Product Information
The teste 106 Food Thermometer is a robust thermometer designed for use in the food industry. It is equipped with a display, an On/Off switch, a reading alarm LED, and a battery compartment located on the rear side. The thermometer comes with an immersion/penetration probe for accurate temperature measurement.
General Information
Please read this document through carefully and familiarize yourself with the operation of the product before putting it to use. Keep this documentation to hand so that you can refer to it when necessary.
Product Description
Safety Information
Avoid electrical hazards.
-
Do not measure on or near live parts
Preserving product safety / warranty claims. -
Operate the instrument properly and according to its intended purpose and within the parameters specified.
-
Do not use force. Do not store together with solvents (e.g. acetone).
-
Open the instrument only when this is expressly described in the documentation for maintenance purposes.
Ensure correct disposal
- Dispose of defective rechargeable batteries and spent batteries at the collection points provided.
- Send the instrument directly to us at the end of its life cycle. We will ensure that it is disposed of in an environmentally friendly manner.
Protect the environment
- The button cell used in the instrument contains 1,2-Dimethoxyethane (CAS 110-71-4). See EC Regulation No. 1907/2006 (REACH) Art. 33
Intended Use
- The teste 106 is a robust food thermometer.
- The product is designed for the following tasks/areas:
- Food sector: Production, food service, spot check measurement
- Measurement of liquids, pastes and semi-solid materials The following components of the product are designed for continuous contact with foodstuffs in accordance with the regulation
- The measurement probe up to 1 cm before the probe handle or the plastic housing. If provided, the information about penetration depths in the instruction manual or the mark(s) on the measurement probes should be noted.
- The product may not be used in the following areas.
- In areas where there is a danger of explosion
- For diagnostic measurement in medicine
Intended Use
The teste 106 is a robust food thermometer.
The product is designed for the following tasks/areas:
- Food sector: Production, food service, spot check measurement
- Measurement of liquids, pastes and semi-solid materials The following components of the product are designed for continuous contact with foodstuffs in accordance with the regulation (EG) 1935/2004
The measurement probe up to 1 cm before the probe handle or the plastic
housing. If provided, the information about penetration depths in the
instruction manual or the mark(s) on the measurement probes should be noted.
The product may not be used in the following areas:
- areas where there is a danger of explosion
- For diagnostic measurement in medicine
Information on standards
This product fulfills with Topsider guidelines in accordance with the EN 13485
standard.
Suitability: S, T (storage, transport)
Environment: E (transportable thermometer)
Accuracy class: 0.5
Measurement range: -50 to +275 °C
According to EN 13485, the measuring instruments should be checked and
calibrated regularly under the terms of EN 13486 (Recommended: Yearly Contact
us for more information.
Initial Operation
- Open battery compartment.
- Insert battery (2 x Type CR2032). Watch out for .
- Close battery compartment.
Operation
If the signal sound is switched on, there will be a sound every time is
pressed and alarm limits are exceeded. If the alarm LED is switched on, it
flashes when upper or lower alarm values are exceeded.
If Auto Off is switched on, the instrument switches off automatically after 10
minutes if no button has been activated.
If Auto Hold is switched on, lashes . Once the reading is stable within a
fixed time duration, it will be frozen. Lights up.
Restart measurement
Switching On/Footswitch on instrument
Switch off instrument Keep pressed
Measuring
Observe required immersion/penetration depth for correct measurement results:
15 mm.
Instrument is switched on. Immerse / penetrate probe into object being measured.
- The current reading is shown.
Holding reading manually
- Hold reading
- Reading is frozen and HOLD lights up. Restart measurement
Exceeding the alarm value
ALARM and (upper alarm Val value exceeded) or (lower alarm value exceeded) light up.
Setting alarm limits
Instrument is switched on.
- Show set upper alarm value () or-Show set lower
- alarm value ()
- Set alarm value
- or . Keep button pressed to increase setting speed.
- Return to measurement: .If necessary repeat the procedure for the upper and lower.
If necessary repeat the procedure for the upper and lower alarm value.
Setting instrument
The instrument is switched off.
- Open configuration mode: Keep pressed. ****
- Select temperature unit (°C or °F): ****Confirm selection
- Switch Auto Hold on or off . Confirm selection ****
If Auto Hold : as been switched on ****
Set time duration (5, 10, 15 or 20s) at which a reading ha to be stable (change lower than 0.2°C) for it to be frozen.
Confirm selection
- Switch sound on or off : . Confirm selection
- Switch Alarm LED on or off . Confirm selection
Switch Auto Off on or off : . Confirm selection
Configuration is complete. The instrument changes to the The instrument
changes to the measurement mode.
Service and Maintenance
Changing the battery
- Open battery compartment.
- Insert battery (2 x Type CR2032).
- Watch out for
- Close battery compartment
Cleaning the instrument
Do not use any aggressive cleaning agents or solutions. Clean the housing and
probe with a damp cloth (soap water .
Questions and Answers
If we have not answered your question, please contact your local dealer or
Test’s Customer Service.
For contact details, please visit www.testo.com/service-
contact
Accessories