ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel User Manual

June 12, 2024
ILUMINARC

User Manual
ILUMIPANEL ML Model ID: ILUMIPANELML

ILUMIPANEL ML Outdoor Rated LED Panel

Edition Notes
The Ilumipanel ML User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the Ilumipanel ML as of the release date of this edition.

Trademarks
ILUMINARC, the Iluminarc logo and Ilumipanel ML are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.

Copyright Notice
The works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet. © Copyright 2021 Chauvet & Sons, LLC. All rights reserved. Electronically published by Chauvet in the United States of America.

Manual Use
Chauvet authorizes its customers to download and print this manual for professional information purposes only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this manual or its content for any other purpose without written consent from Chauvet.

Document Printing
For best results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. If using A4 paper (210 x 297 mm), configure the printer to scale the content accordingly.

Intended Audience
Any person installing, operating, and/or maintaining this product should completely read through the guide that shipped with the product, as well as this manual, before installing, operating, or maintaining this product.

Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.iluminarc.com.

Document Revision
This Ilumipanel ML User Manual is the 1st edition of this document. Go to www.iluminarc.com for the latest version.

Before You Begin

What Is Included

  • Ilumipanel ML
  • Quick Reference Guide

Claims
Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection. For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Text Conventions

Convention Meaning
1–512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
A key to be pressed on the product’s control panel

Symbols

Symbol Meaning
Critical installation, configuration, or operation information. Not

following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
| Important installation or configuration information. The product may not function correctly if this information is not used.
| Useful information.

Any reference to data or power connections in this manual assumes the use of proprietary IP67-rated cables.
The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol.

FCC Compliance
This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Safety Notes
Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product.
This product contains no user-serviceable parts. Any reference to servicing in this User
Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs.
All applicable local codes and regulations apply to proper installation of this product.

Personal Safety

  • Avoid direct eye exposure to the light source while the product is on.
  • Always disconnect the product from the power source before cleaning.
  • Always connect the product to a grounded circuit to avoid the risk of electrocution.
  • Do not touch the product’s housing when operating because it may be very hot.

Mounting and Rigging

  • The luminaire is intended for professional use only.
  • The product should be positioned so that prolonged staring into it at a distance closer than 3.3 ft (1 m) is not expected.
  • Do not submerge this product (IP67). Temporary outdoor operation is fine.
  • When using this product in an outdoor environment, use IP65 (or higher) rated power and data cables. Secure unused power and data ports with attached IP65 covers.
  • CAUTION: When transferring product from extreme temperature environments, (e.g., cold truck to warm, humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
  • Not for permanent outdoor installation in locations with extreme environmental conditions. This includes, but is not limited to:
    • Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
    • Locations where the normal high or low temperatures exceed the temperature ranges in this manual.
    • Locations that are prone to flooding or being buried in snow.
    • Areas where the product will be subjected to extreme radiation or caustic substances.
  • Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • Make sure there are no flammable materials close to the product when operating.
  • When hanging this product, always secure to a fastening device using a safety cable.

Power and Wiring

  • Make sure the power cord is not crimped or damaged.
  • Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • Never connect this product to a dimmer pack or rheostat.
  • Make sure to replace the fuse with another of the same type and rating.
  • Never disconnect this product by pulling or tugging on the power cable.
  • If the external flexible cable or cord of this product is damaged, it shall be replaced with a special cable or cord exclusively available from the manufacturer or its service agent.
  • The light source contained in this luminaire shall only be replaced by the manufacturer, its service agent, or a similarly qualified person.

Operation

  • Do not operate this product if there is damage on the housing, lenses, or cables. Have the damaged parts replaced by an authorized technician at once.
  • Do not cover the ventilation slots when operating to avoid internal overheating.
  • The startup temperature range is -4 °F to 113 °F (-20 °C to 45 °C).
  • The operating temperature range is -40 °F to 113 °F (-40 °C to 45 °C).
  • The storage temperature range is -40 °F to 167 °F (-40 °C to 75 °C).
  • Do not start, operate, or store the product outside of the above temperature ranges.
  • In the event of a serious operation problem, stop using this product immediately!

