IDEAL 61-517 GFCI Receptacle-Voltage Tester
**Product Information
**
The IDEAL 61-517 GFCI Receptacle Tester is a 120V AC plug-in outlet tester. It is designed to indicate proper polarity or mis-wired outlets through Green and Red LEDs. Additionally, it has an LCD that displays line voltage. The tester also checks for GFCI functioning.
Safety Information
Warning – Identifies conditions and actions that could result in possible
death or serious injury if the hazard is realized.
Caution – Identifies conditions and actions that could result in meter
damage, equipment under test damage or data loss if the hazard is realized.
WARNING
Arc Flash and Shock Hazard, Proper PPE Required. Follow all safety procedures, wear proper PPE in accordance to NFPA 70E and follow the guidelines below and the instructions in this manual when operating the meter. Failure to comply can result in serious injury or death.
-
Choking Hazard, Small Parts. Keep Away from Children. Sharp Objects Hazard, This is not a toy. It is not for use or play by children. Keep Away from Children. Failure to do so can result in serious injury.
-
Only experienced or technically competent consumers should use this equipment. When in doubt, call an experienced electrician to make any and all necessary repairs or installations. At all times, perform any necessary work on a de-energized circuit that has had its circuit breaker turned off and has been locked out.
-
Use the Meter only as specified in this manual or protection provided by the Meter can be compromised.
-
Before using or connecting the Meter, visually inspect it
to ensure the cases are not cracked and the back case is securely in place. Do not use if the Meter appears damaged. -
This Meter is intended for use by qualified electricians. Follow NFPA 70E Standards for Electrical Safety in the Workplace when using this Meter.
-
Do not use without the batteries correctly in place and the battery door closed and secured.
-
Do not use Meter if it operates incorrectly as protection may be compromised. When in doubt, have the Meter serviced.
-
When servicing the Meter, use only specified replacement parts.
Arc Flash and Shock Hazard, Proper PPE Required. Follow all safety procedures, wear proper PPE in accordance to NFPA 70E and follow the guidelines below and the instructions in this manual when operating the meter. Failure to comply can result in serious injury or death.
- Have the Meter serviced only by qualified service personnel.
- Do not use the Meter around explosive gas, dust, or vapor, or during electrical storms, or in wet environments.
- Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and earth ground.
- To avoid false readings that can lead to electrical shock and injury, replace the batteries as soon as the low battery indicator ( ) appears.
- Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution.
- Do not work alone so that assistance can be rendered in an emergency.
- Use extreme caution when working around bare conductors. Contact with the conductor could result in electric shock.
- Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and arc blast injury where hazardous live conductors are exposed.
- Never operate the Meter with the back cover removed or the case open.
- Cancer and Reproductive Harm – www.P65Warnings.ca.gov
CAUTION
Meter damage, equipment under test damage or data loss can occur if the
following guidelines are not adhered to.
- Clean the case and accessories with a damp cloth and mild detergents only. Do not use abrasives or solvents. Make sure the meter is completely dry before use.
Product Usage Instructions
- Plug the IDEAL 61-517 GFCI Receptacle Tester into a 120V AC outlet.
- Observe the Green and Red LEDs on the tester. The Green LED indicates proper polarity, while the Red LED indicates mis-wired outlets.
- Check the LCD display on the tester to view the line voltage.
- To test GFCI functioning, press the appropriate button or follow the instructions provided in the manual.
- Always wear the required Personal Protective Equipment (PPE) according to NFPA 70E standards when operating the tester.
- Keep the tester away from children, as it contains small parts the can pose a choking hazard.
- Do not use or play with the tester if you are a child.
- If you are uncertain about any electrical repairs or installations, it is recommended to seek assistance from an experienced electrician.
- Before conducting any work, ensure the circuit is de-energized with the circuit breaker turned off and locked out.
- Inspect the tester’s case for any damage or cracks before each use. Do not use if the tester appears damaged.
- Follow NFPA 70E standards for electrical safety in the workplace when using this tester.
- Replace the batteries promptly when the low battery indicator appears to maintain accurate readings.
- Avoid using the tester during electrical storms or in wet environments to prevent any potential hazards.
- Take precautions to avoid contact with live conductors, as it can result in electric shock.
- When working with hazardous live conductors, always use proper protective equipment to prevent shock and arc blast injuries.
- Do not operate the tester with the case open, as it can lead to meter damage, equipment under test damage, or data loss.
Introduction
The IDEAL 61-517 GFCI Receptacle Tester is a 120V AC plug in outlet tester that indicates proper polarity or mis-wired outlets via Green and Red LEDs and line voltage via a LCD. It also tests for GFCI functioning.
