ZSE43 Open Tilt Shock XS Sensor User Manual
FEATURES
- Quick and reliable tilt and vibration alerts to your hub
- NEW 800 series chip for faster communication and more battery life than ever
- Extra small for discreet mounting
- Protective rubber coating
- Powered by a long-lasting single coin battery
- The latest S2 security and SmartStart for secure set-up
- Supports OTA firmware updates
SPECIFICATIONS
- Model Number: ZSE43
- Power: 1 x CR2032 battery
- Operating Temperature: 5°-104° F
- Dimensions: 1.9″ x 1″ x 0.3″
- Range: Up to 130 feet line of sight
- Installation and Use: Indoor or outdoor under eve (can’t be exposed to direct rainfall or sun, a little splash is OK)
INSTALLATION
- POWER THE SENSOR Use the triangle tool to gently open the sensor’s cover and access the battery. Pull the tab from under the battery to activate the sensor. Don’t close the cover just yet. The LED indicator will start blinking for around 10 seconds once the sensor is powered.
The LED indicator doesn’t blink or light up at all?
- Make sure the battery is inserted correctly per the positive / negative pole marks.
- Try a fresh lithium non-rechargeable battery.
- Click the Z-Wave button 3 times as quickly as possible to force inclusion/exclusion mode in case you missed vvhen it first flashed.
Z-WAVE CONTROL
ADD DEVICE to your hub
Initiate inclusion (pairing) in the app (or web interface).
Not sure how? ask@getioot.com If you’re using an
S2 hub, it will ask you to enter the DSK PIN or scan the QR code printed on
the inside of the sensor’s battery cover to complete SmartStart inclusion.
ACTIVATE the sensor
While the hub is looking for new devices, click the Z-Wave button 3 times as
quickly as possible. The LED indicator will start flashing to confirm
inclusion mode and turn off once inclusion is completed.
TIP!
It’s best to add your sensor from the area where it will be installed so the
hub can find the best route to reach it right away. If the signal is weak in
your garage, you may need to add Z-Wave repeaters between the hub and the
sensor.
NEED SOME HELP? ask@getzooz.com
Choose your hub and scan the QR code with your phone’s camera. Then click on
the link to access the step-by-step pairing instructions.
|
---|---
https://www.support.getzooz.com/kb/article/812-how-to-add-your-zse43-tilt-
shock-xs-sensor-to-smartthings/|
https://www.support.getzooz.com/kb/article/811-how-to-add-your-zse43-tilt-
shock-xs-sensor-to-hubitat/
|
https://www.support.getzooz.com/kb/article/816-how-to-add-your-zse43-tilt-
shock-xs-sensor-to-home-assistant/|
https://www.support.getzooz.com/kb/article/815-how-to-add-your-zse43-tilt-
shock-xs-sensor-to-vera/
Get more tutorials and helpful tips at www.support.getzooz.com
TROUBLESHOOTING
The sensor won’t add to your system? Try this:
- Initiate EXCLUSION in your hub and click the Z-Wave button 3 times as quickly as possible.
- Click the Z-Wave button quicker when adding it.
- Bring the sensor closer to your hub, it may be out of range.
- Double-check if the device is powered.
- Get troubleshooting tips specific to your hub at www.support.getzooz.com
EXCLUSION (REMOVE DEVICE)
- Bring the sensor within direct range of your 7-Wave hub.
- Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com ).
- Click the Z-Wave button 3 times as quickly as possible.
- Your hub will confirm exclusion and the sensor will disappear from your controller’s device list.
FACTORY RESET
When your network’s primary controller is missing or otherwise inoperable, you
may need to reset the device to factory settings manually. In order to
complete the process, make sure the sensor is powered, then click the Z-Wave
button twice and hold it the third time for 10 seconds. The LED indicator will
blink continuously. Immediately after, click the Z-Wave button twice more to
finalize the reset. The LED indicator will flash 3 times to confirm a
successful reset.
NOTE: All previously recorded activity and custom settings will be erased
from the device’s memory.
WAKE-UP MODE
The sensor’s wake-up interval is set to 12 hours by default to save battery life. Use the Wake Up Command Class to adjust the interval. Click the Z-Wave button 4 times quickly to wake the sensor up manually. The LED indicator will flash once to confirm the device is awake. During wake-up, the sensor turns the Z-Wave radio on for one minute to receive communication from the hub. Long wake-up interval Will not affect how often the sensor reports to your hub so we recommend leaving the default setting to conserve battery.
ASSOCIATION
The XS Sensor supports Group 1 for Lifeline communication, Group 2 (tilt sensor reports), and Group 3 (shock sensor reports) with up to 5 devices for Basic Set on/off control of the associated devices. The value of the basic set command sent to Group 2 and Group 3 can be adjusted in the advanced settings to customize the sensor’s behavior. Please note that not all 7-Wave systems give users access to direct association settings so if you’re note sure where to find it, please get in touch with our support and we’ll be happy to help.