If your Chauvet product requires service, contact Chauvet Technical Support.
Expected LED Lifespan
Over time, use and heat will gradually reduce LED brightness. Clustered LEDs produce more heat than single LEDs, contributing to shorter lifespans if always used at full intensity. The average LED lifespan is 40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit the overall intensity.

Introduction

Description
The Ilumipanel ML from Iluminarc is a large-format LED architectural unit. Perfect for washing the sides of buildings in bold, beautiful colors, it includes a range of easy-to-install beam spread filters to fit any size application. Installation is fast and simple, while the sleek chassis blends into the environment. Precision optics eliminate multicolored shadows, and the RGBL four-in-one LEDs output clean, true whites and a nearly unlimited palette of striking colors.

Product Overview

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel -
Introduction

Product Dimensions

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel - Introduction
2

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel - Introduction
3

Setup

AC Power
The Ilumipanel ML has an auto-ranging power supply, and it can work with an input voltage range of 100 to 277 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.

  • Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • Use only proprietary IP67 waterproof cables and secure unused ports with attached IP67 covers.

**** Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug
The Ilumipanel ML comes with a bare-ended power input cord. Use the table below to wire a plug.

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow or Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green

DMX Linking
The Ilumipanel ML will work with a DMX controller using a standard DMX serial connection. A DMX Primer is available from www.iluminarc.com.

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel -
Setup

Remote Device Management (RDM)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers have this capability. The Ilumipanel ML supports RDM protocol that allows feedback to make changes to menu map options.

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel - Setup
2

Beam-Shaping Filters
The Ilumipanel ML can be used with the medium, wide, very wide, or asymmetrical beam-shaping filters (sold separately).

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel - Setup
3

Follow the instructions below to install the optional filters:

  1. Detach the filter retainer lid by removing the screws attaching it to the fixture.
  2. Place the beam-shaping filter on top of the lenses.
  3. Place back the filter retainer lid on top of the beam-shaping filter.
  4. Screw the filter and the retainer lid back in place.

Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.

Orientation
Always mount this product in a safe position, making sure there is adequate room for ventilation, configuration, and maintenance.

Rigging
Chauvet recommends using the following general guidelines when mounting this product.

  • Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
  • Make sure that the structure onto which you are mounting the product can support the product’s weight (see the Technical Specifications for weight information).
  • When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, whether an elevated platform or a truss.
  • When rigging the product onto a truss, use hardware of appropriate weight capacity.

Procedure
The Ilumipanel ML comes with two adjustable brackets that can be secured directly to a mounting surface.
Make sure the mounting surface and hardware are capable of supporting the weight of this product. Use at least one mounting point per product.
Mounting Diagram

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel - Setup
4

Operation

RDM2go Control
The Ilumipanel ML requires an external controller, such as the RDM2go (from Chauvet Professional), to change its configuration.

Menu Map
Refer to the Ilumipanel ML product page on www.iluminarc.com for the latest menu map.
The Ilumicode section of the RDM2go (from Chauvet Professional) is required to access the full menu of options. For more information, download the RDM2go User Manual from www.chauvetprofessional.com.

Main Level Programming Levels Description
STATIC RED GREEN
BLUE COOL SOLID STROBE 000-255 Configures the static color and effect
DIMMER OFF Dimmer works in linear mode
DIM1-4 Dimmer works in non-linear mode, from fastest (DIM1) to slowest (DIM4)
CALIB WHITE
(1-11) RED GREEN BLUE COOL 000-255

color macros
RGBTOW| Determines the white balance when RGBTOW is active
PERSON| ARC1| 3-channel: RGB control
ARC1+D| 4-channel: dimmer, RGB control
ARC2| 4-channel: RGBL control
ARC2+D| 5-channel: dimmer, RGBL control
ARC FULL| 8-channel: dimmer, RGB control, preset colors, color temperature, strobe, dimmer speed
SOLID| 1-channel: LED control
SPECIALI| 15-channel: dimmer, strobe, dimmer speed, RGBL1, RGBL2, RGBL3
SPECIAL2| 9-channel: dimmer, RGBL control, preset colors, color temperature, strobe, dimmer speed
DMX| 001-512| Selects DMX address
(highest channel restricted to personality chosen)
UC-CALIB| RED GREEN BLUE| 000-255| Universal color calibration
SETTINGS| COLOR| OFF| Maximum output, unbalanced white
RGBTOW| White output is determined by the CALIB > RGBTOW settings
UC| Output matches that of product’s previous versions
RESET| NO| Resets unit to factory default settings
Y ES

Configuration (DMX)
Use control configurations to operate the product with a DMX controller.

