MACROARRAY DIAGNOSTICS Stop Solution Instruction Manual
- June 12, 2024
- MACROARRAY DIAGNOSTICS
Table of Contents
STOP SOLUTION
INSTRUCTION FOR USE
DESCRIPTION
The Stop Solution is used during processing of ALEX technology-based arrays as
described in their respective Instructions for Use. The Stop Solution can be
used in both manual and automated procedures by trained laboratory personnel
and medical professionals.
The Stop Solution is used during the assay to stop the color reaction on the
arrays.
INTENDED USE
The Stop Solution is an accessory to ALEX technology-based assays.
The IVD medical product is used as indicated in the respective Instructions
for Use and is used by trained laboratory personnel and medical professionals
in a medical laboratory.
| Important information for users!
Please read the Instructions for Use thoroughly. This is the only way to
ensure that the product is used correctly. The manufacturer accepts no
responsibility for improper use or for modifications made by the user.
---|---
SHIPMENT AND STORAGE
Shipment of the Stop Solution takes place at ambient temperature.
The reagent must be stored at 2 – 8 °C until use. If stored correctly, the
reagent is stable until the stated expiry date.
| The opened Stop Solution can be used for 6 months (at recommended storage
conditions).
---|---
WASTE DISPOSAL
Used and unused reagents can be disposed with laboratory waste. All national and local disposal regulations must be followed.
GLOSSARY OF SYMBOLS
| Manufacturer
---|---
| Date of expiry
| Batch number
| REF number
| Do not use if packaging is damaged
| Store away from light
| Store dry
| Storage temperature
| Pay attention to Instructions for use Link to download the IFU
| In vitro diagnostic medical device
| Unique device identifier
| CE mark
| Important note
| Attention (GHS hazard pictogram)
Consult the Safety Data Sheet for more information.
REAGENTS AND MATERIAL
The Stop Solution is packaged separately. Expiration date and storage temperature are indicated on the label. The reagents are not to be used after their expiry date.
| The Stop Solution is not batch-dependent and can therefore be applied
regardless of the kit batch used (ALEX² and/or FOX).
---|---
Item| Quantity| Properties
---|---|---
Stop Solution (REF 00-5007-01)| 1 container à 10 ml|
Ethylenediaminetetraacetic acid (EDTA)-Solution
The Stop Solution is ready for use. Store at 2 – 8 °C until expiry date.
Before use, the solution must be brought to room temperature. The opened
solution is stable for 6 months at 2 – 8 °C.
May become cloudy if stored for a long time. This does not affect test
results.
WARNINGS AND PRECAUTIONS
- It is recommended to use gloves, safety goggles and a lab coat when handling patient samples and reagents, as well as to follow good laboratory practice (GLP).
- The reagents are for in vitro use only and not to be used for internal or external use in humans or animals.
- Upon delivery, the containers must be checked for damage. If any component is damaged (e.g., buffer container), please contact MADx (support@macroarraydx.com) or your local distributor. Do not use damaged kit components, this may affect kit performance.
- Do not use expired kit components
Required materials available from MADx, which are not included in the kit:
- ImageXplorer
- MAX device
- RAPTOR Server Analysis Software
- ALEX² Allergy Xplorer
- FOX Food Xplorer
- Humidity chamber
- Shaker (see ALEX²/FOX for detailed specifications)
- Array holders (optional)
Required consumables not available from MADx:
- Pipettes
- Distilled Water
IMPLEMENTATION AND PROCEDURE
Use the Stop Solution in accordance with the appropriate procedure. For further information, see the MAX Devices Instruction for Use or the Instructions for Use of the corresponding MADx test kits.
| If serious incidents occur in connection with this product, they must be
reported to the manufacturer at
support@macroarraydx.com immediately!
---|---
Analysis performance characteristics:
The Stop Solution is intended to be used only in combination with assays based
on ALEX technology. The product does not perform an analytical or a clinical
analysis on its own.
WARRANTY
The performance data presented here was obtained using the indicated procedure. Any change in procedure may alter results. Macro Array Diagnostics disclaims any warranty in such cases. This concerns the legal guarantee and the usability. Macro Array Diagnostics and their local distributors will not be held responsible for any damage in these cases.
© Copyright by Macro Array Diagnostics
Macro Array Diagnostics (MADx)
Lemböckgasse 59/Top 4
1230 Vienna, Austria
+43 (0)1 865 2573
www.macroarraydx.com
Version number: 00-07-IFU-01-EN-02
Date of Issue: 2022-09
macroarraydx.com
CRN 448974 g