Front
**
Dimensions
** Product installation
-
Connect the gooseneck on the XLR base
-
Plug RI45 cable (category 6) on “COM 01″ input
-
Then plug it on “PAGING” port on amplifier
-
Start the console with the switch “POWER – ON”
-
Choose one or more zones for broadcast
Green LED blinks = zone selected -
Press once the button “CALL” to speak
Press “CALL” again to stop broadcasting
To access to full user manual, go on www.bouyer.com (product page of SA-1127 / user manual)
Specification
directivity: cardioid
Impedance: 6000
gooseneck: 40cm
power: SA-1127 ou SA-1247 24V phantom through SA-1127 or SA-1247
consumption : 3W
AUX input: 350mV / 10k Q
color : black
material : metal
weight : 900g
Please make sure to read carefully all following instructions
-
Take a look at all the warnings. Don’t remove the security tags on the device or other information.
-
Use the device only for indicated applications, and in an appropriate way.
-
The use of this device is not recommended above 2000 meters above sea level.
-
Don’t obstruct aeration openings with some objects.
-
Respect a minimal distance around the device to ensure enough aeration.
-
Don’t expose the device torain or moisture (except if the device is conceived for outdoor use in this case, you must respect the instructions which come with it).
-
If your device doesn’t work anymore, and if water or other objects enter inside, turn it off directly and unplug it. This device must be repaired by a qualified person.
Devices plugged on mains power -
Tun off the device before touching any conductive parts inside it.
-
Don’t switch the device on-off several times in a row : yourisk to reduce the longevity of s intern components.
-
Replace the fuse only by a fuse with the same type and the same caliber.
-
Warning, a power plug has three spindles, including a protection ground spindle. The third spindle ensures safety. Check if the protection ground spindle provided enters in the electrical outlet, otherwise, consult an electrician to replace the obsolete outlet.
Warning symbols
| Protection ground spindle
---|---
| Ground spindle
| Direct current or continuous voltage
| Alternating current or Alternating voltage
| Dangerous voltage by touch, risk of electrification, even electrocution
| Read carefully the joined document
| Warning, hot surfaces, dor’t touch during operation, risk of burns
Devices which are excessive thermal energy sources
Warning, hot surfaces, don’t touch during operation, risk of burns
Au devices such as loudspeakers
High sound pressure, risk of hearing damage, do not listen at high volume
levels for extended periods (greater than 90 dB).
Product’s disposal
At the end of product’s life ,if it is installed on the French territory (DOM-
TOM included), please contact BOUYER to organize its destruction according to
the WEEE directive. Otherwise, please follow country’s local regulations to
install the product.