QUECTEL BC20 Module User Guide
- June 12, 2024
- QUECTEL
Table of Contents
GENIE User Guide
BC20 &BC26&BC66 Module Series Version: 1.0
Date: 2022-12-01
Status: Released
BC20 Module
At Quested, our aim is to provide timely and comprehensive services to our
customers. If you require any assistance, please contact our headquarters:
Quectel Wireless Solutions Co., Ltd.
Building 5, Shanghai Business Park Phase III (Area B), No.1016 Tianjin Road,
Mishanga District,
Shanghai 200233, China
Tel: +86 21 5108 6236
Email: info@quectel.com
Or our local offices. For more information, please visit:
http://www.quectel.com/support/sales.htm.
For technical support, or to report documentation errors, please visit:
http://www.quectel.com/support/technical.htm.
Or email us at: support@quectel.com.
Legal Notices
We offer information as a service to you. The provided information is based on
your requirements and we make every effort to ensure its quality. You agree
that you are responsible for using independent analysis and evaluation in
designing intended products, and we provide reference designs for illustrative
purposes only. Before using any hardware, software or service guided by this
document, please read this notice carefully. Even though we employ
commercially reasonable efforts to provide the best possible experience, you
hereby acknowledge and agree that this document and related services hereunder
are provided to you on an “as available” basis. We may revise or restate this
document from time to time at our sole discretion without any prior notice to
you.
Use and Disclosure Restrictions
License Agreements
Documents and information provided by us shall be kept confidential, unless
specific permission is granted. They shall not be accessed or used for any
purpose except as expressly provided herein.
Copyright
Our and third-party products hereunder may contain copyrighted material. Such
copyrighted material shall not be copied, reproduced, distributed, merged,
published, translated, or modified without prior written consent. We and the
third party have exclusive rights over copyrighted material. No license shall
be granted or conveyed under any patents, copyrights, trademarks, or service
mark rights. To avoid ambiguities, purchasing in any form cannot be deemed as
granting a license other than the normal non-exclusive, royalty-free license
to use the material. We reserve the right to take legal action for
noncompliance with abovementioned requirements, unauthorized use, or other
illegal or malicious use of the material.
Trademarks
Except as otherwise set forth herein, nothing in this document shall be
construed as conferring any rights to use any trademark, trade name or name,
abbreviation, or counterfeit product thereof owned by Quectel or any third
party in advertising, publicity, or other aspects.
Third-Party Rights
This document may refer to hardware, software and/or documentation owned by
one or more third parties (“third-party materials”). Use of such third-party
materials shall be governed by all restrictions and obligations applicable
thereto.
We make no warranty or representation, either express or implied, regarding
the third-party materials, including but not limited to any implied or
statutory, warranties of merchantability or fitness for a particular purpose,
quiet enjoyment, system integration, information accuracy, and non-
infringement of any third-party intellectual property rights with regard to
the licensed technology or use thereof. Nothing herein constitutes a
representation or warranty by us to either develop, enhance, modify,
distribute, market, sell, offer for sale, or otherwise maintain production of
any our products or any other hardware, software, device, tool, information,
or product. We moreover disclaim any and all warranties arising from the
course of dealing or usage of trade.
Privacy Policy
To implement module functionality, certain device data are uploaded to
Quester’s or third-party’s servers, including carriers, chipset suppliers or
customer-designated servers. Quectel, strictly abiding by the relevant laws
and regulations, shall retain, use, disclose or otherwise process relevant
data for the purpose of performing the service only or as permitted by
applicable laws. Before data interaction with third parties, please be
informed of their privacy and data security policy.
Disclaimer
a) We acknowledge no liability for any injury or damage arising from the
reliance upon the information.
b) We shall bear no liability resulting from any inaccuracies or omissions, or
from the use of the information contained herein.
c) While we have made every effort to ensure that the functions and features
under development are free from errors, it is possible that they could contain
errors, inaccuracies, and omissions. Unless otherwise provided by valid
agreement, we make no warranties of any kind, either implied or express, and
exclude all liability for any loss or damage suffered in connection with the
use of features and functions under development, to the maximum extent
permitted by law, regardless of whether such loss or damage may have been
foreseeable.
d) We are not responsible for the accessibility, safety, accuracy,
availability, legality, or completeness of information, advertising,
commercial offers, products, services, and materials on third-party websites
and third-party resources.
Copyright © Quectel Wireless Solutions Co., Ltd. 2022. All rights
reserved.
About the Document
Revision History
Version | Date | Author | Description |
---|---|---|---|
– | 12/1/2022 | Herbert Pan | Creation of the document |
Foreword
In this document, it illustrates how to capture DEBUG log on BC20/BC26/BC66 Series under LPWA modules. In addition, it can be available to capture DEBUG log of such above modules in a fast and effective way via this document. Finally, it can be implemented on relevant applicable analysis based on certain contents.
1.1. Scope
Tools | Manufacturer Revision | Applicable Module Type |
---|---|---|
Genie | AT+CGMI/MTK_2625 | BC20/BC26/BC66 |
1.2. Download
GENIE
MT2625_nbiot_tools_20220930_exe_V1.2240.5.zip
Note: The tool has a validity period. If it has been expired when
deploying, please feel no hesitation to contact with Quectel.
1.3. Device Connection
If the module has been welded or debugged separately, it is recommended to
connect to the Genie and capture log as shown below.
Under the circumstance that the TE-B corresponding to MTK module is deployed, please select the second COM port in the “Port” under the drop-list of “Device Manager” , which means the “Silicon Labs Quad CP2108 USB to UART Bridge: Interface 1” will be used to serve as GKI port. While the third COM port, Silicon Labs Quad CP2108 USB to UART Bridge: Interface 2, will serve as HSL port.
Installation
Being installation-free, the Genie can be used after being unzipped. Run Genie.exe in the directory of MT2625_nbiot_tools_20220211_exe_V1.2207.5\nbiot\tools\core\genie.
Connection
Click the genie icon above to start, the initial display is as shown below; Select “New Config” for related settings.
3.1. UART Connection
The GKI (mandatory one) corresponds to Debug port. While the HSL (optional,
untick it if the AUX port is not induced) corresponds to AUX port. In
addition, the .defile in the corresponding firmware file is imported into the
Database.
As for configuring baud-rate, run the AT command “AT+EPORT=4” to query the
supported UART port in current module and configure according to the returned
value and corresponding table
If it is needed to modify the baud-rate of DEBUG port, please refer to
following AT command and corresponding configuration list.
AT+EPORT=3,2,
+EPORT: | 0 | 1 | 2 | 3 | 4 | 5 |
---|---|---|---|---|---|---|
UART | UART | UART | UART | USB | USB | |
variable | 921600 (fixed) |
Genie Baud-rate Configuration(AT+EPORT=4)
Baudrate_index| Baud-rate=| 0| 1| 2| 3| 4| 5|
| Baud-rate| 110| 300| 1200| 2400| 4800| 9600|
Baudrate_index| Baud-rate=| 6| 7| 8| 9| 10| 11| 12
| Baud-rate| 19200| 38400| 57600| 115200| 230400| 460800| 921600
3.2. USB Connection
If the USB is used to output Log, please execute AT commands and set as shown
below; It is recommended to disable USB output via relevant commands after the
log is outputted.
Open USB output
AT+EPORT=1,uls,5
AT+EPORT=1,emmi,4
Close USB output
AT+EPORT=1,uls,2
AT+EPORT=1,emmi,1
After above steps, power on or restart the device to take effect. The ports
displayed in device Manager are as follows:
It is available to modify and save configuration parameters via corresponding icon in the toolbar as shown below, or by “New Config” / “Save Config” in the drop-list of “Config”.
Then, click the icon in the toolbar as shown below to start recording log;
Note: After the device is powered on, it is necessary to call POWERKEY to
power on the module.
Subsequently, the window will display as follows.
As shown below, the engineering mode in Genie is enabled to facilitate the observation of the signal reference received by the terminal.
As shown below, open genie signaling window via the “RRC Decoder” in the drop- list of “Special”, it is convenient to observe the terminal signaling interaction;
Save Log
4.1. Manual Save
After the log is captured, save the log by “Save As” under the menu of “Log”.
Common Analytical Application
5.1. Import Log
It is available to open log via clicking the saved xxx.glp file or initiating
Genie. See next figure for details.
5.2. Hue the Message
By using icons in the toolbar as shown below, different types of Log messages
can be hued with various colours, which makes it easier to identify and query.
5.3. Filter Log
Open the Find/Search window shown via icons in the toolbar below, or the
“Find” hidden in “Edit”. Please note the case options and search direction;
5.4. Data Analysis
Open following window via “RRC Decoder” in menu of “Special”, the message in
NAS/AS layer can be decrypted.
5.5. Export Pcap
Open following window via “RRC Decoder” in menu of “Special”, select “Export”
and refer to corresponding option to export Pcap file
Notes
- If the issue that debugging or analyzing can be attributed to the event of registration, please run AT command AT+CFUN=0/AT+CFUN=1or reboot module/terminal after connecting to Genie to capture the complete registration network process, which can be applied for the possible cause of the failure to current registration network.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>