CONLAN C1000LP Low Power Keypad User Manual
- June 12, 2024
- CONLAN
Table of Contents
C1000LP
Art. No.: 480005 (black), 480006 (white)
User Manual C1000LP_usermanual_ENGmar20
Introduction
C1000LP is a low power keypad that works on electronic locks with open
collector or H-Bridge mode.
In standby mode is the yellow LED is lit ( )
By correct code lights yellow and green LED ( )
By incorrect code lights the red LED ( )
C1000LP has a buzzer for indicating while keying, correct code, incorrect etc.
and 2 transistor outputs, independent from each other, so the C1000LP can give
access by code.
The C1000LP is a stand alone unit, the can be programmed directly by Master
code and Service code.
Installation
Mount the reader on a even surface.
Connect the wires to power supply, door strike etc. (use supplied
diode)
Note: Right after applying the voltage all LED’s lights and the buzzer sounds do not touch the reader until the yellow LED lights and the buzzer is silent.
Programming users
Programming the C1000LP is simple and easy to understand.
3.1 User positions
C1000LP has 200 user positions, which can contain a code. The positions are
divided as following:
User position 1 – 100
101 – 150
151 – 190
191 – 200| Function
Activates output 2 (The code is position 1 is 1234 – factory default)
Activates output 1
Activates output 1 and 2
Reserved for special functions
---|---
3.2 Programming user codes
The Master code is used to program/change/delete the users. By default the
Master code is 4711.
LED indication: No light: ○ Lit: Flash: Clear buffer:
New users
To program more users, continue from “Key in the user position” or press to
exit.
Changing codes
It’s the same procedure as programming new users, just overwrite the user
position.
Delete specific users
Delete all users
3.3 Programming codes for special functions
Programming the codes is described in 3.2 and 3.3. This entry activates the
output(s) for 5 seconds (factory setting). Only 1 user can enter at the time.
Programming the same user twice
By programming the same code on the same position twice toggles the output.
(I.e.. the code is entered to unlock the door and entered to lock it again).
Programming the same user 3 times
By programming the same code on the same position 3 times, the output is
designated as switch on only.
(I.e.. the door is permanently unlocked when the code is entered).
Programming the same user 4 times
By programming the same code on the same position 4 times, the output is
designated as switch off only.
(I.e.. the door is only locked when the code is entered).
3.4 Smart enrolling
This position makes it possible to program codes quicker without entering new
positions. Key in a position and it counts automatically to the next position.
Codes can be programmed alternatively as you see fit.
Note: This programming mode overwrites existing positions.
Battery management
Gives a warning before opening the door, when the battery is at approx. 10% charge. Preset Battery low warning (1#):
Position
0 1
2
3
4| Select chemistry
Disable
Alkaline 1,5V
Lithium 3V
Li-poly/Li-ion 3, 7V
Lead Acid 2, 1V| Series cell count
(0,95V) 3-10 cells
(2,3V) 1-5 cells
(3,37V) 1-4 cells
(1,95V) 2-7 cells
---|---|---
Here is an example of how you preset the battery when having a 12V Lead Acid
with 6 cells. See following instructions.
Custom battery low warning (2#):
If you do not have any of the mentioned battery types, you can customize your
battery size. See following instructions.
Here is an example of how you preset the customized battery low warning. In this example we want the battery to send a warning at 10,8V. When the battery is running low it will give you a warning when you type in your user code. The red LED will flash while the buzzer beeps for about 3 seconds. The output is hereafter activated.
Configuration of C1000LP
5.1 The Service code
The Service code is used for C1000LP’s advanced settings such as changing the
Master code and Service code, LED indications and much more. The overview of
the settings and the factory settings can be seen in 4.2 Configuration
overview.
The Service code is 12347890 (factory setting).
Note: Before the Service code can be used must the voltage be turned
OFF and ON (the Service code can now be entered within 10 seconds).
After entering the Service code the reader is in programming mode (the green
LED lights). Each time a setting is made the C1000LP goes back to the previous
point and the next setting can be made.
The navigation is by entering the position/ value followed by #.
5.2 Configuration overview
Position
00
01
02
03
04
05
06
07
08
09
2500
0250| Setting
Master code (1 to 8 digits)
Service code (1 to 8 digits)
LED indications
Output setup
Special functions
Smart enrolling
Input setup
Time
Battery management
Locker reserve time
All codes on the user positions are deleted
Reset to factory default| Factory default
4711
12347890
Normal = Yellow, active = Yellow and green
Output time for 1 and 2 is 5 seconds
---|---|---
5.3 Changing the Master code
By default the Master code is 4711 and can only be used to program, change
or delete users on the C1000LP. To change the Master code, enter the
following:
5.4 Changing the Service code
The Service code is used to configure the C1000LP’s settings.
To change the Service code, enter the following within 10 seconds after power
on:5.5 LED
indications
The C1000LP’s 3 LED’s can be adjusted at will.
