SEAIRA Global WatchDog 600c Crawl Space Dehumidifier
Product Information
Manufacturer | Seaira Global, LLC |
---|---|
Address | 14021 NC Highway 50 Surf City, NC 28445 |
Contact | 910-660-0962 |
Specifications
WatchDog dehumidifiers use an integrated humidistat to monitor the
conditioned space. When the relative humidity goes above the selected
setpoint, the dehumidifier will energize. Air is then drawn across an
evaporator coil, which is cooler than the dew point of air. This means
moisture will condense out of the air. The air is then reheated through the
condenser coil and distributed back into the room.
Installation Requirements
Plug dehumidifier into a dedicated 15 amp GFCI circuit.
Key Functions
- Power Key
- Arrow Buttons: Used to adjust humidity level
- Continuous Mode: Allows continuous operation
- Manual Drain Button
- Pump Trouble Warning
- Auxiliary Terminals A5/A6
Indicator Lights
- Humidity Display Screen
- Power Indicator Light
- Continuous Mode/Auto Defrost Light
- Compressor Light
Remote Control Instructions
WatchDog Dehumidifiers can be controlled using an optional remote accessory. The remote connects to your dehumidifier via a 25′ CAT 5 cable, with the integrated sensor giving you multiple options for monitoring surrounding conditions.
Example #1- Install the dehumidifier in the laundry room and duct it into the living room. Mount the remote in the living room and use the remote sensor.
Example #2- Install the dehumidifier in your crawl space with the remote mounted in your garage.
NOTE: The symbols indicated below only show when the remote is powered on.
Button | Action |
---|---|
On/Off (Power) Button | Press the button to start or stop the machine. |
Up Button/Down Button | Use the buttons to adjust the humidity level. |
Mode | Use the button to switch between dehumidifier and a ducted |
application.
Temperature| The T button changes the temperature reading on your remote.
Press once to switch to Fahrenheit.
Continuous| Press the button to switch the unit into continuous mode. CONT.
will appear on the display screen.
Important Notes
- Always connect your dehumidifier using a grounded, dedicated electrical connection that is GFCI protected with at least 15 amp capacity.
- The use of any other type of wiring will void your warranty.
- Install dehumidifier according to all applicable local, state, and national codes
- Be sure to follow your GFCI manufacturer’s maintenance instructions. You will typically need to test the operation of the trip circuit monthly.
- For ease of testing and operation, it may be helpful to put the test switch and indicator lights in a convenient location.
- Your dehumidifier should only be repaired by a qualified technician.
- Do not insert objects or your fingers into the inlet or discharge.
- Do not use water to clean the exterior of the dehumidifier. To clean unit, unplug from power, then use a damp cloth to wipe the exterior.
- Do not stand on dehumidifier or place objects on it.
- Do not use with extension cord or plug adapter.
- Unless otherwise noted, all maintenance should be done with the unit powered off.
Warranty Registration
Your dehumidifier comes with an extensive warranty. To register your unit
simply fill out and return the warranty form provided in your dehumidifier
box.
For future reference, write down the model, serial number, and date of
purchase for your dehumidifier. This information is necessary for seeking
assistance in the future and can be found on the data label on the side of the
unit.
- Model Number:
- Date Of Purchase:
- Serial Number:
For additional questions concerning your dehumidifier, contact your local installer or call Seaira Global at 910-660-0962.
Specifications
- Capacity @ 80°F/60%RH: 60 Pints Per Day
- Airflow @ 0.0” SP: 155CFM
- Operating Temp. Range: 33-105°F
- Operating Relative Humidity Range: 36%-90%
- COP: 2.6 L/kWh
- Refrigerant: R410A
- Amperage Usage: 4.05 Amps
- Power Supply: 115V/60Hz/Single Phase
- Outlet Requirement: 15 Amp, 3 Prong, GFCI
- Sound Level: 59 dBa
- Dimensions LxWxH: 21.7” x 12” x 12”
- ETL Listed: Yes
- ENERGY STAR® Rated: Yes
How It Works
WatchDog dehumidifiers use an integrated humidistat to monitor the conditioned
space. When the relative humidity goes above the selected setpoint, the
dehumidifier will energize. Air is then drawn across an evaporator coil, which
is cooler than the dew point of air. This means moisture will condense out of
the air. The air is then reheated through the condenser coil and distributed
back into the room.
Installation Requirements
- The area where the dehumidifier is located should be sealed with a vapor barrier.
- If the unit is installed in a crawl space, all vents should be sealed.
- For proper ventilation, neither the inlet or discharge should be positioned against a wall. The inlet needs a minimum of 12” clearance and the discharge requires a minimum of 36” clearance.
