PHONAK Audéo L-R Fit Trial Wireless Hearing Aids User Guide
- June 12, 2024
- PHONAK
Table of Contents
- PHONAK Audéo L-R Fit Trial Wireless Hearing Aids
- Product Information
- Product Usage Instructions
- Preparing the charger
- Quick guide
- Parts of the hearing aid and charger
- External power supply
- Preparing the charger
- Charging the hearing aids
- Left and right hearing aid markings
- Putting on the hearing aid
- Removing the hearing aid
- Multi-function button
- On/Off
- Tap Control
- Connectivity overview
- Tracking your heart rate
- Roger™ overview
- Rebooting your hearing aid
- Care and maintenance
- Exchanging the earwax protection
- Service and warranty
- Warranty limitation
- Compliance information
- Troubleshooting
- Important safety information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PHONAK Audéo L-R Fit Trial Wireless Hearing Aids
Product Information
This user guide is for the following products:
- Wireless hearing aids
- Charging accessories
- Phonak Charger Ease
The user guide contains instructions for using the hearing aids and charging accessories. Instructions for activity and heart rate tracking functions can be found in the myPhonak User Guide.
The hearing aids described in this user guide have a built-in and non- removable rechargeable lithium-ion battery. Safety information regarding handling rechargeable hearing aids can be found in chapter 26 of the user guide.
Product Usage Instructions
Charging your hearing aids
Before using your hearing aid for the first time, it is recommended to charge it for 3 hours.
To charge your hearing aids:
- Place your hearing aid in the charger.
- The indicator light on the hearing aid will show the charging state of the battery until it is fully charged.
- When fully charged, the indicator light will be constantly on, showing a solid green light.
Left & right hearing aid markings
The hearing aids have markings to indicate left and right:
- A red marking indicates the right hearing aid.
- A blue marking indicates the left hearing aid.
Parts of the hearing aid and charger
The hearing aids and charger have the following parts:
- Possible earpieces: Open Dome, Vented Dome, Clear Cap Dome, Sensor cShell
- Multi-function button with built-in indicator light
- Anchor (optional)
- Speaker with sensors (without earpiece attached)
- Charger Case lid
- Cavity for earpieces
- Hearing aid charging slots with left/right indicators
- External power supply
- USB-C connection to external power supply
- USB cable (< 3 m)
- Power supply (Note: The power plug is not provided with this product)
Preparing the charger
To prepare the charger:
- Connect the larger end of the charging cable to the power supply.
- Connect the smaller end of the charging cable to the USB port on the charger.
Please refer to the user guide for more detailed instructions on using the hearing aids, multi-function button, on/off functionality, tap control, connectivity overview, myPhonak app overview, heart rate tracking, pairing, phone calls, flight mode, rebooting, operating conditions, care and maintenance, earwax protection, service and warranty, compliance information, symbols, troubleshooting, and important safety information.
This user guide is valid for:
Wireless hearing aids Charging accessories Phonak Audéo L90-R Fit Phonak Audéo
L70-R Fit Phonak Audéo L-R Fit Trial Phonak Charger Ease
Note that instructions for the activity and heart rate tracking functions can
be found in the myPhonak User Guide.
Your hearing aid and charger details
- If no box is checked and you do not know the model of your hearing aid or charging accessories, please ask your hearing care professional.
- The hearing aids described in this user guide contain a built-in and non-removable rechargeable lithium-ion battery.
- Please also read safety information regarding handling rechargeable hearing aids (chapter 26).
Hearing aid models
- Audéo L R-Fit (L90/L70)
- Audéo L R-Fit Trial
Earpieces
- Open Dome
- Vented Dome Clear
- Cap Dome
- Sensor cShell
Charging accessories
Phonak Charger Ease incl. USB cable (< 3 m)
Only these domes can be used with Audéo Fit. The smoke colored Vented Dome should not be used.
Your hearing aids and chargers have been developed by Phonak – a world leader
in hearing solutions based in Zurich, Switzerland.
These premium products are the result of decades of research and expertise and
are designed with your well-being in mind. We thank you for making such a
great choice and wish you many years of listening pleasure.
Please read the user guide carefully to make sure that you understand and get
the best out of your device. Training is not required for handling of this
device. A hearing care professional will help set up this device according to
your individual preferences during the fitting consultation. For more
information regarding features, benefits, set up, use, maintenance or repairs
of your hearing aid and accessories, please contact your hearing care
professional or the manufacturer representative. Additional information can be
found in the datasheet of your product.
Phonak – life is on www.phonak.com
Quick guide
Charging your hearing aids
Before using your hearing aid for the first time, it is recommended to charge it for 3 hours.
After placing your hearing aid in the charger, the indicator light on the hearing aid will show the charging state of the battery until it is fully charged. When fully charged the indicator light will be constantly on, i.e. solid green light.
Left & right hearing aid markings
- Red marking for right hearing aid.
- Blue marking for left hearing aid.
Multi-function button with indicator light
- The button has several functions, the primary function is as an on/off switch.
- Together with your hearing care professional, you can decide if it also allows for volume control and/or program change.
- This is indicated in your individual instructions.
- Phone calls: If paired with a Bluetooth® enabled phone, a short press will accept and a long press will reject an incoming call.
- On/Off: Firmly press the lower part of the button for 3 seconds until the indicator light blinks.
- On: indicator light is solid green
- Off: indicator light is solid red
- Enter flight mode: When device is off, press the lower part of the button for 7 seconds until the solid orange light appears. Then release the button.
Tap Control
If paired with a Bluetooth® enabled device, multiple functions can be accessed
using Tap Control, please refer to chapter 10. This is also indicated in your
individual instructions.
To use Tap Control tap the top of your ear twice.
Parts of the hearing aid and charger
The following pictures show the hearing aid model and charger accessories described in this user guide. You can identify your personal models by:
- checking “Your hearing aid and charger details” on page 3.
- comparing your earpieces, hearing aid and charger with the following models..
Possible earpieces
Phonak Charger Ease
External power supply
The power plug is not provided with this product.
Preparing the charger
Connecting the power supply
The Phonak Charger Ease may be used with an external power supply that fulfills the specifications in the table below
- Plug the larger end of the charging cable into the power supply.
- Plug the smaller end into the USB port on the charger.
- Plug the power supply into a power outlet.
- The indicator light around the USB port will light up green when the charger is connected to the power outlet.
Power supply and charger Specifications
- Power supply input voltage 100-240 VAC, 50/60 Hz, current 0.25 A
- Power supply output voltage 5 VDC +/-5%, current 1 A
- Charger input voltage 5 VDC +/-5%, current 250 mA
- USB cable specifications 5 V min. 1 A, USB-A to USB-C, maximum length 3 m
Charging the hearing aids
- Low power: You will hear two beeps when the hearing aid battery is low. You will have approximately 60 minutes before you have to charge the hearing aids, after this time the hearing aid automatically shuts down (this can vary, depending on the hearing aid settings).
- The hearing aid contains a built-in and nonremovable rechargeable lithium-ion battery.
- Before using your hearing aid for the first time, it is recommended to charge it for 3 hours.
- The hearing aid must be dry before charging, see chapter 19.
- Please ensure to charge the hearing aid within operating temperature range: Audéo L R-Fit: +5° to +40° Celsius (41° to 104° Fahrenheit)
Using the Phonak Charger Ease
Please refer to chapter 3 for how to set up the charger.
-
Insert the hearing aid into the charging slots and the earpieces in the large cavity. Make sure the left and right hearing aid markings match the left (blue), right (red) indicators next to the charging slots. The hearing aids will automatically switch off once inserted into the charger
-
The indicator light on the hearing aid will show the charging state of the battery until the hearing aid is fully charged. When fully charged the indicator light will remain on, i.e. solid green light.
-
The charging process will automatically stop when the batteries are fully charged, so the hearing aids can be safely left in the charger. It can take up to 3 hours to charge the hearing aids. The charger lid can be closed while charging.
Charging times -
Remove the hearing aids from the charging slots by simply lifting them out of the charger.
The hearing aid can be set to switch on automatically when removed from the charger. The indicator light starts blinking. The solid green light indicates the hearing aid is ready for use.
If you unplug the charger while the hearing aid is charging inside, please make sure to turn off the hearing aid to prevent discharge. To switch off the charger, remove the power supply from the power outlet.
Turn off your hearing aid before inserting it in the disconnected charger to store it.
Do not hold the tubes to remove the hearing aids from the charger as this can damage the tubes
Left and right hearing aid markings
There is a red or blue marking on the back of the hearing aid and on the speaker. This will tell you if it is a left or a right hearing aid.
Blue marking for left hearing aid.
Red marking for right hearing aid.
Putting on the hearing aid
- Place the hearing aid behind your ear.
- Insert the earpiece into your ear canal.
- If there is an anchor attached to the earpiece, tuck it into the bowl of your ear to secure your hearing aid.
Removing the hearing aid
Pull on the bend of the tube and remove the hearing aid from behind the ear.
Multi-function button
The button has several functions, the primary function is as an on/off switch.
Together with your hearing care professional, you can decide if it also allows
for volume control and/or program change.
This is indicated in your individual “Hearing aid instructions”. Please ask
your hearing care professional for a printout.
If the hearing aid is paired with a Bluetooth® enabled phone, a short press on
the upper or the lower part of the button will accept an incoming call and a
long press will reject an incoming call – refer to chapter 16.
On/Off
Switch on hearing aid
The hearing aid is configured to switch on automatically when removed from the
charger. If this function is not configured, firmly press and hold the lower
part of the button for 3 seconds until the indicator light blinks. Wait until
the solid green light indicates the hearing aid is ready.
Switch off hearing aid
Press and hold the lower part of button for 3 seconds until the solid red
light indicates the hearing aid is switching off.
When you switch on the hearing aid you might hear a start-up melody
Tap Control
If paired with a Bluetooth® enabled device, multiple functions can be accessed using Tap Control e.g. accept/end phone call, pause/resume streaming, start/stop voice assistant. This is indicated in your individual “Hearing aid instructions”. To use Tap Control tap the top of your ear twice.
Connectivity overview
The illustration below shows the connectivity options available for your hearing aid.
- The TV Connector can be connected to any audio source such as a TV, PC or hi-fi system.
- Roger wireless microphones can be connected to your hearing aids as well
myPhonak app overview
Please find the Instruction for Use on https://www.phonak.com/en-
int/hearingdevices/apps/myphonak or scan the code
Install the myPhonak app
Tracking your heart rate
Note that instructions for the heart rate tracking function can be found in
the myPhonak app User Guide.
To track your heart rate, make sure your ear pieces are correctly inserted
into the ear canal. See page 18 chapter 6. For the best result, keep still and
quiet.
The information contained in the myPhonak app health section is for
educational and informational purposes only. You should not use the
information shown in the health section as a substitute for, nor should it
replace, professional medical advice. If you have any questions about your
health, or before beginning an exercise program, you should always consult
with a physician or other health care professional
Roger™ overview
Experience the hearing performance of Roger™
Roger™ is designed to improve hearing in situations with background noise or
distance to the speaker. The microphone picks up the voice of the speaker and
wirelessly transmits it directly to Roger receivers* in your hearing aids.
This enables you to fully participate in group conversations even in very
noisy environments such as restaurants, meetings at work and school activities
To learn more about the Roger technology and microphones, please visit the
webpage https://www.phonak.com/roger-solutions or scan the QR code
RogerDirect™ requires the installation of Roger receivers into the Phonak hearing aids by a hearing care professional
Initial pairing
Initial pairing to a Bluetooth® enabled device
It is only necessary to perform the pairing procedure once with each device
featuring Bluetooth wireless technology. After the initial pairing, your
hearing aids will connect automatically to the device. Initial pairing can
take up to 2 minutes.
- On your device (e.g. a phone), ensure that Bluetooth® wireless technology is enabled and search for Bluetooth® enabled devices in the connectivity setting menu.
- Switch on both hearing aids. You now have 3 minutes to pair your hearing aids with your device.
- Your device shows a list of Bluetooth® enabled devices. Select the hearing aid from the list to simultaneously pair both hearing aids. A beep confirms successful pairing
For more information about pairing instructions for Bluetooth wireless technology, specific to some of the most popular phone manufacturers, go to: https://www.phonak.com/en-int/support
Connecting to the device
After your hearing aids have been paired to your device, they will automatically connect again when switched on.
- The connection will be maintained as long as the device remains ON and within range.
- Your hearing aid can be connected to up to two devices and paired to up to eight devices.
Phone calls
Your hearing aids connect directly with Bluetooth® enabled phones. When paired and connected to your phone, you will hear notifications, incoming call notification and the caller’s voice directly in your hearing aids. Phone calls are “hands free”, this means your voice is picked up by the hearing aid’s microphones and transmitted back to the phone.
Making a call
Enter the phone number and press the dial button. You will hear the dialing
tone through your hearing aids. Your voice is picked up by the hearing aid
microphones and transmitted to the phone.
Accepting a call
When receiving a call, an incoming-call notification will be heard in the
hearing aids (e.g. ring tone or voice notification).
The call can be accepted by tapping the top of your ear twice, a short press
on the upper or lower part of the multi-function button on the hearing aid
(less than 2 seconds) or directly on your phone.
Ending a call
A call can be ended by a long press on the upper or lower part of the multi-
function button on the hearing aid (more than 2 seconds) or directly on your
phone. The phone call can also be ended by tapping the top of your ear twice
.
Rejecting a call
An incoming call can be rejected by a long press on the upper or lower part of
the multi-function button on the hearing aid (more than 2 seconds) or directly
on your phone.
Flight mode
Your hearing aids operate between 2.4 GHz–2.48 GHz frequency range. When
flying some operators require all devices to be switched into flight mode.
Entering flight mode will not disable normal hearing aid functionality, only
the Bluetooth connectivity functions.
Enter flight mode
To disable the wireless function and enter flight mode in each hearing aid
:
In flight mode, your hearing aid cannot connect directly to your phone.
Exit flight mode
To enable the wireless function and exit flight mode in each hearing aid:
Switch the hearing aid off and then on again – refer to chapter 9.
Rebooting your hearing aid
Use this technique if your hearing aid is in an error state. This will not remove or delete any program or settings.
- Press the lower part of the multi-function button for at least 15 seconds. It does not matter if the hearing aid is switched on or off before you start pressing the button. There is no light or acoustic notification at the end of the 15 seconds.
- Place the hearing aid in the power-connected charger and wait until the indicator light blinks green. This can take up to 30 seconds. The hearing aid is now ready to use.
Operating, transport and storage conditions
The product is designed such that it functions without problems or restrictions if used as intended, unless otherwise noted in these user guides. Please ensure to use, charge, transport and store the hearing aids and the charger according to the following conditions
Audéo L R-Fit and Charger
- These hearing aids are classified as IP68. This means that they are water and dust resistant and designed to withstand daily life situations. They can be worn in the rain but should not be fully submerged in water or used when taking a shower, swimming or other water activities. These hearing aids should never be exposed to chlorinated water, soap, salt water or other liquids with a chemical content.
- This charger is classified as IP21. This means that the charger is protected from vertically falling drops of water e.g. condensation.
- Please ensure to charge the hearing aids regularly during long-term storage.
- If the device has been subject to storage and transport conditions outside of the recommended use conditions, wait 15 minutes before starting the device.
Care and maintenance
Expected Service Life:
The hearing aids and the compatible charger have the expected service life of five years. The devices are expected to remain safe for use for this duration.
Commercial service period:
Routine and diligent care of your hearing aids and charger will contribute to
the outstanding performance for the duration of the expected service life of
your devices. Sonova AG will provide a minimum of a five year repair service
period after the respective hearing aid, charger and essential components have
been phased out of the product portfolio.
Please use the following specifications as a guideline. For further
information regarding product safety, see chapter 26.2.
General information
Before using hair spray or applying cosmetics, you should remove your hearing
aid from your ear, because these products may damage it.
Your hearing aids are resistant to water, sweat and dust under the following
conditions:
- After exposure to water, sweat or dust, the hearing aid is cleaned and dried.
- The hearing aid is used and maintained as described in this user guide.
Always make sure that the hearing aids and charger are dry and clean.
Daily
-
Hearing aid: Inspect the earpiece for earwax and moisture deposit and clean the surfaces with a lint-free cloth. Never use cleaning agents such as household detergents, soap, etc. for cleaning your hearing aid. It is not recommended to rinse with water. If you need to clean your hearing aid intensively, ask your hearing care professional for advice and information on filters or drying methods.
-
Charger: Make sure that charger inserts are clean and clean the surfaces with a lint-free cloth.
Never use cleaning agents such as household detergents, soap, etc. for cleaning your charger.
Weekly -
Hearing aid: Clean the earpiece with a soft, damp cloth or with a special cleaning cloth for hearing aids. For more in-depth maintenance instructions, please see your hearing care professional. Clean the charging contacts on the hearing aid with a soft, damp cloth.
-
Chargers: Remove dust or dirt from the charger inserts with a lint-free cloth.
Always make sure that the charger is disconnected from the power mains before cleaning.
Exchanging the earwax protection
Your hearing aid is equipped with an earwax protection to protect the speaker
from earwax damage.
Please check the earwax protector regularly and exchange it if it looks dirty
or if the hearing aid volume or sound quality is reduced. The earwax
protection should be replaced every four to eight weeks on a regular receiver.
Removing the earpiece from the speaker
Remove the earpiece from the speaker by holding the speaker in one hand and
the earpiece in the other.
Gently pull off the earpiece to remove.
Clean the speaker with a lint-free cloth.
Exchanging the earwax protection with CeruShield™ Disk
- Gently rotate the CeruShield Disk in the direction indicated by the arrows until a free opening appears under the bin icon.
- To remove a used earwax protector carefully insert the speaker into the free opening (under bin icon) until it clicks. The used earwax protector will remain in the disk when you lift the speaker away.
- Carefully insert the speaker into the opening where the new earwax protector is visible
(opposite the bin icon) until it clicks. Lift the speaker away from the disk, the new earwax protector is now positioned inside the speaker.
Attaching the earpiece to the speaker
- Hold the speaker in one hand and the earpiece in the other.
- Slide the earpiece over the speaker sound outlet.
- The speaker and the earpiece should fit perfectly together.
Service and warranty
Local warranty
Please ask the hearing care professional where you purchased your hearing aids
and charger about the terms of the local warranty.
International warranty
Sonova AG offers a one year limited international warranty, valid from the
date of purchase. This limited warranty covers manufacturing and material
defects in the hearing aid and charger respectively, but not accessories such
as tubes, earpieces, external receivers. The warranty only comes into force if
a proof of purchase is shown.
The international warranty does not affect any legal rights that you might
have under applicable national legislation governing sale of consumer goods.
Warranty limitation
This warranty does not cover damage from improper handling or care, exposure to chemicals or undue stress. Damage caused by third parties or non-authorized service centers renders the warranty null and void. This warranty does not include any services performed by a hearing care professional in their office.
- Serial numbers
- Hearing aid left side:
- Hearing aid right side:
- Charger:
- Date of purchase:
- Authorized hearing care professional (stamp/signature):
Compliance information
Europe:
Declaration of Conformity for the hearing aid Hereby Sonova AG declares that
this product meets the requirements of the Medical Device Regulation (EU)
2017/745 as well as the Radio Equipment Directive 2014/53/EU. The full text of
the EU Declaration of Conformity can be obtained from the manufacturer or the
local Phonak representative whose address can be taken from the list on
https://www.phonak.com/en-int/certificates
(Phonak worldwide locations).
Australia/New Zealand:
Indicates a device’s compliance with applicable Radio Spectrum Management’s
(RSM) and Australian Communications and Media Authority (ACMA) regulatory
arrangements for the legal sale in New Zealand and Australia.
The compliance label R-NZ is for radio products supplied in the New Zealand
market under conformity level A1.
The wireless models listed on page 2 are certified under:
Phonak Audéo L-R Fit (90/70)
Phonak Audéo L-R Fit Trial
- USA FCC ID: KWC-PRF
- Canada IC: 2262A-PRF
Notice 1:
This device complies with Part 15 of the FCC Rules and with RSS-210 of
Industry Canada. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Notice 2:
Changes or modifications made to this device not expressly approved by Sonova
AG may void the FCC authorization to operate this device.
Notice 3:
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of Industry
Canada. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This device generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the device and receiver.
- Connect the device into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radio information of your wireless hearing aid
- Antenna type Resonant loop antenna
- Operation frequency 2.4 GHz – 2.48 GHz
- Modulation GFSK, Pi/4 DPSK, GMSK
- Radiated power < 2.5 mW
- Bluetooth®
- Range ~1 m
- Bluetooth 4.2 Dual-Mode
- Profiles supported HFP (Hands-free profile), A2DP
Electromagnetic compatibility (EMC)
Phonak hearing aids and charging accessories are EMC-tested in conformity with the requirements of IEC 60601-1-2:2014 or IEC 60601-1-2:2014 A1 2020.
Information and description of symbols
- With the CE symbol, Sonova AG confirms that this product – including accessories – meets the requirements of the Medical Devices Regulation (EU) 2017/745 as well as the Radio Equipment Directive 2014/53/EU.
- The numbers after the CE symbol correspond to the code of certified institutions that were consulted under the above-mentioned regulation and directive.
- This symbol indicates that the products described in these user instructions adhere to the requirements for an applied part of Type B of EN 60601-1. The surface of the hearing aid is specified as an applied part of Type B. Indicates the medical device manufacturer, as defined in Medical Device Regulation (EU) 2017/745
- Indicates the date when the medical device was manufactured
- Indicates the Authorized representative in the European Community. The EC REP is also the importer to the European Union.
- This symbol indicates that it is important for the user to read and take into account the relevant information in these user guides.
- This symbol indicates that it is important for the user to pay attention to the relevant warning notices in these user guides.
- This symbol indicates that it is important for the user to pay attention to the relevant warning notices related to batteries in these user guides
- Important information for handling and product safety.
- This symbol confers that the electromagnetic interference from the device is under limits approved by the US Federal Communications Commission.
- Indicates a device’s compliance with applicable Radio Spectrum Management’s (RSM) and Australian Communications and Media Authority (ACMA) regulatory arrangements for the legal sale in New Zealand and Australia
- The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by
- Sonova AG is under license. Other trademarks and trade names are those of their respective owners.
- Japanese mark for certified radio equipment.
- Indicates the manufacturer’s serial number so that a specific medical device can be identified.
- Indicates the manufacturer’s catalogue number so that the medical device can be identified. Indicates that the device is a medical device.
- This symbol indicates that it is important for the user to read and take into account the relevant information in this user guide. Ingress Protection Rating. IP68 rating indicates that the hearing aid is water and dust resistant. It survived continuous immersion in 1 meter of fresh water for 60 minutes and 8 hours in a dust chamber as per the IEC60529 standard
- IP Rating = Ingress Protection Rating. IP21 rating indicates that the device is protected against solid foreign objects of 12,5 mm and greater. Protected against vertically falling water drops.
- Temperature during transportation and storage: –20° to +60° Celsius (–4° to +140° Fahrenheit).
- Humidity during transportation and storage: 0% to 70%, if not in use. See instruction in chapter 25.2 regarding drying the hearing aid after use.
- Atmospheric pressure during operation transportation and storage: 500 hPa to 1060 hPa During transportation keep dry.
- The symbol with the crossed-out garbage bin is to make you aware that this hearing aid as well as the charger may not be thrown away as normal household waste. Please dispose of old or unused hearing aids and charger, at waste disposal sites intended for electronic waste, or give your hearing aid and charger to your hearing care professional for disposal. Proper disposal protects the environment and health
Symbols applicable to the European power supply only
- Power supply with double isolation.
- Device designed for indoor use only.
- Safety isolating transformer, short circuit proof
Troubleshooting
- Problem Causes Hearing aid not functioning
- Speaker/earpiece blocked Hearing aid switched off Battery fully discharged Hearing aid whistles Hearing aid not inserted correctly into ear Cerumen in ear canal Hearing aid too loud Volume too loud Hearing aid not loud enough or distorted
- Volume too low Low battery Speaker/earpiece blocked Hearing has changed Hearing aid plays two beeps
- Indication for low battery Hearing aid will not switch on
- Battery fully discharged Button was inadvertently deactivated by pressing the button longer than 15 seconds
- Indicator light on hearing aid does not light up when hearing aid placed in charging slots
- Hearing aid not inserted correctly into charger
- Hearing aid battery fully discharged
What to do
- Clean speaker opening/earpiece
- Press lower part of multi-function button for 3 seconds (chapter 9)
- Charge hearing aid (chapter 4)
- Insert hearing aid correctly (chapter 6)
- Contact your ENT/GP or hearing care professional
- Decrease volume if volume control available (chapter 8)
- Increase volume if volume control available (chapter 8)
- Charge hearing aid (chapter 4)
- Clean speaker opening/earpiece
- Contact your hearing care professional
- Charge hearing aid (chapter 4)
- Charge hearing aid (chapter 4)
- Perform step 2 of the rebooting process (chapter 18)
- Insert hearing aid correctly into charger (chapter 4)
- Wait three hours after placing hearing aid in charger, regardless of LED behavior
Please check https://www.phonak.com/en-int/support.html for further information.
What to do
- Warm hearing aid up or cool it down. Operating temperature range is +5° to +40° Celsius (+41° to +104° Fahrenheit)
- Contact your hearing care professional
- Switch on the hearing aid (chapter 9)
- Reboot the hearing aid (chapter 18)
- Contact your hearing care professional. A battery replacement may be required
- Switch hearing aid off and then on again (chapter 17.2)
- Pair hearing aid to the phone (chapter 15)
- Insert hearing aid correctly into charger (chapter 4.1)
If the problem persists, contact your hearing care professional for assistance.
Important safety information
Please read the relevant safety information and limitationsof- use information on the following pages before using your hearing aid.
Intended use
- The hearing aid is intended to amplify and transmit sound to the ear and thereby compensate for impaired hearing.
- The Tinnitus software feature is intended for use by people with tinnitus who also desire amplification. It provides supplementary noise stimulation which can help defocus the user`s attention from their tinnitus.
- The chargers are intended to charge the battery of the rechargeable hearing aid.
Intended patient population:
- Hearing aids: This device is intended for patients with unilateral and bilateral, mild to severe hearing loss from 8 years of age. The Tinnitus software feature is intended for patients with chronic tinnitus from 18 years of age.
- Charger: The intended patient population is the user of the compatible hearing aids
Intended user:
Hearing aids: Intended for people with hearing loss using a hearing aid and
their caregivers. A hearing care professional is responsible for adjusting the
hearing aid. Charger: Intended for people with hearing loss using the
compatible rechargeable hearing aid their caregivers and hearing care
professional
Indications:
Clinical indications for the use of hearing aids and Tinnitus software feature
are:
Presence of hearing loss
- Uni- or bilateral
- Conductive, sensorineural or mixed
- Mild to severe
Presence of a chronic tinnitus (> 3 months, after occurrence) in addition to
the presence of a hearing loss (only applicable for devices which provide the
Tinnitus feature).
Charger: Please note, indications are not derived from the charger, but from
the compatible hearing aids
Contraindications:
Clinical contra-indications for the use of hearing aids and Tinnitus software
feature are:
-
* Hearing loss is not in the fitting range of the hearing aid (i.e. gain, frequency response)
-
Acute tinnitus (< three months after it occurs)
-
Deformity of the ear (i.e. closed ear canal; absence of the auricle)
-
Neural hearing loss ( i.e. retro-cochlear pathologies such as absent / non-viable auditory nerve)
Charger: Please note, contraindications are not derived from the charger, but from the compatible hearing aids. The primary criteria for the referral of a patient for a medical or other specialist opinion and / or treatment are as follows: -
Visible congenital or traumatic deformity of the ear;
-
History of active drainage from the ear in the previous 90 days;
-
History of sudden or rapidly progressive hearing loss in one or both ears within the previous 90 days;
-
Acute or chronic dizziness;
-
Audiometric air-bone gap equal to or greater than 15 dB at 500 Hz, 1000 Hz and 2000 Hz;
-
Visible evidence of significant cerumen accumulation or a foreign body in the ear canal;
-
Pain or discomfort in the ear;
-
Abnormal appearance of the eardrum and ear canal such as:
-
Inflammation of the external auditory canal
-
Perforated eardrum
-
Other abnormalities which the hearing care professional believes are of medical concern Special care should be exercised in selecting and fitting a hearing aid whose maximum sound pressure level exceeds 132 decibels (dB) because there may be risk of impairing the remaining hearing of the hearing aid user. (This provision is required only for those hearing aids with a maximum sound pressure capability greater than 132 dB).
The hearing care professional may decide that referral is not appropriate or in the best interests of the patient when the following applies:
- When there is sufficient evidence that the condition has been fully investigated by a medical specialist and any possible treatment has been provided;
- The condition has not worsened or changed significantly since the previous investigation and / or treatment.
- If the patient has given their informed and competent decision not to accept advice to seek a medical opinion, it is permissible to proceed to recommend appropriate hearing aid systems subject to the following considerations:
- The recommendation will not have any adverse effects on the patients health or general well being;
- The records confirm that all necessary considerations about the patient´s best interests have been made
If legally required, the patient has signed a disclaimer to confirm that the referral advice has not been accepted and that it is an informed decision.
Clinical benefit:
Hearing aid: Improvement of speech understanding Tinnitus feature: Tinnitus software feature provides supplementary noise stimulation which can help defocus the user`s attention from their tinnitus. Charger: The Charger itself does not provide a direct clinical benefit. An indirect clinical benefit is provided by enabling the parent device (rechargeable hearing aids) to achieve their intended purpose.
Side effects:
- Physiological side-effects of hearing aids like tinnitus, dizziness, wax build up, too much pressure, sweating or moisture, blisters, itching and/or rashes, plugged or fullness and their consequences like headache and/ or ear pain, may be resolved or reduced by your hearing care professional. Conventional hearing aids have the potential to expose patients to higher levels of sound exposure, which might result in threshold shifts in the frequency range affected by acoustic trauma.
- Charger: Please note, side effects are not derived from the charger, but from the compatible hearing aids.
- The hearing aid is suitable for the home healthcare environment and due to their portability it may happen that it is used in professional healthcare facility environment like physician offices, dental offices etc.
- A hearing aid will not restore normal hearing and will not prevent or improve a hearing impairment resulting from organic conditions. Infrequent use of a hearing aid does not permit a user to attain full benefit from it. The use of a hearing aid is only part of hearing habilitation and may need to be supplemented by auditory training and instruction in lipreading.
- Feedback, poor sound quality, too loud or too soft sounds, inadequate fitting or problems when chewing or swallowing, can be resolved or improved during the fine-tuning process at the fitting procedure by your hearing care professional.
- Any serious incident that has occurred in relation to the hearing aid, should be reported to the manufacturer representative and the competent authority of the state of residence. The serious incident is described as any incident that directly or indirectly led, might have led or might lead to any of the following:
- the death of a patient, user or other person
- the temporary or permanent serious deterioration of a patient’s, user’s or other person’s state of health
- a serious public health threat
- To report an unexpected operation or event, please contact the manufacturer or a representative.
Hazard warnings
- Your hearing aids operate between 2.4 GHz -2.48 GHz frequency range. When flying please check if flight operator requires devices to be switched into flight mode, see chapter 17.
- The hearing aids (specially programmed for each hearing loss) must only be used by the intended person. They should not be used by any other person as they could damage hearing.
- Changes or modifications to the hearing aid and the charger that were not explicitly approved by Sonova AG are not permitted. Such changes may damage your ear or the hearing aid
- Do not use the hearing aids and charging accessories in explosive areas (mines or industrial areas with danger of explosions, oxygen rich environments or areas where flammable anesthetics are handled) or where electronic equipment is prohibited. The device is not ATEX certified.
- If you feel pain in or behind your ear, if it is inflamed or if skin irritation and accelerated accumulations of earwax occur, please check with your hearing care professional or physician.
- In very rare cases, the dome can remain in your ear canal when removing the hearing tube from the ear. In the unlikely case that the dome does get stuck in your ear canal, it is strongly recommended to see a physician for safe removal.
- Hearing programs in the directional microphone mode reduce background noises. Please be aware that warning signals or noises coming from behind, e. g. cars, are partially or entirely suppressed.
- This hearing aid is not for children below 36 months. The usage of this device by children and individuals with cognitive impairment should be supervised at all times to ensure their safety. The hearing aid is a small device and contains small parts. Do not leave children and individuals with cognitive
- impairment unsupervised with this hearing aid. If swallowed, consult a physician or hospital immediately as the hearing aid or its parts can cause choking!
The following is only applicable for persons with active implantable medical devices (i.e. pacemakers, defibrillators, etc.):
- Keep the wireless hearing aid and the charging device at least 15 cm (6 inches) away from the active implant. If you experience any interference, do not use the wireless hearing aids and contact the manufacturer of the active implant. Please, note that interference can also be caused by power lines, electrostatic discharge, airport metal detectors etc.
- Keep magnets (i.e battery handling tool, EasyPhone magnet, etc.) at least 15 cm (6 inches) away from the active implant.
- Only authorized personnel are allowed to open the charging case due to possible electrical hazard.
- Do not touch the contacts of the charger when powered.
- Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
- Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
- Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the hearing aids and charger, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
- Hearing aids should not be fitted with domes / wax protection systems when used by clients with perforated eardrums, inflamed ear canals or otherwise exposed middle ear cavities. In these cases, we recommend the use of a custom earpiece. In the unlikely case that any part of this product should remain in the ear canal, it is strongly recommended to see a medical specialist for safe removal.