ADVANCED SETTINGS
Parameter 1: Turn the LED indicator for tilt or shock sensor status change on
or off. Values: 0 – LED won’t blink when either sensor is triggered; 1- LED
blinks only when the shock sensor is triggered; 2 – LED blinks only when the
tilt sensor is triggered; 3 -LED blinks when either sensor is triggered
(default). Size-1 byte dec
Parameter 4: Set the vibration sensor’s level of sensitivity. Values: 0 –
highest level of sensitivity (default); 1 – medium level of sensitivity; 2 –
lowest level of sensitivity. Size: 1 byte dec
Parameter 7: Disable one of the sensor’s reports if needed. Values: 0 – only
tilt sensor enabled; 1- only shock sensor enabled; 2 -both sensors enabled
(default). Size: 1 byte dec Click the Z-Wave button 4 times quickly to wake
the sensor up after updating the settings. We listed the most helpful settings
above. For a complete list of parameters, please go to
www.support.getzooz.com or scan the QR
code for a direct link to all of the settings.
https://www.support.getzooz.com/kb/article/817-zse43-tilt-shock-xs-sensor- advanced-settings/
Not sure how to access advanced settings on your hub? We’ll help! ask@getzooz.com
SENSOR MOUNTING
INDOOR MOUNTING
-
We recommend including your sensor to the Z-Wave network from the location you want to install it.
-
Choose a spot in the area you would like to monitor for vibration which will not be easily accessible to potential intruders, like high on the window glass. For tilt (open/close) reports, locate a clean spot on the top panel of your garage door.
-
Fix the sensor to the surface with the supplied adhesive tape. The sensor will report vibration when the acceleration sensor is tripped and it will change the open/close status when the sensor is fully tilted to the vertical or horizontal position. Make sure you install the sensor with the arrow printed on the back pointing up (and the opening slot facing down). VERTICAL & HORIZONTAL TILT
Attach the back side of the sensor to the surface when mounting it!
The sensor reports open and close alerts for both vertical and horizontal tilting movement. -
Test the sensor by simulating vibration or by opening or closing your garage door.
OUTDOOR MOUNTING
Follow the same steps as for indoor mounting applying additional protection
from water and sun. This sensor is IP64 rated which means it can take a splash
or a drizzle but it can’t be exposed to rainfall, snowfall, or direct sunlight
for prolonged periods of time. We recommend placing the sensor under eve when
using it outdoors.
COMMAND CLASSES
ZWAVEPLUS_INFO_V2 ASSOCIATION_V3 MULTI_CHANNEL_ASSOCIATION_V4
ASSOCIATION_GRP_INFO V3 TRANSPORT_SERVICE_V2 VERSION_V2 MANUFACTURER_SPECIFIC
DEVICE_RESET_LOCALLY POWERLEVEL BATTERY SECURIlt2 NOTIFICATION_VB INDICATOR_V3
CONFIGURATION_V4 WAKE_UP_V2 SUPERVISION FIRMWARE_UPDATE_MD_V5
QUESTIONS?ask@getzooz.com
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This product features the latest Security 2 (S2) framework to remove smart home network hacking risks. This device is equip- ped with a unique authentification code for trusted wireless communication.
WARRANTY
This product should be installed indoors or outdoors under eve upon completion of any building renovations.
- Prior to installation, the device should be stored in a dry, dust- and-mold-proof place.
- Do not install the device in a place with direct sun exposure, high temperature, or humidity.
- Keep away from chemicals, water, and dust.
- Ensure the device is never close to any heat source or open flame to prevent fire.
- No part of the device may be replaced or repaired by the user except for the batteries. This product is covered under a 5- year limited warranty. To read the full warranty policy or file a warranty claim, please go to www.getzooz.com/warranty
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES AND AFFILIATES BE LIABL F FOR ANY
INDIRECT, INCIDENTA_, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, OR DAMAGES
FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DA-MAGES. Z002’S LIABILITY AND CUSTOMER’S EXCLUSIVE REMEDY
FOR ANY CAUSE OF ACTION ARISING IN CON-NECTION WITH THIS AGREEMENT OR THE SALE
OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, |S EXPRESSLY
LIMITED TO, AT ZO002’S OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE
PRICE FOR THAT POR-TION OF PRODUCTS WITH RESPECT TO WHICH DA-MAGES ARE
CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR
THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING
WITHIN THIRTY (30) DAYS FROM ZO0Z’S DELIVERY, OR THE DATE FIXED FOR DELIVERY
IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID
THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE.
SUITABLE FOR DRY LOCATIONS ONLY. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
- This device may not cause harmful interference,
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used according to
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in any given
installation.
If this equipment causes harmful interference to radio or television
reception, the user may try to correct the interference by taking one ar more
of the following measures:
– Reorient or relocate receiving antenna
– Increase the separation between equipment and receiver
– Connect equipment into a separate outlet or circuit from receiver
– Consult the dealer or an experienced radio/TV technician for additional
assistance
All brand names displayed are trademarks of their respective holders.
© Z00z 2023 This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be installed and
Operated with minimum distance 20cm between the radiator&your body.
www.getzooz.com Firmware 2.0
Documents / Resources
| zoOZ
ZSE43 Open Tilt Shock XS
Sensor
[pdf] User Manual
2AZ2V-ZSE43, 2AZ2VZSE43, ZSE43, Open Tilt Shock XS Sensor, ZSE43 Open Tilt
Shock XS Sensor, Tilt Shock XS Sensor, Shock XS Sensor, XS Sensor, Sensor
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>