WARNING:
Arc Flash and Shock Hazard, Proper PPE Required. Follow all safety procedures,
wear proper PPE in accordance to NFPA 70E. Read and fully understand the
instruction manual prior to using this product. Failure to comply can result
in serious injury or death.
Contacting IDEAL INDUSTRIES, INC.
To contact IDEAL INDUSTRIES, INC., call one of the following telephone
numbers:
IDEAL Industries USA Customer Service
- Phone Number: 800-435-0705
- Email: contactus@idealindustries.com
IDEAL Industries Canada Customer Service
- Phone Number: 905-683-3400
- Email: ideal_Canada@idealindustries.com
IDEAL Industries EMEA
- Phone Number: +44 (0)1925 444 446
- Email: eur.sales@idealindustries.com
IDEAL Industries Australia
- Phone Number: +61 3 9562 0175
- Email: InfoAUS@idealindustries.com
Or visit the IDEAL Electrical Website at
www.idealind.com
To register your product, find manuals, watch videos, simply scan this QR
code.
Symbols & Descriptions
Operation
Identification and Description of Operating Controls and Functions for the 61-517 GFCI Receptacle/Voltage Tester:
- On Off Button
- GFCI Test Active LED
- GFCI Test Button
- Polarity Legend
- AC Voltage LCD
- Red-Green Polarity Indicator LEDs
- Hot-Neutral-Ground Prongs
Operating Features
High Voltage Warning (HI-V)
The meter indicates a when measuring >30V AC
Backlight
Meter Operation
Voltage and Polarity
First, turn the meter on by pressing the ON/OFF Button and then insert into an
outlet. If the batteries are good, the 61-517 will beep continuously to
indicate live voltage, display the correct voltage, and indicate 3 bright
green LEDS on the top and the bottom IF the HOT NEUTRAL and GROUND polarity of
the outlet is correct. After removing the 61-517 from an outlet it will
continue to display the polarity LED’s and measured voltage value for 5
seconds and shut off after 3 minutes of inactivity. This gives the user time
to unplug from hard to reach or limited access outlets such as those behind
furniture and still have a clear indication of the outlets condition.
If any other polarity condition is encountered other than correct
H-N-G, one or more red lights will illuminate. Refer to the legend to identify
the incorrect wiring condition.
See table on page 13 for all conditions the 61-517 can detect.
NOTE: The 61-517 will automatically turn itself on when inserted into a live outlet. 11
Testing a GFCI
Turn the unit on. Insert the unit into a live GFCI receptacle.
Confirm that the 3 polarity indicators are all green. Press and hold the GFCI
button for 6 seconds or until the GFCI trips. The light next to the GFCI
button will turn RED until the GFCI trips. If the GFCI DOES NOT trip then a
defective GFCI or a wiring issue is likely the cause.
NOTE: Modern GFCI’s will trip when self testing even without a ground
connected. The 61-517 requires a low impedance ground to trip a GFCI. If the
GFCI does not trip, pressing the GFCI repeatedly or for more than 6 seconds
will not make it function and may cause damage to the 61-517.
Polarity Indications TableFunctions Operation TableFunctions Indication Table
Function | Description |
---|---|
LCD | 300 count LCD. Displays VAC and |
LCD Backlight | White backlight. |
High Voltage Alarm | 1) Effective setting: ACV. |
2) In ACV, voltage measurement value: ACV
³30V, LCD displays high voltage alarm is Simultaneously the buzzer emits a
continuous tone.
Over Range Indication| LCD displays “OL” when over range is encountered.
Low Battery Indication| The “ ” symbol appears in the LCD display with
insufficient voltage. The low battery icon will flash for 5 seconds and the
unit will power off.
This ensures accurate readings.
APO| No button presses for 3 minutes will be automat- ically cause the unit to
shut down and enter the low-power state.
Function| Range| Resolution| Accuracy
---|---|---|---
61- 517| ±(a%+b)
AC Voltage (V)| 30 – 150V| 1V| ±(3.0%+2)
GFI (mA)| 6mA~9mA| 102V,>6.0mA| ±(2.0%+5)
SPECIFICATIONS
Mechanical Specifications
Operating Temperature: | 32ºF to 104ºF (0ºC to 40ºC) (<80%RH) |
---|---|
Operating Altitude: | 6500 ft (2000 m) |
Storage Temperature: | 14ºF to 122ºF (-10ºC to 50ºC) (<80%RH) |
Environmental Specifications
Dimensions: (L x W x H)| 3.25 in. x 2.6 in. x 1.25 in.
(85 mm x 65 mm x 33 mm)
---|---
Weight:| 0.25 LBS (0.1 KG)
Display:| LCD
Display Count:| 300
Power Source:| 2 x 1.5V AAA
Battery Life:| 100 Hours Typical
EMC/EMI
CISPR 22 3rd Edition. Class B Limits. EN 55032
CISPR 32 CISPR 11F
FCC 15. 107 with reference to Section 15.109 (g). ICES-003
EN 61326-2-2 Sec 6.4.2.101
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.
Safety
Complies with the following:
IEC 61010-1, Edition 3 (2010-06) +AMD1 (2016-12)
ANSI/UL/IEC EN 61010-1, Edition 3 (2016-04-29)
CSA-C22.2 No. 61010-1-12 Edition 3 (2019-07-19)
IEC 61010-031 Hand-held Probe Assemblies (2015-
05)+AMD1(2018-05)
IEC 61010-2-033 (2019-06)
UL1436
Overvoltage CAT II 150V.
Any voltages exceeding the defined maximum voltage measurement categories
described above are outside the normal use of the equip-ment and protection
cannot be guaranteed.
Pollution Degree Class 2
Maintenance and Service
Equipment Maintenance and Service
Meter Inspection
Do not use if meter appears damaged. Visually inspect the meter to ensure case
is not cracked.
Prong Inspection
Inspect the insertion prongs and ground pin for any signs of corrosion and for
straightness. If the blades are bent, do no use the unit. Return to IDEAL for
service.
Battery Inspection/Replacement
Inspect the battery compartment monthly for any signs of degradation. Low
battery voltages will cause inaccuracies in readings. Remove the batteries for
storage or if the meter will not be used for longer than one month. Battery
leakage will compromise the safety of the meter and cause irreparable damage
to internal components. Maintenance and Storage
Switch off and disconnect the meter completely before carrying out any
maintenance. Clean the case with a damp cloth and mild detergent. Do not use
abrasives or solvents. Keep away from liquids and ensure the meter is
completely dry before use.
Service and Replacement Parts
This unit has no user-serviceable parts.
Disposal of Waste, Electrical & Electronic Equipment
In order to preserve, protect and improve the quality of the environment,
protect human health and utilize natural resources prudently and rationally,
the user should return unserviceable product to relevant facilities in
accordance with statutory regulations. The crossed-out wheeled bin indicates
the product needs to be disposed separately and not as municipal waste.
Do not dispose of this product as unsorted municipal waste. It must be
properly disposed of in accordance with local regulations. Please see
www.epa.gov or www.erecycle.org for additional information.
Disposal of Used Batteries/Accumulators
The user is legally obliged to return used batteries and accumulators.
Disposing used batteries in household waste is prohibited!
Batteries/accumulators containing hazardous substances are marked with the
crossed-out wheeled bin. The symbol indicates that the product is forbidden to
be disposed via domestic refuse. The chemical symbols for the respective
hazardous substances are Cd = Cadmium, Hg = Mercury, Pb = Lead.
You can return used batteries/accumulators free of charge to any collecting
point of your local authority, our stores, or where batteries/accumulators are
sold. Consequently, you must comply with your legal obligations and contribute
to environmental protection.
TWO YEAR LIMITED WARRANTY
This tester is warranted to the original purchaser against defects in material
and workmanship for a period of two (2) years from date of purchase. With
proof of purchase from an authorized IDEAL distributor, a defective tester
will be repaired or replaced with the same product or a functionally
equivalent product, at the option of IDEAL INDUSTRIES, INC. during the
warranty period, subject to verification of the defect or malfunction.
Warranty does not cover consumables such as fuses, batteries, and excludes
defects caused by leakage from batteries, abuse, mishandling, dropping,
ordinary wear and tear, misuse, neglect, unauthorized repair, improper use,
alterations, accidents or any causes beyond IDEAL’s reasonable control.
Consequential or incidental damages are not recoverable under this warranty.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you. This LIMITED WARRANTY gives you specific legal rights, which vary from
state to state. This warranty constitutes the sole and exclusive remedy of the
purchaser and the exclusive liability of IDEAL, and is in lieu of any and all
other warranties, and expressly disclaims all other warranties, implied, or
statutory as to merchantability, fitness for purpose sold, description,
quality productiveness, or any other matter. No agent, distributor or other
supplier has the authority to modify or amend this warranty or make other
representations or warranties other than those contained in this warranty
without express written authorization from IDEAL. For warranty service, call
IDEAL customer service at
1-800-435-0705.
Made in China.
References
- U.S. Environmental Protection Agency | US EPA
- Electronic Waste Management - CalRecycle Home Page
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>