To adjust the LED indications enter the following:
| adjust the LED’s for standby indication (normal).
---|---
| adjust the LED’s for correct code indication (active).
| adjust the keying indication (how the LED will react while keying).
To adjust the LED’s press on the following:
1 = yellow LED (toggle by press)
2 = green LED (toggle by press)
3 = red LED (toggle by press)
0 = buzzer (works only on active and keying indication (toggle by press))
= save and go one step back
To save the settings press or press to go back to the previous point (not
saving).
5.6 Output setup
The C1000LP has 2 outputs that can be set to H-Bridge output or open collector
output. By default is the C1000LP set to H-Bridge output with Lock delay in 5
seconds.
To configure the output settings use the following steps:
1 | sets the output 1 time in Pulse mode or Lock delay |
---|---|
2 | sets the output 2 time in Pulse mode or H-Bridge time |
3 | sets the output 1 active position |
4 | sets the output 2 active position |
5 | sets the output functions |
6 | select the outputs for Decode/onetime code |
Please use the configuration scheme under “03” section for correct navigation
for OC setup
Note: In time setting for Pulse mode it is in Molise x 10 instead of
hours.
5.7 Special settings
These settings is used to change the C1000LP’s special functions such as
turning the buzzer on/off etc.
To change these settings, key in:
1 = Service code without timeout ( )
2 = Master code be changed by Master code ( )
3 = Mute reader ( )
4 = Bell on OC1 ( )
5 = Onetime code ( )
6 = Day code ( )
7 = Locker mode ( )
8 = Free locker mode ( )
Special positions
User position 191 to 197 can activate special setting 3 to 6 with a code. The
programming is the same procedure as programming a user code just use the
positions mentioned below:
191 = Toggle buzzer
193 = Reset of free locker
194 = Toggling the star key to activate output 1 (white wire)
195 = Toggle onetime code mode
196 = Toggle Daycode mode
197 = Deactivate the user codes
198 = Seed code
199 = Digit count for one/day code
To save the settings press or press to go back to the previous step (no
saving).
Note: In case of power disruption the special functions will go back to
the setup made by service code.
Blocking
The C1000LP is blocked for 1 minute after 4 incorrect codes.
LED indication:
Manual reset
The C1000LP can be reset to factory default manually.
- Turn the voltage off.
- Connect the yellow and brown wire.
- Turn the voltage on (2 – 16 V DC) the readers LED’s lights and the buzzer sounds.
- Turn the voltage off and disconnect the yellow and brown wire.
The C1000LP is now reset to factory default and the user codes are deleted.
Technical specifications
Voltage range:
Mifare reading:
Output:
Input:
Protection rate:
Color:
Cable:
Dimensions (HxWxD):| 2 – 16V DC
Max. 50 mm
2x open collector, max. 500mA
External buzzer/Feedback (brown) and REX, 0V active (blue)
IP67
Black or white
2,5 meter white, 8 cores
130x50x8 mm
---|---
One time-, day- and period codes
The C1000LP offers 3 advanced code types that can be used either once, for a
day or for a specific period. First, the codes must be generated either via
the Conlang Code Generator (download available at conlan.eu), via the Conlang
Day Code app (available for both Android and iOS), or the website
www.conlan.app
First, enter a seed number. This number can be any number between 1 and
9999999.
Then the code length must be indicated. Here it is best to avoid 4 or 8
digits, so that the codes does not intervene with the service- or mastercode.
Default code length is set to 6 digits.
Conlang Code Generator for Windows
This is for administration of one time and day codes. After you have pressed
enter, a number of one time codes will be shown on the left, the day code at
the top, and future day codes via the calendar. All codes can be exported to a
file if needed.
Conlan
Day Code app
For administration of day codes. The codes can also be sent out either via SMS
or email.
Www.conlan.app
Through this website you can administrate both day codes and period codes.
Period codes can be set to between 1-28 days. The codes can via the website be
sent directly to an email address.
When the information is specified, the C1000LP can be set:
Setting the time
*Code renew time = This is the time on which the one time, day or period codes change to the next day. Default is 00:00. If you don’t want to change the default time, simply press #.
Activation of One-time-/day code
Finally, the reader must know how many digits the one-time-/day codes have and
the seed number. This is done in the same way as programming a user code:
Position 198 is for seed and position 199 is for digits.
Please note: It is important that the seed number in position 198 is the
last to be keyed in. This way all the codes will be generated correctly.
Free locker
The Free locker function can be used for access control, especially for access
control where the user often switches.
Function: Key in a code, and if the cabinet is free, it will lock and can
only be unlocked with the same code.
The locker reserve time function can be set to between 1-255 minutes. This
means that the locker automatically will unlock after a given time. To access
this function, please see the provided configuration scheme for the reader
under position 09.
Free locker reset
The user position 193 will make a reset of the free locker function. Please
see section 5.7 “special positions” in this manual to see line of procedure.