RED Portable 512 Power Station User Manual
- June 12, 2024
- RED
Table of Contents
PORTABLE 512
POWER STATION
USER MANUAL
Portable 512 Power Station
Thank you for purchasing the Red-E 512 Power station.
This Power Station is built with special emphasis on safety and reliability.
It uses LiFePO4 batteries, has built-in BMS (Battery Management System)and
provides protection against power surges, high temperature and short circuits.
The Red-E 512 supports a pass-through UPS function and has a LiFePO4 battery
that is guaranteed to have 80%+ capacity (400wh) after 3000 cycles,(which is
recharging the power station once a day for 8 years).
What’s included
Product Introduction
This product is a portable power device with a built-in battery pack with
charge/discharge function.
Features:
- AC Output: South African 3 prong plug
- DC outputs include: USB output and cigarette lighter output.
- Meets most usage application scenarios including: 3 prong plugs, USB-A, Type-C PD3.0 and cigarette lighter output.
- Includes a display, interface control, protection and alarm.
- This product can be recharged by mains AC, solar panels and vehicles, while charging other devices.
- Equipped with safe EVE brand LiFePo4 battery
- Large battery capacity of 512Wh
- 800W pure sine wave AC output that can run most electronic equipment and small household appliances.
- Two-way fast charging technology to fully charge the product within 2 hours.
- Seamless switching in UPS mode with 10ms switchover time.
- Multiple safety features such as battery protection, circuit protec-tion, over voltage and over temperature.
Usage
Will power up to max of 800w. Devices include:
Precautions For Use
- To avoid shortened battery life and other failures, please avoid long-term storage and use of this. product in environments with high temperatures and humidity or direct sunlight.
- Keep product away from fire or heat source.
- Do not disassemble or modify the product in any way.
- Store or use this product out of the reach of children.
- Only use original accessories. Failure to do this may affect the guar-antee.
- Please plug the charge cable directly into the wall socket when charging and do not use extension cords.
- Turn off and unplug the power cable when the product is not in use.
- If the product needs to be stored for a long period of time, please:
1. Charge the battery fully and then completely discharge the product by using it.
2. Recharge the product to about 50% and store it.
3. Please repeat this process every 6 months to prolong the battery life.
2 Year Warranty
This RED-E Product is warranty against any manufacturing defect for the
duration of the warranty. This warranty excludes normal wear and tear through
regular use or if the product has been subjected to abuse by the user
(including liquid damage). Please retain proof of purchase as the guarantee
will only be honoured if returned with an invoice.
Button Function Introduction
-
Power ON/OFF Button
-
USB ON/OFF Button
-
LED Light Button (Switch to different mode)
-
DC ON/OFF Button
-
LCD Screen
-
Cooling Air Duct
-
AC ON/OFF Button (50/60Hz switch)
-
XT60 Input Port ( for solar panel)
-
AC input
-
Power ON/OFF Button
• Press and hold the power button for 3 seconds to activate the system and turn on the LCD display.
• Press and hold again for 3 seconds to turn it off. -
USB ON/OFF Button
• Short-press the USB button to turn on the USB output port, and short press again to turn It off. -
LED Light Button
The light has 3 functions.
1. Short-press the Light button to turn the LED light on.
2. Short-press again to enter SOS mode.
3. Short-press again to enter strobe mode.
4. Short-press again to switch off the LED light.
5. During any mode, press the LED button for more than 1 second to switchthe light off. -
DC ON/OFF Button
Short-press the DC button to turn on the DC output port, and short press again to turn it off. -
LCD Screen
Displays the product’s battery level and usage information.
-
Cooling Suction and Exhaust Port
When the product reaches the pre-set temperature threshold, the cooling fan will automatically be activated, accompanied by a fan noise (fan noise below 60dB is normal).
• Do not block the cooling import and exhaust port when the product is in use.
• Do not place any object within a range of 30cm around the power station. -
AC Button (AC output port, the sum of electrical load power should be <800W)
• Press the AC button to activate the AC Output function (the unit will not function unless you’ve turned it on; and also pressed the AC button); To turn off, press and hold.
• This unit operates at 50 Hz.
• Should you wish to change the frequency, press and hold the AC button for 2 seconds to enter the frequency switching mode, the 50Hz or 60Hz icon will flash on the display.
• Short-press the AC button again to select SOHz or 60Hz.
• When the icon stops flashing it will displays SOHz or 60Hz. This will be the frequency the unit will run at. -
XT60 Port
This interface supports solar panel input or car charger input. It can support a wide range of input voltages ranging from 11.5v to SOv. For details, please refer to “Solar Panel Connection” and “Car Charging” in this manual. -
AC Input
If being charged from a household plug socket, the Power Station can reach a super-fast charging speed of 400W. This will enable the product to be fully charge from 0-100% in 1.5 Hours. When charging in this way, please pay attention to the following points:
• Plug the power station directly in the wall socket to charge the product. Do not use extension cords as this can be a fire hazard.
• If you have to use an extension cable to charge the power station ensure that NO other appliances are plugged into the same extension cable plug at the time of use to avoid tripping the household plug socket.