Control Personalities
To set the control personality:

  1. Go to the PERSON main level.
  2. Select the desired personality, from ARC1, ARC1+D, ARC2, ARC2+D, ARC FULL, SOLID, SPECIAL1, or SPECIAL2.
    • See the Starting Address section for the highest starting address you can select for each personality.
    • Make sure that the starting addresses on the various products do not overlap due to the new personality setting.

Starting Address
Each product will respond to a unique starting address from the controller. All products with the same starting address will respond in unison. To set the starting address:

  1. Go to the DMX main level.
  2. Select the starting address (001–512).
Personality Channels Highest Starting Address
ARC1 3 510
ARC1+D 4 509
ARC2 4 509
ARC2+D 5 508
ARC FULL 8 505
SOLID 1 512
SPECIAL1 15 498
SPECIAL2 9 504

Control Channel Assignments and Values ARC1 (3 Channels)

Channel Function Value Percent/Setting
1 Red 000 ⇔ 255 0-100%
2 Green 000 ⇔ 255 0-100%
3 Blue 000 ⇔ 255 0-100%

ARC1+D (4 Channels)

Channel Function Value Percent/Setting
1 Dimmer 000 ⇔ 255 0-100%
2 Red 000 ⇔ 255 0-100%
3 Green 000 ⇔ 255 0-100%
4 Blue 000 ⇔ 255 0-100%

ARC2 (4 Channels)

Channel Function Value Percent/Setting
1 Red 000 ⇔ 255 0-100%
2 Green 000 ⇔ 255 0-100%
3 Blue 000 ⇔ 255 0-100%
4 Lime 000 ⇔ 255 0-100%

ARC2+D (5 Channels)

Channel Function Value Percent/Setting
1 Dimmer 000 ⇔ 255 0-100%
2 Red 000 ⇔ 255 0-100%
3 Green 000 ⇔ 255 0-100%
4 Blue 000 ⇔ 255 0-100%
5 Lime 000 ⇔ 255 0-100%

ARC FULL (8 Channels)

Channel Function Value Percent/Setting
1 Dimmer 000 ⇔ 255 0-100%
2 Red 000 ⇔ 255 0-100%
3 Green 000 ⇔ 255 0-100%
4 Blue 000 ⇔ 255 0-100%
5 Preset color 000 ⇔ 255 see Preset Colors Chart
6 Color temperature 000 ⇔ 255 see Color Temperature Chart
7 Strobe 000 ⇔ 009
010 ⇔ 255 No function Strobe, 1-25 Hz
8 Dimmer speed 000 ⇔ 009 010 ⇔ 029 030 ⇔ 069 070 ⇔ 129 130 ⇔ 189 190 ⇔ 255

No function
Dimmer speed OFF Dimmer speed 1 (fastest)
Dimmer speed 2 Dimmer speed 3 Dimmer speed 4 (slowest)

SOLID (1 Channel)

Channel Function Value Percent/Setting
1 Dimmer 000 ⇔ 255 All LEDs (0–100%)

SPECIAL1 (15 Channels)

Channel Function Value Percent/ Setting
1 Dimmer 000 ⇔ 255 0-100%
2 Strobe 000 ⇔ 009
010 ⇔ 255 No function Strobe, 1-25 Hz
3 Dimmer speed 000 ⇔ 009 010 ⇔ 029 030 ⇔ 069 070 ⇔129 130 ⇔ 189 190 ⇔ 255

