELECTOR
DESCRIPTION
Use the Brilliance Sector Selector to create specific zones that can be
controlled independently from a single transformer . The Sector Selector can
split a single transformer into four separate zones with up to 200 watts to
each zone . You can use zones to separate lighting schedules and scenarios to
create special scenes or layers of light in your landscaping . For example,
you can separate the front yard from the back yard, or use zones to
independently control lighting for water/architectural features, outdoor
kitchens, pool and spa areas, outdoor decks or seating areas, or path and
garden lighting .
NEC® Article 411 .5 (B): Lighting systems shall be installed not less than 3m
(10ft) horizontally from the nearest edge of the water, unless permitted by
Article 680 . This product shall be used in conjunction with low voltage
landscape lighting system evaluated by UL1838, with maximum output current 25A
.
STOP!
FAILURE TO FOLLOW INSTRUCTIONS WILL
VOID WARRANTY
3
SECTOR SELECTOR
FEATURES · Compatible with any transformer and works on AC/DC · Create up to
four zones on a single transformer, with up to 200 Watts per sector, and
manage with the Brilliance Smart App · Fitted with two 3/4″ PVC conduit
adapters to accommodate four 12-2 AWG cables · Installs on the low-voltage
side of magnetic transformer · Includes: Sector Selector Enclosure; (4)
Enclosure Mounting Tabs with Screws; (4) Exterior
Mounting Anchors with Screws; High Range Antenna; (20) U Connectors; (2)
Terminal Covers; Sector Chart; Product and Installation Guide
SECTOR SELECTOR SPECS
Wattage
200 per Sector
Input Voltage
12-24VAC/DC
Capacity
800W
Minimum Load
None
IP
65
Warranty (years)
3
12 to 24 vac, 50/60hz, max . 20a each way; 12 to 24 vdc, 50/60hz, max . 20a each way .
resistive, type 1 .b4, class iii, mic4ro-disconnection, 100030 cycles (m3), pti: 175v, pollution 2
2
degree 2, rated impulse voltage: 0 .33kv, overvoltage category: i, raintight .
B
B
11.50
11.50
16.75
16.75
A
A
4
8.50 9.75
8.50 9.75
6.00
6.00
UNLESS OTHERWISE SPECIFIED: UNLESS OTHERW
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/32 ANGULAR: MACH .5 TWO PLACE DECIMAL .01 THREE PLACE DECIMAL .001
DRADWIMNENSIONS ARE TOLERANCES:
CHFERCAKCEDTIONAL 1/3
ANGULAR: MACH ENGTWAOPPPRL.ACE DECI
MFGTHRAEPEPRPL. ACE DEC
INTERPRET GEOMETRIC
Q.AIN.TERPRET GEOMET
PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS
TMTHOPEALRTIENOERRFPAOIRANIRLECMTAINARGTYIOPANENRCD: OCNOTNAFINIDEEDNITNIATLHISCOMTOMALMTEERERANIANTLSC:ING PER
DRAWING IS THE SOLE PROPERTY OF DRAWING IS THE SOLE PROPERTY OF
THE WRITTEN PERMISSION OF
THE WRITTEN PERMISSION OF
WIRING DIAGRAM
Line-Voltage AC Brilliance
Landscape
120 VAC
Transformer
Low-Voltage AC 12-24 Input
Brilliance Sector Selector
Low-Voltage AC 12-24 Output
Brilliance Lamp
INCLUDED ACCESSORIES
(4) Mounting Anchors with Screws
(1) Antenna
(2) Terminal Covers
(4) Mounting Tabs with Screws
(20) U Connectors
INSTALLATION AND OPERATIONAL REQUIREMENTS: Be sure that the transformer is
powered off . The Sector Selector door must be closed and latched during
operation . Before installing lamps, ensure the transformer is turned off .
Hotplugging lamps may cause electrical overstress . This product shall be used
in conjunction with low voltage landscape lighting system evaluated by UL1838,
with maximum output current 25A .
TECHNICAL REQUIREMENTS: Must have consistent 2 .4 GHz Wi-Fi signal at the
installation location with dBm strength of -70 or better . See the Brilliance
Smart Products Guide for more information and troubleshooting regarding the
Brilliance Smart App .
5
ASSEMBLY INSTRUCTIONS
1. Using a Philips screwdriver and the mounting tab screws provided, attach
the mounting tabs to each cabinet corner in a horizontal position .
Position the flat side of Hole A against the Sector Selector and secure the
screw into the recessed side of Hole A so it is flush with the edge of the
cabinet . See Figure A .
A
Recessed Side of Hole A
Flat Side of Hole B
Flat Side of Hole A
Recessed Side of Hole B
The mounting tabs have two holes and two sides . Hole A is used to secure the mounting tab to the Sector Selector . Hole B is used to secure the mounting tab and connected Sector Selector to the installation location .
6
CONTINUED
2. Locate the Antenna Port on the right side of the unit, and thread the
antenna onto the port .
3. Use a torpedo level and mark the tab holes on the wall .
4. Use a 1/4″ drill bit for the pilot holes . Use the Mounting Anchors and
Screws provided to mount the Sector Selector to the surface . 7
CONTINUED
NOTE: The Brilliance Sector Selector is fitted with 2-3/4″ PVC conduit
adapters and will accommodate four 12-2 AWG cables .
5. Pull the input cables from the transformer into the left input side of the
Brilliance Sector Selector .
1 234 1 234
1 234 1 234
6. Pull the output cables into the right output side of the Brilliance Sector Selector .
1 234 1 234
1 234 1 234
7. Strip each 12-2 cable 1/4 inch .
8
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>