- Avoid strong physical impacts to the ear when wearing a hearing aid with customized earpiece. The stability of customized earpieces is designed for normal use. A strong physical impact to the ear (e.g. during sports) may cause the customized earpiece to break. This may lead to perforation of the ear canal or eardrum.
- After mechanical stress or shock to the customized earpiece, please ensure that it is intact before placing it in the ear.
- The majority of hearing aid users have a hearing loss for which a deterioration in hearing is not to be expected with regular use of a hearing aid in everyday situations. Only a small group of hearing aid wearers with hearing loss, may be at risk of deterioration in hearing after a long period of use.
- Do not remove receiver cables from the hearing instruments. If removal or exchange is required it is recommended to contact the hearing care professional.
- WARNING: The hearing aids use a lithium button/coin battery. These batteries are hazardous and can cause severe or fatal injuries in 2 hours or less if they are swallowed or placed inside any part of the body, whether the battery is used or new! Keep out of the reach of children, individuals with cognitive impairment, or pets. If you suspect that a battery was swallowed or placed inside any part of the body, immediately consult your physician without any delay!
- Your hearing aid(s) contain lithium-ion batteries with a Watt hour rating <20Wh which have been tested according to UN 38.3 of the “UN Manual of Tests and Criteria” and should be shipped in accordance with all the rules and regulations on the safe shipment of lithium-ion batteries.
- For charger, use only IEC 60950-1 *, IEC 62368-1 or IEC 60601-1 certified equipment with an output rating of 5 VDC. Min. 500 mA.
Note : this standard may not be valid anymore in your country, please refer to IEC 62368-1
- Cables and cords wrapped around the neck may cause strangulation. Do not leave the device and its components unattended with children, individuals with cognitive impairment or pets.
- The Patients implanted with magnetic externally programmable CSF shunt valves may have a risk of experiencing an unintended change in their valve setting when exposed to strong magnetic fields. The receiver (loudspeaker) of hearing aids, the Lyric SoundLync, the Lyric programming and the
- MiniControl contain static magnets. Keep distance of 2 inches (approx. 5 cm) or more between the magnets and the site of the implanted shunt valve.
- The hearing aids have to be dry before charging. Otherwise the charging reliability cannot be guaranteed.
Information on product safety
- Protect your hearing aid and charging accessories from heat and sunlight (never leave near a window or in the car). Never use a microwave or other heating devices to dry your hearing aid or charging accessories (due to risk of fire or explosion). Ask your hearing care professional about suitable drying methods.
- Do not place the hearing aids and charging accessories close to an induction cooking surface. Conductive structures inside the charging accessories could absorb inductive energy resulting in thermal destruction.
- The dome should be changed every three months or when it becomes stiff or brittle. This is to prevent the dome from detaching from the tube spout during insertion into or removal from the ear.
- Do not drop your hearing aid or charging accessories! Dropping onto a hard surface can damage your hearing aid or charging accessories.
- Charger and power supply must be protected against shocks. If the charger or power supply is damaged after a shock, the devices must not be used anymore.
- If you are not using your hearing aid for a long period of time, store it in a box with a drying capsule or in a well ventilated location. This allows moisture to evaporate from your hearing aid and prevents a potential impact on its performance.
- Special medical or dental examination including radiation described below, may adversely affect the correct functioning of your hearing aids. Remove and keep them outside the examination room/area before undergoing:
- Medical or dental examination with X-ray (also CT scan).
- Medical examinations with MRI/NMRI scans, generating magnetic fields. Hearing aids don’t need to be removed when passing security gates (airports etc.). If X-ray is used at all, it will be in very low doses, and will not affect the hearing aids.
- The hearing aids have to be dry before charging. Otherwise the charging reliability cannot be guaranteed.
- Only use approved charger described in this user guide for charging your hearing aids, otherwise the devices may be damaged.
- Make sure that you always completely dry your hearing aid after use. Store the hearing aid in a safe, dry and clean place.
- The hearing aids are water resistant and not waterproof. They are designed to withstand normal activities and occasional accidental exposure to extreme conditions. Never immerse your hearing aid in water! Phonak hearing aids are not specifically designed for extended periods of water submersion on a continual basis, that is worn in activities such as swimming or bathing. Always remove your hearing aid before these activities, as the hearing aid contains sensitive electronic parts. Never wash the microphone inputs. Doing so could cause it to lose its special acoustic features.
- Do not use your hearing aid or charger in areas where electronic equipment is prohibited.
Sonova Deutschland GmbH
Max-Eyth-Strasse 20 70736 Fellbach-Oeffingen Germany
Manufacturer : Sonova AG Laubisrütistrasse 28 CH-8712 Stäfa Switzerland
www.phonak.com
Australian Sponsor : Sonova Australia Pty Ltd 12 Inglewood Place, Norwest
NSW 2153 Australia
029-1277-02/V1.00/2023-02/PM © 2023 Sonova AG All rights reserved
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>