SONNENKONIG TOSAI 241 Instructions

June 3, 2024
SONNENKONIG

SONNENKONIG TOSAI 241

PRODUCT OVER VIEW

SONNENKONIG-TOSAI-241-FIG-17

SPECIFICATIONS


MODEL| 241 A
HEATER TYPE| PORTABLE RADIANT TYPE
HEATING OUTPUT| 2200
FUEL CONSUMPTION RATE| 187 g/h  0.23 L/h
CONTROL HEATING TIME| +/- 16 h
FUEL TANK CAPACITY| 3.8 l
DIMENSIONS (HxWxD) (mm)| 395x345x340
NET WEIGHT| 6,1 kg
GROSS WEIGHT| 7,0 kg
COUNTRY OF ORIGIN| CHINA
FUEL TANK TYPE| LIFT-OUT CARTRIDGE
AUTOMATIC SAFETY SHUT OFF SYSTEM| BUILT-IN
CE| YES
POWER REGULATION| YES
POWER SUPPLY| 4 batteries LR14 or Type C
IS NOT APPROPRIATE FOR ROOMS WHICH HAVE A LOWER SURFACE AS (m3)

(limit height of 2,3 m)

| 34 m3 ( +/- 15 m2)
TYPE OF WICK| SGK 302

This product can not be used as main heating Cleaning and user maintenance shall not be made by children without supervision.

INSTRUCTIONS FOR USE

Prepare the heater for use by carrying out the instruction in the following order:

Unpacking

Remove the heater from the cardboard box. Remove all protections of chock out of polystyrene Remove the sticky tape from the protection grid and open it as described below:

  1. Push the grid forward
  2. Push the grid upwards.
  3. Pull the bottom of the grid facing you.
  4. Pull the grid downwards. Reverse the process to install the grid. Remove the packing material from the conbustion cylinder. Open the lid of the fuel tank compartment and remove the material which protected it during transport.

Fitting the combustion cylinder

Place the combustion cylinder on the circular wick guide. Turn the combustion cylinder lever to the left and then half way to the right until the combustion cylinder is correctly positioned in the circular wick guide. SONNENKONIG-
TOSAI-241-FIG-3

Fitting the batteries ( LR14 or Type C)

Place 4 batteries in the battery case at the rear of the heater. Make sure that you respect the polarities +/- as indicated in the drawing.SONNENKONIG-
TOSAI-241-FIG-4

IMPORTANT: DANGER

  • Never remove the batterie while the heater is operating
  • Make sure of the quality of your batteries
  • Never light your heater with matches or a lighter or other fire.
  • Risk of electric shock. When igniting, the electrodes liberate high voltage. One must keep away from the electrodes.
  • Right after a consumer removes batteries and presses down the ignition lever, high voltage may be discharged.
  • Before cleaning up or repairing the heater, a consumer must remove batteries and discharge electricity by pressing down the ignition lever.

LIQUID COMBUSTIBLE FOR MOBILE HEATER

Type of liquid combustible for mobile heater

We advise you to use the COMBUSTAR

  • More than 95 % of problems are due to using a wrong type of liquid combustible for mobile heater. Those problems are not covered by our warranty.
  • Only top-quality liquid combustible for mobile heater, according to the law of 08/01/98 and 18/07/02 with the aromatics removed and totally free of impurities (max 1 % of aromatics and a flash-point above 61°).
  • Never use contaminated liquid combustible for mobile heater, or which has been chemically treated, contains water or petrol.
  • Your container should be clean and empty when you fill it at a stations-service or to a retailer. No impurities or other liquids (water, diesel, gasoline, etc.) should remain. You ought to keep a container specifically for filling your heater.

Storage of the liquid combustible for mobile heater

Store your liquid combustible for mobile heater away from the sun and from other heat sources. Liquid combustible for mobile heater which has been stored too long loses its purity and thus its efficiency. Do not stock your liquid combustible for mobile heater from a season to an other.

Filling with liquid combustible for mobile heater

Filling procedure and precautions:

Stop your heater
Do not put your container on or near the heater while filling the tank. Lift the lid of the tank compartment and open it. In all the cases, the user must check the good closing of his tank reloaded apart from any naked fire or heat source Use a pump to fill the tank with liquid combustible for mobile heater. Keep on filling until the level of fuel reaches the middle of the fuel gauge. Control the fuel tank every time you fill it. If you see any leak, a deformation or signs of rust, please do replace im-mediately your fuel tank by going to your reseller or after sales service.

Reading the fuel gauge

Presence of liquid combustible for mobile heater will make move the reading on the gauge into the black.
Stop filling when the liquid combustible for mobile heater level reaches the middle of the gauge.

Close the tank securely, and wipe away any spills. Turn the tank over, so that the filler orifice is facing downwards, and carefully put it back into its place.

Obtaining the right quantity of liquid combustible for mobile heater

When the level of fuel in the tank goes down, the fuel gauge will indicate this. The fuel in the tank will be completely used about 1 hour burning after the fuel gauge reached the ‘‘ALL RED‘’ level.

PREPARING TO LIGHT THE HEATER

Levelling the heater

Make sure that the heater is standing on a level surface. If the heater is not level, the automatic shut-off device maybe prevented from working.

Automatic shut-off device in case of knocks

Push the ignition lever downwards untill it stops. The automatic shut-off device (in case of knocks) is ready to work If the knob does not remain downwards, the automatic shut-off device is working. Do not try again and ventilate the room and replace your batteries.

Wick
The first time you use a wick, let it absorb liquid combustible for mobile heater for about one hour. Only use liquid combustible for mobile heater with the aromatics removed, with a flash-point above 61° and free of any impurities, in order to ensure that your wick lasts for a long time. If you find that the wick is abnormally hard, if it is blocked or burning is abnormal, have it replaced by a qualified specialist, for example, the supplier of your heater.

As the wick and replacement of the wick are not covered by the guarantee, follow the instructions for use, in order to obtain optimal performance from your wick. A non original wick that does not have the original adjustments causes damage to the combustion quality with risk of release of carbon monoxide. Your heater would not be anymore in compliance with the European standards Guarantee is not valid without the use of original or PETROWICK wicks

LIGHTING THE HEATER

Before you light the heater, check the  following points

The combustion cylinder must be proprely positioned. Make it rotate pushing the lever from left to right and make sure it is correctly fitted. When you use the heater for the first time, odours may persist for a certain time after lighting. This is normal, as oil and protective grease in the heater have to be burnt off.

Slowly push the ignition lever downwards until the START position . (To await the “beep”)and maintain to it 1 to 2 seconds until the flame is visible. The wick will rise and the heater ignites automatically. Check visually through the glas burner cylinder that the heater is alight. After having carried out the ignition procedure, there may be some white smoke coming out of the ignition zone, without the heater being lit. In this case, move up the ignition lever part way through its travel and the heater will start to operate. This operation must be done slowly and gently. Try several times if lighting is not carried out in the 1 or 2 seconds. In the event of insistence, you risk to roast the lighter or the wick (spare parts non garanted ).

CAUTION: NEVER LIGHT YOUR HEATER WITH MATCHES OR A LIGHTER OR OTHER FIRES

Adjusting the height of the flamme

Combustion can be optimized within a range of 10% by adjusting the height of the flame (see hereafter).
Go up a little the button of adjustment to decrease the combustion .SONNENKONIG-TOSAI-241-FIG-14

If despite the regulation, the flame is too high or if the heater unevenly (its colour is not uniform), take the lever on the combustion cylinder and shake it gently once or twice, go up the lever for the height of the wick. If the problem subsists, stop the heater and contact your retailer. If you continue using your heater with bad combustion, soot and/or CO emission will result.

Using simultaneously a fan, or a humidifier may cause the flame to become slightly pink. This is normal. Never touch the automatic ignition device when the heater is in use. By lowering it you will make the flame rise if you push it too strongly, you may roast the wick

TURNING OFF YOUR HEATER

For a shut-off push the “STOP button”. The automatic shut-off device against knocks will automatically be activated, it will lower the wick very quickly and also put out the flame. It is possible that an excess accumulation of carbon and other deposits on the wick will prevent proper operation of the automatic shut-off device. Make always sure to visually check that the automatic shut-off device has operated properly.

When lighting the heater again

Precautions:
After turning off the heater, wait at least five minutes before lighting the heater again. If the combustion cylinder has not had time to cool down, lighting the heater again may result in odours being given off.

IMPORTANT
Any tampering with or modification to the safety system is prohibited. Apart from invalidating the guarantee, this would risk causing a failure of the system which is there for your safety.

BATTERIES INFORMATION

  • non-rechargeable batteries are not to be recharged
  • rechargeable batteries are to be removed from the appliance before being charged
  • different type of batteries or new and used batteries are not to be mixed
  • exhausted batteries are not to be removed from tthe appliance and safely dispo-sed of
  • if the appliance is to be stored unused for a long period, the batteries are to be removed
  • The supply terminal are not to be short-circuited

RESTRICTION ON USE

This heater may not be used in rooms which are hermetically sealed, such as caravans, boats, passenger compartments of vehicles etc. Do not put something on the heater when it works. This appliance is not foreseen to be used by people (including children) with limited physical capacities, limited senses or mental problems, or by people without any knowledge or experience, unless being supervised by a person responsible for their security. Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision.

IMPORTANT

  • Always preserve a minimum clearance of 1 metre from other objects.
  • Use your heater in a room which is properly ventilated and free of inflammable vapours.
  • Ensure that the room to be heated has an efficient air outlet (see standard health regulations).
  • Do not use your heater in too small a room Heater of 2200 W: Min. 34 m3 ( +/- 15 m2)

DISPOSING OF THIS PRODUCT

This Product and it’s packaging should be disposed of responsibly check with your Retailer or Local Authority as to appropriate methods of disposal.

DO NOT USE YOUR HEATER IN ROOMS SITUATED UNDER THE FLOOR LEVEL.

TROUBLE SHOOTING GUIDE

In case of problems, check here before you take your heater to your dealer.

Company
Armin Schmid Olensbachstrasse 9-15 CH-9631 Ulisbach
Tel. Int. +41 58 611 60 00
Tel. Nat. 0848870850
www.sonnenkoenig.ch

Company
Armin Schmid
Peter-Henlein-Strasse 5
D-89331 Burgau
Tel: 0180 500 64 35
[email protected]
www.sonnenkoenig.ch

References