- For the best air diffusion, install the unit so that a side panel faces the wall.
- WatchDog dehumidifiers are only intended for operation when the unit is upright and level with the feet on the ground.
Installation
-
Place dehumidifier on a level surface.
Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a level surface.
If unit has been turned or flipped so that the compressor did not remain upright, place the unit on a level surface and wait a minimum of 2 hours before proceeding. -
Set up the drain line
Remove the compression nut and slide it over the end of the hose to be attached to unit.
Slide the side of hose with compression nut over the insert on the compression fitting completely.
Secure compression nut. **Do Not Overtighten. -
Plug dehumidifier into a dedicated 15 amp GFCI circuit.
Key Functions
Power Key
- Use this button to turn the dehumidifier on and off.
- Press once to turn machine on. You will hear two beeps and the light will illuminate green (solid or flashing depending on mode).
- Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a 1 minute fan delay.
Arrow Buttons
- Use the up and down arrows to set the desired humidity setpoint on the display screen.
- The setpoint can be any number between 36%-90%. When the indoor humidity is higher than the setpoint, the unit will operate.
- Keep in mind that the displayed humidity levels are approximate ( +/-5%)
Continuous Mode
- To set the unit to run continuously regardless of humidity, simply use the down arrow key to set the humidity below 36%.
- The continuous light will illuminate green and the display will show “CO”.
- To switch back to normal humidistat operation, use the arrow keys to move the setpoint above 36%.
Manual Drain Button
If you need to store or move your dehumidifier, press the “Drain” button to
remove water from the integral pump’s reservoir.
Pump Trouble Warning
-
If the pump reservoir level gets too high, the water sensor will activate to prevent overflow.
-
When this occurs, the compressor will stop
automatically, and the display will show “E4”. After a 1 minute delay, the fan motor will turn off and the dehumidifier will not operate until the problem has been resolved. -
Check to verify that the pump is functioning, then unplug the unit for two minutes to reset the error code.
Auxillary Terminals A5/A6
- The A5/A6 on the terminal strip can be used as a safety switch for an external float switch.
- It should be set to N/O (normally open) at the accessory float switch.
- If an E4 error occurs immediately , switch the wiring on external swtich to N/C (normally closed). You may need to unplug the unit to reset the error code.
Indicator Lights
Humidity Display Screen
The display screen has two functions:
- When the unit is powered on, it shows the humidity of the space
- When setting the desired humidity level, the screen will show the set point. After a brief delay, it will revert to current humidity of the space.
Power Indicator Light
- This light indicates that the unit is properly powered on and ready to operate.
- Always make sure the unit is “off” prior to performing any service, unless otherwise indicated.
- If the humidity is above the setpoint, the light will be solid green and the machine will operate.
- If the humidity is below the setpoint, the unit will be in standby mode and the light will be flashing.
Continuous Mode/ Auto Defrost Light
- When the light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
- When the light illuminates red, it means the unit is in auto defrost mode and clearing the evaporate coils of any ice buildup.
Compressor Light
- When the light illuminates red, it indicates the compressor has been initiated but is currently warming up.
- Once the light switches to green, it means the compressor is currently in working status.
Remote Control Instructions
WatchDog Dehumidifiers can be controlled using an optional remote accessory.
The remote connects to your dehumidifier via a 25’ CAT 5 cable, with the
integrated sensor giving you multiple options for monitoring surrounding
conditions.
Example #1- Install the dehumidifier in the laundry room and duct it into the
living room. Mount the remote in the living room and use the remote sensor.
Example #2- Install the dehumidifier in your crawl space with the remote
mounted in your garage.
NOTE: The symbols indicated below only show when the remote is powered on.
-
On/Off (Power) Button
Press the on/off button and the machine will start running. Press the button again to turn the machine off. -
Up Button/ Down Button
Use the up and down arrows to adjust the humidity level. -
Mode
Use the mode button to switch between dehumidifier and a ducted application.- The symbol on the display indicates the sensor on the remote control is being utilized.
- The symbol on the display indicates the sensor on the dehumidifier is being utilized.
-
Temperature
The T button changes the temperature reading on your remote. The remote comes from the factory in Celsius. Press this button once to switch to Fahrenheit. -
Continuous
Press this button to switch the unit into continuous mode. “CONT.” will appear on the display screen. -
Drain Pump
Use this button if the unit will not be used for an extended period of time. This button will remove water from the pump reservoir.
Operating Instructions
-
Start the machine
Press the power key to turn the dehumidfier on. -
Adjust the settings
Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%) -
Stop the machine
Press the power button again and the dehumidifier will stop. Note that the fan will continue to operate for 1 minute after the unit has shut off. DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP. -
Water Drainage
The WatchDog 600c has an integrated condensate pump. During normal operation, the 600c will automatically drain as required.
If you would like to store or move your unit, press the drain button to drain water from the pump reservoir. The drain will operate for 15 seconds each time the button is pushed. It may be necessary to push the button more than once.
Unit Diagram
Maintenance
For more detailed instructions, visit
www.SeairaGlobal.com.
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Machine Body
Use a soft, damp cloth to clean the exterior of unit. Do not use any soap
or solvents
Coil Maintenance
Once per year, clean the coils with an approved coil cleaner. The coil cleaner
should be a self-rinsing, foaming, cleaner, such as WEB® Coil Cleaner.
Cleaning the Filter
- Unplug the unit.
- For PreFilter:
- Remove prefilter from inlet of machine.
- Vacuum or wash with warm water (no soap).
- For MERV-10/HEPA/Carbon Filters:
- Replace as necessary- we recommend checking the filter at least 1x/year
Electrical Access
- Unscrew the 9 screws on the side board.
- Remove the 2 screws on the control board cover.
Pump Maintenance
Your WatchDog 600c is equipped with an integral condensate pump desinged to
pump water from the dehumidifier out to the desired drain. The pump requires
routine mainteance that is not covered by the warranty.
Preventative maintenance is necessary to prevent issues from dirt and slime
that may accumulate in the drain system. This includes the drain pan, hose to
the condensate pump, pump reservoir, pump head assembly, and discharge tubing.
Removing the Pump
- Remove the 9 screws on the side panel and set panel aside.
- Remove the screw holding the pump in place.
- Undo the 3 pump electrical quick connects and 1 drain quick connect.
- Insert a flat head screwdriver into the notch on the side of the pump. This will allow you to gently lift the pump off its reservoir (the reservoir remains attached to the unit).
Basic Pump Cleaning
Complete about once per year, depending on environment
- Remove filter(s) from inlet of unit to access drain tray. Press the drain button to drain the reservoir.
- Disconnect power to the dehumidifier.
- Mix a 16 ounce solution of bleach (1 oz bleach + 15 oz water) OR vinegar (4 oz white vinegar + 12 oz water).
- Pour the cleaning solution into the drain tray at the base of the coils. If any cleaning solution gets on the coils, flush with water.
- Allow solution to soak for 15 minutes.
- Reconnect the dehumidifier to power.
- Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.
- If the drain line is still filled with debris, repeat process. If drain line still does not appear clean, move on to Advanced Cleaning.
Advanced Pump Cleaning
Complete as needed
- Press the drain button to drain the water from the reservoir (a wet-dry vacuum or towels can be used to remove any remaining water).
- Unplug the dehumidifier and remove the cover so you have access to the pump.
- Remove the pump head from the reservoir by unscrewing the screw. Wipe reservoir clean with a paper towel.
- Reassemble pump.
- Mix a 16 ounce solution of bleach (1 oz bleach + 15 oz water) OR vinegar (4 oz white vinegar + 12 oz water).
- Pour the cleaning solution into the drain tray at the base of the coils. If any cleaning solution gets on the coils, flush with water.
- Allow solution to soak for 15 minutes.
- Reconnect the dehumidifier to power.
- Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Turn off the unit and allow it to dry.
- Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservour.
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Ducted Applications
Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. Both the inlet/return grille and the supply grille are designed for 10” flex ducting.
Ducting Installation Notes
- Be sure to secure the ducting with tie wrap.
- Maximum total length of duct run = 10’
- Inlet and outlet duct adapters are optional accessories
Duct Adapter Installation
Screw in the 4 screws on each duct adapter.
Flex Duct Installation
Slide ducting over adapter and secure with tie wrap or clamps.
Troubleshooting
Pump Alarm- E4 Error Code
UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED.
If E4 (pump alarm) is shown on the display, complete the following steps:
- Reset the unit by unplugging the power cord and then reconnecting it.
- Manually check to see if the pump is operational by pressing the drain button. Check if the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.
- If you haven’t cleaned the system recently, check the discharge line for an obstruction, then clean as described in the Maintenance section.
- Replace the hose and/or pump, if maintenance alone isn’t sufficient.
Spare Parts
Limited Warranty
All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned.
5 Years (From Date of Purchase):
Seaira Global warrants the dehumidifier will operate free of defects in
workmanship and materials. At its discretion, Seaira will repair or replace
any malfunctioning components, free of charge
(excluding transportation costs)
Customer Responsibilities:
In order to take advantage of the warranty service, the customer must do the
following:
- Customer must provide normal care and maintenance (including, but not limited to cleaning filters, coils and pumps)
- Removal and re-installation of unit is the sole responsibility of owner.
- If customer cannot return unit to certified repair center, all costs associated with freight shipment are borne by the customer. In addition, all ancillary charges related to freight shipments including but not limited to palletizing, wrapping, labeling, and pickup are associated with customer.
- If shipped, customer is responsible for all risk of loss or damage.
Warranty Procedure:
-
Customer must mail in warranty registration card to Seaira Global. If no card is submitted, warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date of installation in the spaces provided on page 2 of the manual. You will need this information to receive an RA number.
-
If warranty service is necessary, customer must contact Seaira Global Tech Support by phone 910-660-0962 to receive a Return Authorization (RA number).
-
Once an RA has been issued, it is the customer’s job to bring the unit to a certified repair center.
If this is not an option, shipping will be arranged to bring the unit back to the Seaira warehouse (at the expense of the customer). -
After the unit has been received by Seaira (whether at a repair center or the warehouse), an initial inspection will be completed, if it is determined to be an invalid warranty claim (see exclusions below), unit will only be completed after receiving payment from customer for all associated costs.
-
If unit is defective, the necessary parts will be repaired or replaced and the unit will be available for pickup at certified repair center or returned via freight shipment (at customer’s expense). Keep in mind that work is only done during normal working hours. After being repaired, all units are required to go through a rigorous testing process prior to being returned to customer.
-
Once a part is repaired and the dehumidifier is returned, the original warranty period still applies (no extensions).
Warranty Exclusions
THE FOLLOWING IS NOT COVERED UNDER WARRANTY
-
ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO:
- FLOODING
- FIRE
- WATER DAMAGE
- HURRICANE/STORM DAMAGE
-
IMPROPER USAGE- INCLUDING BUT NOT LIMITED TO:
- POOL/SPA/TUB APPLICATIONS
- MISUSE, ABUSE, OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL
- IMPROPER INSTALLATION OR DESIGN
- IMPROPER VOLTAGE
- LACK OF NORMAL CARE
- FAILURE TO FOLLOW INSTRUCTIONS
-
CORROSION
-
FREEZING
-
ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES
-
FREIGHT CHARGES
-
ANY COSTS DUE TO LOST PROFIT OR DELAY
-
DAMAGE TO PROPERTY
-
CAUSE BEYOND CONTROL
-
CONSUMABLE PARTS, INCLUDING BUT NOT LIMITED TO:
- FILTERS
- BATTERIES
- POWER CORDS
- VALVES
- SWITCHES
- RUBBER PARTS
-
APPLICABLE LAW AND VENUE
ALL ASPECTS OF THIS AGREEMENT SHALL BE INTERPRETED BY AND UNDER THE LAWS OF THE STATE OF NORTH CAROLINA. ANY LITIGATION, ENFORCEMENT OF ARBITRATION, OR LITIGATION RELATED TO SHALL BE BROUGHT IN THE APPROPRIATE COURT IN NEW HANOVER COUNTY, NORTH CAROLINA. -
DIRECT, INDIRECT, COLLATERAL OR INCONSEQUENTIAL DAMAGES OF ANY KIND
THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIEDWARRANTIES OF
MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE. SEAIRA GLOBAL’S TOTAL
LIABILITY, REGARDLESS OF NATURE OF CLAIM SHALL NOT EXCEED ORIGINAL PURCHASE
PRICE OF THE PRODUCT. IF A PRODUCT OR COMPONENT IS REPLACED WHILE UNDER
WARRANTY, THE APPLICABLE WARRANTY PERIOD SHALL NOT BE EXTENDED BEYOND THE
ORIGINAL WARRANTY TIME PERIOD.
THE FOREGOING SHALL CONSTITUTE THE TOTAL LIABILITY OF SELLER IN THE CASE OF
DEFECTIVE PERFORMANCE OF ALL OR ANY OF THE EQUIPMENT OR SERVICES PROVIDED TO
BUYER. BUYER AGREES
TO ACCEPT AND HEREBY ACCEPTS THE FOREGOING AS THE SOLE AND EXCLUSIVE REMEDY
FOR ANY BREACH OR ALLEGED BREACH OF WARRANTY BY SELLER. ANY DISHONESTY OR
FRAUD IN CONNECTION WITH SEAIRA GLOBAL WARRANTY THOROUGHLY VOIDS ALL WARRANTY
POLICIES. SEAIRA GLOBAL EXPRESSLY RESERVES THE RIGHT TO PURSUE LEGAL ACTION IN
THE EVENT OF DISHONESTY, FRAUD, OR ATTEMPTED FRAUD.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>