Product Information

The ISC-PDL1-WAC30G is a wireless motion detector designed for security systems. It operates within the frequency range of 10.500 GHz to 10.525 GHz.

Product Usage Instructions

  1. Ensure that the ISC-PDL1-WAC30G is properly installed and mounted in an appropriate location.
  2. Connect the power source to the motion detector, following the provided guidelines and safety precautions.
  3. Pair the ISC-PDL1-WAC30G with your security system’s control panel or receiver, as per the instructions provided by the manufacturer.
  4. Configure the motion detection settings according to your preferences. This may include adjusting the sensitivity, range, or other specific parameters.
  5. Test the ISC-PDL1-WAC30G by walking within its detection range to ensure proper functionality.
  6. Regularly maintain and clean the motion detector to ensure optimal performance.
  7. Refer to the user manual or contact customer support for any troubleshooting or further assistance.

Following these instructions will help you effectively use the ISC-PDL1-WAC30G wireless motion detector for your security system.

ISC-PDL1-WAC30G:

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 03

Use only a Listed Class 2 Power Limited Source.
For UL Listed product installations, the Listed control unit or a Listed burglary power supply must provide four hours of standby power.

Mounting Instruction

-30°C – +55°C (-22°F – +131°F)
For UL Listed Installations, the temperature range is 0°C – +49°C (+32°F – +120°F), humidity 93%

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 05

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 06

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 07

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 08

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 10

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 11

DIP switch settings and voltage from the control panel to the terminal determines the state of the feature (Remote Walk Test and Alarm Memory) associated with that terminal.

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 12

The Alarm Memory function is used when more than one detector is connected to an alarm loop. The Alarm Memory identifies the units experiencing an alarm in the last armed period. The detector stores the alarm event in memory during the armed period. It shows the stored alarm when the system is disarmed. The LED flashes to indicate the stored alarm. Alarm Memory clears when the system is re-armed.

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 13

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 14

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 15

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 16

Placement if Antimask feature is enabled

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 17

To clear an Antimask condition:

  1. From the control panel, put the detector into Walk Test Mode.
  2. Remove the object that is masking the detector.
  3. Perform a Walk Test. The Anti mask condition clears.

Optional look-down zone

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 18

If necessary, adjust microwave range slightly until required coverage is met.

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 19

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 20

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 21

Perform walk test yearly.
Remote Self-Test: Remote Self-test automatically occurs when walk test changes from disabled to en-abled (change in terminal voltage).
Important: A passing Remote Self-test responds with an alarm signal.

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 22

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 23

Self-tests every 8 h. Self-test and remote self-test failure: 4 blue flashes

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 24

Trouble Memory: Pulse WT input to recall last trouble condition from memory. Pulse WT input again to clear memory. When memory is recalled, it automatically clears after 12 h.

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 25

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 26

Low power supervision activates when voltage falls in the range of 6.5 V to 8 V.

BOSCH -ISC-PDL1-WAC30G- Professional- Series -TriTech -Plus- Curtain-
Detectors- with -Anti-Mask- 28

FCC Compliance Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Please note that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, this equipment should be installed and operated with minimum distance 20 cm (7.9 inches) between the antenna and your body during normal operation. Users must follow the specific operating instructions for satisfying RF exposure compliance.

Bosch Security Systems B.V.
Torenallee 49
5617 BA Eindhoven
Netherlands
www.boschsecurity.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals