testo 106 Food Thermometer Instruction Manual

June 13, 2024
testo

teste  106 Food Thermometer Instruction

teste -106-Food-Thermometer-Instruction-PRODUCT

Product Information

The teste  106 Food Thermometer is a robust thermometer designed  for use in the food industry. It is equipped with a display, an  On/Off switch, a reading alarm LED, and a battery compartment located on the rear side. The thermometer comes with an  immersion/penetration probe for accurate temperature measurement.

General Information

Please read this document through carefully and familiarize  yourself with the operation of the product before putting it to use. Keep this documentation to hand so that you can refer to it when necessary.

Product Description

teste -106-Food-Thermometer-Instruction-PRODUCT

Safety Information

Avoid electrical hazards.

  • Do not measure on or near live parts
    Preserving product safety / warranty claims.

  • Operate the instrument properly and according to its intended purpose and within the parameters specified.

  • Do not use force. Do not store together with solvents (e.g. acetone).

  • Open the instrument only when this is expressly described in the documentation for maintenance purposes.

Ensure correct disposal

  • Dispose of defective rechargeable batteries and spent batteries at the collection points provided.
  • Send the instrument directly to us at the end of its life cycle. We will ensure that it is disposed of in an environmentally friendly manner.

Protect the environment

  • The  button cell used in the instrument contains 1,2-Dimethoxyethane (CAS 110-71-4). See EC Regulation No. 1907/2006 (REACH) Art. 33

Intended Use

  • The teste  106 is a robust food thermometer.
  • The product is designed for the following tasks/areas:
  • Food sector: Production, food service, spot check measurement
  • Measurement of liquids, pastes and semi-solid materials The following components of the product are designed for continuous contact with foodstuffs in accordance with the regulation
  • The measurement probe up to 1 cm before the probe handle or the plastic housing. If provided, the information about penetration depths in the instruction manual or the mark(s) on the measurement probes should be noted.
  • The product may not be used in the following areas.
  • In areas where there is a danger of explosion
  • For diagnostic measurement in medicine

Intended Use

The teste  106 is a robust food thermometer.
The product is designed for the following tasks/areas:

  • Food sector: Production, food service, spot check measurement
  • Measurement of liquids, pastes and semi-solid materials The following components of the product are designed for continuous contact with foodstuffs in accordance with the regulation (EG) teste -106-Food-Thermometer-Instruction-FIG \(6\)1935/2004

The measurement probe up to 1 cm before the probe handle or the plastic housing. If provided, the information about penetration depths in the instruction manual or the mark(s) on the measurement probes should be noted.
The product may not be used in the following areas:

  • areas where there is a danger of explosion
  • For diagnostic measurement in medicine

teste -106-Food-Thermometer-Instruction-FIG

Information on standards
This product fulfills with Topsider guidelines in accordance with the EN 13485 standard.
Suitability: S, T (storage, transport)
Environment: E (transportable thermometer)
Accuracy class: 0.5
Measurement range: -50 to +275 °C
According to EN 13485, the measuring instruments should be checked and calibrated regularly under the terms of EN 13486 (Recommended: Yearly Contact us for more information.

Initial Operation

  • Open battery compartment.
  • Insert battery (2 x Type CR2032). Watch out for .
  • Close battery compartment.

Operation

If the signal sound is switched on, there will be a sound every time   is pressed and alarm limits are exceeded. If the alarm LED is switched on, it flashes when upper or lower alarm values are exceeded.
If Auto Off is switched on, the instrument switches off automatically after 10 minutes if no button has been activated.
If Auto Hold is switched on, lashes . Once the reading is stable within a fixed time duration, it will be frozen. Lights  up.

Restart measurement

Switching On/Footswitch  on instrument

Switch off instrument Keep  pressed

Measuring

Observe required immersion/penetration depth for correct measurement results:

15 mm.
Instrument is switched on. Immerse / penetrate probe into object being measured.

  • The current reading is shown.

Holding reading manually

  • Hold reading
  • Reading is frozen and HOLD lights up. Restart  measurement

Exceeding the alarm value

ALARM and (upper alarm Val value exceeded) or (lower alarm value exceeded) light up.

Setting alarm limits
Instrument is switched on.

  1. Show set upper alarm value () or-Show set lower
  2. alarm value ()
  3. Set alarm value  
  4. or . Keep button pressed to increase setting speed.
  5. Return to measurement: .If necessary repeat the procedure for the upper and lower.

If necessary repeat the procedure for the upper and lower alarm value.

Setting instrument

The instrument is switched off.

  1. Open configuration mode: Keep  pressed. ****
  2. Select temperature unit (°C or °F): ****Confirm selection
  3. Switch Auto Hold on or off . Confirm selection ****

If Auto Hold : as been switched on ****

Set time duration (5, 10, 15 or 20s) at which a reading ha to be stable (change lower than 0.2°C) for it to be frozen.

Confirm selection

  • Switch sound on or off : . Confirm selection
  • Switch Alarm LED  on or off . Confirm selection

Switch Auto Off on  or off : . Confirm selection
Configuration is complete. The instrument changes to the The instrument changes to the measurement mode.

Service and Maintenance

Changing the battery

  1. Open battery compartment.
  2. Insert battery (2 x Type CR2032).
  3. Watch out for
  4. Close battery compartment

Cleaning the instrument
Do not use any aggressive cleaning agents or solutions. Clean the housing and probe with a damp cloth (soap water .

Questions and Answers

teste -106-Food-Thermometer-Instruction-FIG \(4\)

If we have not answered your question, please contact your local  dealer or Test’s Customer Service.
For contact details, please visit www.testo.com/service- contact

Accessories

teste -106-Food-Thermometer-Instruction-FIG \(5\)

Documents / Resources

| testo 106 Food Thermometer [pdf] Instruction Manual
106 Food Thermometer, 106, Food Thermometer, Thermometer
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>