No function
Dimmer speed OFF
Dimmer speed 1 (fastest)
Dimmer speed 2
Dimmer speed 3
Dimmer speed 4 (slowest)
4| Red (Group 1)| 000 ⇔ 255| 0-100%
5| Green (Group 1)| 000 ⇔ 255| 0-100%
6| Blue (Group 1)| 000 ⇔ 255| 0-100%
7| Lime (Group 1)| 000 ⇔ 255| 0-100%
8| Red (Group 2)| 000 ⇔ 255| 0-100%
9| Green (Group 2)| 000 ⇔ 255| 0-100%
10| Blue (Group 2)| 000 ⇔ 255| 0-100%
11| Lime (Group 2)| 000 ⇔ 255| 0-100%
12| Red (Group 3)| 000 ⇔ 255| 0-100%
13| Green (Group 3)| 000 ⇔ 255| 0-100%
14| Blue (Group 3)| 000 ⇔ 255| 0-100%
15| Lime (Group 3)| 000 ⇔ 255| 0-100%

SPECIAL2 (9 Channels)

Channel Function Value Percent/Setting
1 Dimmer 000 ⇔ 255 0-100%
2 Red 000 ⇔ 255 0-100%
3 Green 000 ⇔ 255 0-100%
4 Blue 000 ⇔ 255 0-100%
5 Lime 000 ⇔ 255 0-100%
6 Preset color 000 ⇔ 255 see Preset Colors Chart
7 Color temperature 000 ⇔ 255 see Color Temperature Chart
8 Strobe 000 ⇔ 009 No function
9 Dimmer speed 000 ⇔ 009

010 ⇔ 029
030 ⇔ 069
070 ⇔ 129
130 ⇔ 189
190 ⇔ 255| No function
Dimmer speed OFF
Dimmer speed 1 (fastest)
Dimmer speed 2
Dimmer speed 3
Dimmer speed 4 (slowest)

Preset Colors Chart

DMX Channel Preset Color DMX Channel Preset Color

000 ⇔ 010
011 ⇔ 020
021 ⇔ 025
026 ⇔ 030
031 ⇔ 045
046 ⇔ 050
051 ⇔ 060
061 ⇔ 065
066 ⇔ 070
071 ⇔ 080
081 ⇔ 085
086 ⇔ 110
111⇔ 120| No function
Light Salmon
Scarlet
Flame Red
Dark Salmon
Sunset Red
CID (to Tungsten)
Soft Golden Amber
Urban Sodium
LEE Yellow
Ice And A Slice
Dark Yellow Green
Turquoise| 121 ⇔ 140
141 ⇔ 145
146 ⇔ 150
151 ⇔ 160
161 ⇔165
166 ⇔185
186 ⇔ 200
201 ⇔ 205
206 ⇔ 220
221 ⇔ 225
226 ⇔ 240
241 ⇔ 255| Steel Green
Steel Blue
Special Steel Blue
New Color Blue
Dark Steel Blue
Pale Violet
Pretty ‘n Pink
Follies Pink
Smokey Pink
Flesh Pink
Pink
Cherry Rose

Color Temperature Chart

DMX Channel Preset Color DMX Channel Preset Color

000 ⇔ 009
010
010 ⇔ 025
025
025 ⇔ 040
040
040 ⇔ 055
055
055 ⇔ 070
070
070 ⇔ 085
085
085 ⇔ 100
100| No function
1800K
1800–2200K linear transition
2200K
2200–2700K linear transition
2700K
2700–3000K linear transition
3000K
3000–3200K linear transition
3200K
3200–4000K linear transition
4000K
4000–4500K linear transition
4500K| 100 ⇔ 115
115
115 ⇔ 130
130
130 ⇔ 145
145
145 ⇔ 160
160
160 ⇔ 175
175
175 ⇔ 190
190
190 ⇔ 205
205 ⇔ 255| 4500–5000K linear transition
5000K
5000–5600K linear transition
5600K
5600–6000K linear transition
6000K
6000–6500K linear transition
6500K
6500–7000K linear transition
7000K
7000–8000K linear transition
8000K
8000–10000K linear transition
100000K

Configuration (Static Mode)
To set the Ilumipanel ML to operate in a static or strobing color without DMX:

  1. Go to the STATIC main level.

  2. Select the parameter to configure, from:
    • RED,
    • GREEN,
    • BLUE,
    • COOL (lime),
    • SOLID (no function), or
    • STROBE

  3. Set the selected parameter to the desired level, from 000–255.

  4. Repeat until the static mode is set as desired.

Configuration (Settings)
Dimmer Speed
To set the dimmer speed:

  1. Go to the DIMMER main level.
  2. Select the dimmer speed from OFF (linear dimmer), DIM1 (fastest), DIM2, DIM3, or DIM4 (slowest).

