HOME2 Tonometer Getting Started Guide
iCare HOME2 – Getting Started Guide
Thank you for purchasing iCare HOME2, the gold standard for IOP
selfmeasurement. The iCare HOME2 tonometer is designed for patients to measure
their intraocular pressure at home. iCare HOME2 revolutionizes glaucoma care
by enabling the monitoring of IOP variations throughout the day and the night.
The iCare software provides a comprehensive view of IOP measurement results in
graphical format. Measurement results can be accessed easily with a smart
phone or a web browser. The iCare HOME2 self-tonometer can also be used on its
own. The tonometer provides access to the last 100 measurement results.
To start using the iCare HOME2 and iCare software:
- Follow the instructions in Chapter 1 of this guide to set the language, date and time of your tonometer. This will ensure that the IOP measurement results are stored with the correct local date and time information.
- Follow the instructions in the iCare HOME2 Quick Guide to learn how to take measurements with the iCare HOME2. Please also view the iCare HOME2 User Instructions Video provided on the USB memory stick in the iCare HOME2 carrying case.
- For patients – To use iCare HOME2 with iCare software, follow the instructions in Chapters 2 and 3 of this guide.
- For healthcare professionals – To use iCare HOME2 with iCare software, follow the instructions in Chapters 2 and 4 of this guide.
You can find the instruction manuals and quick guides for the iCare HOME2 and
the iCare software in the iCare HOME2 product package.
Should you have any questions, please contact an iCare distributor, your
healthcare professional or home-software-support@icare-world.com.
Setting the language, date and time
1. 1 Set the Language
-
Press and hold down to switch on the tonometer.
-
Press until you see SETTINGS on the display.
-
Press .
-
Press or until you see LANGUAGE.
-
Press to change the language.
-
Press or until you see the language you want, and press
1.2 Set the Date -
To change the date, press or until you see DATE.
-
Press .
-
Press or until you see the date format you want, and press .
-
Press or until you see the year you want, and press .
-
Press or until you see the month you want, and press .
-
Press or until you see the day you want, and press .
1.3 Set the Time -
To change the time, press or until you see TIME.
-
Press .
-
Press or until you see the time format you want, and press .
-
Press or until you see the time zone you want, and press .
-
Press or until you see the hour you want, and press .
-
Press or until you see the minutes you want, and press .
iCare software system overview
The iCare software system consists of the following:
- iCare HOME2, a self-tonometer for measuring eye pressure.
- iCare CLINIC, a cloud-based software service, managed by healthcare professionals. With iCare CLINIC, the healthcare professional and patients can view and analyze iCare HOME2 measurement results on a browser.
- iCare CLOUD, designed for patients, to create a private account for storing iCare HOME2 measurement results.
- iCare PATIENT2, a mobile application designed for patients to view IOP measurement data. iCare PATIENT2 can also be used by patients or healthcare professionals for uploading data to iCare CLINIC or to iCare CLOUD.
- iCare EXPORT, a PC application for Windows OS. iCare EXPORT can be used for viewing IOP data and uploading data to iCare CLINIC or to iCare CLOUD.
NOTE! The iCare HOME2 tonometer can be connected to either iCare CLINIC or iCare CLOUD, but not both. Patients can store their measurement data to a private account in the iCare CLOUD, if their tonometer is not registered to a healthcare professional’s iCare CLINIC account.
[For Patients] Registering the iCare HOME2 and starting to use iCare
software
In order to see your iCare HOME2 measurement results in a smart phone or with a web browser, the iCare HOME2 tonometer needs to be registered either to:
- an iCare CLINIC account or
- your private iCare CLOUD account.
Consult your healthcare professional, whether he or she has an iCare CLINIC
account to which the iCare HOME2 has been or can be registered.
Once the iCare HOME2 has been registered to an iCare CLINIC account, your
healthcare professional can provide you with iCare patient credentials. With
those you can then access your measurement results in the iCare PATIENT2 app,
or with a web browser.
If the iCare HOME2 tonometer is not registered to an iCare CLINIC account, follow the steps below for setting up your private iCare CLOUD account:
- Go to www.icare-world.com/cloud/registration/
- Start by selecting your country.
- Accept the terms of use by clicking all the checkboxes and enter your email address.
- You will receive an email. Click the activation link.
- Complete your registration by filling in the information required on the webpage, including your chosen password. You can find the device’s serial number on the back of the tonometer.
- You will receive a registration confirmation email. The email includes the web address to access your iCare CLOUD account.
- The same iCare credentials can be used to log in to the iCare PATIENT2 mobile app.
For taking the iCare PATIENT2 app into use with your tonometer, follow the
instructions in the iCare PATIENT2 and EXPORT Quick Guide.
For taking the iCare EXPORT PC application into use with your tonometer,
follow the instructions in the iCare PATIENT2 and EXPORT Quick Guide.
You can download the iCare EXPORT PC application from https://www.icare-
world.com/apps/export/
The iCare EXPORT works in Windows OS.
If you want to unsubscribe from iCare CLOUD, contact home-software-support
@icare-world.com.
[For professionals] Start using the iCare software
The iCare CLINIC software can be used to manage the loaning of your iCare HOME
and HOME2 tonometers to patients, and for viewing, analyzing and reporting IOP
measurement results.
For more information about iCare CLINIC, visit: www.icare-world.com/product
/icare-clinic-software/
For subscribing to iCare CLINIC, visit: https://store.icare-world.com/
For adding your iCare HOME2 tonometer to iCare CLINIC, follow the instructions
in the iCare CLINIC, EXPORT and PATIENT Instruction Manual for Professionals.
Also, the iCare EXPORT PC application can be used for viewing IOP measurement
results. It can also be used for creating a simple measurement report in table
format.
You can download the iCare EXPORT PC application from: https://www.icare-
world.com/apps/export/
You can find the iCare CLINIC, EXPORT and PATIENT Instruction Manual for
Professionals on the USB drive in the HOME2 product carrying case.
Icare Finland Oy
Äyritie 22
01510 Vantaa, Finland
Ph. +358 0 9775 1150
info@icare-world.com
For further information, read the instruction manual.
**** 0598
iCare is a registered trademark of Icare Finland oy. Centervue S.p.A, Icare Finland Oy, and Icare USA Inc. are parts of Revenio Group and represent the brand iCare. Not all products, services or offers referenced in this brochure are approved or offered in every market and approved labeling and instructions may vary from one country to another. Product specifications are subject to change in design and scope of delivery and as a result of ongoing technical developments.
References
- iCare products and services for modern and reliable ocular diagnostics
- Home USA | Icare mHOME
- Home - World Accelerator
- iCare Registration
- iCare CLINIC - iCare
- Home USA | Icare mHOME
- Export - iCare
- iCare Registration
- iCare CLINIC - iCare
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>