Trane Technologies BAYSDHG001A Hail Guard Kit Side Discharge Units Installation Guide

June 13, 2024
Trane Technologies

Trane-Technologies-logo

Trane Technologies BAYSDHG001A Hail Guard Kit Side Discharge Units

Trane-Technologies-BAYSDHG001A-Hail-Guard-Kit-Side-Discharge-Units-
product

Product Information

  • Product Name: Hail Guard Kit Side Discharge Units
  • Model Numbers: BAYSDHG001A (KIT18578), BAYSDHG002A (KIT18579), BAYSDHG003A (KIT18580), BAYSDHG004A (KIT18581)
  • Manufacturer: Unknown
  • Installation Guide Version: June 2023
  • Manual Model Number: 18-HE125D1-1C-EN
  • General Description: The Hail Guard Kit is an accessory designed for use with Side Discharge Outdoor Units. It provides protection against hail damage and is intended for installation by qualified personnel only.

Product Usage Instructions

  1. Inspect the kit contents for any shipping damage and report it immediately to the transportation company.
  2. Cut the existing wire tie securing the Ambient Sensor to the Coil Guard at the fourth screw location and remove the ambient sensor wire from the coil guard loops.
  3. Remove five existing screws from each side of the existing back coil guard and set the guard aside. Repeat the same step for the side guard.
  4. Replace the Coil Guard with the new Coil Hail Guard using the recently removed screws. Place the screws in the top, middle, and lowest locations.
  5. Replace screws in the previously removed locations, even though they are not used to secure the new Hail Guard. This is important to prevent water entry and vibration noises.
  6. Use the supplied Arrowhead wire tie to secure the ambient sensor to the new Hail Guard, ensuring it is in the vertical location.
  7. Reroute the Ambient Sensor up through the wire loops in the new Hail Guard, removing any slack that may occur. Make sure the sensor is secured in the vertical position when installing the wire tie.
  8. If your unit has the Ambient Sensor as shown in the right-hand image in the manual, the arrowhead attachment is designed to prevent sensor rotation.

Warning:
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air- conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment.

Note:
This information is for use by individuals having adequate backgrounds of electrical and mechanical experience. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.

Warning:
Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized.

SAFETY WARNING

Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air- conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted, or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment.

General Data

The accessory hail guards referred to in this installation guide are provided for use with Side Discharge Outdoor Units.

Warning, Cautions, and Notices
Read this manual thoroughly before operating or servicing this unit. Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions.

Inspection:
Inspect material carefully for any shipping damage. If any damage is found it must be reported immediately and a claim made against the transportation company.

Contents of Each Kit
Description Quantity
Hail Guard 1 back
Hail Guard 1 side
Installation Guide 1
Screws 6
Arrowhead Wire Tie 1

Installation

  1. Cut the existing wire tie securing the Ambient Sensor to the Coil Guard at the fourth screw location and remove the ambient sensor wire from the coil guard loops.

  2. Remove five (5) existing screws from each side of the existing back coil guard and sit the guard aside. (Repeat for side guard)

  3. Replace Coil Guard with a new Coil Hail Guard using recently removed screws by placing them in the top, middle, and lowest locations.

  4. Replace screws in the previously removed locations, even though they are not used to secure the new Hail Guard.
    Important: It is necessary to replace all screws in the locations not used to prohibit water entry and vibration noises.

  5. Use supplied Arrowhead wire tie to secure the ambient sensor to the new Hail Guard ensuring it is in the vertical location.

  6. Reroute the Ambient Sensor up through the wire loops in the new Hail Guard removing any slack that may occur.

Important:
The Sensor is designed to function in the vertical position, ensure the sensor is secured in this position when installing the wire tie.

Note:
If your unit has the Ambient Sensor as shown in the right hand image below, the arrow head attachment is designed to prevent sensor rotation.Trane-
Technologies-BAYSDHG001A-Hail-Guard-Kit-Side-Discharge-Units-
fig-1

WARNING

EXPERIENCE REQUIRED!

  • Any attempt to repair a central air conditioning product may result in personal injury and/or property damage.
  • This information is for use by individuals having adequate backgrounds of electrical and mechanical experience. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.

WARNING

HAZARDOUS VOLTAGE!

  • Failure to follow this warning could result in property damage, severe personal injury, or death.
  • Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized.

MODELS

HAIL GUARD KIT| AMERICAN STANDARD MODEL| TRANE MODEL
---|---|---
BAYSDHG001A| 4A6L5024| 4TWL5024


BAYSDHG002A

| 4A7L5024| 4TTL5024
4A7L5030| 4TTL5030
BAYSDHG003A| 4A6L5030| 4TWL5030
4A6L5036| 4TWL5036
4A6L5042| 4TWL5042
4A7L5036| 4TTL5036
4A7L5042| 4TTL5042
4A7L5048| 4TTL5048
4A6L9024| 4TWL9024
4A6L9036| 4TWL9036
BAYSDHG004A| 4A6L5048| 4TWL5048
4A6L9048| 4TWL9048
4A6L9060| 4TWL9060

About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

18-HE125D1-1C-EN 12 Jun 2023
Supersedes 18-HE125D1-1B-EN (July 2020).

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Trane Technologies User Manuals

Related Manuals