Color Calibration
There are 4 color calibration options for the Ilumipanel ML: OFF (maximum output/unbalanced white), RGBTOW (quad-color calibration), UC (“universal”, tri-color calibration to match legacy products), and the color macro WHITE 1–11 settings.
To select the color calibration mode:

  1. Go to the SETTINGS main level.
  2. Select the COLOR option.
  3. Select the calibration mode, from OFF, RGBTOW, or UC.

Color Macro White Balance
To adjust the color macro white balance:

  1. Go to the CALIB main level.
  2. Select the macro to adjust, from WHITE 1–11.
  3. Select the color level to adjust, from RED, GREEN, BLUE, or COOL (lime).
  4. Set the level of the selected color, from 000–255.
  5. Repeat until the white balances are set as desired.

RGBTOW Mode
To adjust the color calibration in RGBTOW mode:

  1. Go to the CALIB main level.
  2. Select the RGBTOW option.
  3. Select the color level to adjust, from RED, GREEN, BLUE, or COOL (lime).
  4. Set the level of the selected color, from 000–255.
  5. Repeat until the calibration is set as desired.

Universal Calibration
To adjust the color calibration in UC mode:

  1. Go to the UC-CALIB main level.
  2. Select the color level to adjust, from RED, GREEN, or BLUE.
  3. Set the level of the selected color, from 000–255.
  4. Repeat until the calibration is set as desired.

Factory Reset
To reset the product to factory default settings:

  1. Go to the SETTINGS main level.
  2. Select the RESET option.
  3. Select from NO (cancel) or YES (reset).

Maintenance

Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:

  1. Unplug the product from power.
  2. Wait until the product is at room temperature.
  3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
  4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
  5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
  6. Softly drag any dirt or grime to the outside of the transparent surface.
  7. Gently polish the transparent surfaces until they are free of haze and lint.

Always dry the transparent surfaces carefully after cleaning them.

Technical Specifications

Dimensions and Weight

ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel - Technical
Specifications

Returns

Send the product prepaid, in the original box, and with the original packing and accessories. Iluminarc will not issue call tags.
Call Iluminarc and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return.
To submit a service request online, go to www.chauvetprofessional.com /service-request.
Clearly label the package with an RMA number. Iluminarc will refuse any product returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Before sending the product, clearly write the following information on a piece of paper and place it inside the box:

  • Your name
  • Your address
  • Your phone number
  • RMA number
  • A brief description of the problem

Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double- boxing are recommended.
Iluminarc reserves the right to use its own discretion to repair or replace returned product(s).

Contact Us

General Information Technical Support

World Headquarters
Address: 5200 NW 108th Ave.
Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084| Voice: 844-393-7575
Fax: 954-756-8015
Email: support@iluminarc.com
Website: www.iluminarc.com
U.K.
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110| Email: UKtech@chauvetlighting.eu
Website: www.iluminarc.com
Benelux
Address: Stokstraat 18
9770 Kruishoutem
Belgium
Voice: +32 9 388 93 97| Email: BNLtech@chauvetlighting.eu
Website: www.iluminarc.com
France
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France
Voice: +33 1 78 85 33 59| Email: FRtech@chauvetlighting.fr
Website: www.iluminarc.com
Germany
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Germany
Voice: +49 421 62 60 20| Email: DEtech@chauvetlighting.de
Website: www.iluminarc.com
Mexico
Address: Av. de las Partidas 34 – 3B
(Entrance by Calle 2)
Zona Industrial Lerma
Lerma, Edo. de México, CP 52000
Voice: +52 728-690-2010| Email: servicio@chauvet.com.mx
Website: www.iluminarc.com

Visit the applicable website above to verify our contact information and instructions to request support.
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record.

Ilumipanel ML User Manual Rev. 1

Documents / Resources

| ILUMINARC ILUMIPANEL ML Outdoor Rated LED Panel [pdf] User Manual
ILUMIPANEL ML, ILUMIPANEL ML Outdoor Rated LED Panel, Outdoor Rated LED Panel, Rated LED Panel, LED Panel, Panel
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals