ALKOVA 5B-56 56 Inch DC Motor Ceiling Fan Instruction Manual
- June 12, 2024
- ALKOVA
Table of Contents
- Safety Precaution
- Parts & Accessories
- Installation Instruction
- Transmitter Learning Process
- Transmitter Function
- Function of Forward & Reverse
- Transmitter Assembly
- Power Supply Connection
- Circuit Diagram
- Maintenance
- Technical Specifications
- Customer Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EXCEL V2
5B/56
5B/48
5B/42
Instruction Manual
Version: 2022 V1
Safety Precaution
WARNING
Installation and maintenance work shall only be performed by qualified
persons, familiar with local code and regulation, and experienced with this
type of appliance.
All field wiring must be installed in accordance with the national wiring
regulation.
Ensure that the rated voltage of the unit corresponds to that of the name
plate before commencing wiring work according to the wiring diagram.
The appliance must be permanently connected to the electricity supply through
a double pole switch having a contact separation of at least 3mm in all poles.
The unit must be GROUNDED to prevent possible hazard due to insulation
failure.
The earth wire is approximately 60mm longer than safety wire. This is to
ensure at the event whereby the suspension system fails, the (L) and (N) wire
will break leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screw driver.
Blades that are detached from the unit during operation will cause serious
injuries and property damages.
WARNING
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Confirm that the power supply has been switched OFF before installing or
servicing the unit. Ensure that the blade is fully static before doing any
maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the
ceiling fan and contact the manufacturer, its service agent or suitably
qualified persons.
CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices
shall be fixed with a sufficient strength to withstand 4 times the weight of
the ceiling fan.
CAUTION
The mounting of the suspension system shall be performed by the manufacturer,
its service agent or suitably qualified persons.
The fan is to be installed so that the blades are more than 2.5m above the
floor.
Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must
not rely on the earthing conductor.
The earthing terminal in the fan assembly should be such that should any part
of the suspension system fall off, the body of the fan assembly shall
effectively earthed.
Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury
hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch
to the “OFF” position.
If this is not done, the unit’s fans will start turning automatically when
power resumes, posing a harzard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use
in room where mineral oil, oil vapour or oil steam exist, this may cause
plastic part to melt or deform as a result of excessive heat or chemical
reaction.
Avoid the ceiling fan unit from exposing to direct sunlight, this may cause
degradation of plastic material as a result of excessive heat and UV radiation
Ensure the colour of wires of the outdoor unit and the terminal markings are
same to the indoors respectively.
Do not use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades. Avoid raising objects or
your arms near the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.
Replacement of parts of the safety suspension system device shall be performed
by the manufacturer, its service agent or suitably qualified persons.
Torque value for screw/bolts for securing primary suspension system for motor
is 2Nm.
Parts & Accessories
Installation Instruction
-
Assemble the Canopy and Coupling Cover through the Downrod.
-
Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and tighten them firmly then insert the Clevis Pin.
IMPORTANT : CLEVIS PIN MUST BE INSERT TO PREVENT NUT FROM LOOSENING. -
a. Remove the Bolt, Washer, Nut, Clevis Pin and Rubber Pulley from downrod.
b. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Washer, Nut and Clevis Pin.
IMPORTANT : CLEVIS PIN MUST BE INSERT TO PREVENT NUT FROM LOOSENING. -
a. Remove the Safety Wire screw and spring washer from the Downrod.
b. Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire onto the Downrod. -
a. Connect the Connectors from Fan and Receiver.
b. Connect the wires from the receiver to House’s Supply Wire.
c. Connect Earth Wire to House Supply Earth Terminal.
IMPORTANT : ASSEMBLE THE BLADES ONLY AFTER THE CEILING FAN IS MOUNTED ON THE HOOK.
-
a. Lift up Coupling Cover, install the Blades on Motor with Blade Screw and Washer.
b. Install the Decorative Cover by twisting clockwise. -
Below shows a complete installation diagram
Transmitter Learning Process
The receiver & transmitter is pre-programmed in factory. If you wish to
control 2 or more fans using 1 transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Turn on power to fan.
Within 30 sec, press and hold “LEARN” button for 3 sec.
Once receiver has detected the frequency, transmitter with “Beep Beep” twice.
Programming process is completed and fan is ready to use.
Transmitter Function
The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will operate as the last setting.
Function of Forward & Reverse
Fan must be turned on and rotating.
Press and hold Forward/Reverse button for 3 sec. Fan will slow down and then
change direction (approx.15 sec). When the fan is slowing down to change
direction, the Fan Speed function is disabled until direction has been
changed.
Forward
Fan rotates anti-clockwise blowing the air downwards creating the wind chill
effect. Suitable for hot weather condition.
Reverse
Fan rotates clockwise drawing the air towards the ceiling circulating the warm
air downwards. This function works best at low speed. Suitable for air-
conditioned condition.
Transmitter Assembly
Install the Transmitter Holder to wall with the 2 Screws provided.
Power Supply Connection
Circuit Diagram
Maintenance
Due to the fan’s natural movement, connections may get loose after a period of
usage. To ensure a proper and safety usage, it is highly recommended to
inspect and tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning
procedures are as follows :
- Use only lukewarm water. Do not use detergent, corrosive or acidic solution.
- Damp the cloth lightly. Use only soft or lint -free cloth to clean the fan. Rough fabric will scratch the surface.
- Do not bend the blades while cleaning. At the event where blades are bent or damage, order new set of blades from service centre or dealer shop.
- There is no need to oil the fan.
Technical Specifications
MODEL
No. of Blades| EXCEL V2-5B/56
EXCEL V2-5B/48 I
EXCEL V2-5B/42
---|---
Fan Width| 1420mm (56″)| 1219mm (48″)| 1066mm (42″)
Motor RPM| 80 – 200| 94 – 260| 120 – 270
Voltage| 220-240V– 50Hz
Motor Wattage| 5W – 55W| 5W – 40W| 5W – 30W
Nett Weight| 6.3 kg| 5.0 kg| 4.6 kg
Customer Service
If you need any technical assistance or faulty report, please contact our customer service centre at :
ALPHA HOME APPLIANCES SDN. BHD. (390258-H)
Head Office
6, Jalan Sungai Kayu Ara 32/37, Berjaya Park,
Section 32, 40460 Shah Alam, Selangor.
Tel : 03-5740 6666 Fax : 03-5740 8220
Website : www.alphamalaysia.com
www.alkovagallery.com
Email : info@alphamalaysia.com
Johor
71, Jalan Molek 3/10,
Taman Molek, 81100 Johor Bahru.
Tel : 07-353 4833 / 4933 Fax : 07-355 4233
Pahang
A131, TK1, Jalan Wang Ah Jang,
Taman Liza, 25100 Kuantan, Pahang.
Tel : 09-516 522 Fax : 09-513 9226
Melaka
19, 19-1 & 19-2, Jalan KSB 11,
Taman Kota Syahbandar, 75200 Melaka.
Tel : 06-292 6292 / 6293
Fax : 06-292 6296
Perak
11, Laluan Tasek Timur 5,
Taman Tasek Indra, 31400 Ipoh, Perak.
Tel : +605-545 / 547 2282
Fax : +605-547 6282
Penang
28, Jalan Icon City, Icon City,
14000 Bukit Mentajam, Penang.
Tel : 04-506 2366 / 2066 / 2566
Fax : 04-506 2966
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>