NB. Overload Protection
The overload protection function (safety circuit breaker) will be activated
when the power supply current is unstable due a large current input at the AC
input or lightning, etc. This is necessary to protect the product and cut off
the AC input port.
Please follow the sequence below to restore the AC input function:
- Turn off the power button and unplug all ports.
- After confirming that there is no abnormality in each port, turn on the power button.
- Connect the AC Cable to restore the AC input.
Display Interface.
- Charging/Using time
- Total Input power
- Battery Progress Bar
- Battery Level Percentage
- Total Output power
- LED Light
- AC Output
- DC (12V) Output
- PD3.0 Output
- USB Output
- Fan Status
- Cigar Lighter (12V) Output
- XT60 Input
- Connected to the AC Mains
- High/Low Temperature Protection
Screen Display Description
Power display:
- When the product is in the charging state, the battery progress bar rotates clockwise and the battery level percentage gradually increases.
- When the product battery level is 0, the battery level percentage icon flashes.
- IInput and output status: When the product is in-use, the total input power, total output power and the cursor corresponding to the working area will be displayed on the screen.
Troubleshooting Table
| Cause| How to fix
---|---|---
The above output icon flashes and beeps.| The output exceeds the standard and
has short-circuited.| Remove the load, and then short press the switch in the
area that corresponds to the icon to turn off the alarm.
The temperature warning icon flashes and beeps.| The temperature of the
product is too high or too low.| Take the product out of the charging state
and remove anything plugged into the device.
Turn the power off and wait for thedevice to reach a suitable working
temperature. The alarm will then switch off.
AC input connection icon flashes and the product cannot be charged.| The
overload protection function is enabled.
properly.| Disconnect all the loads and make sure everything is connected
UPS Mode
This product has a UPS (Uninterrupted Power Supply) function. This allows you
to use the device to power items while the unit recharges.
The usage and operation precautions are as follows:
See Pic 1 below: when connected to the AC Mains power supply, via the AC
input, the Power Station will enter UPS working mode. This means that the unit
will power the AC electrical appliances in bypass mode and recharge the unit
at 400w of power. In this working state, the rated power of the electrical
appliance must be lower than 800w otherwise overload protection may be
triggered.
See Pic 2 below: When the AC mains is off, the bypass stops working and the product switches over to the inverter circuit within 10ms (1/10th of a second). This will enable the UPS mode and will continue to supply power to the electrical appliances uninterrupted and will work as normal within the specs of the power station.As soon as AC power is restored, it will enable the UPS working mode again.
Connection of Solar Panels
Under the correct light conditions, this product can be recharge via solar
panels. The recharge power is determined by the equipment (solar panels) and
weather conditions.
In this charging mode, the power station can be recharge at a speed of up to
200w. The maximum input voltage is 50v. Please make sure you are using the
correct solar panels and solar panel configuration.
The input voltage cannot exceed 50v as this will damage the device, and this
is not covered by the warranty.
- We recommend the following two charging methods using RED-E solar panels:
Method one Method two
Car Charging
- Connect the car charging port to the power station XT60 port. • Connect the other end of the car charging cable to your car power source such as a cigarette lighter. The connection method is shown in the picture below.
This product supports 12V/24V car charger charging, please note the following when car charging:
- Only charge the device through your car when it is running, other-wise it may discharge your car battery.
- Vehicle charging power is usually in the range of 90W-120W, and it can take up to 6 hours to charge the power station. If fast charging is required, the AC mains charging is recommended.
Product Specifications
Product Name | 512Wh Portable Power Station |
---|---|
Dimension | LWH=272184.5240mm |
Weight | 6.5kg |
Capacity | 512Wh |
AC Recharging | AC Mains Input, 400W max |
XT90 Input | 11.5-50V 8A below 200W max |
AC Output | 50/60Hz (switchable), rated 800W, pure sine wave with overload, |
short circuit protection
USB-A Output| (QC3.0 18W)X2
Type-C ① Output| (PD2OW) X2
Type-C ② Output| (PD100W)X1 Included PD3.0 protocol
DC 5521 Output| 12V/10A
Car Charging Output| 12V/10A
Shutdown Current| <500uA
Working Temperature| -10∼40°C
Environment Humidity| ≤ 90°/oRH
Cycle Times| > 3500 times
Battery Specification
Cell type | 40135 Li FePo4 |
---|---|
Rated voltage of single battery | 3.2V |
Rated capacity of single battery
Rated voltage of battery pack
Output voltage range of the battery pack| 20Ah 25.6V
21-29V
Rated capacity of battery pack| 512Wh
Disclaimer
Please read the user manual of this product before use to ensure full
understanding and correct use and keep the user manual for future reference.
Failure to operate this product correctly could cause serious injury to
yourself or others, or result in damage to the product and property. Once you
use this product, you are deemed to have understood, recognized and accepted
all terms and content of this document. Users undertake to be responsible for
their own actions and all consequences arising therefrom. Red-E is not
responsible for any loss caused by the user’s failure to utilise the product
in accordance with the User Manual.
www.red-e.co.za
INNOVATION – QUALITY – GUARANTEED
Documents / Resources
| RED
Portable 512 Power
Station
[pdf] User Manual
Portable 512 Power Station, Portable 512, 512 Power Station, Portable Power
Station, Power Station
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>